TY - CONF A1 - Beckmann, Jörg A1 - Fratzscher, Daniel A1 - von Chrzanowski, Lars A1 - Ewert, Uwe T1 - Zeitaufgelöste THz-Spektroskopie für technische und zivile Sicherheitsanwendungen N2 - Vortrag über Zeitaufgelöste THz-Spektroskopie für technische und zivile Sicherheitsanwendungen T2 - DACH-Jahrestagung 2012 CY - Graz, Austria DA - 17.09.2012 KW - THz Spektroskopie KW - Technische und zivile Sicherheit PY - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-280013 SN - 978-3-940283-44-3 IS - DGZfP-BB 136 SP - Mi.1.C.4, 1 EP - 14 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-28001 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Wrobel, Norma A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Einstrahlgeometrie und Erkennbarkeit von Objekten in der Röntgenrückstreuradiographie N2 - Abweichend von der gängigen Vorgehensweise, mit einem Bleistiftstrahl die Lage eines Bildpunktes festzulegen und die rückgestreute Strahlung großflächig aufzunehmen, bietet die neu entwickelte Kamera Unabhängigkeit von Einstrahl- und Blickrichtung. Ausgestattet mit einer 'Optik' für hochenergetische Strahlung, wie die bereits beschriebene Schlitzblendenkamera, ist die variable Gestaltung von Einstrahl- und Blickrichtung möglich. Damit eröffnet sich die Chance, Strahlung absorbierende Details in einem Objekt sichtbar werden zu lassen, die sonst von einer streuenden Umgebung überstrahlt würden. Zudem wird gezeigt, wie sich das Erscheinungsbild von Objekten umgebungsbedingt im Rückstreubild ändern kann. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Deutschland DA - 30.05.2011 KW - Röntgenrückstreuradiographie KW - Schlitzblendenkamera KW - Varibale Einstrahlgeometrie PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250627 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Poster 20) SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25062 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Hasenstab, A. A1 - Bücherl, T. A1 - Schillinger, B. T1 - Partielle Tomographie mit Neutronen zur Beurteilung von Leimschichten in Holz N2 - Verleimte Holzproben wurden je nach Größe mit thermischen (ANTARES) bzw. schnellen Neutronen (NECTAR) an der Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) der Technischen Universität München in Garching untersucht. Entweder ließen die durchstrahlbare Schichtdicke oder die eingeschränkte Strahlgeometrie es nicht zu, das Probenteil allseitig zu durchstrahlen. Um dennoch innere Strukturen wie Leimschichten zumindest mit einem eingeschränkten Winkelbereich tomographisch darzustellen, wurde mit Hilfe des Slice-Theorems erfolgreich rekonstruiert. Ein Brett von 2 cm Dicke wurde mit thermischen Neutronen erfolgreich untersucht, ein größeres mit schnellen. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Neutronentomographie KW - Eingeschränkter Winkelbereich KW - Holz PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250649 SN - 978-3-940283-33-7 VL - 127 SP - 1 EP - 6 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-25064 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Bücherl, T. A1 - Schillinger, B. A1 - Hasenstab, A. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Limited view tomography of wood with fast and thermal neutrons N2 - Neutrons are absorbed particularly by hydrogen containing materials so they can be used as a tool for visualising heterogeneous density distributions of organic materials. Penetration limits are set by the layer thicknesses and the neutron energies applied. In case of specimens with a flat shape the situation may be encountered that the object only could be penetrated in selected directions. In addition, the overall size may exceed the beam diameter and thus the viewing window if a certain region of interest should be studied by tomography without destroying the integrity of the specimen. This study shows the capabilities and limits of thermal and fast neutrons to investigate flat wooden specimens such as boards and girders by neutron tomography under such circumstances. Taking projections was impaired either by the limits of penetrability or by the total size of the object. As a consequence, projections were included for reconstruction only from a limited angular range of 90°. It could be shown that an approach based on the slice theorem was capable to visualise structural features along the beam directions while simply omitting the perpendicular ones without causing additional artefacts. Small samples with a thickness of up to 2 cm but several times broader could be studied with the ANTARES facility of the FRM II neutron source in Garching providing thermal neutrons while larger objects required a beam of higher energy as available in the NECTAR facility of the same institution. The fast (fission) neutrons (1.5 – 2 MeV) of this site allowed investigating an area of interest inside a girder with a cross section of 23.5 x 49 cm². Internal features such as inclusions could be detected as well as a heterogeneous density distribution in glue layers. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Computed tomography KW - Slice theoreme KW - Limited angle tomography PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-250663 SN - 978-3-940283-34-4 VL - 128 SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-25066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Gollwitzer, Christian A1 - Fratzscher, Daniel A1 - Ewert, Uwe A1 - Jaenisch, Gerd-Rüdiger T1 - Simulation of complex scan paths for 3D reconstruction N2 - X-ray computed tomography (CT) is a volumetric (3D) Imaging diagnostic method, well established in the medical field, and in industrial NDE as well. Developments in industrial CT aim to extent the applicability to complex structures, which do not allow the access of all directions. This are e.g. limited view, data and angle CT applications. New reconstruction algorithms are required on one side, and the accuracy has to be improved on the other side. Numerical Simulation can support such developments by providing well defined data sets for the testing of reconstruction algorithms. This approach of virtual CT is realized within the radiographic simulator aRTist, developed by BAM. The poster shows the possibilities of this tool to consider complex scan paths. Simulated data sets have been reconstructed by an versatile backprojection algorithm. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Radiographie KW - Computer-Simulation KW - 3D-Rekonstruktion PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-243928 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 17) SP - 1 EP - 4 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Schwabe, A. A1 - Schillinger, B. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Radiography and partial tomography of wood with thermal neutrons N2 - The effective high neutron scattering absorption coefficient of hydrogen (48.5 cm²/g) due to the scattering allows neutrons to reveal hydrocarbon structures with more contrast than X-rays, but at the same time limits the sample size and thickness that can be investigated. Many planar shaped objects, particularly wood samples, are sufficiently thin to allow thermal neutrons to transmit through the sample in a direction perpendicular to the planar face but not in a parallel direction, due to increased thickness. Often, this is an obstacle that prevents some tomographic reconstruction algorithms from obtaining desired results because of inadequate information or presence of distracting artifacts due to missing projections. This can be true for samples such as the distribution of glue in glulam (boards of wooden layers glued together), or the course of partially visible annual rings in trees where the features of interest are parallel to the planar surface of the sample. However, it should be possible to study these features by rotating the specimen within a limited angular range. In principle, this approach has been shown previously in a study with fast neutrons [2]. A study of this kind was performed at the Antares facility of FRM II in Garching with a 2.6×107/cm² s thermal neutron beam. The limit of penetration was determined for a wooden step wedge carved from a 2 cm×4 cm block of wood in comparison to other materials such as heavy metals and Lucite as specimens rich in hydrogen. The depth of the steps was 1 cm, the height 0.5 cm. The annual ring structures were clearly detectable up to 2 cm thickness. Wooden specimens, i.e. shivers, from a sunken old ship have been subjected to tomography. Not visible from the outside, clear radial structures have been found that are typical for certain kinds of wood. This insight was impaired in a case where the specimen had been soaked with ethylene glycol. In another large sample study, a planar board made of glulam has been studied to show the glued layers. This study shows not only the limits of penetration in wood but also demonstrates access to structures perpendicular to the surface in larger planar objects by tomography with fast neutrons, even with incomplete sets of projection data that covers an angular range of only 90° or even 60°. KW - Neutron computed tomography KW - Limited angle tomography KW - Wood KW - Annual rings PY - 2011 U6 - https://doi.org/10.1016/j.nima.2011.02.095 SN - 0168-9002 SN - 0167-5087 VL - 651 IS - 1 SP - 236 EP - 239 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24918 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fratzscher, Daniel A1 - Beckmann, Jörg A1 - von Chrzanowski, Lars A1 - Ewert, Uwe T1 - Computed THz - tomography N2 - Available THz Time Domain Spectroscopy (THz-TDS) systems can be applied in a pulse echo mode for tomographic application. In contrast to common transmission methods, a TDS reflection geometry was used to inspect cylindrical polyethylene samples with internal voids of known shape. The geometry of the voids was simulated and its shape was reconstructed. B-scan pulse echo images were acquired in the time domain, similar to UT pulse echo techniques on basis of the numeric model. The results were used to verify the simulation model and the reconstruction algorithm, based on a modified Synthetic Aperture Focusing Technique (SAFT). The model was used to conclude recommendations on an optimized measurement setup in the reflection mode. Based on that, the quality of the reconstructed tomograms was improved. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - THz KW - Computed tomography KW - Non metallics KW - SAFT KW - Delaminations PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 10 (Paper 291) AN - OPUS4-25874 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Fratzscher, Daniel A1 - Alekseychuk, Oleksandr A1 - Einav, I. A1 - Infanzon, S. A1 - Zirnhelt, J. T1 - Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project T2 - 4. Conferencia Panamericana de END CY - Buenos Aires, Argentina DA - 2007-10-22 KW - Radiographie KW - Digitale Detektoren KW - Grenzen der Bildqualität KW - Preiswerte Prüftechnik PY - 2007 SN - 978-987-23957-0-4 IS - CD-ROM SP - 1 EP - 6 AN - OPUS4-16424 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Osterloh, Kurt A1 - Wrobel, Norma A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Hasenstab, A. T1 - Backscatter radiation - using X-rays for illumination T2 - MATEST 2009 CY - Cavtat/Dubrovnik, Croatia DA - 2009-09-23 KW - X-ray back scatter KW - Unilateral access KW - Twisted slit collimator KW - Pinhole camera principle with high energy radiation PY - 2009 SN - 978-953-7283-03-2 IS - #12 SP - 1 EP - 11 AN - OPUS4-20709 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Jechow, Mirko A1 - Fratzscher, Daniel A1 - Wrobel, Norma A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Bücherl, T. A1 - Hasenstab, A. A1 - Weiss, P. A1 - Weiss, C. A1 - Tannert, T. T1 - Strukturmerkmale im Holz - radiologisch gesehen N2 - Die radiologische Untersuchung von Holz ist hinsichtlich der Durchführung und Auswertung komplex. Im Gegensatz zu künstlich hergestellten Materialien zeichnet sich Holz besonders durch seine Heterogenität und Individualität aus, kein Stück ist wie das andere. Dies erschwert bei der radiologischen Inspektion die Fehlerdetektion, da diese teilweise schwer von natürlichen Wachstumsmerkmalen zu unterscheiden sind. Insektenfraßgänge und Hohlräume durch biologischen Abbau sind deutlich erkennbar, schwieriger wird es bei feinen Rissen und Anzeichen für Fäulnis. Metallische Einbauten wie Nägel und Bolzen sind natürlich gut zu erkennen, großflächigere Platten können jedoch den Einblick in die benachbarten Gebiete versperren. Klebstoffschichten sind im Röntgenbild nur dann sichtbar, wenn sie exakt parallel zum Strahlengang getroffen werden. Verschiedene Strukturmerkmale treten also radiologisch recht unterschiedlich in Erscheinung, deshalb liegt es nahe, zu deren Erkennung mehr als nur eine Durchstrahlungstechnologie anzuwenden. Während bei immobilen Objekten, d.h. Bauwerken und Bäumen, mobile Durchstrahlungstechniken mit Röntgen- oder Gammastrahlen (Se-75) in Frage kommen, stehen im Labor auch (schnelle) Neutronen alternativ zur Verfügung. Die verschiedenen Techniken, einschließlich der Tomographie mit Neutronen, werden an zwei größeren Prüfteilen demonstriert, einer Brettschichtholzprobe und einem Knotenpunkt aus einer Holzbrücke mit eingebauter Stahlplatte. Neutronen lassen Materialunterschiede differenzierter hervortreten und durchdringen sperrige Metallteile besser, trotz verringerter Bildqualität. An Verbesserungen wird derzeit gearbeitet. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Mobile Radiographie KW - Holzbauteilprüfung PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Poster 14) SP - 1 EP - 2 CY - Berlin AN - OPUS4-22532 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -