TY - CONF A1 - Winkler, Nicolas P. A1 - Neumann, Patrick P. A1 - Kohlhoff, Harald A1 - Erdmann, Jessica A1 - Schaffernicht, Erik A1 - Lilienthal, Achim J. T1 - Development of a Low-Cost Sensing Node with Active Ventilation Fan for Air Pollution Monitoring T2 - SMSI 2021 Proceedings N2 - A fully designed low-cost sensing node for air pollution monitoring and calibration results for several low-cost gas sensors are presented. As the state of the art is lacking information on the importance of an active ventilation system, the effect of an active fan is compared to the passive ventilation of a lamellar structured casing. Measurements obtained in an urban outdoor environment show that readings of the low-cost dust sensor (Sharp GP2Y1010AU0F) are distorted by the active ventilation system. While this behavior requires further research, a correlation with temperature and humidity inside the node shown. T2 - SMSI 2021 Conference: Sensor and Measurement Science International CY - Online meeting DA - 03.05.2021 KW - Wireless sensing node KW - Air pollution KW - Sensor network KW - Environmental monitoring PY - 2021 DO - https://doi.org/10.5162/SMSI2021/D3.5 VL - 2021 SP - 260 EP - 261 AN - OPUS4-52607 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -