TY - CONF A1 - Epple, Niklas T1 - Monitoring of bridges with coda waves - first steps towards an imaging strategy N2 - Monitoring of concrete structures is of utmost importance in maintenance and preservation of infrastructure. As a part of the DFG research group CoDA (Concrete Damage Assessment by Coda Waves), the works within this PhD project aim for identification of damage sensitive parameters extracted from ultrasonic measurements obtained with embedded sensors, the determination of environmental (reversible) influences on the signal and the localisation of damaged areas. The main technique used for the detection of changes in the monitored material is the so-called Coda Wave Interferometry (CWI). It uses the later part of the ultrasonic recording for the detection of small changes in the sensed area and the calculation of a relative velocity change. Using this technique we can show that we are able to detect changes in concrete temperature with ultrasound measurements. This enables temperature correction for ultrasound monitoring with embedded sensors. The crucial point for imaging and localisation with coda waves is the calculation of the so-called sensitivity kernels. We propose the application of numerical wave simulations for the kernel calculations instead of the commonly used diffusivity equation. Using finite-difference wave modelling code from our DFG project partners we are able to calculate those Kernels and first results are shown in this presentation. The major task for the second year will be the development and implementation of the inversion algorithm as well as the preparation of validation experiments. T2 - Doktorandenseminar BAM Abt. 8 CY - Berlin, Germany DA - 30.03.2020 KW - Ultrasound KW - Non-destructive testing KW - Numerical modelling KW - Structural health monitoring PY - 2020 AN - OPUS4-50624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas T1 - Coda Measurements for monitoring infrastructure durability N2 - Presentation about the advancements in the DFG Research unit CoDA, with focus on Coda Wave Monitoring of Infrastructure. With some case studies, possibilities and challenges are discussed on the way towards infrastructural monitoring with CWI. T2 - PhD-Seminar Department 8.2 CY - Berlin, Germany DA - 07.09.2023 KW - CWI KW - Embedded Sensors KW - Ultrasound KW - Bridge Monitoring PY - 2023 AN - OPUS4-58196 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Clauß, F. A1 - Epple, Niklas A1 - Ahrens, M. A. A1 - Niederleithinger, Ernst A1 - Mark, P. T1 - Correlation of Load-Bearing Behavior of Reinforced Concrete Members and Velocity Changes of Coda Waves N2 - The integral collection of information such as strains, cracks, or temperatures by ultrasound offers the best prerequisites to monitor structures during their lifetime. In this paper, a novel approach is proposed which uses the collected information in the coda of ultrasonic signals to infer the condition of a structure. This approach is derived from component tests on a reinforced concrete beam subjected to four-point bending in the lab at Ruhr University Bochum. In addition to ultrasonic measurements, strain of the reinforcement is measured with fiber optic sensors. Approached by the methods of moment-curvature relations, the steel strains serve as a reference for velocity changes of the coda waves. In particular, a correlation between the relative velocity change and the average steel strain in the reinforcement is derived that covers 90% of the total bearing capacity. The purely empirical model yields a linear function with a high level of accuracy (R 2 =0.99, R2=0.99, RMSE≈90μ RMSE≈90μ strain). KW - Ultrasound KW - Coda Wave Interferometry (CWI) KW - Structural Health Monitoring KW - Reinforced Concrete KW - Embedded Sensors PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542316 DO - https://doi.org/10.3390/ma15030738 VL - 15 IS - 3 SP - 738 PB - MDPI AN - OPUS4-54231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fontoura Barroso, Daniel A1 - Epple, Niklas A1 - Niederleithinger, Ernst T1 - A Portable Low-Cost Ultrasound Measurement Device for Concrete Monitoring N2 - This paper describes a new ultrasonic measuring device called “W-Box”. It was developed based on the requirements of the DFG Forschergruppe (research unit) CoDA for a portable device for monitoring of concrete specimens, models and actual structures using embedded ultrasonic transducers as well as temperature and humidity sensors. The W-Box can send ultrasonic pulses with a variable frequency of 50–100 kHz to one selectable transducer and records signals from up to 75 multiplexed channels with a sample rate of 1 MHz and a resolution of 14 bits. In addition, it measures temperature and humidity with high accuracy, adjustable amplification, restarts automatically after a power failure and can be fully controlled remotely. The measured data are automatically stored locally on-site data quality checks and transferred to remote servers. The comparison of the W-Box with a laboratory setup using commercial devices proves that it is equally reliable and precise, at much lower cost. The W-Box also shows that their measurement capacities, with the used embedded ultrasonic transducers, can reach above 6 m in concrete. KW - Low-cost KW - Coda wave interferometry KW - Ultrasound KW - IoT KW - Non-destructive testing PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-546756 DO - https://doi.org/10.3390/inventions6020036 SN - 2411-5134 VL - 6 IS - 2 SP - 1 EP - 17 PB - MDPI CY - Basel, Switzerland AN - OPUS4-54675 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Diewald, F. A1 - Epple, Niklas A1 - Kraenkel, T. A1 - Gehlen, C. A1 - Niederleithinger, Ernst T1 - Impact of External Mechanical Loads on Coda Waves in Concrete N2 - During their life span, concrete structures interact with many kinds of external mechanical loads. Most of these loads are considered in advance and result in reversible deformations. Nevertheless, some of the loads cause irreversible, sometimes unnoticed changes below the macroscopic scale depending on the type and dimension of the impact. As the functionality of concrete structures is often relevant to safety and society, their condition must be known and, therefore, assessed on a regular basis. Out of the spectrum of non-destructive monitoring methods, Coda Wave Interferometry using embedded ultrasonic sensors is one particularly sensitive technique to evaluate changes to heterogeneous media. However, there are various influences on Coda waves in concrete, and the interpretation of their superimposed effect is ambiguous. In this study, we quantify the relations of uniaxial compression and uniaxial tension on Coda waves propagating in normal concrete. We found that both the signal correlation of ultrasonic signals as well as their velocity variation directly reflect the stress change in concrete structures in a laboratory environment. For the linear elastic range up to 30% of the strength, we calculated a velocity variation of −0.97‰/MPa for compression and 0.33%/MPa for tension using linear regression. In addition, these parameters revealed even weak irreversible changes after removal of the load. Furthermore, we show the time-dependent effects of shrinkage and creep on Coda waves by providing the development of the signal parameters over time during half a year together with creep recovery. Our observations showed that time-dependent material changes must be taken into account for any comparison of ultrasonic signals that are far apart in time. The study’s results demonstrate how Coda Wave Interferometry is capable of monitoring stress changes and detecting even small-size microstructural changes. By indicating the stated relations and their separation from further impacts, e.g., temperature and moisture, we anticipate our study to contribute to the qualification of Coda Wave Interferometry for its application as an early-warning system for concrete structures. KW - Ultrasound KW - Coda Wave Interferometry (CWI) KW - Mechanical Load KW - Microstructure KW - Concrete PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556878 DO - https://doi.org/10.3390/ma15165482 SN - 1996-1944 VL - 15 IS - 16 SP - 1 EP - 15 PB - MDPI AN - OPUS4-55687 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas T1 - Bridge Monitoring with Coda Waves - Embedding Ultrasonic Transducers in a Reinforced Concrete Bridge to Monitor Small Changes in Multiply Scattered Waves N2 - Within a DFG-funded research group, we investigate the possibility of concrete damage assessment with coda waves. Coda wave interferometry (CWI) can be a valuable asset to structural health monitoring (SHM) as we can detect small signal changes and quantify them with the calculation of relative velocity changes. By equipping an in-service road bridge with more than 24 embedded ultrasonic transducers, we want to analyze how methods developed within the research group perform in an uncontrollable environment. We evaluate individual source-receiver combinations for detection of temporal changes as well as the entire installed sensor array to create maps of material change comparing two distinct states of the bridge. T2 - Research Unit CoDA Summer School 2 CY - Garmisch-Partenkirchen, Germany DA - 19.07.2022 KW - Coda Wave Interferometry KW - Embedded sensors KW - Structural Health Monitoring KW - Ultrasound KW - Reinforced Concrete Structures PY - 2022 AN - OPUS4-55382 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas T1 - Monitoring Reinforced Concrete Structures with Coda Waves The Influence of Temperature on Ultrasound Velocity Changes calculated with Coda Wave Interferometry N2 - Monitoring of reinforced concrete structures to ensure their stability and increase their service-life is a crucial element of a modern infrastructural concept. With classical methods of non-destructive testing and inspection, repeated measurements under comparable conditions are difficult to conduct. Therefore, DFG research unit FOR 2825 CoDA researches the assessment of concrete damage using ultrasound coda wave interferometry and embedded sensors. Embedding the sensors into the monitoring target reduces human and non-human factors influencing repeatability. Using Coda Wave Interferometry (CWI), small velocity changes in the material can be detected by comparison of repeated measurements. The technique is sensitive to damaging changes like cracking as well as to reversible influences like material temperature. The understanding of these different influences on the signal is crucial for the analysis of long-term monitoring data to make an educated assessment of the structure and its integrity. With several laboratory experiments in a climate chamber and a long-term experiment recording an annual cycle in a large model on an outdoor test site in Horstwalde close to Berlin, we try to understand the influence of temperature on the CWI results. The results show that the velocity change calculated by CWI does closely follow the trend of concrete temperature. After one year of data recording with the large model being exposed to environmental variations only, the calculated velocity change resembles the annual temperature curve. The data shows a linear dependency between velocity and temperature change in a range of -0.03 percent per °K to -0.06 percent per °K - regardless of specimen size. An approach to remove temperature influence from the yearly cycle recorded in the large-scale experiment using this linear relation is unable to remove high-frequency variations - especially daily influences. Low-pass filtering the data can eliminate these variations while preserving permanent shifts caused by damages. Although we have shown that the influence of temperature on long term monitoring can be removed to a significant extent, there is still an influence of environmental changes remaining in the data. Possible nonlinear effects and influences not related to temperature need to be investigated in the future. T2 - DGG 81. Jahrestagung 2021 CY - Online meeting DA - 01.03.2021 KW - Ultrasound KW - Bridge Monitoring KW - Coda Wave Interferometry KW - Structural health monitoring PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-522401 DO - https://doi.org/10.23689/fidgeo-3975 AN - OPUS4-52240 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Clauß, F. A1 - Epple, Niklas A1 - Ahrens, M. A. A1 - Niederleithinger, Ernst A1 - Mark, P. T1 - Comparison of Experimentally Determined Two-Dimensional Strain Fields and Mapped Ultrasonic Data Processed by Coda Wave Interferometry N2 - Due to the high sensitivity of coda waves to the smallest structural alterations such as strain, humidity or temperature changes, ultrasonic waves are a valid means to examine entire structures employing networks of ultrasonic transducers. In order to substantiate this ex ante assessment, the viability of measuring ultrasonic waves as a valid point of reference and inference for structural changes is to be further scrutinized in this work. In order to investigate the influence of mechanical strain on ultrasonic signals, a four-point bending test was carried out on a reinforced concrete beam at Ruhr University Bochum. Thus, measurements collected from a network of selected transducer pairings arranged across the central, shear-free segment of the test specimen, were correlated to their respective strain fields. Detected ultrasonic signals were evaluated employing Coda Wave Interferometry. Such analysis comprised the initial non-cracked state as well as later stages with incremental crack depth and quantity. It was to ascertain that the test specimen can in fact be qualitatively compartmentalized into areas of compression and tension identified via Relative Velocity Changes presented in Attribute Maps. However, since results did not entail a zero crossing, i.e., neither positive nor negative values were to be calculated, only relative changes in this work displayed staggered over the height of the object under test, are discussed. Under the given methodological premises, additional information is currently required to make quantitative assertions regarding this correlation of ultrasonic and strain results. This holds true for the comparability of the ultrasonic and strain results for both non-cracked and even the cracked state. KW - Digital image correlation KW - Fiber optic sensors KW - Coda Wave Interferometry KW - Ultrasound KW - Concrete PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-510501 DO - https://doi.org/10.3390/s20144023 SN - 1424-8220 VL - 20 IS - 14 SP - Paper 4023, 1 PB - MDPI CY - Basel AN - OPUS4-51050 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhang, T. A1 - Sens-Schönfelder, C. A1 - Epple, Niklas A1 - Niederleithinger, Ernst T1 - Imaging of Small-Scale Heterogeneity and Absorption Using Adjoint Envelope Tomography: Results From Laboratory Experiments N2 - To complement the information provided by deterministic seismic imaging at length scales above a certain resolution limit we present the first application of adjoint envelope tomography (AET) to experimental data. AET uses the full envelopes of seismic records including scattered coda waves to obtain information about the distribution of absorption and small-scale heterogeneity which provide complementary information about the investigated medium. Being below the resolution limit this small-scale structure cannot be resolved by conventional tomography but still affects wave propagation by attenuating ballistic waves and generating scattered waves. Using ultrasound data from embedded sensors in a meter-sized concrete specimen we image the distribution of absorption and heterogeneity expressed by the intrinsic quality factor Q−1 and the fluctuation strength ɛ that characterizes the strength of the heterogeneity. The forward problem is solved by modeling the 2-D multiple nonisotropic scattering in an acoustic medium with spatially variable heterogeneity and attenuation using the Monte-Carlo method. Gradients for the model updates are obtained by convolution with the back-propagated envelope misfit using the adjoint formalism in analogy to full waveform inversion. We use a late coda time window to invert for absorption and an earlier time window to infer the distribution of heterogeneity. The results successfully locate an area of salt oncrete with increased scattering and concentric anomalies of intrinsic attenuation. The resolution test shows that the recovered anomalies constitute reasonable representations of internal structure of the specimen. KW - Ultrasound KW - Scattering KW - Tomography KW - Concrete KW - Heterogeneity PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-563163 DO - https://doi.org/10.1029/2022JB024972 SN - 2169-9313 VL - 127 IS - 11 SP - 1 EP - 21 PB - American Geophysical Union AN - OPUS4-56316 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Epple, Niklas A1 - Niederleithinger, Ernst A1 - Fontoura Barroso, Daniel T1 - Coda Wave Interferometry for Monitoring Bridges with Embedded Ultrasonic Transducers – Lessons Learned at the Gänstorbrücke Bridge Ulm, Germany N2 - Ultrasonic Coda Wave interferometry has the potential to detect minute changes in scattering materials like concrete. By permanently installing ultrasonic transducers in concrete, DFG Research unit CoDA aims to develop methods for concrete damage assessment in Germany's aging infrastructure. To test the methods developed in simulations and laboratory experiments on a large scale, we have implemented several ultrasonic transducers at the Gänstorbrücke Ulm, one of Germany's most monitored road bridges. Since fall 2020 we are monitoring parts of the center of the Bridge, as well as an abutment, and compare the results to the commercial monitoring system. All data is recorded with a self-made data collection device, the so-called W-Box, and analyzed with different coda wave-based algorithms to detect signal and volumetric velocity changes. The long-term measurements show that the influence of temperature changes on strains and therefore ultrasound velocity changes calculated with coda waves can be monitored. The capabilities and limitations of the coda wave-based monitoring system are tested in a controlled experiment. Static loading using a truck with varying loads at several positions allows the calibration of the system to improve the detectability of possibly damaging loads and changes induced by this loading. A map of velocity change analyzing data from this load experiment shows that the influence of load on the material and strain distribution can be detected with array measurements. T2 - NDT-CE 2022 - The International Symposium on Nondestructive Testing in Civil Engineering CY - Zurich, Switzerland DA - 16.08.2022 KW - Coda Wave Interferometry KW - Ultrasound KW - Embedded sensors KW - Bridge Monitoring KW - Load Experiment PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-564531 SP - 1 EP - 8 AN - OPUS4-56453 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -