TY - CONF A1 - Gollwitzer, Christian A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Ewert, Uwe A1 - Jaenisch, Gerd-Rüdiger T1 - On POD estimations with radiographic simulator aRTist N2 - The computer simulation of radiography is applicable for different purposes in NDT such as for the qualification of NDT systems, the optimization of system parameters, feasibility analysis, model-based data interpretation, education and training of NDT/NDE personnel, and others. Within the framework of the European project PICASSO simulators will be adapted to support reliability assessments of NDT tasks. The radiographic simulator aRTist developed by BAM is well suited for this task. It combines analytical modelling of the RT inspection process with the CAD-orientated object description applicable to various industrial sectors such as power generation, aerospace, railways and others. The analytic model includes the description of the radiation source, the interaction of Radiation with the material of the part, and the detection process with special focus to DIR. To support reliability estimations the simulation tool is completed by a tool for probability of detection (POD) estimation. It consists of a user interface for planning automatic simulation runs with varying parameters, specifically defect variations. Further, an automatic image analysis procedure is included to evaluate the defect visibility and calculate the POD therefrom. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Radiographie KW - Computersimulation KW - Probability of detection PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-245092 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Tu.2.3) SP - 1 EP - 8 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24509 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Przybilla, Waldemar ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Measurement and modeling of scatter ratios at high energies N2 - Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Radiography KW - Optimisation KW - X-ray detection KW - Simulation KW - High energy KW - Co-60 KW - Modeling KW - Scatter PY - 2011 SN - 978-0-7354-0888-3 U6 - https://doi.org/10.1063/1.3591895 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 517 EP - 524 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-25358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -