TY - CONF A1 - Köppe, Tabea A1 - Bartholmai, Matthias A1 - Daum, Werner ED - Ognjanovic, M. ED - Stankovic, M. ED - Ristic, M. T1 - Introduction in the system of the split Hopkinson pressure bar and validation of the method N2 - The Split Hopkinson Pressure Bar (SHPB) or Kolsky Bar is known as a method for analysing mechanical properties of a material under dynamic load. Referring to the name it is a splitted Hopkinson Pressure Bar. The Hopkinson Bar is related to its inventor Bertram Hopkinson (1914). He used it to analyze stone samples under dynamic load. Later his construction was improved by Davies (1948) [1] and Kolsky (1949) [2], who had the idea to split the bar and put a sample in between. The technique is used to measure a lot of different mechanical properties of a material e.g. the dynamic Young’s modulus, deformation behaviour or to chart the dynamic stress-strain diagram. Further applications are the measurement of the elastic wave and the analysis of the propagation of the wave [2]. In the last years there was still an interest in measuring dynamic properties with a SHPB. Nevertheless no comprehensive validation of the system exists. Another problem is that the stress and the strain in the sample are only calculated with simplified estimations. The aim of this paper is to give a first impression of important points validating the system. On account of different setups of the SHPB a validation of the used system is necessary. Hence it is important to look at the theory. Further in this paper the measurement results will be shown in a strain over time diagram. T2 - DAS-29 - 29th Danubia-Adria-symposium on advances in experimental mechanics CY - Belgrade, Serbia DA - 2012-09-26 PY - 2012 SN - 978-86-7083-762-1 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. SP - 52 EP - 53 CY - Belgrade, Serbia AN - OPUS4-26638 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner T1 - Technische Diagnose von Maschinen und Konstruktionen. Vom Symptom bis zur Therapie - Innovative Messtechnik und Sensorik im Dienste von höherer Anlagenverfügbarkeit, Produktivität und Sicherheit T2 - VDI/VDE-Expertenforum 2013 - Technische Diagnose von Maschinen und Konstruktionen CY - Nuremberg, Germany DA - 2013-05-15 PY - 2013 AN - OPUS4-28897 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner T1 - Fibre Optic Sensing T2 - Mid Sweden University Colloquium CY - Sundsvall, Sweden DA - 2013-06-12 PY - 2013 AN - OPUS4-28898 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Daum, Werner ED - Czichos, Horst T1 - Embedded sensors N2 - This chapter introduces the concept of structural health monitoring, gives an overview of state-of-the-art sensing techniques used for performance control and condition monitoring, and reviews topical applications from different industrial areas. KW - Messtechnik KW - Sensorik KW - Structural health monitoring PY - 2013 SN - 978-3-642-25849-7 SN - 978-3-642-25850-3 DO - https://doi.org/10.1007/978-3-642-25850-3_13 IS - Part II / Chapter 13 SP - 259 EP - 285 PB - Springer CY - Berlin Heidelberg AN - OPUS4-28928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Daum, Werner ED - Czichos, Horst T1 - Principles, concepts and assessment of structural health monitoring N2 - This chapter introduces and describes the concept of structural health monitoring (SHM) to engineers and designers of technical structures, and to the owners/operators of such structures. It formulates general principles for integrating and implementing measurement and signal processing technologies in the context of SHM to diagnose the condition, performance and health of a technical structure. Information and recommended methods for designing instrumentation, data acquisition, data processing and data analysis for any SHM application are offered. KW - Messtechnik KW - Sensorik KW - Structural health monitoring PY - 2013 SN - 978-3-642-25849-7 SN - 978-3-642-25850-3 DO - https://doi.org/10.1007/978-3-642-25850-3_20 IS - Part IV / Chapter 20 SP - 413 EP - 424 PB - Springer CY - Berlin Heidelberg AN - OPUS4-28929 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Daum, Werner ED - Czichos, Horst T1 - Guidelines for structural health monitoring N2 - This chapter summarizes the state of the art and current developments of guidelines for structural health monitoring (SHM) and performance control. Technical guidelines and standards for condition monitoring and technical diagnostics of rotary machines and for non-destructive testing are not reviewed in this chapter. KW - Messtechnik KW - Sensorik KW - Structural health monitoring PY - 2013 SN - 978-3-642-25849-7 SN - 978-3-642-25850-3 DO - https://doi.org/10.1007/978-3-642-25850-3_27 IS - Part IV / Chapter 27 SP - 539 EP - 541 PB - Springer CY - Berlin Heidelberg AN - OPUS4-28930 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Neumann, Patrick P. A1 - Kohlhoff, Harald A1 - Daum, Werner T1 - Multi-sensor systems for safety-related monitoring N2 - The benefits of combining different types of sensors to multi-sensor systems should be demonstrated by means of three different examples of actual developments carried out by BAM Federal Institute for Materials Research and Testing: a micro-drone for gas measurement in hazardous scenarios, sensor enabled RFID tags for safeguard of dangerous goods, and a multifunctional sensor for spatially resolved under-surface monitoring of gas storage areas. Objective of the presented projects is to increase the personal and technical safety in hazardous scenarios. These examples should emphasize the potential of multi-sensor systems and point to application specific challenges for the applied components and infrastructure T2 - Sensor 2013 - 16th International conference on sensors and measurement technology CY - Nürnberg, Germany DA - 14.05.2013 KW - Multi-sensor system KW - Condition monitoring KW - Safety management KW - Hazardous scenarios KW - Data-fusion PY - 2013 SN - 978-3-9813484-3-9 DO - https://doi.org/10.5162/sensor2013/B5.2 N1 - Serientitel: AMA Conferences – Series title: AMA Conferences SP - 268 EP - 272 AN - OPUS4-28518 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner T1 - Optical 3D dynamic deformation analysis of a RAM container during a drop test T2 - 30th DANUBIA-ADRIA-Symposium on Advances in Experimental Mechanics CY - Primosten, Croatia DA - 2013-09-25 PY - 2013 AN - OPUS4-29394 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner A1 - Gründer, Klaus-Peter A1 - Kadoke, Daniel A1 - Protz, Christian A1 - Zencker, Uwe T1 - Optical 3D dynamic deformation analysis of a ram container during a drop test N2 - Containers for interim storage and final disposalof radioactive material (RAM) have to meet certain requirements regarding mechanical stability and integrity. The assessment procedure applied by BAM is based on a series of full-scale drop tests with different drop heights and Container Orientations. In parallel dynamic FEM calculations are performed. The Container behaviour is monitored during the drop test by a large number of simultaneously triggered biaxial electrical strain gauges and uniaxial accelerometers in order to measure local strains at selected positions and to determine the kinematic behaviour and Orientation of the Container during the impact. Within a research project a dynamic Stereo photogrammetry approach was applied in a high-speed camera configuration to investigate the kinematic rigid body behaviour, relative local movements of the Container or its structural parts in 3D, respectively. In the following the results of this approach are presented. A comprehensive description how to use optica) methods in drop tests can be found in. T2 - 30th Danubia-Adria symposium on advances in experimental mechanics CY - Primosten, Croatia DA - 25.09.2013 KW - Steel sheet container KW - Drop test KW - Numerical simulation KW - Optical digitization KW - High speed stereo photogrammetry PY - 2013 SN - 978-953-7539-17-7 SP - 45 EP - 46 AN - OPUS4-29414 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Czepluch, Wolf A1 - Daum, Werner A1 - Günther, Bernd T1 - Automated long-term transmission measurements of plastic optical fibres (POF) T2 - International Metrology Conference CY - Bucharest, Romania DA - 2001-09-18 PY - 2001 VL - 1 SP - 155 EP - 160 AN - OPUS4-1170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner A1 - Scholl, M. T1 - VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF T2 - 11th POF 2002 ; 11th International Plastic Optical Fibers Conference ; 11th International POF Conference CY - Tokyo, Japan DA - 2002-09-18 PY - 2002 SP - 243 EP - 246 CY - T¯oky¯o AN - OPUS4-1418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Daum, Werner T1 - Optische Messverfahren - unverzichtbares Instrumentarium in der modernen Materialforschung und -prüfung PY - 2002 SN - 0340-837X SN - 0178-2312 SN - 0171-8096 VL - 69 IS - 10 SP - 411 PB - Oldenbourg CY - München AN - OPUS4-1574 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Daum, Werner A1 - Knapp, Jürgen T1 - Sensorik für neuen Lehrter Bahnhof PY - 2002 UR - http://www.vdi-nachrichten.com/ SN - 0042-1758 VL - 56 IS - 2 SP - 6 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-1577 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Rose, Peter A1 - Raabe, Peter A1 - Daum, Werner A1 - Szameit, Andreas T1 - Neue Verfahren für die Prüfung von Reaktorkomponenten mittels Röntgen- und Gammastrahlen N2 - Mittels Mehrwinkel-Radiometrie ist es gelungen, berührungslos und automatisch die Tiefenlage von Fehlern zu bestimmen. Das Verfahren ist speziell auf alle durchstrahlbaren Objektgeometrien übertragbar. T3 - BAM Forschungsberichtreihe - 114 KW - Bildverarbeitung KW - Röntgengrobstrukturanalyse KW - Bauelement KW - Kernreaktor PY - 1985 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-3367 SN - 978-3-88314-419-3 SN - 0938-5533 VL - 114 SP - 1 EP - 243 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-336 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hässelbarth, Werner A1 - Daum, Werner A1 - Noack, Siegfried A1 - Subaric-Leitis, Andreas T1 - Ermittlung der Unsicherheit von Prüfergebnissen - Beispiele aus der chemischen Analytik und der Materialprüfung an der BAM (Evaluating the Uncertainty of Test Results - Examples from Chemical Analysis and Materials Testing at BAM) N2 - An der BAM wurde Anfang 1996 die GUM-konforme Ermittlung und Angabe der Unsicherheit quantitativer Prüfergebnisse eingeführt. Nach einem kurzen Überblick über die wesentlichen Schritte und die bisherigen Erfahrungen wird die Ermittlung der Unsicherheit an Beispielen aus zwei Schwerpunktsbereichen der Prüftätigkeit der BAM vorgestellt: atomspektrometrische Analyse anorganischer Materialien und mechanisch-technologische Werkstoffprüfung. Abschließend wird ein Ausblick auf die Ermittlung der Unsicherheit qualitativer Prüfergebnisse gegeben. Diese Arbeit ist ein ergänzender Beitrag zur Thematik des tm-Sonderheftes über GUM-konforme Auswertung von Messungen, das im Januar 2001 erschienen ist. At BAM, GUM-compliant evaluation and expression of uncertainty for quantitative test results was introduced in early 1996. After a brief overview of essential steps and experience so far, uncertainty evaluation is presented for examples from two main fields of BAM´s testing activities: analysis of inorganic materials by atomic spectrometry and mechanical materials testing using tensile/compression testing machines. Finally, an outlook is given on the evaluation of uncertainty for qualitative test results. This paper is a supplementary contribution to the topic of the tm special edition on GUM-compliant evaluation of measurements published January 2001. KW - Messunsicherheit KW - Ergebnisunsicherheit KW - Elementanalytik KW - Kalibrierlösungen KW - Zugprüfung KW - Werkstoffprüfmaschinen PY - 2001 DO - https://doi.org/10.1524/teme.2001.68.11.519 SN - 0340-837X SN - 0178-2312 SN - 0171-8096 N1 - Sprachen: Deutsch/Englisch - Languages: German/English VL - 68 IS - 11 SP - 519 EP - 528 PB - Oldenbourg CY - München AN - OPUS4-894 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Daum, Werner T1 - Zur objektiven Beurteilung der Bildqualität industrieller Radioskopie-Systeme N2 - Entwicklung von Verfahren zur Beurteilung der Bildqualität von Radioskopie-Systemen aus der zerstörungsfreien Werkstoffprüfung nach einheitlichen, objektiven und quantitativen Kriterien, Betrachtung der physikalischen Grundlagen der Strahlungserzeugung, Strahlenreliefenstehung und -umwandlung sowie der damit verbundenen Einflussgrößen auf die Bildqualität. Herleitung und Definition von Bildqualitätsmerkmalen (radiographische Kriterien, Kenngrößen aus der Systemtheorie und allgemeine optische Abbildungseigenschaften), Beschreibung wichtiger Zusammenhänge zwischen einzelnen Bildqualitätsmerkmalen und bestimmten Geräteparametern. T3 - BAM Forschungsberichtreihe - 207 PY - 1997 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-2435 SN - 978-3-89429-593-7 SN - 0938-5533 VL - 207 SP - 1 EP - 92 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-243 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Daum, Werner A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Brandes, K. A1 - Kubowitz, P. ED - Curbach, M. ED - Opitz, H. ED - Scheerer, S. ED - Hampel, T. T1 - Erweiterte Strukturabbildung von Brücken mit adaptiven mathematischen Modellen zur Lösung aktueller noch ungelöster Probleme N2 - Health monitoring von größeren Strukturen erfordert die Betrachtung der gesamten Struktur, indem sowohl jener Bereich, der experimentell behandelt wird, als auch derjenige, der einer analytischen mechanischen Untersuchung unterzogen wird, in einem Gesamtzusammenhang erfasst wird. Die umfassende Behandlung des Problems gelingt dann in einer Gesamtmatrix, die im Beitrag vorgestellt wird. Auf eine Erweiterung der Methode zur Detektierung anwachsender Schädigungen wird hingewiesen. KW - Structural Health Monitoring KW - Schadensdetektion KW - Adaptives mathematisches Modell PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa-201229 SN - 1613-6934 VL - Konstruktiver Ingenieurbau Dresden IS - 43 SP - 183 EP - 188 PB - Institut für Massivbau, TU Dresden CY - Dresden AN - OPUS4-43371 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner T1 - Zerstörungsfreie Prüfung von AM Komponenten - Ein Überblick N2 - Der Vortag erläutert typische Fehlstellen und Inhomogenitäten, die bei der additiven Fertigung entstehen können. Weiterhin wird über den aktuellen Stand der herstellungsbegleitenden zerstörungsfreien Prüfung und der zerstörungsfreien Prüfung fertiger AM-Komponenten berichtet. T2 - 3. ROUND TABLE - Additiv gefertigte Druckgeräte aus metallischen Werkstoffen CY - Frankfurt a.M., Germany DA - 22.01.2019 KW - Additive Fertigung KW - Zerstörungsfreie Prüfung PY - 2019 AN - OPUS4-47344 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hilgenberg, Kai A1 - Daum, Werner A1 - Maierhofer, Christiane A1 - Altenburg, Simon A1 - Bruno, Giovanni A1 - Heckel, Thomas A1 - Skrotzki, Birgit A1 - Zerbst, Uwe A1 - Kranzmann, Axel A1 - Bettge, Dirk A1 - Sommer, Konstantin A1 - Seeger, Stefan A1 - Nitsche, Michael A1 - Günster, Jens A1 - Evans, Alexander T1 - Additive manufacturing at the BAM: We focus on Safety N2 - In Germany, the Federal Institute for Materials Research and Testing (BAM) is addressing challenges in the implementation of additive manufacturing on the industrial landscape for safety-critical applications. KW - Process development KW - Additive Manufacturing KW - In-situ Process Monitoring KW - Non-destructive Materials KW - Characterisation KW - Safety KW - Fatigue KW - Environment KW - Standardisation PY - 2019 UR - https://static.asminternational.org/amp/201910/22/ SN - 0882-7958 VL - 177 IS - 7 SP - 22 EP - 26 PB - ASM International CY - Materials Park, OH, USA AN - OPUS4-49780 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -