TY - CONF A1 - Köppe, Tabea A1 - Bartholmai, Matthias A1 - Daum, Werner ED - Ognjanovic, M. ED - Stankovic, M. ED - Ristic, M. T1 - Introduction in the system of the split Hopkinson pressure bar and validation of the method N2 - The Split Hopkinson Pressure Bar (SHPB) or Kolsky Bar is known as a method for analysing mechanical properties of a material under dynamic load. Referring to the name it is a splitted Hopkinson Pressure Bar. The Hopkinson Bar is related to its inventor Bertram Hopkinson (1914). He used it to analyze stone samples under dynamic load. Later his construction was improved by Davies (1948) [1] and Kolsky (1949) [2], who had the idea to split the bar and put a sample in between. The technique is used to measure a lot of different mechanical properties of a material e.g. the dynamic Young’s modulus, deformation behaviour or to chart the dynamic stress-strain diagram. Further applications are the measurement of the elastic wave and the analysis of the propagation of the wave [2]. In the last years there was still an interest in measuring dynamic properties with a SHPB. Nevertheless no comprehensive validation of the system exists. Another problem is that the stress and the strain in the sample are only calculated with simplified estimations. The aim of this paper is to give a first impression of important points validating the system. On account of different setups of the SHPB a validation of the used system is necessary. Hence it is important to look at the theory. Further in this paper the measurement results will be shown in a strain over time diagram. T2 - DAS-29 - 29th Danubia-Adria-symposium on advances in experimental mechanics CY - Belgrade, Serbia DA - 2012-09-26 PY - 2012 SN - 978-86-7083-762-1 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. SP - 52 EP - 53 CY - Belgrade, Serbia AN - OPUS4-26638 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Daum, Werner A1 - Gong, Xing A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Schukar, Vivien A1 - Westphal, Anja A1 - Sahre, Mario A1 - Beck, Uwe T1 - New self - diagnostic fiber optical sensor technique for structural health monitoring N2 - Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined. T2 - 32nd DANUBIA ADRIA SYMPOSIUM on Advances in Experimental Mechanics CY - Starý Smokovec, Slovakia DA - 22.09.2015 KW - Self-diagnostic fiber optical sensor KW - Magnetostrictive metal coating KW - Magnetic field KW - Fiber bragg grating PY - 2016 U6 - https://doi.org/10.1016/j.matpr.2016.03.038 SN - 2214-7853 VL - 3 IS - 4 SP - 1009 EP - 1013 AN - OPUS4-37131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Daum, Werner A1 - Gong, Xin A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Schukar, Vivien A1 - Westphal, Anja A1 - Sahre, Mario A1 - Beck, Uwe T1 - New self diagnostic fiber optical sensor technique for structural health monitoring N2 - Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined. T2 - 32nd Danubia-Adria Symposium on advances in experimental mechanics CY - Starý Smokovec, Slovakia DA - 22.09.2015 PY - 2015 SN - 978-80-554-1094-4 SP - 1 EP - 2 CY - Zilina AN - OPUS4-35173 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -