TY - CONF A1 - Bartholmai, Matthias A1 - Neumann, Patrick P. A1 - Kohlhoff, Harald A1 - Daum, Werner T1 - Multi-sensor systems for safety-related monitoring T2 - Sensor 2013 - 16th International conference on sensors and measurement technology (Proceedings) T2 - Sensor 2013 - 16th International conference on sensors and measurement technology CY - Nürnberg, Germany DA - 2013-05-14 KW - Multi-sensor system KW - Condition monitoring KW - Safety management KW - Hazardous scenarios KW - Data-fusion PY - 2013 SN - 978-3-9813484-3-9 DO - https://doi.org/10.5162/sensor2013/B5.2 N1 - Serientitel: AMA Conferences – Series title: AMA Conferences SP - 268 EP - 272 AN - OPUS4-28518 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Johann, Sergej A1 - Daum, Werner ED - Cosmi, F. T1 - Characterization of the temperature behavior of a piezoresistive accelerometer T2 - 34rd Danubia - Adria Symposium on Advances in Experimental Mechanics - Book of proceedings N2 - Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration. Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity. This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g. This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C. T2 - 34th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Trieste, Italy DA - 19.09.2017 KW - Accelerometer KW - Temperature behavior KW - Drop test PY - 2017 UR - https://www.openstarts.units.it/handle/10077/14921 SN - 978-88-8303-863-1 SP - 93 EP - 95 CY - Trieste AN - OPUS4-42109 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Kohlhoff, Harald A1 - Helmerich, Rosemarie A1 - Daum, Werner ED - Aulova, Alexandra ED - Rogelj Ritonja, A. ED - Emri, I. T1 - Long-Term measurement of vertical displacements at the outer concrete bridges of the Berlin Main Station T2 - 33rd Danubia- Adria Symposium on Advances in Experimental Mechanics - BOOK OF ABSTRACTS N2 - Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station. T2 - 33rd Danubia- Adria Symposium on Advances in Experimental Mechanics CY - Portorož, Slovenia DA - 20.09.2016 KW - Berlin Main Station KW - Differential displacements KW - Hydraulic levelling system KW - Laser-based displacement measuring system KW - Monitoring KW - Strain measurements PY - 2016 SN - 978-961-94081-0-0 SP - 166 EP - 167 CY - Ljubljana AN - OPUS4-37646 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandes, K. A1 - Kubowitz, P. A1 - Daum, Werner A1 - Hofmann, Detlef A1 - Basedau, Frank T1 - Lagrange Multiplikator-Test zur Detektierung von zunehmender Strukturschädigung T2 - 8. Symposium Experimentelle Untersuchungen von Baukonstruktionen N2 - Mit einem auf Lagrange-Multipiikator-Tests basierenden Monitoring von Brücken ist es gelungen, in Belastungsversuchen an einer Holzbrücke (7,25 m Spannweite), an der relativ kleine Schädigungen künstlich herbeigeführt worden waren, die Zuverlässigkeit dieser Art des Monitorings zu bestätigen. Ausgangspunkte waren Messung von Durchbiegungen sowie Krümmungen und die Zusammenführung der jeweiligen Regression mit Nebenbedingungen, die den mechanischen Bedingungen gehorchen, unter Einschluss von Lagrange-Multiplikatoren, die sich als brauchbare Testparameter erwiesen. T2 - 8. Symposium Experimentelle Untersuchungen von Baukonstruktionen CY - Dresden, Germany DA - 24.09.2015 KW - Schadensfrüherkennung KW - Strukturschädigung KW - Monitoring PY - 2015 SN - 1613-6934 N1 - Serientitel: Schriftenreihe Konstruktiver Ingenieurbau Dresden – Series title: Schriftenreihe Konstruktiver Ingenieurbau Dresden IS - 40 SP - 147 EP - 157 CY - Dresden AN - OPUS4-34793 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandes, K. A1 - Neitzel, F. A1 - Daum, Werner A1 - Weisbrich, S. T1 - Detektierung von Strukturschädigungen durch Analyse der Lagrange-Multiplikatoren (LM) der Ausgleichungsrechnung T2 - Sensoren und Messsysteme 2012 - 16. GMA/ITG-Fachtagung N2 - Die ständige Überwachung von Konstruktionen während ihrer Lebenszeit ist eine bedeutsame Aufgabe, die Gegenstand vielzähliger Forschungsaktivitäten ist. Unter dem Aspekt der Nachhaltigkeit ist die Verlängerung der Nutzungsdauer bestehender Konstruktionen von unschätzbarem Wert, sowohl aus finanziellen Gründen als auch unter dem Gesichtspunkt der Erhaltung der gebauten Umwelt und des Denkmalschutzes.Bei allen Erfolgen der Projekte zur Bauwerkserhaltung ist die Frage, wie entstehende Schädigungen rechtzeitig erkannt werden können, auch wenn sie erst geringfügig sind, nicht befriedigend beantwortet worden. In diesem Beitrag wird eine neue Methode zur Detektierung von Strukturschädigungenvorgestellt. Diese beruht auf einer integrierten Auswertung von Messwerten verschiedener Sensoren nach der Methode der kleinsten Quadrate sowie der Interpretation der dabei auftretenden Langrange-Multiplikatoren.Diese Methode der Schädigungsanalyse wird anhand eines numerischen Beispiels aus einemVier-Punkt-Biegeversuchmit einem Verbundträgernäher erläutert. T2 - Sensoren und Messsysteme 2012 - 16. GMA / ITG-Fachtagung CY - Nürnberg, Germany DA - 2012-05-22 KW - Zustandsüberwachung KW - Structural health monitoring KW - Schadensdetektion KW - Ausgleichsrechnung KW - Sensorik PY - 2012 SN - 978-3-9813484-0-8 DO - https://doi.org/10.5162/sensoren2012/5.2.4 SP - 555 EP - 566 AN - OPUS4-26410 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Czepluch, Wolf A1 - Daum, Werner A1 - Günther, Bernd T1 - Automated long-term transmission measurements of plastic optical fibres (POF) T2 - International Metrology Conference T2 - International Metrology Conference CY - Bucharest, Romania DA - 2001-09-18 PY - 2001 VL - 1 SP - 155 EP - 160 AN - OPUS4-1170 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner T1 - Standardised and Particular Methods for Reliability Testing of Polymer Optical Fibres T2 - Proceedings of the Second @Asia-Pacific Polymer Fibre Optics Workshop T2 - 2nd Asia-Pacific Polymer Fibre Optics Workshop CY - Hong Kong, China DA - 2003-01-03 PY - 2003 SP - 15 EP - 20 CY - Hong Kong AN - OPUS4-2141 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner T1 - Ergebnisunsicherheit im Prüfwesen - eine Einführung in Systematik und praktische Vorgehensweisen T2 - Herausforderungen neuer Werkstoffe an die Forschung und Werkstoffprüfung - Tagungsband Werkstoffprüfung 2005 T2 - DVM-Tagung Werkstoffprüfung 2005 CY - Berlin, Deutschland DA - 2005-12-01 KW - Measurement uncertainty KW - Result uncertainty KW - Quantitative test result KW - Qualitative test result KW - Determination procedure PY - 2005 SN - 1861-8154 N1 - Serientitel: DVM-Bericht – Series title: DVM-Bericht IS - 641 SP - 51 EP - 62 PB - DVS-Verl. CY - Berlin AN - OPUS4-11629 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner A1 - Czepluch, Wolf T1 - Reliability of Step-Index and Multi-Core POF for Automotive Applications T2 - POF 2003 T2 - POF 2003 ; 12th International Conference on Polymer Optical Fiber CY - Seattle, WA, USA DA - 2003-09-14 PY - 2003 SP - 6 EP - 9 CY - Seattle, Wash. AN - OPUS4-2724 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner A1 - Rose, Peter T1 - Automatische Isolierung von Schweissnahtfehlern in Röntgenaufnahmen aus der zerstörungsfreien Materialprüfung T2 - Kurzreferate - 1. Internationale Fachtagung Automatische Bildverarbeitung T2 - 1. Internationale Fachtagung Automatische Bildverarbeitung CY - Berlin, Germany DA - 1985-10-17 PY - 1985 SP - 1 EP - 4 PB - Kammer der Technik CY - Berlin AN - OPUS4-34202 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Daum, Werner A1 - Scholl, M. T1 - VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF T2 - Proceedings of the POF 2002 T2 - 11th POF 2002 ; 11th International Plastic Optical Fibers Conference ; 11th International POF Conference CY - Tokyo, Japan DA - 2002-09-18 PY - 2002 SP - 243 EP - 246 CY - T¯oky¯o AN - OPUS4-1418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Krebber, Katerina A1 - Daum, Werner ED - Peters, K.J. T1 - Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC T2 - Smart sensor phenomena, technology, networks, and systems integration 2015 (Proceedings of SPIE) N2 - Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the user’s community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies. T2 - Smart sensor phenomena, technology, networks, and systems integration 2015 CY - San Diego, CA, USA DA - 08.03.2015 KW - Fibre-optic sensor KW - Standard KW - Temperature KW - Strain KW - Monitoring KW - Reliability KW - Application PY - 2015 DO - https://doi.org/10.1117/12.2185602 SN - 0277-786X VL - 9436 SP - 94360S-1 EP - 94360S-7 AN - OPUS4-33814 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heidt, Heinrich A1 - Rose, Peter A1 - Raabe, P. A1 - Daum, Werner T1 - Digital image processing for radiography in nuclear power plants T2 - Proceedings of the 7th International Conference on NDE in the nuclear industry T2 - 7th International Conference on NDE in the nuclear industry CY - Grenoble, France DA - 1985-01-28 PY - 1985 SP - 317 EP - 319 CY - Grenoble AN - OPUS4-34215 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Hofmann, Detlef A1 - Daum, Werner T1 - Absolute measuring EFPI-measurement system T2 - 31st Danubia-Adria Symposium on advances in experimental mechanics (Proceedings) N2 - The absolute detection of a gap distance of loose and ftxed extrinsic Fabry-Perot interferometer (EFPI) sensors with conventional measurement Systems is not possible. Due to this EFPI-sensors were deemed to be unfit for distance determination in comparision with FBG sensors. With the conventional measurement method a continous measurement of the EFPIsensors was necessary. Otherwise data about the distance change was lost. Additional it is necessary to detect the tumaround points in the interference signal with 100%. This made it worse for the analysis and the use of the sensor. At BAM Federal Institute for Materials Research and Testing a measurement System called “EFPI-Scan” is developed which can measure the absolute gap distance of four connected EFPI-sensors synchronous. Every measurement channel is temperature independetn and long term stable. Test measurements showed a deviation of maximum ±1 gm per hour. Furthermore it is possible to measure with different measurement modes (abolute, relative and a combination of both). Special emphasis should be placed to the absolute measurement accuracy of ± 5 pm at a gap distance determination ftom 40 up to 4000 pm. T2 - 31st Danubia-Adria Symposium on advances in experimental mechanics CY - Kempten, Germany DA - 24.09.2014 PY - 2014 SN - 978-3-00-046740-0 SP - 120 EP - 121 AN - OPUS4-31729 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Hofmann, Detlef A1 - Daum, Werner T1 - Absolut messendes EFPI-Messsystem T2 - Sensoren und Messsysteme 2014 - 17. ITG/GMA-Fachtagung N2 - In diesem Paper wird ein absolut messendes faseroptisches Messsystem zur Bestimmung des Gap-Abstandes von niedrig reflektierenden losen und festen extrinsischer Fabry-Pérot Interferometer (EFPI) vorgestellt. Die häufigste Methode zur Bestimmung von Dehnungen oder Bewegungen durch EFPI-Sensoren ist eine kontinuierliche relative Ermittlung einer Veränderung mit einer nachträglichen Auswertung. Unterbrechungen in der Datenerfassung oder Fehler bei der Interferenzstreifen-Auswertung führen zu einer nicht abschätzbaren Messunsicherheit. Damit war es bis dato nicht möglich, eine absolute Veränderung von eingesetzten EFPI-Sensoren zu bestimmen. Mit dem an der BAM entwickelten Verfahren, ist dies jetzt möglich, die absolute Veränderung zu bestimmen. Dieses System namens 'EFPI-Scan' wird in dem Papier dargestellt werden. T2 - Sensoren und Messsysteme 2014 - 17. ITG/GMA-Fachtagung CY - Nürnberg, Germany DA - 03.06.2014 PY - 2014 SN - 978-3-8007-3622-5 SN - 0932-6022 N1 - Serientitel: ITG-Fachbericht – Series title: ITG-Fachbericht VL - 250 SP - P16.2, 1 EP - 3 PB - VDE Verlag GmbH AN - OPUS4-32644 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Frank A1 - Köppe, Enrico A1 - Daum, Werner T1 - Tracking deformation history in split Hopkinson pressure bar testing T2 - 32nd Danubia-Adria symposium on advances in experimental mechanics (Proceedings) N2 - The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory. T2 - 32nd Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Starý Smokovec, Slovakia DA - 22.09.2015 KW - Split Hopkinson pressure bar (SHPB) KW - Digital image correlation (DIC) KW - Digitale Bildkorrelation (DIC) KW - Dynamic testing KW - Dynamische Tests KW - Stress-strain curve KW - Spannungs-Dehnungs-Kurve PY - 2015 SN - 978-80-554-1094-4 SP - 174 EP - 175 PB - University of Zilina, Slovakia CY - Zilina AN - OPUS4-35656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -