TY - JOUR A1 - Climent Terol, Estela A1 - Weller, Michael G. A1 - Martínez-Mánez, R. A1 - Rurack, Knut T1 - Immunochemical design of antibody-gated indicator delivery (gAID) systems based on mesoporous silica nanoparticles N2 - In this work, the optimization of the immunochemical response of antibody-gated indicator delivery (gAID) systems prepared with mesoporous silica nanoparticles has been studied along various lines of system tailoring, targeting the peroxide-type explosive TATP as an exemplary analyte. The mechanism of detection of these gAID systems relies on a displacement of an antibody “cap” bound to hapten derivatives anchored to the surface of a porous hybrid material, allowing the indicator cargo stored in the mesopores to escape and massively amplify the analyte-related signal. Since our aim was to obtain gAID systems with the best possible response in terms of sensitivity, selectivity, and assay time, sera obtained from different immunization boosts were screened, the influence of auxiliary reagents was assessed, structural hapten modification (hapten heterology) was investigated, and various indicator dyes and host materials were tested. Considering that highly selective and sensitive immunological responses are best obtained with high-affinity antibodies which, however, could possess rather slow dissociation constants, leading to slow responses, the main challenge was to optimize the immunochemical recognition system for a rapid response while maintaining a high sensitivity and selectivity. The best performance was observed by grafting a slightly mismatching (heterologous) hapten to the surface of the nanoparticles in combination with high-affinity antibodies as “caps”, yielding for the first time gAID nanomaterials for which the response time could be improved from hours to <5 min. The materials showed favorable detection limits in the lower ppb range and discriminated TATP well against H2O2 and other explosives. Further optimization led to straightforward integration of the materials into a lateral flow assay without further treatment or conditioning of the test strips while still guaranteeing remarkably fast overall assay times. KW - Antibody-gated indicator delivery systems KW - Signal amplification KW - Immunochemical response optimization KW - Test strip analysis KW - TATP KW - Explosives detection KW - Heterologous hapten PY - 2022 U6 - https://doi.org/10.1021/acsanm.1c03417 SN - 2574-0970 VL - 5 IS - 1 SP - 626 EP - 641 PB - American Chemical Society CY - Washington, DC AN - OPUS4-54176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hülagü, Deniz A1 - Tobias, Charlie A1 - Climent Terol, Estela A1 - Gojani, Ardian A1 - Rurack, Knut A1 - Hodoroaba, Vasile-Dan T1 - Generalized Analysis Approach of the Profile Roughness by Electron Microscopy with the Example of Hierarchically Grown Polystyrene–Iron Oxide–Silica Core–Shell–Shell Particles N2 - The roughness as a property of core–shell (CS) microparticles plays a key role in their functionality. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task with approaches using electron microscopy images being scarce and showing pronounced differences in terms of methodology and results. This work presents a generalized method for the reliable roughness determination of nonplanar specimens such as CS particles from electron microscopic images, the method being robust and reproducible with a high accuracy. It involves a self-written software package (Python) that analyzes the recorded images, extracts corresponding data, and calculates the roughness based on the deviation of the identified contour. Images of single particles are taken by a dual mode scanning electron microscopy (SEM) setup which permits imaging of the same field-of-view of the sample with high resolution and surface sensitive in SE InLens mode as well as in transmission mode (TSEM). Herein, a new type of polystyrene core–iron oxide shell–silica shell particles is developed to serve as a set of lower micrometer-sized study objects with different surface roughness; the analysis of their images by the semiautomatic workflow is demonstrating that the particles’ profile roughness can be quantitatively obtained. KW - Core–shell particles KW - Image analysis KW - Nanoparticles KW - Roughness KW - SEM KW - transmission mode PY - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-542576 SP - 1 EP - 9 PB - Wiley-VCH AN - OPUS4-54257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Rurack, Knut T1 - Streifenschnelltest mit ppt-Empfindlichkeit durch Kombination von Elektrochemilumineszenz-Detektion mit Aptamer-gesteuerter Indikatorfreisetzung aus mesoporösen Nanopartikeln N2 - Die Kombination aus elektrogenerierter Chemilumineszenz (ECL) und Aptamer-gesteuerter Indikatorfreisetzung (gAID) aus magnetischen mesoporösen Silica-Nanopartikeln, die in mit Poly(ethylenglycol) und N-(3-Triethoxysilylpropyl) diethanolamin funktionalisiertes Glasfaserpapier eingebettet sind, ermöglichte die Entwicklung eines Schnelltests, mit dem sich Penicillin direkt in verdünnter Milch bis auf 50 +/- 9 ppt in <5 min nachweisen lässt. Die kovalente Bindung der Aptamer-Kappe an das Siliciumdioxid-Gerüst ermöglichte den Verschluss der Poren durch nicht-kovalente elektrostatische Wechselwirkungen mit Oberflächen-Aminogruppen. Die Bindung von Penicillin führte zu einer Faltung des Aptamers, wodurch der zuvor in das Material geladene ECL-Reporter Ru(bpy)32+ freigesetzt wurde und nach lateralem Fluss von einer Smartphone-Kamera nach elektrochemischer Anregung mit einer in einen 3D-gedruckten Halter eingesetzten Siebdruckelektrode detektiert wird. Der Ansatz ist einfach, generisch und bietet Vorteile hinsichtlich Empfindlichkeit, Messunsicherheit und Robustheit gegenüber konventioneller Fluoreszenz- oder elektrochemischer Detektion, insbesondere für Point-of-Need-Analysen anspruchsvoller Matrices und Analyten im Ultraspurenbereich. KW - Schnelltests KW - Elektrochemilumineszenz KW - Aptamere KW - Teststreifen KW - Gesteuerte Freisetzung PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-540205 VL - 133 IS - 50 SP - 26491 EP - 26501 PB - Wiley-VCH CY - Weinheim AN - OPUS4-54020 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Rurack, Knut A1 - Hecht, Mandy T1 - Loading and Release of Charged and Neutral Fluorescent Dyes into and from Mesoporous Materials: A Key Role for Sensing Applications N2 - The aim of this study is to determine the efficiency of loading and release of several zwitterionic, neutral, anionic and cationic dyes into/from mesoporous nanoparticles to find the optimum loading and release conditions for their application in detection protocols. The loading is carried out for MCM-41 type silica supports suspended in phosphate-buffered saline (PBS) buffer (pH 7.4) or in acetonitrile, involving the dyes (rhodamine B chloride, rhodamine 101 chloride, rhodamine 101 perchlorate, rhodamine 101 inner salt, meso-(4-hydroxyphenyl)-boron–dipyrromethene (BODIPY), sulforhodamine B sodium salt and fluorescein 27). As a general trend, rhodamine-based dyes are loaded with higher efficiency, when compared with BODIPY and fluorescein dyes. Between the rhodamine-based dyes, their charge and the solvent in which the loading process is carried out play important roles for the amount of cargo that can be loaded into the materials. The delivery experiments carried out in PBS buffer at pH 7.4 reveal for all the materials that anionic dyes are more efficiently released compared to their neutral or cationic counterparts. The overall best performance is achieved with the negatively charged sulforhodamine B dye in acetonitrile. This material also shows a high delivery degree in PBS buffer. KW - Mesoporous materials KW - Charged dyes KW - Neutral dyes KW - Dye loading optimisation KW - Dye release PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-522596 UR - https://www.mdpi.com/2072-666X/12/3/249 VL - 12 IS - 3 SP - 249 PB - MDPI AN - OPUS4-52259 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Rurack, Knut T1 - Combining electrochemiluminescence detection with aptamer-gated indicator releasing mesoporous nanoparticles enables ppt sensitivity for strip-based rapid tests N2 - The combination of electrogenerated chemiluminescence (ECL) and aptamer-gated indicator delivering (gAID) magnetic mesoporous silica nanoparticles embedded into glass fibre paper functionalised with poly(ethyleneglycol) and N-(3-triethoxysilylpropyl)diethanolamine allowed the development of a rapid test that detects penicillin directly in diluted milk down to 50 ± 9 ppt in <5 min. Covalent attachment of the aptamer ‘cap’ to the silica scaffold enabled pore closure through non-covalent electrostatic interactions with surface amino groups, while binding of penicillin led to a folding-up of the aptamer thus releasing the ECL reporter Ru(bpy)32+ previously loaded into the material and letting it be detected after lateral flow by a smartphone camera upon electrochemical excitation with a screen printed electrode inserted into a 3D-printed holder. The approach is simple, generic and presents advantages with respect to sensitivity, measurement uncertainty and robustness compared with conventional fluorescence or electrochemical detection, especially for point-of-need analyses of challenging matrices and analytes at ultra-trace levels. KW - Electrochemiluminiscence KW - Hybrid materials KW - Signal amplification KW - Test strip analysis KW - Penicillin PY - 2021 U6 - https://doi.org/10.1002/anie.202110744 SN - 1433-7851 SN - 1521-3773 SP - 1 EP - 11 PB - Wiley-VCH CY - Weinheim AN - OPUS4-53447 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Wan, Wei A1 - Rurack, Knut T1 - Toward Label-Free Optical Multiplexing of Analytes in Indicator Release Lateral Flow Assays via Detection Zones Containing Tailored Capture Materials N2 - The use of macromolecules and materials immobilized in the detection zone of test strips for indicator capture and focusing in label-free lateral flow assays (LFAs) is described, with emphasis on its future use in low number multiplexing. Several materials such as polyelectrolytes, functionalized mesoporous silica micro- and nanoparticles, chemically modified cellulose or glass fibre (GF) membranes and molecularly imprinted polymer gels coated onto membranes were studied in model assays, before the most promising materials were combined with antibody-gated indicator delivering (gAID) sensor materials. Cellulose, nitrocellulose and GF membranes were used as supports and highly fluorescent dyes of different charge states as model indicators. Combination of the best performing capture materials with gAID systems made it possible to distinctly increase the sensitivity and reduce the measurement uncertainty in the LFA testing of pentaerythritol tetranitrate (PETN) in aqueous samples. In addition, dual-plexing of PETN and 2,4,6-trinitrotoluene (TNT) was realized on a single test strip containing two dedicated capture zones. KW - Rapid tests KW - Vor-Ort-Analytik KW - Multiplexing KW - Teststreifen KW - Molecularly imprinted polymers PY - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-557873 VL - 2 IS - 4 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-55787 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Garrido, E. A1 - Climent Terol, Estela A1 - Marcos, M. D. A1 - Sancenón, F. A1 - Rurack, Knut A1 - Martínez-Máñez, R. T1 - Dualplex lateral flow assay for simultaneous scopolamine and "cannibal drug" detection based on receptor-gated mesoporous nanoparticles N2 - We report herein the design of a strip-based rapid test utilizing bioinspired hybrid nanomaterials for the in situ and at site detection of the drug scopolamine (SCP) using a smartphone for readout, allowing SCP identification in diluted saliva down to 40 nM in less than 15 min. For this purpose, we prepared a nanosensor based on mesoporous silica nanoparticles loaded with a fluorescent reporter (rhodamine B) and functionalized with bethanechol, a potent agonist of recombinant human muscarinic acetylcholine receptor M2 (M2-AChR). M2-AChR interaction with the anchored bethanechol derivative leads to capping of the pores. The sensing mechanism relies on binding of SCP to M2-AChR resulting in pore opening and delivery of the entrapped rhodamine B reporter. Moreover, the material was incorporated into strips for lateral-flow assays coupled to smartphone readout, giving fast response time, good selectivity, and exceptional sensitivity. In an attempt to a mobile analytical test system for law enforcement services, we have also developed a dualplex lateral flow assay for SCP and 3,4-methylenedioxypyrovalerone (MDPV) also known as the so-called “cannibal drug”. KW - Rapid tests KW - Vor-Ort-Analytik KW - Lateral Flow Assays KW - Scopolamine KW - Gesteuerte Freisetzung KW - Cannibal Drug PY - 2022 U6 - https://doi.org/10.1039/d2nr03325a SP - 1 EP - 9 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-55744 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Costa, Elena A1 - Climent Terol, Estela A1 - Ast, S. A1 - Weller, Michael G. A1 - Canning, J. A1 - Rurack, Knut T1 - Development of a lateral flow test for rapid pyrethroid detection using antibody-gated indicator-releasing hybrid materials N2 - The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use. Antibody-gated indicator-releasing materials were thus developed and implemented with test strips for lateral-flow assay-based analysis employing a smartphone for readout. Besides a proper matching of pore sizes and gating macromolecules, the functionalization of both the material's outer surface as well as the strips with PEG chains enhanced system performance. This simple assay allowed for the detection of permethrin as a target molecule at concentrations down to the lower ppb level in less than 5 minutes. KW - Lateral flow test KW - Gated hybrid material KW - Fluorescence KW - Smartphone readout device KW - Pyrethroid KW - Pesticide KW - Insecticide KW - SBA-15 KW - Permethrin PY - 2020 U6 - https://doi.org/10.1039/d0an00319k SN - 0003-2654 SN - 1364-5528 VL - 145 IS - 10 SP - 3490 EP - 3494 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-50756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Biyikal, Mustafa A1 - Gröninger, Delia A1 - Weller, Michael G. A1 - Martínez Mánez, R. A1 - Rurack, Knut ED - Climent Terol, Estela T1 - Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles N2 - Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed. KW - Multiplexing KW - Explosives detection KW - Gated materials KW - Fluorescence PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-518424 SN - 1433-7851 SN - 1521-3773 VL - 59 IS - 52 SP - 23862 EP - 23869 PB - Wiley-VCH CY - Weinheim AN - OPUS4-51842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Biyikal, Mustafa A1 - Gröninger, Delia A1 - Weller, Michael G. A1 - Martínez Mánez, R. A1 - Rurack, Knut T1 - Multiplex‐Nachweis von Analyten auf einem einzelnen Teststreifen mit Antikörper‐gesteuerten und Indikator freisetzenden mesoporösen Nanopartikeln N2 - Vor dem Hintergrund der einzigartigen Modularität, hohen Empfindlichkeit und Selektivität von Antikörper‐gesteuerten Indikatorfreisetzungssystemen (gAID‐Systemen) wurde hier ein Multiplex‐Assay für drei organische Explosivstoffmoleküle (TATP, TNT, PETN) entwickelt, der es erlaubt, die Analyten gleichzeitig in flüssiger Phase mit einem einzelnen Teststreifen und einem Fluoreszenzlesegerät bzw. Smartphone als Detektor in Konzentrationen bis in den unteren ppb‐Bereich in <5 min nachzuweisen. Alle drei Systeme, darunter die hier neu entwickelten Systeme für TNT und PETN, tolerieren zudem nicht nur gepufferte wässrige Modelllösungen, sondern auch komplexere Matrices. Neben einem konventionellen Teststreifen mit einem Kanal erlaubte uns die Anwendung von Wachsdrucktechnologie das Herstellen von mehrkanaligen Streifen mit vergleichbarer analytischer Leistungsfähigkeit, was das enorme Potenzial der modular aufgebauten, hybriden Biosensormaterialien im Hinblick auf eine für den Endanwender maßgeschneiderte Vor‐Ort‐Analytik unterstreicht. KW - Multiplex KW - Gesteuerten Nanopartikeln KW - Explosiven PY - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-518431 SN - 1521-3757 SN - 0044-8249 VL - 132 IS - 52 SP - 24071 EP - 24078 PB - Wiley-VCH CY - Weinheim AN - OPUS4-51843 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -