TY - GEN A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - Investigations on VOC, ozone and dust emissions from hardcopy devices (laser printers, copiers and multifunctional devices) in test chambers - development of a test method T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 KW - Emissions KW - Printers KW - Copiers KW - VOC KW - Dust KW - Ozone KW - Blue Angel PY - 2003 SN - 981-049974-4 VL - 1 SP - 397 EP - 403 CY - Singapore AN - OPUS4-3315 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris ED - Wai, T. K. ED - Sekhar, C. ED - Cheong, D. T1 - VOC and SVOC Contribution of Papers for Hardcopy Devices to Indoor Air Pollution T2 - 7th Healthy Buildings Conference ; HB 2003 ; ISIAQ international conference CY - Singapore, Republic of Singapore DA - 2003-12-07 PY - 2003 SN - 981-049974-4 VL - 1 SP - 289 EP - 295 CY - Singapore AN - OPUS4-3377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Emissionsmessungen an Materialien für Fußbodenaufbauten T2 - Kolloquium Luftverunreinigungen im Innenraum CY - Düsseldorf, Deutschland DA - 2003-11-03 PY - 2003 SN - 3-18-091778-4 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 1778 SP - 71 EP - 82 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-3378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC- und SVOC-Emissionen aus Fußbodenaufbauten und den dafür verwendeten Materialien PY - 2003 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 63 IS - 3 SP - 92 EP - 98 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-2302 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Development of a Test Method for and Investigation into Limiting the Emissions from Printers and Copiers within the Framework of Assigning the Environmental Label (Research Report 201 95 311/02 / UBA-FB 00,510E) N2 - Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices. KW - Emissions KW - VOC KW - Ozone KW - Dust KW - Hardcopy device KW - Printers KW - Copiers KW - Emission test chamber KW - Environmental label PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/development-of-a-test-method-for-an-investigation SN - 1862-4804 SN - 0722-186X IS - 88 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - VOC- and SVOC-Emissions from Adhesives, Floor Coverings and Complete Floor Structures N2 - Emissions of volatile organic compounds (VOC) and semivolatile organic compounds (SVOC) from materials for flooring installation (primer, screed, adhesive, floor covering) were measured by means of emission test chambers and cells over a time period of at least 28 days at 23 °C, 50% relative humidity and an area specific air flow rate of q = 1.25 m3/m2 h. Single components were tested in comparison to three complete structures (same concrete, primer, screed, adhesive) with different types of floor covering (PVC, carpet, linoleum). Sorption into concrete/screed and different permeability of flooring materials affected the emissions from the complete structures. The complete structures with linoleum and PVC showed the same types of emission and emission rates as the individual floor coverings themselves. Emissions from the carpet-covered structure resulted also from the lower layers. In all cases emissions from the complete structures were lower than the sum of emissions from the single components. For two adhesives the formation of secondary emissions (aldehydes and organic acids) was observed starting after the standard testing time of 28 days. PY - 2004 DO - https://doi.org/10.1111/j.1600-0668.2004.00314.x SN - 0905-6947 SN - 1600-0668 VL - 14 IS - Suppl. 8 SP - 96 EP - 105 PB - Danish Techn. Pr. CY - Copenhagen AN - OPUS4-5048 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Höheres Emissionspotenzial bei Recyclingpapieren PY - 2004 SN - 0344-1733 SN - 1610-8256 VL - 28 SP - 54 EP - 56 PB - Vogel CY - Würzburg AN - OPUS4-5202 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rockstroh, Jens A1 - Jann, Oliver A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Kalus, Sabine A1 - Schneider, Uwe A1 - Krocker, Christian A1 - Horn, Wolfgang T1 - Emissionsbegrenzung aus Laserdruckern und Kopierern N2 - Vor dem Hintergrund der notwendigen Revision der Kriterien zur Vergabe des Gütezeichens "Blauer Engel" für Laserdrucker, Kopierer und Multifunktionsgeräte mussten auch die Prüfmethoden angepasst werden, da die alten Verfahren nicht mehr die heutigen Anforderungen der Emissionsmessung erfüllen. In diesem Zusammenhang wurde auch das unterschiedliche Emissionsverhalten von Hardcopy-Geräten auf Grund der verschiedenen und nicht miteinander vergleichbaren Prüfverfahren heftig diskutiert. Aus diesen Gründen wurde ein neues Prüfverfahren entwickelt, mit dem eine verlässliche und reproduzierbare Prüfung der Emissionsraten von Staub, Ozon und flüchtiger organischer Verbindungen auf der Basis des ECMA (European Computer Manufacturer Association) Standards 328 möglich ist. Dazu wurden neun verschiedene Geräte unter verschiedenen Bedingungen untersucht. Als ein Ergebnis dieser Studie wurden neue Kriterien zur Vergabe des "Blauen Engels" für Kopierer, Drucker und Multifunktionsgeräte festgelegt. PY - 2004 DO - https://doi.org/10.3139/120.100606 SN - 0025-5300 VL - 46 IS - 9 SP - 465 EP - 471 PB - Carl Hanser Verlag CY - München AN - OPUS4-4120 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Jann, Oliver A1 - Brödner, Doris T1 - Direkte thermische Extraktion versus Prüfkammer - Emissionsverhalten von Teppichklebstoffen sicher bestimmen PY - 2004 UR - http://www.gerstel.de/pdf/GERSTEL_Aktuell_32_4-5_de.pdf IS - 32 SP - 4 EP - 5 CY - Mülheim an der Ruhr AN - OPUS4-3498 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Horn, Wolfgang A1 - Gellert, R. A1 - Jann, Oliver A1 - Kalus, Sabine A1 - Brödner, Doris T1 - Emission tests on thermal insulation products with the intention to implement these tests into EN standards T2 - Indoor Air 2005 CY - Beijing, PR China DA - 2005-09-04 KW - Bauprodukte KW - Emissionen KW - Dämmstoffe KW - Kammerverfahren KW - VOC KW - EN-Standards KW - Insulation material KW - VOC emission KW - Chamber copmparison KW - Construction products directive KW - AgBB-scheme PY - 2005 SN - 7-89494-830-6 IS - 2 SP - 1886 EP - 1890 PB - Tsinghua University Press CY - Beijing AN - OPUS4-7612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -