TY - JOUR A1 - Wildgruber, M. A1 - Lueg, C. A1 - Borgmeyer, S. A1 - Karimov, I. A1 - Braun, Ulrike A1 - Kiechle, M. A1 - Meier, R. A1 - Koehler, M. A1 - Ettl, J. A1 - Berger, H. T1 - Polyurethane versus silicone catheters for central venous port devices implanted at the forearm N2 - Purpose: We aimed to analyse short and long-term complications of polyurethane (PU) versus silicone catheters used in totally implantable venous-access ports (TIVAPs) implanted at the forearm. Methods: Retrospective analysis of 698 consecutively implanted TIVAPs was performed. Primary end-points were defined as rates of major complications associated with either type of central venous port catheter. Technical success rate, device service interval as well as minor complications not requiring port explantation were defined as secondary end-points. Results: A total of 698 port devices were implanted in 681 patients, 396 equipped with a PU catheter, 302 with a silicone catheter. The technical success rate was 99.9% with no major periprocedural complications. During follow-up a total of 211 complications in 146 patients were observed (1.0/1000 catheter days), 183 occurred associated with PU catheters (1.8/100 catheter days), 28 (0.3/1000 catheter days) with silicone catheters (log rank test p < 0.0001). Catheter-related bloodstream infections as well as thrombotic complications occurred significantly more frequently with PU catheters, while silicone catheters exhibited a trend towards a higher rate of mechanical failure such as disconnection or catheter rupture. Major complications requiring explantation of the device occurred more frequently with PU-based catheters (10.6%) compared to silicone catheter carrying ports (4.6%, log rank test p < 0.001). KW - Chemotherapy KW - Central venous access port KW - Complication KW - Thrombosis KW - Infection PY - 2016 U6 - https://doi.org/10.1016/j.ejca.2016.02.011 SN - 0959-8049 VL - 59 SP - 113 EP - 124 PB - Elsevier Ltd. CY - Oxford, UK AN - OPUS4-36288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -