TY - CONF A1 - Haith, M. I. A1 - Ewert, Uwe A1 - Hohendorf, Stefan A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Huthwaite, P. A1 - Lowe, M. J. S. A1 - Zscherpel, Uwe T1 - Modelling based radiography for NDE of subsea pipelines N2 - This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results. T2 - 42nd Annual Review of Progress CY - Minneapolis, Minnesota, USA DA - 26.07.2015 KW - Modelling KW - Radiography KW - Pipeline inspection KW - Nondestructive evaluation PY - 2016 SN - 978-0-7354-1353-5 DO - https://doi.org/10.1063/1.4940575 SN - 0094-243X VL - 1706 SP - 110004-1 EP - 110004-8 PB - AIP Publishing AN - OPUS4-37553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Redmer, Benrhard A1 - Schumacher, David A1 - Thiessenhusen, Kai-Uwe A1 - Bellon, Carsten A1 - Nicholson, P. I. A1 - Clarke, A. L. A1 - Finke-Härkönen, K.-P. T1 - X-ray tomographic in-service inspection of girth welds – the european project tomoweld N2 - The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined. T2 - QNDE 2014 CY - Boise, Idaho, USA DA - 20.07.2014 KW - X-ray imaging KW - Tomography KW - Engineering inspection KW - Radiography KW - Welded joints KW - Chemical plants PY - 2015 SN - 978-0-7354-1292-7 DO - https://doi.org/10.1063/1.4914650 SN - 0094-243X N1 - Geburtsname von Schumacher, David: Walter, D. - Birth name of Schumacher, David: Walter, D. VL - 1650 SP - 525 EP - 533 PB - American Institute of Physics AN - OPUS4-36581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - aRTist – An Industrial-Radiology Simulator Using Tcl/Tk & VTK N2 - Industrial radiography or Radiographic Testing (RT) is a method of non-destructive testing where many types of manufactured components can be examined to verify the internal structure and integrity of the specimen. The computer program aRTist can generate synthetic radiographs from a virtual RT test set-up. In the field of industrial radiology simulation is used, e.g. to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport. The program comes with a graphical user interface written in Tcl/Tk. In combination of Tcl/Tk and the 3D capabilities of the visualization toolkit (VTK) a practical and convenient simulator has been realized. This will be illustrated by discussing application scenarios of classical radiography, X-ray computer tomography, and X-ray backscatter imaging. Additionally, some insight to the software implementation of the simulator will be given. T2 - EuroTCL 2017, 15th European Tcl/Tk User Meeting CY - Berlin, Germany DA - 08.07.2017 KW - Simulation KW - Radiography KW - Computed tomography PY - 2017 AN - OPUS4-43153 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brierley, N. A1 - Bellon, Carsten A1 - Lazaro Toralles, B. T1 - Optimized multi-shot imaging inspection design N2 - The inspection of complex-shaped components, such as those enabled by additive manufacturing, is a major challenge in industrial quality assurance. A frequently adopted approach to volumetric non-destructive evaluation is X-ray computed tomography, but this has major drawbacks. Two-dimensional radiography can overcome some of these problems, but does not generally provide an inspection that is as capable. Moreover, designing a detailed inspection for a complex-shaped component is a labour-intensive task, requiring significant expert input. In response, a computational framework for optimizing the data acquisition for an image-based inspection modality has been devised. The initial objective is to advance the capabilities of radiography, but the algorithm is, in principle, also applicable to alternative types of imaging. The algorithm exploits available prior information about the inspection and simulations of the inspection modality to allow the Determination of the optimal inspection configuration, including specifically component poses with respect to the imaging system. As an intermediate output, spatial maps of inspection performance are computed, for understanding spatially varying limits of detection. Key areas of innovation concern the defect detectability evaluation for arbitrarily complex indications and the creation of an application-specific optimization algorithm. Initial trials of the algorithm are presented, with good results. KW - Inspection design and planning KW - Optimization KW - Radiography KW - Simulation PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-458363 DO - https://doi.org/10.1098/rspa.2017.0319 SN - 1471-2946 SN - 1364-5021 VL - 474 IS - 2216 SP - 70319, 1 EP - 25 PB - The Royal Society CY - London AN - OPUS4-45836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhukovskiy, M. A1 - Podoliako, S. A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Samadurau, Uladzimir ED - Thompson, D. T1 - Monte Carlo Simulation Tool with CAD Interface T2 - 32th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Brunswick, ME, USA DA - 2005-07-31 KW - Monte Carlo Simulation KW - Radiography KW - CAD PY - 2006 SN - 0-7354-0312-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 820 SP - 574 EP - 581 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-12436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe ED - Thompson, D. O. T1 - Reliability assessment by simulation for high energy radiography T2 - 33th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Portland, OR, USA DA - 2006-07-30 KW - Simulation KW - Radiography KW - CAD KW - Probability of Detection PY - 2007 SN - 978-0-7354-0399-4 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 894 SP - 1831 EP - 1838 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-15696 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe T1 - aRTist - Analytical RT Inspection Simulation Tool for Industrial Application T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Computer Simulation KW - Radiography KW - Computed Tomography KW - Ray Tracing PY - 2008 SP - 1 EP - 6 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger T1 - aRTist - Analytical RT Inspection Simulation Tool T2 - DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography CY - Lyon, France DA - 2007-06-25 KW - Computer Simulation KW - Radiography KW - Computed Tomography KW - Ray Tracing PY - 2007 UR - http://www.ndt.net/article/dir2007/papers/s1.pdf SP - 1 EP - 5 CY - Lyon, France AN - OPUS4-16086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Schumm, A. A1 - Tabary, J. A1 - Duvauchelle, P. ED - Thompson, D. O. ED - Chimenti, D. E. T1 - A proposed benchmark problem for scatter calculations in radiographic modelling T2 - 35th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Chicago, IL, USA DA - 2008-07-20 KW - Radiography KW - Justifications or modifications of Monte Carlo methods KW - Emission KW - Absorption, and scattering of electromagnetic radiation KW - X-ray scattering KW - Radiographie KW - Simulation KW - Benchmark KW - Monte Carlo Verfahren KW - Streustrahlung PY - 2009 SN - 978-0-7354-0629-2 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1096 SP - 1930 EP - 1937 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-20134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Schumm, A. A1 - Tabary, J. A1 - Duvauchelle, P. ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Radiographic benchmark problem 2009 - scatter calculations in modelling T2 - 36th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Kingston, RI, USA DA - 2009-07-26 KW - Radiography KW - Justifications or modifications of Monte Carlo methods KW - Emission KW - Absorption and scattering of electromagnetic radiation KW - X-ray scattering KW - Simulation KW - Röntgenspektrum Benchmark KW - Monte Carlo Modell PY - 2010 SN - 978-0-7354-0748-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1211 SP - 2117 EP - 2124 CY - Melville, NY AN - OPUS4-21137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Przybilla, Waldemar ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Measurement and modeling of scatter ratios at high energies N2 - Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Radiography KW - Optimisation KW - X-ray detection KW - Simulation KW - High energy KW - Co-60 KW - Modeling KW - Scatter PY - 2011 SN - 978-0-7354-0888-3 DO - https://doi.org/10.1063/1.3591895 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 517 EP - 524 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-25358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Schumm, A. A1 - Lucet-Sanchez, F. A1 - Guerin, P. ED - Chimenti, D.E. ED - Bond, L.J. T1 - Radiography benchmark 2014 N2 - The purpose of the 2014 WFNDEC RT benchmark study was to compare predictions of various models of radiographic techniques, in particular those that predict the contribution of scattered radiation. All calculations were carried out for homogenous materials and a mono-energetic X-ray point source in the energy range between 100 keV and 10 MeV. The calculations were to include the best physics approach available considering electron binding effects. Secondary effects like X-ray fluorescence and bremsstrahlung production were to be taken into account if possible. The problem to be considered had two parts. Part I examined the spectrum and the spatial distribution of radiation behind a single iron plate. Part II considered two equally sized plates, made of iron and aluminum respectively, only evaluating the spatial distribution. Here we present the results of above benchmark study, comparing them to MCNP as the assumed reference model. The possible origins of the observed deviations are discussed. T2 - 41st Annual review of progress in quantitative nondestructive evaluation CY - Boise, Idaho, USA DA - 20.07.2014 KW - Radiography KW - Spectrum KW - Modeling KW - Validation PY - 2015 SN - 978-0-7354-1292-7 DO - https://doi.org/10.1063/1.4914809 N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1650 SP - 1834 EP - 1846 PB - AIP Publishing AN - OPUS4-33083 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Ewert, Uwe ED - Chimenti, D.E. ED - Bond, L.J. T1 - Fast model of electron transport for radiographic spectrum simulation N2 - Correctly modeling the continuous photon spectrum of X-ray tubes requires detailed knowledge of the probability distribution of electron properties at the time of X-ray photon creation, in particular electron energy, depth within the target, and direction of movement. Semi-analytical X-ray spectrum models frequently assume a very simplified or even uniform distribution of electron direction. In the case of thick targets and small deviations from normal incidence this is a useful approximation. For thin targets or large deviations from normal incidence the correct distribution of electron directions becomes more important. As calculation speed is an important aspect of semi-analytical models compared to Monte Carlo simulations, fast evaluation of the distribution of electron properties is highly desirable. The approach presented here numerically evaluates the evolution of a discrete probability distribution of electron properties due to single electron scatter interactions within a plane target. This allows capturing the important aspects of the electron distribution while achieving runtimes of a few seconds up to a minute on a standard office PC. T2 - 41st Annual review of progress in quantitative nondestructive evaluation CY - Boise, Idaho, USA DA - 20.07.2014 KW - Radiography KW - Spectrum KW - Modeling KW - Valildation PY - 2015 SN - 978-0-7354-1292-7 DO - https://doi.org/10.1063/1.4914656 N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1650 SP - 579 EP - 585 PB - AIP Publishing AN - OPUS4-33082 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schumm, A. A1 - Duvauchelle, P. A1 - Kaftandjian, V. A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Tabary, J. A1 - Mathy, F. A1 - Legoupil, S. ED - Büyüköztürk, O. T1 - Modelling of radiographic inspections N2 - Computer modelling of non-destructive testing methods has come a long way from the beginnings in the mid 90s to today. Radiographic modelling for components with higher wall thicknesses, as they are typical for nuclear applications, must include precise predictions of scattered radiation and its impact in terms of contrast reduction. Dedicated or general purpose Monte Carlo methods with the ability to calculate higher order scattering events are the state of the art for these applications. Aerospace applications, on the other hand, have stronger requirements on the modelling code's capabilities to import complex CAD geometries, and can benefit from faster analytical scatter models, limited to first or second order scattering events. Similar distinctions can be made for the various approaches proposed to accurately model geometrical and film unsharpness, film granularity, film responses, film/foil cartridges and photon noise. This article presents a state-of-the-art review of radiographic modelling from the perspective of two important application domains with very different requirements, nuclear and aerospace. T2 - NDTMS-2011 CY - Istanbul, Turkey DA - 15.05.2011 KW - Computer modelling KW - Monte-Carlo KW - Radiography KW - Film KW - Selenium PY - 2013 SN - 978-94-007-0722-1 SN - 978-94-007-0723-8 DO - https://doi.org/10.1007/978-94-007-0723-8_99 VL - 6 SP - 697 EP - 702 PB - Springer Netherlands AN - OPUS4-36655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Combining analytical and Monte Carlo modelling for industrial radiology N2 - Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we focus on Monte Carlo simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications. T2 - 19th World Conference on Non-Destructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Monte Carlo method KW - Radiography KW - Simulation PY - 2016 AN - OPUS4-36617 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - A fast general spectrum model for quantitative radiography simulation N2 - A model is presented that employs a unified approach for simulating the photon energy spectra for transmission and direct beam targets composed of arbitrary homogeneous materials. In order to achieve this, a detailed model of electron transport within the target is employed. The validity of the developed model is shown through comparisons with Monte Carlo simulations as well as measurements for a number of different configurations. T2 - 19th World Conference on Non-Destructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Modelling KW - Radiography KW - Simulation KW - X-ray spectrum PY - 2016 AN - OPUS4-36628 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Computersimulation in der Durchstrahlungsprüfung N2 - Vorstellung der Software "aRTist" zur Computersimulation von Durchstrahlungsprüfungen und deren Anwendungsfelder. T2 - DGZfP-Arbeitskreis Berlin, 385. Sitzung CY - Berlin, Germany DA - 07.03.2017 KW - Radiography KW - Simulation PY - 2017 AN - OPUS4-40165 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas T1 - Combining analytical and Monte Carlo modelling for industrial radiology N2 - Modelling becomes more and more important in modern NDE. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for education purposes. To describe the complete chain of RT, the model includes simulating all necessary properties of X- or Gamma-ray sources, the interaction of photons with material with special attention to scattered radiation, the detection process, and the complete geometrical RT setup handling arbitrary parts or constructions. Depending on the given inspection problem and the influencing factors that should be addressed by the simulation, an appropriate physical model has to be chosen to describe the underlying interaction mechanisms. The simulator aRTist combines analytical and Monte Carlo methods to efficiently model the radiation transport such that transmission as well as scatter techniques can be modelled. In this contribution we Focus on Monte Carlo Simulation of scatter contribution within aRTist. Examples for RT/tomographic applications and back-scatter techniques are presented to demonstrate the usability of the presented simulation tool for a broad range of radiological applications. T2 - 19th Wolrd Conference on Nondestructive Testing CY - Munich, Germany DA - 13.06.2016 KW - Radiography KW - Computed tomography KW - Simulation KW - Monte Carlo methods PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-365856 SN - 978-3-940283-78-8 VL - 158 SP - 1 EP - 9 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung (DGZfP) CY - Berlin, Germany AN - OPUS4-36585 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -