TY - JOUR A1 - Prakash, Swayam A1 - Bell, Jérémy A1 - Rurack, Knut T1 - Rapid Onsite Detection of Fecal Contamination in Water Using a Portable Fluorometric Assay N2 - Fecal pollution in water poses significant health risks, especially when contaminated sources are used for drinking and food production. Traditional water quality testing methods are expensive, slow, and require skilled personnel, limiting their accessibility. This work addresses these issues by developing a portable fluorometric assay for the detection of the fecal indicator pigment urobilin (UB). The assay uses silane-functionalized glass fiber strips impregnated with zinc chloride, providing a ‘drop-&-detect’ approach with enhanced fluorescence response mediated by the unique complexation properties of ZnCl2 and UB. This approach allows for the detection of UB at sub-nanomolar concentrations in less than 1 min using a 3D-printed setup with miniaturized optical components powered by a smartphone with its camera as a detector. The results validated with a benchtop fluorometer show the effectiveness of this method. The successful application of this userfriendly, rapid, and sensitive assay to real water samples from three rivers and the influx and efflux of a wastewater treatment plant advances field-based water quality monitoring, meets the WHO’s ASSURED criteria, and supports progress toward the global clean water and sanitation goals. KW - Fecal pigment KW - Fluorescence KW - Signal amplification KW - Surface chemistry KW - Water quality testing PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-655543 DO - https://doi.org/10.1021/acssensors.5c03922 SN - 2379-3694 VL - 11 SP - 1 EP - 9 PB - American Chemical Society CY - Washington, D.C. AN - OPUS4-65554 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hernández-García, María Amparo A1 - Rurack, Knut A1 - Bell, Jérémy T1 - Rapid fabrication of optical elements for sensing applications using a standard SLA printer N2 - The demand for compact, high-performance optical components has driven the development of increasingly sophisticated and miniaturized optical elements, often requiring complex and costly fabrication methods. In this study, we propose a cost-effective and accessible methodology for the fabrication of lenses and free-form optics using a commercially available stereolithography (SLA) 3D printer. A systematic characterisation of six transparent photopolymer resins was conducted in terms of their spectroscopic, optical, and morphological properties, i.e., surface and dimensional properties. The evaluation encompassed parameters such as transmittance, autofluorescence, refractive index, and surface roughness. A straightforward yet resilient printing and post-treatment protocol was formulated, facilitating the fabrication of optical components with over 80% transmittance, minimal intrinsic fluorescence, and surface quality that is compatible with exacting optical applications. The fabricated components demonstrated excellent dimensional fidelity to digital designs and high reproducibility. To demonstrate the versatility of this approach, aspherical, miniaturized, and freeform lenses were designed and integrated into three fluorogenic sensing systems, including oil (strip-based) and chlorine (microfluidic-based) detection platforms, as well as a smartphone-based SARS-CoV-2 biosensor. The integration of customized 3D-printed optics has been demonstrated to enhance signal collection and readout performance, thereby highlighting the potential of this approach to democratize the rapid prototyping and deployment of miniaturized optical systems. This work represents a significant advancement in the field of additive manufacturing, particularly in relation to the development of functional photonic devices. Furthermore, it opens new prospects for sensor applications in biosensing, microfluidics, imaging, and integrated optics. KW - 3D-printing KW - Free-form KW - Prototyping KW - Optical resin KW - Surface finishing KW - Fluorescence KW - Sensor PY - 2026 DO - https://doi.org/10.37188/lam.2026.024 VL - 7 SP - 1 EP - 19 PB - Light Publishing Group CY - Changchun AN - OPUS4-65555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ecke, Alexander A1 - Bell, Jérémy A1 - Schneider, Rudolf T1 - From Laboratory Immunoassays to Immunosensors with an Integrated Microfluidic Flow System N2 - This research summary describe efforts to the development of a three-dimensional microfluidic flow cell for improved electrochemical substrate detection in HRP/TMB-based immunoassays. This work provides a valuable advancement in the sensitivity and integration of immunoassay technologies, aiding in the refinement of diagnostic tools. KW - Antikörper KW - Immunoassay KW - Microfluidics KW - Electrochemical detection KW - Biosensor PY - 2025 UR - https://www.elveflow.com/microfluidics-research-summaries/from-laboratory-immunoassays-to-immunosensors-with-an-integrated-microfluidic-flow-system/ SP - 1 EP - 4 CY - Paris AN - OPUS4-62674 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bell, Jérémy T1 - Embedded sensor for the detection of TNT in surface and marine waters N2 - In 1945, the Potsdam Conference led to the decision to destroy a significant amount of ammunition from the warring parties of WWII. Dumping was considered the cheapest, quickest, and safest solution to dispose of unused ammunition. However, thin barrels or containers often leak after 50 years, allowing explosives to escape into the marine environment. As the effects of weapons chemicals on ecosystems are well-documented, it is becoming increasingly important to detect, recover and dispose of old ammunition. Physical techniques such as magnetometry and sonar are used to detect ammunition in the sea, but they do not provide chemical information. Detecting leaking organic contaminants like TNT or other explosives in water or soil requires high-end laboratory equipment like HPLC or GC-MS, making remote water testing virtually impossible. As an alternative, a miniaturized method for the selective and sensitive indication of TNT using fluorescence light-up sensing was developed. The visual identification of TNT with a nucleophile that forms a strongly absorbing charge transfer complex (CTC) is a well-known method. This CTC is formed by the attraction of an electron from the donor molecule by the electron-deficient aromatic ring. In this work, a TNT-based CTC was selectively formed by the addition of tetraoctylammonium acetate in N,N-diethylformamide and, as expected, showed strong absorption. Surprisingly, at room temperature, the CTC can be converted into a fluorescent product with an emission band centred at 577 nm. For the detection of TNT in water, a microfluidic chip made of polydimethylsiloxane (PDMS) is used for both the extraction and reaction steps. In addition to miniaturising the experimental steps, the optical system (fluorometer) has been integrated into an autonomous smartphone assembly capable of catalysing the photoreaction and analysing the fluorescence response. Taking advantage of the light-up response, TNT was still easily detectable down to 9.4 ng with the CMOS camera. Further evaluation of this analytical tool consisted of analyses of unfiltered and untreated surface water samples spiked directly with increasing concentrations of TNT to reflect different levels of contamination. LODs of 21 and 40 ng were found for samples from the Teltow Canal in Berlin (DEU) and the Baltic Sea near Greifswald (DEU). Such an analytical tool could be used to monitor water quality in the field, as the release of organic pollutants from munitions into surface and marine waters will become increasingly problematic and concentrations will continue to rise over the coming decades. T2 - ANAKON 2025 CY - Leipzig, Germany DA - 10.03.2025 KW - Explosives KW - Microfluidics KW - Smartphone KW - Sprengstoffe KW - Mikrofluidik KW - Sensor PY - 2025 AN - OPUS4-62767 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - López-Puertollano, Daniel A1 - Tobias, Charlie A1 - Bell, Jérémy A1 - Abad-Somovilla, A. A1 - Abad-Fuentes, A. A1 - Rurack, Knut T1 - Superparamagnetic Bead-Based Microfluidic Fluoroimmunoassay Platform for Rapid Ochratoxin A Detection in Flour N2 - Simplification and reduction of time and costs are the primary goals in the development and use of onsite methods in diagnostics and food safety. To facilitate the transition from laboratory techniques to simple, miniaturized devices, we have developed a modular microfluidic platform. This platform integrates a competitive fluorescence immunoassay on the surface of superparamagnetic beads, serving as a complementary technique to traditional cytometry assays. In the first chip module, a fast competitive reaction (5 min) occurs, after which the particles are retained in the second module. This module consists of a PDMS chip and a permanent magnet, allowing only the fluorescent competitor to reach the detection module. Ochratoxin A (OTA) was chosen as the model analyte for device development, using fluorescein-labeled OTA as a competitor. The system efficiently separates particles, with OTA concentration directly correlated to the amount of fluorescent competitor remaining in solution after the competitive reaction. This innovative setup allows to perform rapid measurements with small sample volumes in a short time (10 min), achieving a limit of detection for OTA of 1.2 μg L–1. The system was successfully applied to the accurate determination of OTA in wheat flour spiked at regulatorily relevant concentrations. Using this device, conventional cytometry immunoassays can be seamlessly transformed into user-friendly, miniaturized analytical methods at reduced cost for applications outside of a laboratory directly at the point of need. KW - Bead-based assay KW - Fluorescence KW - Immunoassay KW - Microfluidics KW - mycotoxins PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-638472 DO - https://doi.org/10.1021/acssensors.5c01119 SN - 2379-3694 SP - 1 EP - 10 PB - American Chemical Society CY - Washington, D.C. AN - OPUS4-63847 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jamieson, O. D. A1 - Bell, Jérémy A1 - Hudson, A. A1 - Saczek, J. A1 - Perez-Padilla, Victor A1 - Kaiya, G. A1 - Novakovic, K. A1 - Davies, M. A1 - Foster, E. A1 - Gruber, J. A1 - Rurack, Knut A1 - Peeters, M. T1 - Design and Application of an Imprinted Polymer Sensor for the Dual Detection of Antibiotic Contaminants in Aqueous Samples and Food Matrices N2 - An innovative polymer-based dual detection microfluidic platform has been developed for the accurate and reliable sensing of trace amounts of antibiotic tetracycline in environmental and food samples. This was achieved through the production of a bespoke polymeric material formed via an imprinting technique using a fluorescent dye. Thus, this enables dual detection of tetracycline, both thermally, via analyzing the heat-transfer resistance at the solid−liquid interface, and optically, through the inner filter effect. The combination of these two methods achieved a nanomolar limit of detection for tetracycline while also providing rapid, selective, and cost-effective sensing. Additionally, this method successfully detected tetracycline levels of 0.56 μM in blank egg samples which was significantly lower than the maximum residual level of 400 μg L−1 (0.9 μM). Our work shows that this approach can be used for the efficient detection of trace antibiotics in complex environmental and food samples, offering enhanced reliability through the integration of two complementary analysis techniques. This sensor has the potential to identify sources of antimicrobial resistance, which is crucial for targeted efforts to combat this pressing global health challenge. KW - Molecularly imprinted polymers KW - Antibiotics monitoring KW - Orthogonal detection KW - Sensors PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-626497 DO - https://doi.org/10.1021/acsapm.4c03218 SN - 2637-6105 VL - 7 IS - 4 SP - 1 EP - 9 PB - American Chemical Society CY - Washington, D.C. AN - OPUS4-62649 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sun, Yijuan A1 - Pérez-Padilla, Víctor A1 - Valderrey, Virginia A1 - Bell, Jérémy A1 - Gawlitza, Kornelia A1 - Rurack, Knut T1 - Ratiometric detection of perfluoroalkyl carboxylic acids using dual fluorescent nanoparticles and a miniaturised microfluidic platform N2 - The widespread contamination of soil and water with perfluoroalkyl substances (PFAS) has caused considerable societal and scientific concern. Legislative measures and an increased need for remediation require effective on-site analytical methods for PFAS management. Here we report on the development of a green-fluorescent guanidine-BODIPY indicator monomer incorporated into a molecularly imprinted polymer (MIP) for the selective detection of perfluorooctanoic acid (PFOA). Complexation of PFOA by the indicator, which is mediated by concerted protonation-induced ion pairing-assisted hydrogen bonding, significantly enhances fluorescence in polar organic solvents. The MIP forms as a thin layer on silica nanoparticles doped with tris(bipyridine)ruthenium(II) chloride, which provides an orange emission signal as internal reference, resulting in low measurement uncertainties. Using a liquid-liquid extraction protocol, this assay enables the direct detection of PFOA in environmental water samples and achieves a detection limit of 0.11 µM. Integration into an opto-microfluidic system enables a compact and user-friendly system for detecting PFOA in less than 15 minutes. KW - PFAS KW - Molecular imprinting KW - Microfluidics KW - Fluorescence KW - Onsite assay PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-650270 DO - https://doi.org/10.1038/s41467-025-66872-9 SN - 2041-1723 VL - 16 IS - 1 SP - 1 EP - 16 PB - Springer Science and Business Media LLC AN - OPUS4-65027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mansurova, Maria A1 - Johann, Sergej A1 - Kohlhoff, Harald A1 - Rurack, Knut A1 - Bartholmai, Matthias A1 - Bell, Jérémy T1 - On-Site Analytical Tool Based on Crude Oil Fluorescence and Chemometrics for the Rapid Determination of the Nature and Essential Properties of Oil Spills N2 - With the reduction of large oil spills because of stricter regulations and safety measures, the question of how to manage smaller oil spills arises. Few on-site analytical tools are available for first responders or other law enforcement personnel to rapidly test for crude oil in the early management of localized polluted areas. The approach reported here relies on well-described computer-assisted multivariate data analysis of the intrinsic fluorescence fingerprints of crude oils to build a multivariate model for the rapid classification of crude oils and the prediction of their properties. Thanks to a dedicated robust portable reader, the method allowed classification and accurate prediction of various properties of crude oil samples like density (according to API, the American Petroleum Institute and viscosity as well as composition parameters such as volume fractions of paraffins or aromatics. In this way, autonomous operation in on-site or in-the-field applications becomes possible based on the direct (undiluted and untreated) measurement of samples and a rapid, tablet-operated readout system to yield a robust and simple analytical test with superior performance. Testing in real-life scenarios allowed the successful classification and prediction of a number of oil spill samples as well as weathered samples that closely resemble samples collected by first responders. KW - Oil spills KW - Fluorescence KW - PCA KW - Petroleum KW - Rapid test KW - Portable PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-595442 DO - https://doi.org/10.1021/acsestwater.3c00648 VL - 4 IS - 2 SP - 621 EP - 627 PB - American Chemical Society (ACS) AN - OPUS4-59544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sun, Yijuan A1 - Gawlitza, Kornelia A1 - Valderrey, Virginia A1 - Bell, Jérémy A1 - Rurack, Knut T1 - Polymerizable BODIPY probe crosslinker for the molecularly imprinted polymer-based detection of organic carboxylates via fluorescence N2 - This contribution reports the development of a polymerizable BODIPY-type fluorescent probe targeting small-molecule carboxylates for incorporation into molecularly imprinted polymers (MIPs). The design of the probe crosslinker includes a urea recognition site p-conjugated to the 3-position of the BODIPY core and two methacrylate moieties. Titration experiments with a carboxylate-expressing antibiotic, levofloxacin (LEVO), showed a blue shift of the absorption band as well as a broadening and decrease in emission, attributed to hydrogen bonding between the probe’s urea group and the carboxylate group of the antibiotic. Using this probe crosslinker, core–shell particles with a silica core and a thin MIP shell were prepared for the detection of LEVO. The MIP exhibited highly selective recognition of LEVO, with an imprinting factor of 18.1 compared to the non-imprinted polymer. Transmission electron microscopy confirmed the core–shell structure and spectroscopic studies revealed that the receptor’s positioning leads to a unique perturbation of the polymethinic character of the BODIPY chromophore, entailing the favourable responses. These features are fully preserved in the MIP, whereas no such response was observed for competitors such as ampicillin. The sensory particles allowed to detect LEVO down to submicromolar concentrations in dioxane. We have developed here for the first time a BODIPY probe for organic carboxylates and incorporated it into polymers using the imprinting technique, paving the way for BODIPY-type fluorescent MIP sensors. KW - Fluorescence KW - BODIPY probe KW - Molecularly Imprinted Polymers KW - Sensor Materials KW - Dyes KW - Water analysis KW - Advanced materials PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-598629 DO - https://doi.org/10.1039/D3MA00476G SP - 1 EP - 11 PB - Royal Society of Chemistry (RSC) AN - OPUS4-59862 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wen, Keqing A1 - Gorbushina, Anna A1 - Schwibbert, Karin A1 - Bell, Jérémy T1 - Microfluidic platform with precisely controlled hydrodynamic parameters and integrated features for generation of microvortices to accurately form and monitor biofilms in flow N2 - Microorganisms often live in habitats characterized by fluid flow, and their adhesion to surfaces in industrial systems or clinical settings may lead to pipe clogging, microbially influenced corrosion, material deterioration, food spoilage, infections, and human illness. Here, a novel microfluidic platform was developed to investigate biofilm formation under precisely controlled (i) cell concentration, (ii) temperature, and (iii) flow conditions. The developed platform central unit is a single-channel microfluidic flow cell designed to ensure ultrahomogeneous flow and condition in its central area, where features, e.g., with trapping properties, can be incorporated. In comparison to static and macroflow chamber assays for biofilm studies, microfluidic chips allow in situ monitoring of biofilm formation under various flow regimes and have better environment control and smaller sample requirements. Flow simulations and experiments with fluorescent particles were used to simulate bacteria flow in the platform cell for calculating flow velocity and direction at the microscale level. The combination of flow analysis and fluorescent strain injection in the cell showed that microtraps placed at the center of the channel were efficient in capturing bacteria at determined positions and to study how flow conditions, especially microvortices, can affect biofilm formation. The microfluidic platform exhibited improved performances in terms of homogeneity and robustness for in vitro biofilm formation. We anticipate the presented platform to be suitable for broad, versatile, and high-throughput biofilm studies at the microscale level. KW - Topographical pattern KW - E. coli KW - Fluorescence KW - Bacteria trapping KW - Particle velocimetry PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-610450 DO - https://doi.org/10.1021/acsbiomaterials.4c00101 SN - 2373-9878 VL - 10 IS - 7 SP - 4626 EP - 4634 PB - ACS Publ. CY - Washington, DC AN - OPUS4-61045 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -