TY - JOUR A1 - Dietrich, Paul A1 - Streeck, C. A1 - Glamsch, Stephan A1 - Ehlert, Christopher A1 - Lippitz, Andreas A1 - Nutsch, A. A1 - Kulak, N. A1 - Beckhoff, B. A1 - Unger, Wolfgang T1 - Quantification of silane molecules on oxidized silicon: Are there options for a traceable and absolute determination? N2 - Organosilanes are used routinely to functionalize various support materials for further modifications. Nevertheless, reliable quantitative information about surface functional group densities after layer formation is rarely available. Here, we present the analysis of thin organic nanolayers made from nitrogen containing silane molecules on naturally oxidized silicon wafers with reference-free total reflection X-ray fluorescence (TXRF) and X-ray photoelectron spectroscopy (XPS). An areic density of 2−4 silane molecules per nm2 was calculated from the layer’s nitrogen mass deposition per area unit obtained by reference-free TXRF. Complementary energy and angle-resolved XPS (ER/ARXPS) in the Si 2p core-level region was used to analyze the outermost surface region of the organic (silane layer)−inorganic (silicon wafer) interface. Different coexisting silicon species as silicon, native silicon oxide, and silane were identified and quantified. As a result of the presented proof-of-concept, absolute and traceable values for the areic density of silanes containing nitrogen as intrinsic marker are obtained by calibration of the XPS methods with reference-free TXRF. Furthermore, ER/AR-XPS is shown to facilitate the determination of areic densities in (mono)layers made from silanes having no heteroatomic marker other than silicon. After calibration with reference-free TXRF, these areic densities of silane molecules can be determined when using the XPS component intensity of the silane’s silicon atom. PY - 2015 DO - https://doi.org/10.1021/acs.analchem.5b02846 SN - 0003-2700 SN - 1520-6882 VL - 87 IS - 19 SP - 10117 EP - 10124 PB - American Chemical Society CY - Washington, DC AN - OPUS4-34796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hornemann, A. A1 - Eichert, D. A1 - Flemig, Sabine A1 - Ulm, G. A1 - Beckhoff, B. T1 - Qualifying label components for effective biosensing using advanced high-throughput SEIRA methodology N2 - The need for technological progress in bio-diagnostic assays of high complexity requires both fundamental research and constructing efforts on nano-scaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. Nanoparticle induced sensitivity enhancement and its application related to multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are well suitable for these purposes. The potential of diverse fluorophore–antibody conjugates, being chemisorbed onto low-cost gold nanoparticulate SEIRA substrates, has been explored with respect to their spectral discriminability. These novel biolabels deliver molecular SEIRA fingerprints that have been successfully analyzed by both uni- and multivariate analyzing tools, to discriminate their multiplexing capabilities. We show that this robust spectral encoding via SEIRA fingerprints opens up new opportunities for a fast, reliable and multiplexed high-end screening in biodiagnostics. KW - SEIRA methodology KW - bio-diagnostic KW - nanotechnology PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351389 DO - https://doi.org/10.1039/C4CP05944A SN - 1463-9076 SN - 1463-9084 VL - 17 IS - 14 SP - 9471 EP - 9479 PB - The Royal Soc. of Chemistry CY - Cambridge AN - OPUS4-35138 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kayser, Y. A1 - Gross, A. A1 - Hönicke, P. A1 - Osan, J. A1 - Pollakowski-Herrmann, B. A1 - Seeger, Stefan A1 - Beckhoff, B. T1 - Reliable chemical analysis of aerosols by reference-free X-ray spectrometry for monitoring airborne particulate matter N2 - The physical and chemical analysis of aerosols using reliable and physically traceable methods is important for the thorough investigation of airborne particles to support a better understanding of their origin as well as their health and climate impacts. Within the European Metrology Research AeroMet project,the aim of hysikalisch–Technische Bundesanstalt’s (PTB) X-ray spectrometry group is to develop and establish traceable and reliable X-ray methods to measure the elemental mass deposition per unit area, the elemental composition,and the chemical binding state of particulate matter supported by a flat substrate. This approach can substantially contribute to support quantitative analytical methods during on-site measurement campaigns where portable Instrumentation is employed by qualifying suitable calibration samples for commercial analytical X-ray instruments and by investigating samples collected during the field campaign. KW - AEROMET project KW - X-Ray analysis KW - TXRF KW - Aerosols KW - Particles KW - Air pollution KW - Elemental composition PY - 2020 UR - https://www.spectroscopyonline.com/view/reliable-chemical-analysis-of-aerosols-by-reference-free-x-ray-spectrometry-for-monitoring-airborne-particulate-matter SN - 0887-6703 VL - 35 IS - 10 SP - 42 EP - 46 PB - MJH Life Sciences CY - Cranbury, NJ AN - OPUS4-53357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Osan, J. A1 - Czömpöly, O. A1 - Gross, A. A1 - Stosnach, H. A1 - Stabile, L. A1 - Ochsenkuehn-Petropoulou, M. A1 - Tsakanika, L. A1 - Lymperopoulou, T. A1 - Goddard, S. A1 - Fiebig, M. A1 - Gaie-Levrel, F. A1 - Kayser, Y. A1 - Beckhoff, B. T1 - Quantification of Element Mass Concentrations in Ambient Aerosols by Combination of Cascade Impactor Sampling and Mobile Total Reflection X-ray Fluorescence Spectroscopy N2 - Quantitative chemical analysis of airborne particulate matter (PM) is vital for the understanding of health effects in indoor and outdoor environments, as well as for enforcing EU air quality regulations. Typically, airborne particles are sampled over long time periods on filters, followed by lab-based analysis, e.g., with inductively coupled plasma mass spectrometry (ICP-MS). During the EURAMET EMPIR AEROMET project, cascade impactor aerosol sampling is combined for the first time with on-site total reflection X-ray fluorescence (TXRF) spectroscopy to develop a tool for quantifying particle element compositions within short time intervals and even on-site. This makes variations of aerosol chemistry observable with time resolution only a few hours and with good size resolution in the PM10 range. The study investigates the proof of principles of this methodological approach. Acrylic discs and silicon wafers are shown to be suitable impactor carriers with sufficiently smooth and clean surfaces, and a non-destructive elemental mass concentration measurement with a lower limit of detection around 10 pg/m3 could be achieved. We demonstrate the traceability of field TXRF measurements to a radiometrically calibrated TXRF reference, and the results from both analytical methods correspond satisfactorily. KW - TXRF KW - Reference method KW - Cascade impactor KW - Ambient aerosols KW - Particles KW - Air quality monitoring KW - Element mass concentration KW - Size resolved chemical composition KW - Time resolved chemical composition KW - ICP-MS PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-521860 UR - http://www.aerometproject.com/ DO - https://doi.org/10.3390/atmos12030309 SN - 2073-4433 VL - 12 IS - 3 SP - 309 EP - 337 PB - MDPI CY - Basel, Schweiz AN - OPUS4-52186 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Streeck, C. A1 - Wirth, Thomas A1 - Unger, Wolfgang A1 - Beckhoff, B. T1 - Qualifying calibration samples for advanced thin film materials characterisation N2 - In this article the question of the certification of calibration samples for the characterisation of advanced thin film materials is addressed within the framework of reliable process control or quality management purposes. Reference measurement techniques can be used in order to address the gap in appropriate certified reference materials (CRMs) for thin film analyses. They allow for qualifying out-of-production samples originating from an operating production line as calibration samples. As a template for this procedure, CIGS [Cu(In,Ga)Se2] layers, that are absorber layers for high efficiency thin-film solar cells, have been used for establishing and validating reference-free X-ray fluorescence (XRF) analysis and Auger-electron spectroscopy (AES) as reference measurement techniques. The focus was on determining the average mole fractions in the CIGS layers obtaining results traceable to the SI unit system. Reference-free XRF is physically traceable and is based upon radiometrically calibrated instrumentation and knowledge of atomic fundamental data. Sputter-assisted AES can be established as a chemically traceable method after careful calibration using a certified reference material (CRM) based on a total number counting method. KW - CIGS KW - X-ray fluorescence (XRF) KW - Auger-electron spectroscopy (AES) PY - 2018 UR - https://www.spectroscopyeurope.com/article/qualifying-calibration-samples-advanced-thin-film-materials-characterisation VL - 30 IS - 1 SP - 11 EP - 14 PB - John Wiley & Sons Ltd CY - Chichester, West Sussex PO19 8SQ, UK AN - OPUS4-44260 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grötzsch, D. A1 - Streeck, C. A1 - Nietzold, Carolin A1 - Malzer, W. A1 - Mantouvalou, I. A1 - Nutsch, A. A1 - Dietrich, Paul A1 - Unger, Wolfgang A1 - Beckhoff, B. A1 - Kanngießer, B. T1 - A sealable ultrathin window sample cell for the study of liquids by means of soft X-ray spectroscopy N2 - A new sample cell concept for the analysis of liquids or solid-liquid interfaces using soft X-ray spectroscopy is presented, which enables the complete sealing of the cell as well as the Transport into vacuum via, for example, a load-lock system. The cell uses pressure monitoring and active as well as passive pressure regulation systems, thereby facilitating the full control over the pressure during filling, sealing, evacuation, and measurement. The cell design and sample preparation as well as the crucial sealing procedure are explained in detail. As a first proof-of-principle experiment, successful nitrogen K-edge fluorescence yield near-edge X-ray absorption fine structure experiments of a biomolecular solution are presented. For this purpose, it is shown that the careful evaluation of all involved parameters, such as window type or photon flux, is desirable for optimizing the experimental result. KW - X-ray spectroscopy KW - Analysis of liquids KW - Wet cell KW - Concanavalin A KW - NEXAFS PY - 2017 DO - https://doi.org/10.1063/1.5006122 SN - 0034-6748 SN - 1089-7623 VL - 88 IS - 12 SP - 123112-1 EP - 123112-7 PB - American Institute of Physics AN - OPUS4-43611 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hornemann, A. A1 - Eichert, D. A1 - Flemig, Sabine A1 - Hoehl, A. A1 - Ulm, G. A1 - Beckhoff, B. ED - Shen, Q. ED - Nelson, C. T1 - Probing biolabels for high throughput biosensing via synchrotron radiation SEIRA technique N2 - Bio-diagnostic assays of high complexity rely on nanoscaled assay recognition elements that can provide unique selectivity and design-enhanced sensitivity features. High throughput performance requires the simultaneous detection of various analytes combined with appropriate bioassay components. Nanoparticle induced sensitivity enhancement, and subsequent multiplexed capability Surface-Enhanced InfraRed Absorption (SEIRA) assay formats are fitting well these purposes. SEIRA constitutes an ideal platform to isolate the vibrational signatures of targeted bioassay and active molecules. The potential of several targeted biolabels, here fluorophore-labeled antibody conjugates, chemisorbed onto low-cost biocompatible gold nano-aggregates substrates have been explored for their use in assay platforms. Dried films were analyzed by synchrotron radiation based FTIR/SEIRA spectro-microscopy and the resulting complex hyperspectral datasets were submitted to automated statistical analysis, namely Principal Components Analysis (PCA). The relationships between molecular fingerprints were put in evidence to highlight their spectral discrimination capabilities. We demonstrate that robust spectral encoding via SEIRA fingerprints opens up new opportunities for fast, reliable and multiplexed high-end screening not only in biodiagnostics but also in vitro biochemical imaging. T2 - 12th International Conference on Synchrotron Radiation Instrumentation (SRI) CY - New York, NY, USA DA - 06.07.2015 KW - Biolabels KW - High throughput biosensing KW - Synchrotron radiation KW - SEIRA Technique PY - 2016 DO - https://doi.org/10.1063/1.4952927 VL - 1741 SP - Article Number: 050007 PB - AIP Conference Proceedings AN - OPUS4-40113 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mantler, M. A1 - Beckhoff, B. T1 - Reference-Free X-Ray flourescence analysis: Part 2: Theoretical considerations T2 - TECHNART 2007, Non-destructive and Techniques in Art and Cultural Heritage Research CY - Lisbon, Portugal DA - 2007-04-25 PY - 2007 AN - OPUS4-15025 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hahn, Oliver A1 - Malzer, W. A1 - Kanngießer, B. A1 - Beckhoff, B. T1 - Characterization of iron-gall inks in historical manuscripts and music compositions using x-ray fluorescence spectrometry N2 - The qualitative and quantitative investigation of historical iron-gall inks using micro-XRF spectrometry is a suitable method for analyzing composition fingerprints of different ink types. The quantitative analysis is based on a model that takes into account the inhomogeneity and the layer structure of archaeometric samples. Starting from these composition fingerprints, it is possible to characterize distinguishable inks of one artist to classify different chronological ink types and, further, to date unknown fragments that have not so far been integrated into the lifework of an artist. The first qualitative and quantitative investigations of the manuscript Faust I and II and of the music composition The Magic Flute demonstrate impressively the identification of J. W. v. Goethe's and W. A. Mozart's artistic work with modern scientific methods. Further investigations on A. v. Arnim's manuscript Studien zu Naturwissenschaften provide evidence that the diversity of various degradation mechanisms of iron-gall inks could be mainly caused by different inorganic compositions. PY - 2004 DO - https://doi.org/10.1002/xrs.677 SN - 0049-8246 VL - 33 SP - 234 EP - 239 PB - Wiley CY - Chichester AN - OPUS4-3723 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beckhoff, B. A1 - Hahn, Oliver T1 - Encviromental Analyses by TXRF-NEXAFS and IR-spectroscopy: Speciation of Bromine in Organics and Characterization of the Organic Matrix T2 - VVIII INternational Bonderence on "X-ray Optics and MIcroanlaysis" CY - Frascati, Italy DA - 2005-09-25 PY - 2005 AN - OPUS4-10543 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -