TY - GEN A1 - Sauer, Andreas A1 - Buttler, Sabine A1 - Becker, Roland T1 - Bericht zum 24. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik: Polychlorierte Biphenyle (PCB) in Boden, Mineralölkohlenwasserstoffe (MKW) in Boden, Elemente in Boden und Gesamtcyanid in Boden. KW - Spurenelemente KW - Boden KW - Gesamtcyanid KW - Eignungsprüfung KW - MKW KW - PCB PY - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-473418 SP - 1 EP - 183 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-47341 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Sauer, Andreas A1 - Bremser, Wolfram T1 - Fifteen years of proficiency testing of total petrol hydrocarbon determination in soil: a story of success N2 - The total petrol hydrocarbon (TPH) content in soil is determined by gas chromatographic separation and flame ionisation detection according to ISO 16703 in routine laboratories for about 20 years. The development of the interlaboratory variability observed with this analytical procedure over 15 years in a proficiency testing scheme conducted annually with more than 170 participants is evaluated in detail. A significant improvement of the reproducibility standard deviation among participants is observed over the years and attributed to an increasing familiarity with the procedure. Nevertheless, the determination of TPH in the environmentally relevant mass fraction range between 500 mg/kg and 10 000 mg/kg in soils or sediments is far from reaching the reproducibility standard deviations predicted by the Horwitz curve. It is seen that laboratories with sporadic participation tend to report higher bias, while a core group of laboratories participating on a regular basis arrived at reproducibility standard deviations below 20 %. Results from a given laboratory obtained on two different samples tend to be highly correlated in the same PT round indicating a sound repeatability. Expectedly, the within-laboratory correlation between results from consecutive rounds was considerably lower. However, results from consecutive rounds with a temporal distance of 1, 2 or 3 years revealed largely similar correlations which suggests that the within-laboratory reproducibility adjusts to a constant level at least after a period of 1 year. KW - Mineralölkohlenwasserstoffe KW - Boden KW - Ringversuch KW - Gaschromatographie KW - GC-FID KW - Eingnugsprüfung KW - Proficiency Testing PY - 2019 U6 - https://doi.org/10.1007/s00769-019-01383-x SN - 0949-1775 SN - 1432-0517 VL - 24 IS - 4 SP - 289 EP - 296 PB - Springer AN - OPUS4-48419 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -