TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 20. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - MKW KW - PAK KW - Spurenelemente KW - Chrom(VI) KW - Proficiency testing KW - Soil KW - TPH KW - PAH KW - Trace elements KW - Chromium(VI) PY - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-356424 SP - 1 EP - 228 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35642 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 19. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - MKW KW - PAK KW - Gesamtcyanid KW - Spurenelemente KW - Proficiency testing KW - Soil KW - TPH KW - PAH KW - Total cyanide KW - Trace elements PY - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-356963 SP - 1 EP - 233 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35696 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 18. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - MKW KW - PAK KW - Gesamtcyanid KW - Spurenelemente KW - Proficiency testing KW - Soil KW - TPH KW - PAH KW - Total cyanide KW - Trace elements PY - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-357399 SP - 1 EP - 226 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35739 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 21. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - PAK KW - MKW KW - Spurenelemente KW - Gesamtcyanid KW - Proficiency testing KW - Soil KW - PAH KW - TPH KW - Trace elements KW - Total cyanide PY - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-355586 SP - 1 EP - 234 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35558 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sauer, Andreas A1 - Scharf, Holger A1 - Becker, Roland T1 - Bericht zum 17. BAM-Ringversuch "Altlasten" N2 - Präsentation der Ergebnisse eines Ringversuchs zur Kompetenzbewertung von Prüflaboratorien auf dem Gebiet der anorganischen und organischen Bodenanalytik. KW - Eignungsprüfung KW - Boden KW - PAK KW - MKW KW - AOX KW - Spurenelemente KW - Gesamtcyanid KW - Proficiency testing KW - Soil KW - PAH KW - TPH KW - Trace elements KW - Total cyanide PY - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-357785 SP - 1 EP - 212 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-35778 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Sporkert, F. A1 - Lô, I. A1 - Baumgartner, M. T1 - The determination of ethyl glucuronide in hair: Experiences from nine consecutive interlaboratory comparison rounds N2 - The increasing request for hair ethyl glucuronide (HEtG) in alcohol consumption monitoring according to cut-off levels set by the Society of Hair Testing (SoHT) has triggered a proficiency testing program based on interlaboratory comparisons (ILC). Here, the outcome of nine consecutive ILC rounds organised by the SoHT on the determination of HEtG between 2011 and 2017 is summarised regarding interlaboratory reproducibility and the influence of procedural variants. Test samples prepared from cut hair (1 mm) with authentic (in-vivo incorporated) and soaked (in-vitro incorporated) HEtG concentrations up to 80 pg/mg were provided for 27–35 participating laboratories. Laboratory results were evaluated according to ISO 5725-5 and provided robust averages and relative reproducibility standard deviations typically between 20 and 35% in reasonable accordance with the prediction of the Horwitz model. Evaluation of results regarding the analytical techniques revealed no significant differences between gas and liquid chromatographic methods In contrast, a detailed evaluation of different sample preparations revealed significantly higher average values in case when pulverised hair is tested compared to cut hair. This observation was reinforced over the different ILC rounds and can be attributed to the increased acceptance and routine of hair pulverisation among laboratories. Further, the reproducibility standard deviations among laboratories performing pulverisation were on average in very good agreement with the prediction of the Horwitz model. Use of sonication showed no effect on the HEtG extraction yield. KW - Ethyl glucuronide KW - Interlaboratory comparison KW - Proficiency testing KW - Society of hair testing KW - Reproducibility KW - Pulverization PY - 2018 U6 - https://doi.org/10.1016/j.forsciint.2018.04.025 SN - 0379-0738 SN - 1872-6283 VL - 288 SP - 67 EP - 71 PB - Elsevier AN - OPUS4-44881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Nehls, Irene A1 - Dorgerloh, Ute T1 - Interlaboratory comparisons - demonstrating degree of equivalence N2 - The role of matrix reference materials in the process of demonstrating the degree of equivalence of measurement results obtained from intercomparisons is outlined, reviewing exemplary selected experience gained at BAM regarding the determination of organic contaminants in environmental matrices. The specific characteristics of reference materials employed in the process of demonstrating equivalence between laboratories in the course of proficiency testing as well as the development, comparison and validation of methods are elaborated. The demand is for series of appropriately characterised samples which are fit for the purpose and it is seen from representative examples that the utilisation of such tailor-made RM designed to tackle the specific need of an analytical problem dominates over certified matrix reference materials in this context. Concluding, the role of certified matrix reference materials in quality assurance is briefly looked at both from the user’s and providers’ points of view. KW - Certification KW - Equivalence KW - Method development KW - Proficiency testing KW - Reference materials PY - 2003 U6 - https://doi.org/10.1007/s00769-003-0580-5 SN - 0949-1775 SN - 1432-0517 VL - 8 SP - 150 EP - 155 PB - Springer CY - Berlin AN - OPUS4-2848 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Buge, Hans-Gerhard A1 - Nehls, Irene T1 - The determination of adsorbable organically bound halogens (AOX) in soil: interlaboratory comparisons and reference materials N2 - The interlaboratory variability in the quantification of adsorbable organically bound halogens (AOX) in industrially contaminated soil is presented. Three consecutive rounds of a proficiency testing scheme, in which between 88 and 119 routine laboratories participated, yielded relative reproducibility standard deviations between 7 and 20% at AOX contents between 10.9 and 268 mg kg-1. Nineteen laboratories with established proficiency were invited to participate in the certification of the AOX content in three soil reference materials meant for the internal quality control in analytical laboratories. The certified values are (1349 ± 59) mg kg-1, (80 ± 7) mg kg-1 and (102 ± 8) mg kg-1, respectively. KW - Certified reference materials KW - European Reference Material KW - Proficiency testing KW - Organohalogen compounds KW - Summation parameter PY - 2007 U6 - https://doi.org/10.1007/s00769-007-0308-z SN - 0949-1775 SN - 1432-0517 VL - 12 IS - 12 SP - 647 EP - 651 PB - Springer CY - Berlin AN - OPUS4-16670 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -