TY - JOUR A1 - Becker, Roland A1 - Buge, Hans-Gerhard A1 - Win, Tin T1 - Determination of pentachlorphenol (PCP) in waste wood - method comparison by a collaborative trial N2 - Two independently developed and validated procedures for the determination of pentachlorophenol (PCP) in waste wood were compared by means of a collaborative trial. Both methods foresee quantification of PCP by gas chromatography (GC-ECD) after acetylation and differ with regard to the use of methanol or toluene/sulphuric acid, respectively, as solvent in the sonication extraction step. Test samples with established analyte homogeneity were prepared from a ground “real life” starting material. A total of 23 participating laboratories with experience in wood preservative analysis were instructed to apply both methods to three levels of content in the range of 0.5–20 mg PCP/kg. In case of the toluene/sulphuric acid extraction, lower recoveries and higher interlaboratory dispersion of results at the higher PCP contents were observed. Seen against the background of the Horwitz equation a reproducibility standard deviation of not, vert, similar19% for the methanol extraction at the 4.5 mg/kg level meets the requirement for a sound analytical method. Thus, the sonication extraction procedure with methanol has been annexed as a reference method to the German waste wood regulation. KW - Extraction KW - Derivatisation KW - Sonication KW - Analysis KW - Gas chromatography KW - Regulation PY - 2002 U6 - https://doi.org/10.1016/S0045-6535(02)00004-8 SN - 0045-6535 SN - 0366-7111 VL - 47 SP - 1001 EP - 1006 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-1628 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppen, Robert A1 - Becker, Roland A1 - Jung, Christian A1 - Piechotta, Christian A1 - Nehls, Irene T1 - Investigation of extraction procedures and HPLC-DAD/MS for the determination of the brominated flame retardant tetrabromobisphenol A bis(2,3-dibromopropylether) in environmental samples N2 - A method for the determination of the novel brominated flame retardant tetrabromobisphenol A bis(2,3-dibromopropylether), 1,1'-(isopropylidene)bis[3,5-dibromo-4-(2,3-dibromo-propoxy)-benzene] (TBBPA-dbpe), was developed. Technical TBBPA-dbpe was purified and the results of a thorough physical characterisation are reported. The application of APCI-MS is discussed and the fragmentation patterns are described. Quantification of TBBPA-dbpe was done by HPLC-DAD using external calibration. The validation of the method was accomplished using sediment and sewage sludge samples spiked with defined amounts of authentic TBBPA-dbpe. The average recovery rates of TBBPA-dbpe from spiked samples ranged from 35 to 91% (sediment) and from 57 to 98% (sewage sludge) depending on the respective extraction method. Pressurised fluid extraction (PFE) and fluidised bed extraction were superior to classical Soxhlet and sonication procedures and yielded recovery rates between 90 and 98% with relative standard deviations of 2%. The limits of detection (DTC), identification (ID) and determination (DTM) using HPLC-DAD were 10, 21 and 30 ng g-1 in sediment and 22, 44 and 72 ng g-1 in sewage sludge, respectively. KW - Extraction KW - TBBPA-dbpe KW - Sewage sludge KW - Sediment KW - LC-MS KW - Mass spectrometry KW - APCI KW - HPLC-DAD PY - 2006 U6 - https://doi.org/10.1007/s00216-006-0339-z SN - 1618-2642 SN - 1618-2650 VL - 384 IS - 7-8 SP - 1485 EP - 1492 PB - Springer CY - Berlin AN - OPUS4-12255 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Becker, Roland A1 - Jung, Christian A1 - Nehls, Irene T1 - The homogeneity testing of EtG in hair reference materials: A high-throughput procedure using GC-NCI-MS N2 - The validation of a robust quantification procedure for EtG in hair using GC–NCI–MS is presented. Aqueous extraction is followed by complete lyophylization of the extract and derivatization with pentafluoropropionic anhydride (PFPA) under controlled temperature and duration. Clean-up of extracts was dispensable and standard single quadrupole MS displayed sufficient selectivity and sensitivity. The method displayed a wide linearity range and enabled LOD of 0.68 pg/mg, LOQ of 2.4 pg/mg, and precision below 8.12%. Since EtG was seen to display prolonged stability in the aqueous extracts and after derivatization with PFPA this straightforward procedure allows a routine throughput of large quantities of samples with little proneness to procedural scatter of results. The method was applied to demonstrate the homogeneity of two hair reference materials with mean EtG contents of 8.48 pg/mg and 22.0 pg/mg. Aside from the application in homogeneity studies of hair reference materials predominantly in the concentration range of 10–50 pg/mg the method was also designed for daily routine quantification of real-world sample with regard to drinking behavior assessment. KW - Extraction KW - Derivatization KW - High-throughput analysis KW - Reference materials KW - Homogeneity KW - Measurement uncertainty PY - 2013 U6 - https://doi.org/10.1016/j.forsciint.2013.01.018 SN - 0379-0738 SN - 1872-6283 VL - 226 IS - 1-3 SP - 202 EP - 207 PB - Elsevier Ltd. CY - Amsterdam [u.a.] AN - OPUS4-27998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Buge, Hans-Gerhard A1 - Bremser, Wolfram A1 - Nehls, Irene T1 - Mineral oil content in sediments and soils: comparability, traceability and a certified reference material for quality assurance N2 - The performance of twelve laboratories with previously established proficiency in the determination of the mineral oil content in a fresh water sediment is described. The summation parameter total petrol hydrocarbon (TPH) is defined according to ISO 16703:2004 with regard to the sample preparation to be applied, the flame ionisation detection (FID) and the boiling range of C10–C40 to be integrated. Comprehensive tests of homogeneity and stability have been carried out on the candidate material using appropriate models. The outcome of the study served as the basis for the certification of the candidate reference material as ERM-CC015a. The certified mass fraction is 1,820±130mgkg-1 and traceability was established by using an appropriate calibration standard certified for the mass fraction of C10–C40. The interlaboratory scatter of measurement results in this exercise can largely be explained by the variability of the individual calibrations based on this common calibration standard. KW - Total petroleum hydrocarbons KW - Extraction KW - Gas chromatography KW - Calibration KW - Interlaboratory study PY - 2006 U6 - https://doi.org/10.1007/s00216-006-0423-4 SN - 1618-2642 SN - 1618-2650 VL - 385 IS - 3 SP - 645 EP - 651 PB - Springer CY - Berlin AN - OPUS4-12399 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Heyn, L. A1 - Jung, Christian T1 - Indoor exposure to airborne polycyclic aromatic hydrocarbons: A comparison of stir bar sorptive extraction and pump sampling N2 - Stir bar sorptive extraction (SBSE) was compared with standardized pump sampling regarding the prospects to assess airborne levels of polycyclic aromatic hydrocarbons (PAHs) in indoor environments. A historic railway water tower, which will be preserved as a technical monument for museum purposes, was sampled with both approaches because the built-in insulationmaterial was suspected to release PAHs to the indoor air. The 16 PAHs on the US EPA list were quantified using gas chromatography with mass spectrometric detection in filters from pump sampling after solvent extraction and on SBSE devices after thermal desorption. SBSEwas seen to sample detectable PAHmasseswith excellent repeatability and a congener pattern largely similar to that observed with pump sampling. Congener patterns were however significantly different from that in the PAH source because release from the insulation material is largely triggered by the respective congener vapor pressures. Absolute masses in the ng range sampled by SBSE corresponded to airborne concentrations in the ng L−1 range determined by pump sampling. Principle differences between SBSE and pump sampling as well as prospects of SBSE as cost-effective and versatile complement of pump sampling are discussed. KW - Polycyclic aromatic hydrocarbons KW - Adsorption KW - Extraction KW - Indoor air PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-537427 VL - 3 IS - 12 SP - 1 EP - 10 PB - John Wiley & Sons Ltd. AN - OPUS4-53742 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -