TY - CONF A1 - Schultze, Karin A1 - Nehls, Irene A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Win, Tin T1 - Zertifiziertes Referenzmaterial "BAM-U007" - Organochlorpestizide in Boden T2 - ANAKON 2001 CY - Konstanz, Germany DA - 2001-04-04 PY - 2001 SP - 1(?) AN - OPUS4-1314 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Volatile hydrocarbons in contaminated soil: Robustness of fractional quantification using headspace gas chromatography-mass-spectrometry N2 - Fuel contamination of soils display complex and variable hydrocarbon mixtures with different volatility and toxicity characteristics. A recently suggested headspace procedure for the structure-based quantification of volatile hydrocarbons is evaluated regarding repeatability, reproducibility, and practical robustness. Three aliphatic and three aromatic fractions covering the boiling range between 69 and 216°C were defined as summation parameters by their respective equivalent carbon number ranges. A standard mixture of 35 aliphatic and aromatic hydrocarbons was used for calibration on basis of selected mass fragments specific for the aliphatics and aromatics, respectively. Two standard soils were fortified with the standard mixture or different fuels, respectively, and submitted to the analytical procedure. Limit of detection (LOD) and limit of quantification (LOQ) were for all fractions lower than 0.1 and 0.3 mg/kg, respectively. Analyte recovery was linear up to between 20 and 110 mg hydrocarbons/kg soil depending on the fraction. Hydrocarbon recovery ranged between 80% and 110% depending on the fraction and the repeatability was typically better than 10%. Finally, the impact of extraction solvent variation, column solid-phase polarity, and alternative summation of fractions were investigated. The procedure was applied to liner samples taken from a site contaminated with aviation fuel and its practicability is discussed. KW - Gasoline KW - Contaminated site KW - Equivalent carbon number KW - Fuel KW - Static headspace PY - 2018 U6 - https://doi.org/10.1080/15320383.2018.1418287 SN - 1532-0383 SN - 1549-7887 VL - 27 IS - 1 SP - 1 EP - 12 PB - Taylor & Francis AN - OPUS4-43889 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Jung, Christian A1 - Schröter-Kermani, C. A1 - Nehls, Irene T1 - Time courses of HBCD levels and enantiomeric signatures in herring gull eggs from the German coast T2 - Dioxin 2010 - 30th International symposium on halogenated persistent organic pollutants CY - San Antonio, TX, USA DA - 2010-09-12 PY - 2010 UR - http://www.dioxin20xx.org/pdfs/2010/10-1112.pdf N1 - Serientitel: Organohalogen Compounds – Series title: Organohalogen Compounds VL - 72 SP - 255 EP - 258 AN - OPUS4-23167 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. A1 - Nehls, Irene T1 - The quantification of hydrogen and methane in contaminated groundwater: validation of robust procedures for sampling and quantification N2 - A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM. PY - 2010 U6 - https://doi.org/10.1039/c0em00091d SN - 1464-0325 SN - 1464-0333 VL - 12 IS - 10 SP - 1876 EP - 1884 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-22176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Buge, Hans-Gerhard A1 - Becker, Roland A1 - Nehls, Irene T1 - The preparation and characterization of solid matrix reference materials for the trace analysis of organic environmental pollutants - relevant aspects of quality management N2 - Feste Referenzmaterialien für die Spurenanalytik umweltrelevanter organischer Schadstoffe erfordern aufgrund der geringen thermischen Belastbarkeit der Analyten besondere Aufarbeitungsstrategien für die Herstellung repräsentativer Teilproben. Das in der Fachgruppe I.2 seit 1994 für diesen Zweck systematisch aufgebaute technologische Instrumentarium wird vorgestellt, und das im Laufe der Jahre angesammelte Know How wird anhand von Beispielen vermittelt. Das im Laboratorium I.21 entwickelte Qualitätssystem für eine optimale Logistik der Arbeitsabläufe der Probenherstellung und -verwaltung sowie für eine bedarfsgerechte Charakterisierung der Materialien wird ausführlich erläutert. Bezüglich der Verwendung der Referenzmaterialien wird herausgestellt, daß es zwei gleichberechtigte Anwendungsrichtungen gibt: die interne Qualitätskontrolle mit zertifizierten Referenzmaterialien (ZRM, z.B. für die Methodenvalidierung) und die externe Qualitätskontrolle (Proficiency Testing = Kompetenzbewertung von Prüflaboratorien). Referenzmaterialien für das Proficiency Testing, die im Umweltbereich in viel größeren Stückzahlen umgesetzt werden können als ZRM, weisen bezüglich Homogenität und Charakterisierung die gleichen Qualitätskriterien wie ZRM auf. Diese Materialien haben - auch im internationalen Maßstab - stark an Bedeutung gewonnen. Ein englisches Abstract gibt es nicht, aber eine Grobgliederung zur Vortragsankündigung: This lecture includes: · the technological and logistical aspects of reference material preparation and sub-sampling and subsequent sample management, · appropriate measurement strategies for homogeneity and stability studies, · the use of relevant statistical tests to evaluate those measurement data, · the organisation of interlaboratory studies based on traceable measurements T2 - CENAM CY - Querétaro, Mexico DA - 2002-03-01 PY - 2002 AN - OPUS4-1612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Becker, Roland A1 - Jung, Christian A1 - Nehls, Irene T1 - The homogeneity testing of EtG in hair reference materials: A high-throughput procedure using GC-NCI-MS N2 - The validation of a robust quantification procedure for EtG in hair using GC–NCI–MS is presented. Aqueous extraction is followed by complete lyophylization of the extract and derivatization with pentafluoropropionic anhydride (PFPA) under controlled temperature and duration. Clean-up of extracts was dispensable and standard single quadrupole MS displayed sufficient selectivity and sensitivity. The method displayed a wide linearity range and enabled LOD of 0.68 pg/mg, LOQ of 2.4 pg/mg, and precision below 8.12%. Since EtG was seen to display prolonged stability in the aqueous extracts and after derivatization with PFPA this straightforward procedure allows a routine throughput of large quantities of samples with little proneness to procedural scatter of results. The method was applied to demonstrate the homogeneity of two hair reference materials with mean EtG contents of 8.48 pg/mg and 22.0 pg/mg. Aside from the application in homogeneity studies of hair reference materials predominantly in the concentration range of 10–50 pg/mg the method was also designed for daily routine quantification of real-world sample with regard to drinking behavior assessment. KW - Extraction KW - Derivatization KW - High-throughput analysis KW - Reference materials KW - Homogeneity KW - Measurement uncertainty PY - 2013 U6 - https://doi.org/10.1016/j.forsciint.2013.01.018 SN - 0379-0738 SN - 1872-6283 VL - 226 IS - 1-3 SP - 202 EP - 207 PB - Elsevier Ltd. CY - Amsterdam [u.a.] AN - OPUS4-27998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Buge, Hans-Gerhard A1 - Nehls, Irene T1 - The determination of adsorbable organically bound halogens (AOX) in soil: interlaboratory comparisons and reference materials N2 - The interlaboratory variability in the quantification of adsorbable organically bound halogens (AOX) in industrially contaminated soil is presented. Three consecutive rounds of a proficiency testing scheme, in which between 88 and 119 routine laboratories participated, yielded relative reproducibility standard deviations between 7 and 20% at AOX contents between 10.9 and 268 mg kg-1. Nineteen laboratories with established proficiency were invited to participate in the certification of the AOX content in three soil reference materials meant for the internal quality control in analytical laboratories. The certified values are (1349 ± 59) mg kg-1, (80 ± 7) mg kg-1 and (102 ± 8) mg kg-1, respectively. KW - Certified reference materials KW - European Reference Material KW - Proficiency testing KW - Organohalogen compounds KW - Summation parameter PY - 2007 U6 - https://doi.org/10.1007/s00769-007-0308-z SN - 0949-1775 SN - 1432-0517 VL - 12 IS - 12 SP - 647 EP - 651 PB - Springer CY - Berlin AN - OPUS4-16670 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Jung, Christian A1 - Schröter-Kermani, C. A1 - Bremser, Wolfram A1 - Nehls, Irene T1 - Temporal trend (1988-2008) of hexabromocyclododecane enantiomers in herring gull eggs from the german coastal region N2 - Levels of α-, β-, and γ-hexabromocyclododecane (HBCD) were determined in pooled eggs from herring gulls (Larus argentatus) sampled on three bird sanctuaries near the German North Sea coast between 1988 and 2008 (Mellum and Trischen) and the German Baltic Sea coast between 1998 and 2008 (Heuwiese) and archived by the German Environmental Specimen Bank. Pressurized fluid extraction, gel permeation chromatography, and LC–MS/MS using 13C12-labelled isotope standards and a chiral column were applied. α-HBCD was the dominating diastereomer and ranged between 3.7 and 107 ng g-1 lw while β- and γ-HBCD were throughout close to LOQ. The highest α-HBCD concentration was found in eggs from Mellum sampled in the year 2000. Interestingly, HBCD in eggs from the three islands displayed similar time courses with levels increasing to a peak contamination around 2000 and decreasing levels ever since. Chiral signatures of α-HBCD in eggs differed among the islands but indicated a preferential enrichment of the first eluting enantiomer (-)-α-HBCD. KW - Brominated flame retardant KW - Chiral separation KW - HPLC-ESI-MS/MS KW - Enantiomer-specific bioaccumulation PY - 2011 U6 - https://doi.org/10.1016/j.chemosphere.2010.12.047 SN - 0045-6535 SN - 0366-7111 VL - 83 IS - 2 SP - 161 EP - 167 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-23351 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ammann, Dominic A1 - Becker, Roland A1 - Nehls, Irene T1 - Stability of ethyl glucuronide in hair reference materials after accelerated aging N2 - Two different hair reference materials, one produced from authentic hair displaying an ethyl glucuronide (EtG) content of about 25 pg/mg and one obtained by fortification of blank hair to an EtG level of 85 pg/mg were submitted to accelerated aging between 4 degrees C and 60 degrees C for periods between one and 24 months. Subsequently, the EtG content was determined in the aged samples and untreated reference samples stored at -22 degrees C under repeatability conditions following the so-called isochronous approach. The EtG content remained stable even at 40 degrees C for 24 months and at 60 degrees C over six months. This is in contrast to many organic analytes contained in trace concentrations in diverse matrices. A slight but significant increase of the recovered EtG in case of authentic hair samples having been exposed for 24 months between 4 degrees C and 60 degrees C may be due to a temperature-driven process that allows increased recoveries of the physiologically embedded EtG. KW - Alcohol marker KW - Micropulverization KW - HPLC-MS/MS KW - Fortification KW - Long term stability PY - 2015 U6 - https://doi.org/10.1016/j.forsciint.2015.09.015 SN - 0379-0738 SN - 1872-6283 VL - 257 SP - 337 EP - 340 PB - Elsevier Ireland Ldt. CY - Amsterdam [u.a.] AN - OPUS4-34940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Nehls, Irene T1 - Stabilisation of groundwater samples for the quantification of organic trace pollutants N2 - The concentration of contaminants in groundwater samples can be decreased by degradation in the time course between field sampling and quantification in the laboratory, especially in samples from sites where degradation activity is enhanced by remediation measures. The sampling sites covered a variety of priority organic pollutants such as volatile aromatic and chlorinated compounds, phenols and petroleum hydrocarbons and different remediation strategies such as anaerobic and aerobic microbial in situ degradation, in situ chemical oxidation, and on-site purification with biological treatment. The stability of the contaminants' concentration was investigated over a time range of several hours without cooling in the autosampler of the analytical equipment (short term) and over several days of storage until analysis (long term). A number of stabilisation techniques suggested in international standards ISO 5667-3:2013 and ASTM D6517:2000 were compared both with regard to short term and long term stabilisation of the contaminants and their practicability for field sampling campaigns. Long term storage turned out to be problematic for most compound groups even under cooling. Short term stability was problematic also for volatiles such as benzenic aromates, naphthalene and volatile organic halogenated compounds to be analysed by headspace gas chromatography. Acidification (pH <2) was sufficient to prevent degradation of benzenic aromates, naphthalene, phenols and petrol hydrocarbons for up to seven days. The use of acids was not applicable to stabilise volatiles in waters rich in carbonates and sulphides due to stripping of the volatiles with the liberated gases. The addition of sodium azide was successfully used for stabilisation of volatile organic halogenated compounds. KW - Groundwater KW - Sampling KW - Organic pollutants KW - Stabilisation KW - Analysis PY - 2013 U6 - https://doi.org/10.1039/c3em00332a SN - 2050-7887 SN - 2050-7895 VL - 15 IS - 12 SP - 2329 EP - 2337 PB - RSC Publ. CY - CambridgeRSC Publ. AN - OPUS4-29689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Ringversuche: Präparation mineralölkohlenwasserstoffhaltiger Abwasserproben KW - Analytik KW - Ringversuch KW - Abwasser KW - Mineralölkohlenwasserstoff KW - Probe KW - Qualitätssicherung KW - Chemical analysis KW - Interlaboratory comparison KW - Wastewater KW - Mineral oil KW - Sample KW - Quality assurance PY - 2008 SN - 0083-6915 VL - 106 IS - 3 SP - 7 EP - 8 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-18289 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Nehls, Irene A1 - Buge, Hans-Gerhard T1 - Referenzmaterialien für Umweltanalysen PY - 2001 SN - 0016-3538 IS - 45 SP - 1089 EP - 1091 PB - GIT-Verlag CY - Darmstadt AN - OPUS4-1186 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Koch, Matthias A1 - Lehnik-Habrink, Petra A1 - Nehls, Irene T1 - Quantification of polychlorinated biphenyls in plastic granulates from the recycling of cables - Reference materials and interlaboratory comparison N2 - A procedure for the quantification of the PCB marker congeners 28, 52, 101, 138, 153, 180 in plastic waste form the recycling of cables in the range of content between 0.1 mg kg-1 and 20 mg kg-1 was validated. Representative reference materials for laboratory analyses were produced using granulates from different recycling processes. The method development included aspects of grinding, sieving, homogenising as well as the comparison of extraction methods and chromatographic conditions. The validated procedure foresees grinding of the technical sample to an upper particle size limit of 0.50 mm followed by extraction with an unpolar solvent such as n-hexane and gas chromatographic determination. LOD and LOQ for individual congeners ranged between 0.01 mg kg-1 and 0.08 mg kg-1. Electron capture detection (ECD) and mass selective detection (MS) were equivalent if chromatographic conditions were appropriately selected. The application of MS was advantageous in presence of significant amounts of interfering components which have been found in some cables. Three reference materials containing the marker congeners in the range of 0.1 mg kg-1–5 mg kg-1 were submitted to a final validation intercomparison with 23 selected field laboratories using the developed method. Relative reproducibility standard deviations varied between 15% and 33%. KW - PCB KW - Waste KW - Analysis KW - Method validation KW - Standardisation PY - 2006 U6 - https://doi.org/10.1016/j.chemosphere.2006.02.035 SN - 0045-6535 SN - 0366-7111 VL - 65 IS - 9 SP - 1652 EP - 1659 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-14050 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Becker, Roland A1 - Nehls, Irene T1 - Quantification of ethyl glucuronide in hair: effect of milling on extraction efficiency N2 - Aim: The objective of the study was to provide conclusive evidence for the effect of particle size reduction as by milling on the extractable content of ethyl glucuronide (EtG) of hair samples. Methods: A number of real case hair samples and two pooled hair materials with EtG contents in the range of 10–30 pg/mg were systematically compared with regard to the extraction yield of EtG after cutting to 2–3 mm length and pulverization with a ball mill. After the respective treatment the samples were submitted to aqueous extraction followed by quantification of EtG using HPLC-MS/MS. Results: It was unequivocally demonstrated that milling of hair samples prior to aqueous extraction significantly increases the extractable EtG content compared with cut hair. The effect ranged between 137 and 230% and was seen to occur regardless of the extent of pulverization. Cooling of samples was not necessary to prevent partial degradation of EtG during the grinding procedure. Conclusion: The options currently employed at choice in analytical practice (cutting or milling) were seen to significantly affect the extractable amount of EtG in hair. This is suspected to influence the degree of equivalence of quantification results obtained in different laboratories as well as their respective classification of a test subject's drinking behaviour on the basis of currently recommended cut-off values. PY - 2013 U6 - https://doi.org/10.1093/alcalc/agt059 SN - 0735-0414 SN - 0309-1635 SN - 1464-3502 VL - 48 IS - 5 SP - 558 EP - 563 PB - Univ. Press CY - Oxford AN - OPUS4-28843 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Theissen, H. A1 - Becker, Roland A1 - Hilbert, S. A1 - Nehls, Irene T1 - Probennahme und Quantifizierung von LHKW, Ethen und Methan in Grundwasser N2 - Der Einsatz aktiver (Pumpprobennahme, Schöpfprobennahme) und passiver (Diffusionsprobennahme) Probennahmetechniken zur Gehaltsbestimmung von LHKW sowie Ethen und Methan in Grundwasser wird aus ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit von Analysendaten untersucht. Am Beispiel einer Kontamination mit Trichlorethen sowie 1,2-Dichlorethen und Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit der passiven Probennahme durch unzureichende Strömungsverhältnisse im Aquifer sowie biologische Aktivität im Pegelrohr begrenzt ist. Der aktiven Probennahme ist bei ungeklärten oder unzureichenden Strömungsverhältnissen im Grundwasserleiter daher der Vorzug zu geben. Das gaschromatographische Verfahren für Vinylchlorid mittels Dampfraumtechnik wird um die Quantifizierung von Methan und Ethen erweitert. Dabei werden für die Bewertung von Altlasten relevante Bestimmungsgrenzen von 0,1 µg/l (Vinylchlorid, Ethen) sowie 5 µg/l (Methan) erreicht. Aus der Validierung der Analysenmethode und den Ergebnissen verschiedener Probennahmen werden Toleranzbereiche für die Ergebnisse eines Grundwassermonitorings abgeschätzt. Diese Streubreiten von Monitoring- Ergebnissen sollten von Ingenieurbüros und zuständigen Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse eines LHKW-Grundwasserschadens beachtet werden. KW - Passive sampling KW - Active sampling KW - Groundwater KW - Trichloroethene KW - Vinyl chloride KW - Methane PY - 2010 U6 - https://doi.org/10.1007/s00767-010-0144-7 SN - 1430-483X VL - 15 IS - 4 SP - 231 EP - 239 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-22617 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Becker, Roland A1 - Nehls, Irene T1 - Probenahme von LHKW in Grundwasser: Vergleich von aktiver und passiver Probenahme KW - Grundwasser KW - Probenahme KW - LHKW KW - Pumpprobe KW - Diffusionsprobe KW - PDB PY - 2009 SN - 1618-3258 SN - 1617-5301 VL - 15 IS - 4 SP - 85 EP - 87 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-20624 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharkoi, O. A1 - Becker, Roland A1 - Esslinger, Susanne A1 - Weber, M. A1 - Nehls, Irene T1 - Predicting sites of cytochrome P450-mediated hydroxylation applied to CYP3A4 and hexabromocyclododecane N2 - This article describes a simple and quick in silico method for the prediction of cytochrome P450 (CYP)-mediated hydroxylation of drug-like compounds. Testosterone and progesterone, two known substrates of CYP3A4, are used to test the method. Further, we apply the procedure to predict sites of hydroxylation of isomers of the flame retardant hexabromocyclododecane by CYP3A4. Within the method, the compound is rotated in the binding pocket of the cytochrome, so that each hydrogen under consideration is placed near the active centre. Afterwards, short molecular dynamics simulations are provided for each step of the rotation. All steps of the simulation are compared concerning the distances between the hydrogens and the active centre and the corresponding energies. The computational results correlate well with experimental results. KW - Predicting sites of metabolism KW - Cytochrome P450 KW - Hydroxylation KW - Metabolism of HBCD PY - 2015 U6 - https://doi.org/10.1080/08927022.2014.898845 SN - 0892-7022 SN - 1029-0435 VL - 41 IS - 7 SP - 538 EP - 546 PB - Gordon and Breach CY - New York, NY AN - OPUS4-30492 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharkoi, O. A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Weber, M. A1 - Nehls, Irene T1 - Phase I oxidation of alpha- and gamma-hexabromocyclododecane by cytochrome P450 enzymes: simulation of the steroisomerism of hydroxylated metabolites T2 - DIOXIN 2011 CY - Brussels, Belgium DA - 2011-08-21 KW - Bromierte Falmmschutzmittel KW - Hexabromcyclododecan KW - Cytochrom KW - Metaboliten KW - HPLC KW - Simulation PY - 2011 UR - http://www.dioxin20xx.org/pdfs/2011/1810.pdf SN - 1026-4892 VL - 73 SP - 730 EP - 733 AN - OPUS4-27263 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Walther, Wolfgang A1 - Becker, Roland A1 - Nehls, Irene A1 - Lehmann, Andreas A1 - Redlich, Christel A1 - Flemig, Sabine A1 - Dorgerloh, Ute A1 - Win, Tin A1 - Buge, Hans-Gerhard T1 - Pentchlorophenol (PCP) in Soil - Certified Reference Materials for Environmental Analysis T2 - Analytica Conference 2002 CY - Munich, Germany DA - 2002-04-23 PY - 2002 SP - 1(?) AN - OPUS4-1389 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nehls, Irene A1 - Becker, Roland A1 - Buge, Hans-Gerhard T1 - Pentachlorphenol - Eine Altlast im Holz PY - 2005 UR - http://archiv.aktuelle-wochenschau.de/2005/woche19/woche19.html IS - 19 SP - 1 EP - 2 PB - Gesellschaft Deutscher Chemiker CY - Frankfurt am Main AN - OPUS4-10845 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -