TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Nehls, Irene T1 - Stabilisation of groundwater samples for the quantification of organic trace pollutants JF - Environmental science : processes & impacts N2 - The concentration of contaminants in groundwater samples can be decreased by degradation in the time course between field sampling and quantification in the laboratory, especially in samples from sites where degradation activity is enhanced by remediation measures. The sampling sites covered a variety of priority organic pollutants such as volatile aromatic and chlorinated compounds, phenols and petroleum hydrocarbons and different remediation strategies such as anaerobic and aerobic microbial in situ degradation, in situ chemical oxidation, and on-site purification with biological treatment. The stability of the contaminants' concentration was investigated over a time range of several hours without cooling in the autosampler of the analytical equipment (short term) and over several days of storage until analysis (long term). A number of stabilisation techniques suggested in international standards ISO 5667-3:2013 and ASTM D6517:2000 were compared both with regard to short term and long term stabilisation of the contaminants and their practicability for field sampling campaigns. Long term storage turned out to be problematic for most compound groups even under cooling. Short term stability was problematic also for volatiles such as benzenic aromates, naphthalene and volatile organic halogenated compounds to be analysed by headspace gas chromatography. Acidification (pH <2) was sufficient to prevent degradation of benzenic aromates, naphthalene, phenols and petrol hydrocarbons for up to seven days. The use of acids was not applicable to stabilise volatiles in waters rich in carbonates and sulphides due to stripping of the volatiles with the liberated gases. The addition of sodium azide was successfully used for stabilisation of volatile organic halogenated compounds. KW - Groundwater KW - Sampling KW - Organic pollutants KW - Stabilisation KW - Analysis PY - 2013 DO - https://doi.org/10.1039/c3em00332a SN - 2050-7887 SN - 2050-7895 VL - 15 IS - 12 SP - 2329 EP - 2337 PB - RSC Publ. CY - CambridgeRSC Publ. AN - OPUS4-29689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Helmis, M. A1 - Mumme, J. A1 - Diakité, M. A1 - Nehls, Irene T1 - Hydrothermally carbonized plant materials: Patterns of volatile organic compounds detected by gas chromatography JF - Bioresource technology N2 - The nature and concentrations of volatile organic compounds (VOCs) in chars generated by hydrothermal carbonization (HTC) is of concern considering their application as soil amendment. Therefore, the presence of VOCs in solid HTC products obtained from wheat straw, biogas digestate and four woody materials was investigated using headspace gas chromatography. A variety of potentially harmful benzenic, phenolic and furanic volatiles along with various aldehydes and ketones were identified in feedstock- and temperature-specific patterns. The total amount of VOCs observed after equilibration between headspace and char samples produced at 270 °C ranged between 2000 and 16,000 µg/g (0.2–1.6 wt.%). Depending on feedstock 50–9000 µg/g of benzenes and 300–1800 µg/g of phenols were observed. Substances potentially harmful to soil ecology such as benzofurans (200–800 µg/g) and p-cymene (up to 6000 µg/g in pine wood char) exhibited concentrations that suggest restrained application of fresh hydrochar as soil amendment or for water purification. KW - Hydrochar KW - Mass spectrometry KW - Flame ionization detection KW - Phenols KW - Benzenes PY - 2013 DO - https://doi.org/10.1016/j.biortech.2012.12.102 SN - 0960-8524 SN - 1873-2976 VL - 130 SP - 621 EP - 628 PB - Elsevier Applied Science CY - Barking, Essex AN - OPUS4-27616 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. A1 - Nehls, Irene T1 - The quantification of hydrogen and methane in contaminated groundwater: validation of robust procedures for sampling and quantification JF - Journal of environmental monitoring N2 - A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM. PY - 2010 DO - https://doi.org/10.1039/c0em00091d SN - 1464-0325 SN - 1464-0333 VL - 12 IS - 10 SP - 1876 EP - 1884 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-22176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Determination of volatile organic sulfur compounds in contaminated groundwater JF - Environmental chemistry letters N2 - A practical method for the quantification of total purgeable organic sulfur (POS) in highly contaminated groundwater is described. Volatile organic sulfur compounds (VOSC) are purged from the water samples by a stream of oxygen and combusted. The emerging sulfur dioxide is absorbed in H2O2 and converted to sulfate which is quantified by ion chromatography and reported as mass sulfur equivalent. The overall limit of quantification is 0.03 mg l–1. The content of POS is balanced with the total VOSC determined by GC-AED after liquid–liquid extraction. Separate determination of the non-volatile organic sulfur compounds by direct combustion of the water sample and adsorption to charcoal yielded a mass balance of the total sulfur content. Semi-quantitative GC-MS after purge & trap accumulation revealed that the VOSC mixture is composed of C1–C4 alkyl sulfides. The implementation of the developed methodology for the quantification of VOSC as potential catalyst poison in a cleaning plant for groundwater contaminated with volatile haloorganics (VOX) is presented. KW - Contamination KW - Remediation KW - Summation parameter KW - Combustion KW - Ion chromatography KW - GC-AED KW - GC-MS PY - 2008 UR - http://www.springerlink.com/content/8612g42hwj7130g8/fulltext.pdf DO - https://doi.org/10.1007/s10311-007-0117-y SN - 1610-3653 SN - 1610-3661 VL - 6 IS - 2 SP - 101 EP - 106 PB - Springer CY - Berlin AN - OPUS4-16360 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Lutz, A. A1 - Bremser, Wolfram A1 - Hilbert, S. A1 - Nehls, Irene T1 - How to improve reliability in groundwater analysis: over a decade of experience with external quality control in field campaigns on volatile halogenated compounds JF - Journal of environmental monitoring N2 - The reliability in measurement results obtained during environmental monitoring is crucial for the assessment and further planning of remediation efforts on the respective contaminated sites by the responsible authorities. A case study concerned with groundwater contaminated with perchloroethylene, trichloroethylene and 1,1,2-trichlorotrifluoroethane including their degradation products which involves private contract laboratories and an independent provider of quality assurance (QA) is presented. The experience gained with biannual monitoring campaigns over 14 years indicates that the selection of contractors on basis of accreditation status and successful performance in interlaboratory comparisons are not sufficient. Rather the auditing of the contractors by the QA provider prior to each campaign and the crosschecking of selected monitoring samples by the QA provider led to a lasting improvement of reliability in the contractors' measurement results. A mean deviation of 20% from the reference value determined by the QA provider for the crosschecked samples was reached. KW - Groundwater monitoring KW - External quality management KW - QM KW - VOC PY - 2012 DO - https://doi.org/10.1039/c1em10460h SN - 1464-0325 SN - 1464-0333 VL - 14 IS - 1 SP - 217 EP - 223 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-25288 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppen, Robert A1 - Becker, Roland A1 - Esslinger, Susanne A1 - Nehls, Irene T1 - Enantiomer-specific analysis of hexabromocyclododecane in fish from Etnefjorden (Norway) JF - Chemosphere N2 - High-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) was applied to sterospecifically quantify the content of α-, β-, and γ-hexabromocyclododecane (HBCD) in six fish species from the Norwegian Etnefjorden. A combination of a β-PM cyclodextrin and an achiral column enabled the paired chromatographic separation of the stereoisomers in the order (-)-α-, (+)-α-, (-)-β-, (+)-β-, (+)-γ- and, (-)-γ-HBCD. The limits of detection were in the range of 6–21 pg g-1 depending on the stereoisomer and the concentrations of α-, β-, and γ-HBCD in fillets ranged from <5.4 ng g-1 to 11.1 µg g-1 lipid weight. α-HBCD enantiomers were throughout dominating, and in most cases the accumulation of the respective first eluted enantiomers ((-)-α-, (-)-β- and (+)-γ-HBCD) was observed. Deviations from the racemic EF-value were considered to be significant if it was outside of the expanded uncertainty range for each of the racemic HBCD-ratios. The composition of HBCD isomers varied between the investigated fish species and the relative high values for the γ-HBCD concentrations for the bottom-dwellers flounder and thorny skate seems to echo the HBCD pattern of ocean sediments. KW - Flame retardant KW - Diastereomers KW - Chiral separation KW - Bioaccumulation KW - Enantiomeric fraction PY - 2010 DO - https://doi.org/10.1016/j.chemosphere.2010.06.019 SN - 0045-6535 SN - 0366-7111 VL - 80 IS - 10 SP - 1241 EP - 1245 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-22377 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ammann, Dominic A1 - Becker, Roland A1 - Nehls, Irene T1 - Stability of ethyl glucuronide in hair reference materials after accelerated aging JF - Forensic science international N2 - Two different hair reference materials, one produced from authentic hair displaying an ethyl glucuronide (EtG) content of about 25 pg/mg and one obtained by fortification of blank hair to an EtG level of 85 pg/mg were submitted to accelerated aging between 4 degrees C and 60 degrees C for periods between one and 24 months. Subsequently, the EtG content was determined in the aged samples and untreated reference samples stored at -22 degrees C under repeatability conditions following the so-called isochronous approach. The EtG content remained stable even at 40 degrees C for 24 months and at 60 degrees C over six months. This is in contrast to many organic analytes contained in trace concentrations in diverse matrices. A slight but significant increase of the recovered EtG in case of authentic hair samples having been exposed for 24 months between 4 degrees C and 60 degrees C may be due to a temperature-driven process that allows increased recoveries of the physiologically embedded EtG. KW - Alcohol marker KW - Micropulverization KW - HPLC-MS/MS KW - Fortification KW - Long term stability PY - 2015 DO - https://doi.org/10.1016/j.forsciint.2015.09.015 SN - 0379-0738 SN - 1872-6283 VL - 257 SP - 337 EP - 340 PB - Elsevier Ireland Ldt. CY - Amsterdam [u.a.] AN - OPUS4-34940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Koch, Matthias A1 - Lehnik-Habrink, Petra A1 - Nehls, Irene T1 - Quantification of polychlorinated biphenyls in plastic granulates from the recycling of cables - Reference materials and interlaboratory comparison JF - Chemosphere N2 - A procedure for the quantification of the PCB marker congeners 28, 52, 101, 138, 153, 180 in plastic waste form the recycling of cables in the range of content between 0.1 mg kg-1 and 20 mg kg-1 was validated. Representative reference materials for laboratory analyses were produced using granulates from different recycling processes. The method development included aspects of grinding, sieving, homogenising as well as the comparison of extraction methods and chromatographic conditions. The validated procedure foresees grinding of the technical sample to an upper particle size limit of 0.50 mm followed by extraction with an unpolar solvent such as n-hexane and gas chromatographic determination. LOD and LOQ for individual congeners ranged between 0.01 mg kg-1 and 0.08 mg kg-1. Electron capture detection (ECD) and mass selective detection (MS) were equivalent if chromatographic conditions were appropriately selected. The application of MS was advantageous in presence of significant amounts of interfering components which have been found in some cables. Three reference materials containing the marker congeners in the range of 0.1 mg kg-1–5 mg kg-1 were submitted to a final validation intercomparison with 23 selected field laboratories using the developed method. Relative reproducibility standard deviations varied between 15% and 33%. KW - PCB KW - Waste KW - Analysis KW - Method validation KW - Standardisation PY - 2006 DO - https://doi.org/10.1016/j.chemosphere.2006.02.035 SN - 0045-6535 SN - 0366-7111 VL - 65 IS - 9 SP - 1652 EP - 1659 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-14050 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Gebert, Antje A1 - Emmerling, Franziska A1 - Becker, Roland A1 - Nehls, Irene T1 - Koenigs-Knorr reaction of fusel alcohols with methyl (1-bromo-2,3,4-tri-O-acetyl-alpha-D-glucopyranosid)uronate leading to the protected alkyl glucuronides-crystal structures and high resolution 1H and 13C NMR data JF - Carbohydrate research N2 - Crystal structures and high resolution 1H and 13C NMR spectral data for methyl (alkyl 2,3,4-tri-O-acetyl-β-D-glucopyranosid)uronates (alkyl = methyl, ethyl, n-propyl, i-propyl, n-butyl, sec-butyl, i-butyl, n-pentyl, 2-methyl-1-butyl and 3-methyl-1-butyl) are presented. KW - D-Glucuronic acid derivates KW - X-ray analysis KW - High resolution NMR KW - Anomeric configuration KW - Synthesis PY - 2012 DO - https://doi.org/10.1016/j.carres.2012.01.002 SN - 0008-6215 SN - 1873-426X VL - 352 SP - 186 EP - 190 PB - Elsevier CY - Amsterdam AN - OPUS4-25759 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bachmann, H. J. A1 - Bucheli, T. D. A1 - Dieguez-Alonso, A. A1 - Fabbri, D. A1 - Knicker, H. A1 - Schmidt, H.-P. A1 - Ulbricht, A. A1 - Becker, Roland A1 - Buscaroli, A. A1 - Buerge, D. A1 - Cross, A. A1 - Dickinson, D. A1 - Enders, A. A1 - Esteves, V.I. A1 - Evangelou, M. W. H. A1 - Fellet, G. A1 - Friedrich, K. A1 - Gasco Guerrero, G. A1 - Glaser, B. A1 - Hanke, U. M. A1 - Hanley, K. A1 - Hilber, I. A1 - Kalderis, D. A1 - Leifeld, J. A1 - Masek, O. A1 - Mumme, J. A1 - Paneque Carmona, M. A1 - Calvelo Pereira, R. A1 - Rees, F. A1 - Rombola, A. G. A1 - de la Rosa, J. M. A1 - Sakrabani, R. A1 - Sohi, S. A1 - Soja, G. A1 - Valagussa, M. A1 - Verheijen, F. A1 - Zehetner, F. T1 - Towards the standardization of biochar analysis: the COST action TD1107 interlaboratory comparison JF - Journal of agricultural and food chemistry N2 - Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical–chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future. KW - Biochar KW - Analysis KW - Standardization KW - Ring test KW - Interlaboratory comparison PY - 2016 DO - https://doi.org/10.1021/acs.jafc.5b05055 SN - 0021-8561 SN - 1520-5118 VL - 64 IS - 2 SP - 513 EP - 527 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-35289 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppen, Robert A1 - Becker, Roland A1 - Jung, Christian A1 - Nehls, Irene T1 - On the thermally induced isomerisation of hexabromocyclododecane stereoisomers JF - Chemosphere N2 - The interconversion of the stereoisomers contained in technical 1,2,5,6,9,10-hexabromocyclododecane, a major brominated flame retardant increasingly found in the environment and in biota, was investigated at elevated temperatures. The application of pure enantiomers of the three constituents α-, β-, and γ-HBCD enabled the unambiguous elucidation of the individual isomerisation reactions as well as the quantification of all respective rate constants. At 160 °C the rate constants range over two orders of magnitude from 1.50 × 10-3 to 1.88 × 10-5 mol(%) s-1. A preliminary mechanistic explanation for the differences of the rate constants which govern the composition of HBCD diastereomers at equilibrium is given. KW - Flame retardant KW - Diastereomers KW - Enantiomers KW - Rearrangement KW - Kinetics KW - HBCD PY - 2008 DO - https://doi.org/10.1016/j.chemosphere.2007.11.009 SN - 0045-6535 SN - 0366-7111 VL - 71 IS - 4 SP - 656 EP - 662 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-17753 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland T1 - Non-invasive cancer detection using volatile biomarkers: Is urine superior to breath? JF - Medical Hypothesis N2 - In recent years numerous reports have highlighted the options of chemical breath analysis with regard to noninvasive cancer detection. Certain volatile organic compounds (VOC) supposedly present in higher amounts or in characteristic patterns have been suggested as potential biomarkers. However, so far no clinical application based on a specific set of compounds appears to exist. Numerous reports on the capability of sniffer dogs and sensor arrays or electronic noses to distinguish breath of cancer patients and healthy controls supports the concept of genuine cancer-related volatile profiles. However, the actual compounds responsible for the scent are completely unknown and there is no correlation with the potential biomarkers suggested on basis of chemical trace analysis. It is outlined that specific features connected with the VOC analysis in breath – namely small concentrations of volatiles, interfering background concentrations, considerable sampling effort and sample instability, impracticability regarding routine application - stand in the way of substantial progress. The underlying chemicalanalytical challenge can only be met considering the severe susceptibility of VOC determination to these adverse conditions. Therefore, the attention is drawn to the needs for appropriate quality assurance/quality control as the most important feature for the reliable quantification of volatiles present in trace concentration. Consequently, the advantages of urine as an alternative matrix for volatile biomarker search in the context of diagnosing lung and other cancers are outlined with specific focus on quality assurance and practicability in clinical chemistry. The headspace over urine samples as the VOC source allows adapting gas chromatographical procedures well-established in water analysis. Foremost, the selection of urine over breath as non-invasive matrix should provide considerably more resilience to adverse effects during sampling and analysis. The most important advantage of urine over breath is seen in the option to partition, dispense, mix, spike, store, and thus to dispatch taylor-made urine samples on demand for quality control measures. Although it is still open at this point if cancer diagnosis supported by non-invasively sampled VOC profiles will ultimately reach clinical application the advantages of urine over breath should significantly facilitate urgently required steps beyond the current proof-of-concept stage and towards standardisation. KW - VOC KW - Breath KW - Urine KW - Lung cancer KW - Volatile organic compounds PY - 2020 DO - https://doi.org/10.1016/j.mehy.2020.110060 VL - 143 SP - 110060 PB - Elsevier Ltd. AN - OPUS4-51066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Elert, Anna Maria A1 - Becker, Roland A1 - Dümichen, Erik A1 - Eisentraut, Paul A1 - Falkenhagen, Jana A1 - Sturm, Heinz A1 - Braun, Ulrike T1 - Comparison of different methods for MP detection: What can we learn from them, and why asking the right question before measurments matters? JF - Environmental Pollution N2 - In recent years, an increasing trend towards investigating and monitoring the contamination of the environment by microplastics (MP) (plastic pieces < 5 mm) has been observed worldwide. Nonetheless, a reliable methodology that would facilitate and automate the monitoring of MP is still lacking. With the goal of selecting practical and standardized methods, and considering the challenges in microplastics detection, we present here a critical evaluation of two vibrational spectroscopies, Raman and Fourier transform infrared (FTIR) spectroscopy, and two extraction methods: thermal extraction desorption gas chromatography mass spectrometry (TED-GC-MS) and liquid extraction with subsequent size exclusion chromatography (SEC) using a soil with known contents of PE, PP, PS and PET as reference material. The obtained results were compared in terms of measurement time, technique handling, detection limits and requirements for sample preparation. The results showed that in designing and selecting the right methodology, the scientific question that determines what needs to be understood is significant, and should be considered carefully prior to analysis. Depending on whether the object of interest is quantification of the MP particles in the sample, or merely a quick estimate of sample contamination with plastics, the appropriate method must be selected. To obtain overall information about MP in environmental samples, the combination of several parallel approaches should be considered. KW - Microplastics KW - FTIR imaging KW - Raman imaging KW - TED-GC-MS KW - SEC KW - Analysis and identification PY - 2017 DO - https://doi.org/10.1016/j.envpol.2017.08.074 SN - 0269-7491 SN - 1873-6424 VL - 231 IS - 2 SP - 1256 EP - 1264 PB - Elsevier AN - OPUS4-42157 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bremser, Wolfram A1 - Becker, Roland A1 - Kipphardt, Heinrich A1 - Lehnik-Habrink, Petra A1 - Panne, Ulrich A1 - Töpfer, Antje T1 - Stability testing in an integrated scheme JF - Accreditation and quality assurance N2 - ISO Guide 35 deals with RM stability issues and scrutinizes the evaluation of stability testing results under the assumption that either there is no trend at all (a rather rare situation), or any observed deterministic change is insignificant and thus can be neglected. However, market demands for reliable reference materials are obviously not limited to stable or at least seemingly stable materials. In many analytical applications, analytes and measurands under consideration are known, or at least suspected, to be unstable on time scales that may vary widely from measurand to measurand. The Federal Institute for Materials Research and Testing (BAM) has developed (and successfully uses) an integrated approach in its certification practice. The approach is based on an initial stability study and subsequent post-certification monitoring. Data evaluation is model-based and takes advantage of all information collected in the stability testing scheme(s). It thus allows one to deal with any kind of instability observed, to assess limiting time intervals at any stress condition in the range tested, to estimate a final expiry date for materials with detected instabilities or the maximum admissible re-testing interval for seemingly stable materials, and to assess maximum admissible stress loads during delivery of the material to the customer. The article describes (and exemplifies) typical study layout, the model selection, and the integrated data assessment. KW - Certified reference materials KW - Stability KW - Shelf life KW - Arrhenius model KW - ERM PY - 2006 DO - https://doi.org/10.1007/s00769-006-0152-6 SN - 0949-1775 SN - 1432-0517 VL - 11 IS - 10 SP - 489 EP - 495 PB - Springer CY - Berlin AN - OPUS4-14063 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -