TY - JOUR A1 - Bartholmai, Matthias A1 - Kammermeier, Michael A1 - Koeppe, Tabea A1 - Werner, Klaus-Dieter ED - Nicoletto, G. ED - Pastrama, S.D. ED - Emri, I. T1 - High dynamic measurement of strain and acceleration using a multichannel measuring system with single cable serial connection N2 - Strain and acceleration measurement during high dynamic drop tests, e.g., of containments for dangerous goods is performed using high speed multichannel measuring systems. So far established and operated systems need a cable connection of every strain gauge and acceleration sensor with the measuring device, often counting up to a number of more than 100 cables, corresponding to the number of applied sensors. The result is a massive cable harness consisting of all single cables, which is difficult to handle and causes a number of practical problems. An innovative approach is proposed by using a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition. Promising results were presented in a previous study. This paper follows up with additional results from full-scale testing of a further enhanced single cable system for the application in drop tests. T2 - 32nd DANUBIA ADRIA SYMPOSIUM on Advances in Experimental Mechanics CY - Starý Smokovec, Slovakia DA - 22.09.2015 KW - Multichannel measuring KW - Single cable serial connection KW - Dangerous goods container KW - Drop test KW - High impact testing PY - 2016 U6 - https://doi.org/10.1016/j.matpr.2016.03.023 SN - 2214-7853 VL - 3 IS - 4 SP - 931 EP - 935 PB - Elsevier Ltd. AN - OPUS4-35689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bartholmai, Matthias A1 - Kammermeier, Michael A1 - Werner, Klaus-Dieter A1 - Homfeld, S.D. A1 - Köppe, Enrico T1 - Funkbasiertes Sensornetzwerk zur Schadensfrüherkennung an Bauwerken KW - Funksensorik KW - Sensornetzwerk KW - Schadensfrüherkennung KW - Strukturüberwachung PY - 2008 SN - 978-3-18-092011-5 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 2011 SP - 587 EP - 592 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-17264 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartholmai, Matthias A1 - Kammermeier, Michael A1 - Werner, Klaus-Dieter A1 - Köppe, Tabea T1 - Single cable, multichannel measuring system for heavy load, high impact drop tests N2 - Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were presented in a previous study. This paper follows up with results from laboratory and full-scale testing of an further enhanced single cable system for the application in drop tests.---------------------------------------------------------------------------------------------------------------------------------------------------------------- Vielkanalmesssysteme werden zur Messung von Dehnungen und Beschleunigungen bei Fallversuchen von Gefahrstoffbehältern eingesetzt. Konventionelle Systeme erfordern die Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. In einer vorangegangenen Studie wurden vielversprechende Ergebnisse durch Verwendung eines 1-Kabelmesssystems mit Datenbus und dezentraler Datenspeicherung erzielt. Dieser Artikel beinhaltet weiterführende Ergebnisse aus Labor- und Realversuchen mit einem weiterentwickelten System zur Anwendung bei Fallversuchen. KW - Multichannel measuring system KW - Single cable measuring KW - Dangerous goods container KW - Drop test KW - High Impact testing KW - Hopkinson bar KW - Vielkanalmesssystem KW - Gefahrstoffe KW - Behälter KW - Fallprüfung KW - Hochdynamische Prüfung KW - Hopkinsonstab PY - 2013 U6 - https://doi.org/10.1524/teme.2013.0033 SN - 0340-837X SN - 0178-2312 SN - 0171-8096 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. VL - 80 IS - 7-8 SP - 249 EP - 255 PB - Oldenbourg CY - München AN - OPUS4-28963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bartholmai, Matthias A1 - Köppe, Enrico A1 - Kammermeier, Michael A1 - Werner, Klaus-Dieter A1 - Homfeld, S.D. T1 - Funkbasiertes Sensornetzwerk zur Schadensfrüherkennung an Bauwerken T2 - Wireless Automation : funkgestützte Kommunikation in der industriellen Automatisierungstechnik ; Tagung Berlin CY - Berlin, Deutschland DA - 2008-02-28 KW - Funksensorik KW - Sensornetzwerk KW - Schadensfrüherkennung KW - Strukturüberwachung PY - 2008 SN - 978-3-18-092010-8 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte IS - 2010 SP - 117 EP - 125 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-17137 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Neumann, Patrick P. A1 - Werner, Klaus-Dieter A1 - Ebert, Sebastian A1 - Lazik, D. T1 - Linear sensor for areal subsurface gas monitoring - calibration routine and validation experiments N2 - Membrane based linear gas sensors and fiber optical sensors feature similar geometries and complement each other in quantities to be measured. To the author's best knowledge, it is the first time that these sensors are combined to a multifunctional sensor for distributed measuring of gas concentrations, temperature, and strain. Objective is a comprehensive monitoring of underground gas storage areas. In the presented project a 400 m² test site and a corresponding laboratory system were just built up to characterize, validate, and optimize the combined sensor. Application of the sensor lines in a grid structure should enable spatial resolution of the measurement data and early detection of relevant events, as gas leakage, temperature change, or mechanical impact. A Calibration routine was developed which can be applied subsequent to underground installation. First measurement results indicate the potential of the method, with regard to highly topical energy transport and storage issues. T2 - IEEE Sensors 2014 conference CY - Valencia, Spain DA - 02.11.2014 KW - Linear sensor KW - Distributed sensor KW - Monitoring of CO2 KW - Subsurface monitoring KW - Gas storage areas KW - Membrane-based gas sensing KW - Fibre optical sensing PY - 2014 SN - 978-1-4799-0161-6 U6 - https://doi.org/10.1109/ICSENS.2014.6985157 SP - 942 EP - 945 AN - OPUS4-32083 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Johann, Sergej A1 - Daum, Werner ED - Cosmi, F. T1 - Characterization of the temperature behavior of a piezoresistive accelerometer N2 - Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration. Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity. This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g. This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C. T2 - 34th Danubia-Adria Symposium on Advances in Experimental Mechanics CY - Trieste, Italy DA - 19.09.2017 KW - Accelerometer KW - Temperature behavior KW - Drop test PY - 2017 UR - https://www.openstarts.units.it/handle/10077/14921 SN - 978-88-8303-863-1 SP - 93 EP - 95 CY - Trieste AN - OPUS4-42109 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael T1 - Temperaturabhängige Prüfung von Beschleunigungsaufnehmern für stoßartige Beanspruchungen T2 - 15. ITG/GMA-Fachtagung - Sensoren und Messsysteme 2010 CY - Nürnberg, Deutschland DA - 2010-05-18 KW - Beschleunigungsaufnehmer KW - Hopkinsonstab KW - Fallprüfung KW - Gefahrstoffe KW - Behälter PY - 2010 SN - 978-3-8007-3260-9 IS - A1 / Paper 2 SP - 24 EP - 26 PB - VDE-Verl. CY - Berlin; Offenbach AN - OPUS4-21326 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael T1 - Hopkinson bar method for temperature dependent testing and calibration of accelerometers N2 - The measurement characteristics of every conventional accelerometer are temperature dependent - often to an extent which is highly relevant for the addressed application. For instance, at BAM Container drop tests are performed to investigate and evaluate the structural integrity of Containers for transport and storage of dangerous goods. Often, the test program includes drop tests at specific temperatures, also as part of approval procedures. The applied sensors are exposed to these test conditions and get influenced by them. Acceleration sensors show a considerable temperature influence on their fünction and characteristics. Particularly the damping mechanism of the seismic mass is a critical part. In regard to such applications, capable equipment and methods are required to consider and investigate this aspect in an adequate way. A fortiori as Manufacturer’s infonnation often is deficient. This study presents the setup and results of a method for testing and calibration of acceleration sensors under high dynamic irnpact. It combines a Hopkinson Bar with a temperature chamber. T2 - 31st Danubia-Adria Symposium on advances in experimental mechanics CY - Kempten, Germany DA - 24.09.2014 PY - 2014 SN - 978-3-00-046740-0 SP - 244 EP - 245 AN - OPUS4-31731 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael A1 - Köppe, Enrico T1 - Erprobung eines Messsystems mit Datenbus und dezentraler Datenspeicherung für den Einsatz bei Fallprüfungen N2 - Zur Untersuchung der Sicherheit von Behältern für den Transport und die Lagerung von Gefahrstoffen und -gütern werden Fallprüfungen durchgeführt. Die Aufpralldynamik und die strukturmechanischen Einwirkungen auf den Behälter werden mittels Beschleunigungsaufnehmern und Dehnungsmessstreifen erfasst. Dabei kommen derzeit Vielkanalmesssysteme zum Einsatz, die eine Verkabelung jeder einzelnen Messstelle und somit das Mitfallen eines Kabelbaums erfordern, wodurch Probleme bei der Versuchsvorbereitung und Durchführung entstehen. Die Verwendung eines Messsystems mit Datenbus und dezentraler Datenspeicherung bietet diesbezüglich einen vielversprechenden Lösungsansatz. KW - Vielkanalmesssystem KW - Datenbus KW - Gefahrstoffe KW - Behälter KW - Fallprüfung KW - Hopkinsonstab KW - Multichannel measuring system KW - Data bus KW - Dangerous goods KW - Container KW - Drop test KW - Hopkinson bar PY - 2009 U6 - https://doi.org/10.1524/teme.2009.0945 SN - 0340-837X SN - 0178-2312 SN - 0171-8096 VL - 76 IS - 10 SP - 447 EP - 454 PB - Oldenbourg CY - München AN - OPUS4-20284 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Werner, Klaus-Dieter A1 - Kammermeier, Michael A1 - Köppe, Tabea T1 - Multichannel measuring of strain and acceleration during high impact drop tests with a single cable system N2 - Multichannel measuring systems are used to measure strains and accelerations during drop tests of containments for dangerous goods. Conventional systems require cabling of each sensor and co-falling of the cable harness, causing problems in the test preparation and execution. Promising results of a single cable measuring system, consisting of measuring modules with data bus connection and local data acquisition were obtained in laboratory investigations and full-scale drop tests. T2 - Sensoren und Messsysteme 2014 - 17. ITG/GMA-Fachtagung CY - Nürnberg, Germany DA - 03.06.2014 KW - Multichannel measuring KW - Single cable system KW - Drop test PY - 2014 SN - 978-3-8007-3622-5 SN - 0932-6022 N1 - Geburtsname von Köppe, Tabea: Wilk, T. - Birth name of Köppe, Tabea: Wilk, T. N1 - Serientitel: ITG-Fachbericht – Series title: ITG-Fachbericht VL - 250 SP - Article 66, 1 EP - 5 PB - VDE Verlag GmbH AN - OPUS4-30859 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -