TY - CONF A1 - Johann, Sergej A1 - Mansurova, Maria A1 - Kohlhoff, Harald A1 - Gkertsos, Aris A1 - Neumann, Patrick P. A1 - Bell, Jérémy A1 - Bartholmai, Matthias T1 - Wireless Mobile Sensor Device for in-situ Measurements with Multiple Fluorescent Sensors N2 - This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniatur-ized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily imple-mented by adapting the optics and the software (database, data processing and calibration plots, etc.) T2 - IEEE Sensors 2018 CY - New Delhi, India DA - 28.10.2018 KW - Wireless mobile sensor device KW - Fluorescent sensor KW - Embedded system KW - Water quality KW - Oil PY - 2018 SN - 978-1-5386-4707-3 SP - 1067 EP - 1070 PB - IEEE CY - New Delhi, India AN - OPUS4-46556 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Tiebe, Carlo A1 - Bartholmai, Matthias A1 - Gawlitza, Kornelia T1 - Two tasks in environmental monitoring - calibration and characterization of gas sensors and remote sensing with multicopter platforms - Part 2 N2 - Emissions of ammonia into the environment are mainly caused by agriculture, but also by combustion processes in waste and by road traffic. Even at low concentrations, this substance is not only an odour nuisance, but also a substance with ecological and climatic relevance. Therefore, BAM tested commercial electrochemical, and metal oxide based sensors, which have limited suitability for measuring in the environmental molar fraction range. Alternatively, own developments for the detection of ammonia in the trace range were implemented, wherein the analyte is measured by changing the fluorescence of a BODIPY dye at 550 nm by means of a portable fluorescence sensor directly from the gas phase. For the calibration of ammonia sensors and measuring instruments, a stationary system based on the mixture of certified test gases from pressure cylinders with calibrated mass flow controllers is available. A test gas generator was developed for on-site calibration and testing of sensors and measuring devices. The generation of ammonia-containing gases in the environmental relevant range of levels below 1000 nmol/mol is carried out by the permeation method according to ISO 6145-10. For the traceability of ammonia, standards are provided and further developed by the National Metrological Institutes and designated institutes. Metrological standards are based on SI units and are a basis for traceability of sensors or gas analysers. T2 - Aarhus University, Department of Environmental Science, External seminar with Matthias Bartholmai and Carlo Tiebe CY - Roskilde, Denmark DA - 29.08.2018 KW - Environmental monitoring KW - Test gas generation KW - Fluorescence sensor KW - Ammonia PY - 2018 AN - OPUS4-45842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -