TY - JOUR A1 - Petrov, Sergej A1 - Neumann, Patrick P. A1 - Werner, Klaus-Dieter A1 - Wosniok, Aleksander A1 - Lazik, D. A1 - Bartholmai, Matthias ED - Nicoletto, G. ED - Pastrama, S.D. ED - Emri, I. T1 - Concept for investigating mechanical and thermal impacts on distributed subsurface gas monitoring N2 - A multifunctional sensor in line shape was developed and introduced in previous work for measuring of gas concentrations, temperature change, and strain. A current field study focuses on a spatially distributed monitoring of subsurface CO 2 gas storage sites in near real time. Mechanical impacts, e.g., caused by construction work, denudation, and seismic activity, can affect the integrity of underground gas storage sites. Thermal or moisture impacts, e.g., caused by weather conditions, can influence the gas Distribution behavior. In this paper, we briefly describe the setup of a CO 2 injection soil test field. This setup contains actuating elements for the investigation of mechanical and thermal impacts on distributed subsurface gas monitoring. A concept is given for evaluating these impacts and first experimental results are presented. T2 - 32nd DANUBIA ADRIA SYMPOSIUM on Advances in Experimental Mechanics CY - Starý Smokovec, Slovakia DA - 22.09.2015 KW - Linear sensor KW - Distributed sensor KW - Monitoring of CO 2 KW - Subsurface monitoring KW - Gas storage areas KW - Membrane-based gas sensing KW - Fibre optical sensing PY - 2016 U6 - https://doi.org/10.1016/j.matpr.2016.03.060 SN - 2214-7853 VL - 3 IS - 4 SP - 1124 EP - 1128 PB - Elsevier Ltd. AN - OPUS4-35688 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neumann, Patrick P. A1 - Werner, Klaus-Dieter A1 - Petrov, Sergej A1 - Bartholmai, Matthias A1 - Lazik, D. ED - Puente León, F. ED - Zagar, B. T1 - Aufbau eines großflächigen Testfeldes für verteilte Bodengassensorik und Untersuchung einer Monitoringmethode basierend auf Tomographie T1 - Setup of a large-scale test field for distributed soil gas sensors and testing of a monitoring method based on tomography N2 - A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues. N2 - Zur Validierung, Optimierung und praxisnahen Demonstration eines flächendeckenden Monitoringverfahrens für Untergrundgasspeichern wurde ein 400 m² großes Testfeld mit Gasinjektionssystem auf dem BAM Testgelände Technische Sicherheit aufgebaut. Die Methode kombiniert verteilte, linienförmige Gassensorik für die In-situ-Überwachung von Gasen im Boden mit den Mapping-Fähigkeiten der Computertomographie (CT). Auf Basis von orthogonal zueinander ausgerichteten linearen Gassensoren können mit diesem Verfahren so Zeitreihen der Gasverteilung rekonstruiert werden. Experimente mit Kohlendioxid (CO2) zeigen das Potential des Verfahrens zur schnellen Lokalisierung von Leckagen auf. KW - Soil test field KW - Distributed linear sensor KW - Membrane-based gas sensing KW - Subsurface monitoring KW - Gas storage areas KW - Computed tomography PY - 2016 U6 - https://doi.org/10.1515/teme-2016-0015 SN - 2196-7113 SN - 0171-8096 VL - 83 IS - 10 SP - 606 EP - 615 PB - Walter de Gruyter GmbH CY - Berlin, Deutschland AN - OPUS4-37653 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -