TY - CONF A1 - Neumann, Patrick P. A1 - Lazik, D. A1 - Bartholmai, Matthias T1 - Leak detection with linear soil gas sensors under field conditions - First experiences running a new measurement technique N2 - A 400 m² soil test field with gas injection system was built up, which enables an experimental validation of linear gas sensors for specific applications and gases in an application-relevant scale. Several injection and soil watering experiments with carbon dioxide (CO2) at different days with varying boundary conditions were performed indicating the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues. T2 - IEEE Sensors 2016 CY - Orlando, FL, USA DA - 30.10.2016 KW - Soil test field KW - Membrane-based linear gas sensor KW - Leak detection KW - Field conditions PY - 2016 SN - 978-1-4799-8287-5 SN - 1930-0395 SP - B-3-65, 757 EP - 759 PB - IEEE AN - OPUS4-38244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Neumann, Patrick P. A1 - Werner, Klaus-Dieter A1 - Petrov, Sergej A1 - Bartholmai, Matthias A1 - Lazik, D. ED - Puente León, F. ED - Zagar, B. T1 - Aufbau eines großflächigen Testfeldes für verteilte Bodengassensorik und Untersuchung einer Monitoringmethode basierend auf Tomographie T1 - Setup of a large-scale test field for distributed soil gas sensors and testing of a monitoring method based on tomography N2 - A 400 m² soil test field with gas injection system was built up for the purpose of large-scale validation, optimization, and characterization of a novel comprehensive monitoring method for underground gas storage areas. The method combines gas sensing technology with linear form factor for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct time-series of gas distribution maps based on samples of orthogonally-aligned linear gas sensors. Several injection experiments with carbon dioxide (CO2) at different days with varying boundary conditions indicates the potential of the method for, e.g., rapid leakage detection with respect to Carbon Capture and Storage (CCS) issues. N2 - Zur Validierung, Optimierung und praxisnahen Demonstration eines flächendeckenden Monitoringverfahrens für Untergrundgasspeichern wurde ein 400 m² großes Testfeld mit Gasinjektionssystem auf dem BAM Testgelände Technische Sicherheit aufgebaut. Die Methode kombiniert verteilte, linienförmige Gassensorik für die In-situ-Überwachung von Gasen im Boden mit den Mapping-Fähigkeiten der Computertomographie (CT). Auf Basis von orthogonal zueinander ausgerichteten linearen Gassensoren können mit diesem Verfahren so Zeitreihen der Gasverteilung rekonstruiert werden. Experimente mit Kohlendioxid (CO2) zeigen das Potential des Verfahrens zur schnellen Lokalisierung von Leckagen auf. KW - Soil test field KW - Distributed linear sensor KW - Membrane-based gas sensing KW - Subsurface monitoring KW - Gas storage areas KW - Computed tomography PY - 2016 U6 - https://doi.org/10.1515/teme-2016-0015 SN - 2196-7113 SN - 0171-8096 VL - 83 IS - 10 SP - 606 EP - 615 PB - Walter de Gruyter GmbH CY - Berlin, Deutschland AN - OPUS4-37653 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -