TY - CONF A1 - Lazik, D. A1 - Ebert, Sebastian A1 - Neumann, Patrick P. A1 - Bartholmai, Matthias T1 - Pipeline monitoring with linear gas sensors N2 - Comprehensive monitoring of pipelines over their full length is technically difficult and expensive. Considering a cost-benefit ratio it is reasonable to implement monitoring solutions in pipeline segments, which bear a high risk potential, like residential areas, construction sites, slopes, street or river crossings. Still such segments can measure up to several hundred meters in length, demanding for monitoring solutions that extend along such distances and enable fast response. Point wise sensing and periodical surveillance have clear drawbacks, particularly regarding early damage detection. Fibre optic sensors enable distributed sensing of temperature and strain, but they offer very limited possibilities for measuring gas concentrations. Linear membrane-based gas sensors enable the monitoring of gas concentrations alongside a pipeline. Such line-sensors are implemented in form of flexible tubes and can be arranged inside or outside the pipeline (also underwater or within the subsurface), corresponding to the technical requirements. The measuring method combines the gas specific diffusion rates through a membrane with Dalton’s law of partial pressures and enables the calculation of gas concentrations or the detection of a change of the gas composition. The objective is to detect gas leakages fast and with high reliability. Furthermore, the calibrated system enables to estimate the spatial extent of a leakage. So far the gas concentration measurement is tested for oxygen, carbon dioxide, methane; further gases should follow, e.g. hydrogen, carbon monoxide or mixtures like natural gas. The paper introduces in the different operating modes of line-sensors. A near real-time approach will be demonstrated to quantify the impact of a gas leak on the near environment. This approach is based on a critical length describing the expansion of the leaking gas. T2 - 9th Pipeline technology conference 2014 CY - Berlin, Germany DA - 12.05.2014 KW - Multi-sensor system KW - Condition monitoring KW - Safety management KW - Hazardous scenarios KW - Data fusion PY - 2014 SP - 1 EP - 9 AN - OPUS4-30727 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bartholmai, Matthias A1 - Ebert, Sebastian A1 - Neumann, Patrick P. A1 - Noske, Reinhard A1 - Rehak, W. A1 - Lazik, D. T1 - Linear gas sensor for methane based on a selectively permeable membrane N2 - In preliminary work, gas sensors in linear form based on the measuring principle of gas selective permeability through a membrane were developed and introduced for the detection and quantification of gas concentrations. In this study, first experimental results are presented for adapting the technology for measuring methane (CH4). A material with suitable selective permeability was identified and utilized in a sensor setup containing the gas selective membrane and a reference membrane, both integrated in a measuring cell, to which a gas stream with defined CH4 concentrations was applied. The results prove the sensor's capability for measuring methane and indicate further application potential of the method, e.g., as a robust field monitoring technology, since CH4 is the major component of natural gas, town gas, and fracking gas. T2 - AMA Conferences 2015 with SENSOR and IRS2 CY - Nuremberg, Germany DA - 19.05.2015 KW - Selective permeability KW - Quantification of gas concentrations KW - Spatially distributed monitoring KW - Gas storage sites KW - Methane measuring PY - 2015 SN - 978-3-9813484-8-4 U6 - https://doi.org/10.5162/sensor2015/P8.1 SP - 833 EP - 835 AN - OPUS4-33263 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -