TY - JOUR A1 - Fahmy, A. A1 - Anis, B. A1 - Szymoniak, Paulina A1 - Altmann, Korinna A1 - Schönhals, Andreas T1 - Graphene Oxide/Polyvinyl Alcohol–Formaldehyde Composite Loaded by Pb Ions: Structure and Electrochemical Performance N2 - An immobilization of graphene oxide (GO) into a matrix of polyvinyl formaldehyde (PVF) foam as an eco-friendly, low cost, superior, and easily recovered sorbent of Pb ions from an aqueous solution is described. The relationships between the structure and electrochemical properties of PVF/GO composite with implanted Pb ions are discussed for the first time. The number of alcohol groups decreased by 41% and 63% for PVF/GO and the PVF/GO/Pb composite, respectively, compared to pure PVF. This means that chemical bonds are formed between the Pb ions and the PVF/GO composite based on the OH groups. This bond formation causes an increase in the Tg values attributed to the formation of a strong surface complexation between adjacent layers of PVF/GO composite. The conductivity increases by about 2.8 orders of magnitude compared to the values of the PVF/GO/Pb composite compared to the PVF. This means the presence of Pb ions is the main factor for enhancing the conductivity where the conduction mechanism is changed from ionic for PVF to electronic conduction for PVF/GO and PVF/GO/Pb. KW - Graphene oxide KW - Polyvinyl formaldehyde KW - Lead ions KW - Conductivity PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549588 DO - https://doi.org/10.3390/polym14112303 SN - 2073-4360 VL - 14 IS - 11 SP - 1 EP - 16 PB - MDPI CY - Basel AN - OPUS4-54958 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Goedecke, Caroline A1 - Bannick, C.-G. A1 - Abusafia, A. A1 - Scheid, C. A1 - Steinmetz, H. A1 - Paul, Andrea A1 - Beleites, C. A1 - Braun, U. T1 - Identification of microplastic pathways within a typical European urban wastewater system N2 - In recent years, thermoextraction/desorption-gas chromatography/mass spectrometry (TED-GC/MS) has been developed as a rapid detection method for the determination of microplastics (MP) mass contents in numerous environmentally relevant matrices and, in particular, for the measurement of polymers in water samples without time-consuming sample preparation. The TED-GC/MS method was applied to investigate a typical European municipal wastewater system for possible MP masses. Such investigations are important in view of the recent revision of the Urban Wastewater Treatment Directive. Four different representative sampling sites were selected: greywater (domestic wastewater without toilet), combined sewer, and influent and effluent of a wastewater treatment plant (WWTP). All samples were collected by fractional filtration. Filtration was carried out over mesh sizes of 500, 100, 50, and in some cases, 5 µm. Polyethylene (PE), polypropylene (PP), and polystyrene (PS) were detected in all samples, with the PE fraction dominating in all cases. Styrene-butadiene rubber which serves as an indication of tire abrasion, was only found in the influent of the WWTP. The highest MP mass contents were found in the combined sewer, so MP can become a source of pollution during heavy rain events when the capacity limits of the effluent are reached, and the polluted effluent is released uncontrolled into the environment. Based on the studies, MP retention from the WWTP could be estimated to be approximately 96%. Few trends in polymer type or mass contents were detected within the different fractions of the samples or when comparing samples to each other. KW - Microplastics KW - Microplastic analysis KW - TED-GC/MS KW - Microplastic pathways KW - Mass contents PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568289 DO - https://doi.org/doi.org/10.1002/appl.202200078 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oksal-Kilinc, Sefine A1 - Altmann, Korinna A1 - Seiwert, Bettina A1 - Reemtsma, Thorsten A1 - Ruess, Liliane T1 - Grinding method and oxidative aging modulate the impact of tire wear microplastics on the reproduction of the nematode C. elegans N2 - Rationale Tire abrasion is one of the largest sources of microplastic in aquatic and terrestrial environments. Despite this fact, research on tire wear microplastic (TWP) and its effects on soil ecosystems is scarce, especially regarding natural weathering processes. This leaves a large knowledge gap on the interactions of TWP with soil biota. Methodology Cryo-milled tire tread (CMTT) and diamond-ground tire tread (DGTT) were artificially weathered through dry ozone treatment and heat exposure. Particles were analyzed via scanning electron microscopy, particle size distribution, and shape characterization. TWP leachate composition was examined using liquid chromatography–mass spectrometry. The impact on the reproduction of the nematode Caenorhabditis elegans, a widely used toxicological model, was tested for leachate concentration, exposure duration and TWP aging status, using offspring per adult as the endpoint. Results The comminution method significantly influenced TWP particle size distribution, with diamond grinding yielding smaller particles and a more structured surface morphology than cryo-milling. Aging with ozone (180 min) and heat (20 min at 100 °C) reduced DGTT particle sizes by 27-58%, but not in CMTT. Additionally, aging increased carboxylic functional groups and led to a brittle structure in both TWP types. Leachate composition varied with comminution method and aging. Benzothiazole, N-Cyclo-N-phenylurea, and aniline were more abundant in pristine and aged CMTT and aged DGTT. Diphenylguanidine had the highest concentration in all leachates. Aged TWP leachates, regardless of comminution, had significant toxic effects on C. elegans. Leachate from pristine CMTT was more toxic than from pristine DGTT. Nematode offspring correlated negatively with ozone exposure duration in aged DGTT. Tests with aged CMTT leachate showed even short-term exposure reduced offspring numbers. Discussion The results underscore the importance of oxidative and mechanical weathering in TWP toxicity and challenge the use of pristine particles in toxicological assays for risk assessment in the natural environment. KW - Microplastics KW - Tire abrasion KW - Environment PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654672 DO - https://doi.org/10.1071/EN25051 SN - 1448-2517 VL - 23 IS - 2 SP - 1 EP - 16 PB - CSIRO Publishing AN - OPUS4-65467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - THES A1 - Altmann, Korinna T1 - Abscheidung ultradünner funktionalgruppentragender Polymerschichten auf Metalloberflächen mittels Elektrospray Ionisation N2 - Funktionalisierte Oberflächen sind in vielen Bereichen, z. B. als Haftvermittler in Polymerkompositen, für katalytische Anwendungen oder als Sensoren von Interesse. Für viele solcher Anwendungen ist es ausreichend, den verwendeten Werkstoff mit einem ultradünnen Polymerfilm zu überziehen. Dazu gibt es bislang einige Verfahren, wie z. B. Chemical Vapour Deposition, Layer-by-Layer-Technik, Langmuir-Blodgett-Technik oder Spin-Coating, die alle bestimmte Nachteile haben. In der vorliegenden Arbeit wurden wenige Nanometer dicke Polymerschichten auf metallischen und nicht-metallischen Substraten mittels Elektrospray Ionisation abgeschieden. So wurden typischerweise etwa 10 nm dicke Schichten von Polyacrylsäure (PAA) hergestellt. Die analytische Charakterisierung der produzierten Schichten erfolgte mit der Röntgen-Photoelektronenspektroskopie. Die Atomkraft- bzw. Rasterelektronenmikroskopie gaben Auskunft über den Bedeckungsgrad und die Schichtmorphologie. Die Infrarot-Reflexions-Absorptions-Spektroskopie wurde zur Bestimmung des Restlösemittelgehaltes verwendet. Zur Optimierung der Schichtabscheidung und -struktur wurden verschiedene Parameter variiert, wie z. B. der Kapillaren-Proben-Abstand, die Beschichtungszeit oder die Beschichtungstemperatur, wobei sich herausstellte, dass die Schichtbildungsparameter für jedes Polymer individuell angepasst werden müssen. Es konnte gezeigt werden, dass Beschichtungen, bei denen sich das Substrat senkrecht zur Kapillare befindet, bei Raumtemperatur mit einem Kapillaren-Proben-Abstand von mindestens 100 mm zu lösemittelfreien PAA-Schichten führen. Dabei war die Ausbildung der Filmtopographie unabhängig sowohl von der Konzentration der Lösung als auch von der Oberflächenenergie des Substrates. N2 - Functionalized surfaces are of interest in plenty of technical fields, e.g. used as adhesion promoter for polymer composites, in catalytic applications or as sensors. For lots of these applications it is sufficient to cover the used materials with an ultra thin polymer film. All existing methods, e. g. chemical vapour pressure, layer-by-layer-technique, Langmuir-Blodgett technique or spin coating have disadvantages. The following work presents the deposition of few nanometer scale polymer layers on metallic and non-metal substrates by electrospray ionization. Most experiments were performed with poly(acrylic acid) (PAA). Layers of about 10 nm were deposited. The coverage and the morphology of the produced layers were analyzed by X-ray photoelectron spectroscopy, atomic force spectroscopy and scanning electron microscopy. The residual amount of solvent within the deposited layers was identified by infrared reflection absorption spectroscopy. Optimisation of the layer deposition was performed by varying the process parameters, e. g. distance to the sample, deposition time or deposition temperature. Based on the knowledge acquired in the experiments it was realized that the deposition parameters have to be found individually for each single polymer. It could be shown that depositions at room temperature with capillary-sample-distances higher than 100 mm, where the sample is placed vertical to the capillary, produce solvent free PAA layers. The film topography was independent of the concentration of the polymer solution and of the substrate surface energy. T3 - BAM Dissertationsreihe - 137 KW - Kapillaren-Proben-Abstand KW - Elektrospray Ionisation KW - Elektrospray Abscheidung KW - Ultradünne Schichtabscheidung KW - Polyacrylsäure KW - deposition KW - surface functionalization KW - electrospray ionisation PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-5142 VL - 137 SP - 1 EP - 132 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-514 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Ciornii, Dmitri A1 - Hodoroaba, Vasile-Dan A1 - Benismail, Nizar A1 - Altmann, Korinna T1 - Project 2: Interlaboratory Comparison on detection and quantitative assessment of microplastics by use of spectroscopic and thermo-analytical methods N2 - Validated and standardized methods in microplastic analysis are indispensable for robust monitoring and regulation. Alongside also reference materials are urgently needed. An interlaboratory comparison (ILC) offers a powerful tool to address both these challenges. The present study aimed to compare the precision and accuracy of various methods for the detection and quantification of microplastic in a water-soluble matrix. Additionally, it evaluated the suitability of the test materials (containing environmentally relevant plastic polymers) to serve as reference materials for the microplastic analysis. In this ILC several most used thermo-analytical and spectroscopic methods have been addressed: Pyrolysis-Gas Chromatography Mass Spectrometry (Py-GC/MS), Thermal Extraction-Desorption Gas Chromatography Mass Spectrometry (TED-GC/MS), micro-Fourier Transform Infrared Spectroscopy (µ-FTIR), and micro-Raman Spectroscopy and Laser Direct Infrared Spectroscopy (LDIR). Microplastic powders of polyethylene (PE) and polyethylene terephthalate (PET) were used to assess suitability of the test materials (microplastic tablets) for method validation and use in the ILCs. The participants were guided with a SOP how to dissolve the test samples and, depending on their selected method, either quantify the number of particles (by the spectroscopic methods) or determine the mass fraction of microplastic particles per sample (by the thermo-analytical methods). KW - ILC KW - Microplastic KW - FTIR KW - Raman KW - TED-GC/MS KW - Py-GC/MS PY - 2024 SP - 1 EP - 16 AN - OPUS4-60612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Freshwater compartments: Screening method for polymer identification and mass contents of microplastic particles using TED-GC-MS N2 - The pathways of plastics, especially of microplastic (MP), in environmental compartments, particularly in aquatic systems, are not well understood. The critical point is the lack of fast, harmonised methods for sampling, sample preparation and sample analysis. These three analytical steps are dependent on one another and must be optimised. In recent years, we developed a method for representative sampling and fast detection of MP in aqueous systems. The sampling in different freshwater bodies is performed in the field with a fractionated filtration system using mesh sizes of 500, 100 and 50 µm. For water with an intermediate or high content of suspended particular matter a minimum of 1000 L has to be filtered. In the lab, mesh sizes of 10 and 5 µm are used for further filtration. Subsequently, the water filtrates of the different particle size classes are sterilised, dried, weighed and homogenised, if necessary. Conventional methods for MP analysis are infrared and raman spectroscopy, giving information on the shapes and numbers of individually identified MP particles. Our focus is on the determination of mass contents of various polymers potentially contained in environmental samples. For qualitative and quantitative MP detection TED-GC-MS is used, a two-step method based on gas chromatography-mass spectrometry (GC-MS) with previous thermal extraction. This method not only enables us to screen the samples for characteristic marker-molecules, thus identifying single polymers, but furthermore allows the calculation of mass contents of individual polymers. In the present work, different freshwater compartments were exemplarily studied to identify containing polymers and calculate their mass content in MP particles. T2 - MICRO2018 CY - Lanzarote, Spain DA - 19.11.2018 KW - Microplastic KW - TED-GC-MS KW - Mass contents PY - 2018 AN - OPUS4-46739 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna A1 - Braun, U. T1 - Monitoring von Mikroplastik N2 - Der Vortrag gibt einen Überblick was bei der Analyse von Mikroplastik zu beachten ist und beschreibt die Vor- und Nachteile der TED-GC/MS. T2 - Abschlusstreffen MikroPlaTas CY - Online meeting DA - 23.06.2021 KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik PY - 2021 AN - OPUS4-52916 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Portela, Raquel A1 - Barbero, Francesco A1 - Breuninger, Esther A1 - Camassa, Laura Maria Azzurra A1 - Velickovic, Tanja Cirkovic A1 - Charitidis, Costas A1 - Costa, Anna A1 - Fadda, Marta A1 - Fengler, Petra A1 - Fenoglio, Ivana A1 - Giovannozzi, Andrea M. A1 - Haugen, Øyvind Pernell A1 - Kainourgios, Panagiotis A1 - von der Kammer, Frank A1 - Kirchner, Markus J. A1 - Lomax-Vogt, Madeleine A1 - Lujic, Tamara A1 - Milczewski, Frank A1 - Moussawi, Mhamad Aly A1 - Ortelli, Simona A1 - Parac-Vogt, Tatjana N. A1 - Potthoff, Annegret A1 - Reinosa, Julian J. A1 - Röschter, Sophie A1 - Sacco, Alessio A1 - Wimmer, Lukas A1 - Zanoni, Ilaria A1 - Dailey, Lea Ann T1 - Characterizing nanoplastic suspensions of increasing complexity: Inter-laboratory comparison of size measurements using dynamic light scattering N2 - Understanding the potential human health risks associated with micro- and nanoplastic exposure is currently a priority research area. Nanoplastic toxicity studies are complicated by the lack of available, well-characterized test and reference materials. Further, many nanoplastic test materials are inherently more polydisperse and heterogenous in shape compared to polystyrene beads, making accurate and representative size distribution measurements particularly challenging. The aim of this study was to conduct an inter-laboratory comparison of dynamic light scattering measurements, the most commonly used particle sizing method for nanomaterials. Using a published standard operating procedure, size measurements in water and a standardized cell culture medium (CCM) were generated for spherical, carboxy-functionalized polystyrene nanoparticles (PS-COOH; 50 nm; benchmark material), and for increasingly complex in-house produced spherical poly(ethylene terephthalate) (nanoPET) and irregular shaped polypropylene (nanoPP) test materials. The weighted mean of hydrodynamic diameters of PS-COOH dispersed in water (55 ± 5 nm) showed moderate variation between labs (coefficient of variation, CV = 8.2%) and were similar to literature reports. Measurements of nanoPET (82 ± 6 nm) and nanoPP (182 ± 12 nm) in water exhibited similar CV values (nanoPET: 7.3% and nanoPP; 6.8%). Dispersion of PS-COOH and nanoPET in CCM increased the CV to 15.1 and 14.2%, respectively, which is lower than literature reports (CV = 30%). We conclude with a series of practical recommendations for robust size measurements of nanoplastics in both water and complex media highlighting that strict adherence to a standard operating procedure is required to prevent particle agglomeration in CCM KW - Nanoplastics KW - Reference materials KW - Polypropylene PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-644571 DO - https://doi.org/10.1039/d5en00645g SN - 2051-8153 SP - 1 EP - 15 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-64457 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Alasonati, E A1 - Bartczak, D A1 - Altmann, Korinna A1 - Giovannozzi, A T1 - Towards Standardised Micro and Nanoplastics Analysis via Interlaboratory Comparisons: First Outlook of the VAMAS TWA 45 P3 Project N2 - This talk is part of the stakeholder workshop of the PlasticTrace project held in September 2025 in Oslo. The presentation shows first results of the VAMAS ILC on nanoplastics. PP nanoparticles were given to the participants. These were asked to measure the mass or particle number or size of the PP nanoplastics. Various techniques such as DLS, FFF, Py-GC/MS, TED-GC/MS, PTA were used. T2 - Stakeholder Workshop PlasticsTrace CY - Online meeting DA - 09.09.2025 KW - Nanoplastics KW - ILC KW - DLS KW - Polypropylene PY - 2025 AN - OPUS4-64714 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Wessen Problem ist Mikroplastik eigentlich? N2 - In den letzten 20 Jahren ist die Aufmerksamkeit vieler Forschender sowie der Politik und der Bürger selbst auf ein wachsendes Kunststoffproblem unserer Zeit stark gestiegen. Mangelnde Wertstoffkonzepte, Sammelstellen und unbedachtes Einbringen von Kunststoffprodukten in die Umwelt führen dort zu einer Anreicherung. Durch äußere Witterungseinflüsse können diese Produkte degradieren und fraktionieren, so dass heute in allen Teilen der Welt Mikroplastik (1-1000 µm, ISO/TR 21960:2020) unterschiedlicher Polymermaterialien nachgewiesen werden kann. Bei Mikroplastik gilt das Vorsorgeprinzip. Die Partikel können weiter zerfallen in Nanoplastik (< 1 µm, ISO/TR 21960:2020). Ob eine toxikologische Gefährdung von Mikro- oder Nanoplastik ausgeht, wird vielfältig untersucht. Bisher stehen valide Ergebnisse aus. Untersuchungen zur Häufigkeit, dem Transport und möglicher Senken und Eintragspfade muss aber Rechenschafft getragen werden, so dass ein Monitoring von Mikroplastik bereits in der Revision der Trinkwasserrahmen-Richtlinie und der Abwasserrahmen-Richtlinie gefordert wird. Bedenklich ist auch die Verordnung über Mindestanforderungen an die Wasserwiederverwendung (2020/741), in welcher nicht verbindlich gesagt wird, Wasser welcher Reinigungsstufe eines Klärwerks auf die Felder zur Wiederverwendung aufgebracht werden darf. Einer Regulierung über die EU-Plastikstrategie hinaus mit z.B. Verboten für Einwegplastik-Produkte und Rezyklingquoten kann nur entgegengewirkt werden, wenn valide Messmethoden, Referenzmaterialien und Standards existieren, die das tatsächliche Ausmaß von Mikroplastik-Konzentrationen in Luft, Wasser, Boden und Biota zuverlässig und genau aufzeigen. T2 - Technomer CY - Chemnitz, Germany DA - 06.11.2025 KW - Mikroplastik KW - Referenzmaterial KW - TED-GC/MS PY - 2025 AN - OPUS4-64618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Haugen, Øyvind P. A1 - Polanco-Garriz, Itziar A1 - Alcolea-Rodriguez, Victor A1 - Portela, Raquel A1 - Bæra, Rita A1 - Sadeghiankaffash, Hamed A1 - Hildebrandt, Jana A1 - Ciornii, Dmitri A1 - Altmann, Korinna A1 - Barbero, Francesco A1 - Fenoglio, Ivana A1 - Reinosa, Julián J. A1 - Fernández, José F. A1 - Katsumiti, Alberto A1 - Camassa, Laura M.A. A1 - Wallin, Håkan A1 - Zienolddiny-Narui, Shan A1 - Afanou, Anani K. T1 - Activation of Toll-like receptor 2 reveals microbial contamination beyond endotoxins on micro- and nanoplastics N2 - Current literature on health hazards associated with micro- and nanoplastics (MNPs) is largely influenced by studies that insufficiently account for potential microbial contamination of their test materials. This may lead to misinterpretation of outcomes, as the test materials may be incorrectly considered pristine MNPs. The present study screened eight MNP test materials for microbial contaminants using Toll-like receptor (TLR) reporter cells for TLR2 and TLR4 and the commonly used Limulus amebocyte lysate (LAL) assay. Our results show that MNPs testing negative for endotoxins, based on the absence of TLR4 activation and negative LAL results, may still contain microbial ligands that selectively activate TLR2. Moreover, five of the eight MNP test materials contained microbial ligands capable of activating TLR2 and/or TLR4. Compared to the LAL assay, TLR4-based screening effectively detected endotoxin contamination. Overall, we found that the TLR reporter cell assay provides broader coverage than the LAL assay in detecting microbial ligands, which appear to be highly prevalent in MNP test materials. KW - Nanoplastics KW - Microplastics KW - Microbial contamination PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653286 DO - https://doi.org/10.1016/j.tiv.2025.106190 SN - 0887-2333 VL - 112 SP - 1 EP - 8 PB - Elsevier Ltd. AN - OPUS4-65328 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Putzu, Mara A1 - Wiesner, Yosri A1 - Weimann, Christiane A1 - Hodoroaba, Vasile-Dan A1 - Muniategui Lorenzo, Soledad A1 - Fernández-Gonzáles, Verónica A1 - Booth, Andy M. A1 - Igartua, Amaia A1 - Benismail, Nizar A1 - Coïc, Laureen A1 - Chivas-Joly, Carine A1 - Fenoglio, Ivana A1 - Rossi, Andrea Mario A1 - Giovannozzi, Andrea Mario A1 - Altmann, Korinna T1 - Optimization of tablet processing as a reference material for microplastic detection methods N2 - Reference materials (RMs) are essential and highly demanded tools for the development and validation of methods for microplastic (MP) quantification in complex matrices, to ensure comparable and harmonized approaches aligned with EU commission criteria for monitoring MPs (e.g., Drinking Water Directive and Urban Wastewater Treatment Directive). This study investigates different approaches for optimizing the production of polypropylene (PP) RMs in the form of water-soluble tablets, which were carefully evaluated for their homogeneity and stability according to ISO Guide 30, ISO 33401, and ISO 33405. PP particles (1–100 μm) were produced by cryomilling and embedded in a lactose/PEG matrix, then pressed into tablets (18 µg theoretical PP mass). The production process was optimized by varying (i) the size distribution of the matrix components and (ii) the mixer instrument. The materials obtained were characterized by thermogravimetric analysis to assess the homogeneity distribution of MPs with respect to PP mass in the individual tablets and their stability over a 4-month period. The most promising approach, with a homogenous mass of 19 μg (standard deviation of 4 μg), relative standard deviation of 19%, was further investigated for homogeneity by comparison with thermo-analytical mass determination methods, such as TED-GC/MS (thermal extraction desorption-gas chromatography/mass spectrometry) and Py-GC/MS (pyrolysis-gas chromatography-mass spectrometry), and for number-based characterization using micro-Raman spectroscopy. Material characterization was also examined using laser diffraction, scanning electron microscopy, and ATR-FTIR. Based on the results, the optimized processing protocol yields a PP RM suitable for quality control and method performance studies supporting standardization. KW - Microplastics KW - TED-GC/MS KW - Reference materials KW - Polypropylene PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-653290 DO - https://doi.org/10.1007/s00216-025-06271-7 SN - 1618-2642 SP - 1 EP - 14 PB - Springer Science and Business Media LLC AN - OPUS4-65329 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Putzu, Mara A1 - Barbaresi, Marta A1 - Fadda, Marta A1 - Sacco, Alessio A1 - Piergiovanni, Maurizio A1 - Masino, Matteo A1 - Bianchi, Federica A1 - Altmann, Korinna A1 - Benismail, Nizar A1 - Coïc, Laureen A1 - Fenoglio, Ivana A1 - Mattarozzi, Monica A1 - Rossi, Andrea Mario A1 - Careri, Maria A1 - Giovannozzi, Andrea Mario T1 - Accuracy assessment of a micro-Raman spectroscopy method for small microplastic particles in infant milk formula N2 - The presence of microplastics (MPs) in the food chain is increasingly documented, raising concerns over potential risks to human health. Despite growing efforts, standardized methods for MPs detection in food matrices remain limited. This study presents an interlaboratory comparison (ILC) aimed at assessing the accuracy and comparability of an analytical approach for the identification and quantification of small MPs (5–100 μm) in infant milk powder using μ-Raman spectroscopy and a representative polyethylene terephthalate (PET) reference material (RM). The RM, formulated as water-soluble tablets, was designed to replicate the morphology, size distribution, and polymer composition of environmentally relevant MPs, and was previously assessed for homogeneity and stability for mass fraction and particle numbers. The approach was assessed using two PET RM batches with different MPs particle numbers (high load batch: 1759 ± 141 MPs; low load batch: 160 ± 22 MPs), subjected to an enzymatic–chemical digestion, followed by μ-Raman analysis performed independently in two laboratories with different instruments and operators. Results are reported as absolute particle counts per analyzed sample and demonstrated excellent recovery across all size classes, including the smallest particles (down to 5 μm), with recovery rates ranging from 82 % to 88 %, in good agreement with the RM reference values. The analytical approach proved to be robust, reproducible, and suitable for low-level MPs quantification in complex food matrices, supporting ongoing efforts toward method harmonization and standardization for reliable MPs monitoring in the food sector. KW - Microplastics KW - Milk KW - Raman microspectroscopy PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646239 DO - https://doi.org/10.1016/j.talo.2025.100586 SN - 2666-8319 VL - 12 SP - 1 EP - 8 PB - Elsevier B.V. AN - OPUS4-64623 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Eisentraut, Paul A1 - Altmann, Korinna T1 - One Year Observation of Microplastic Concentrations in the River Rhine N2 - In recent years, the quantification of microplastics (MP) in aquatic environments has gained increasing attention, particularly regarding their environmental distribution and potential exposure levels. Environmentally relevant exposure data are still essential for a realistic risk assessment of the harmful health potential of microplastics in freshwater systems. This study addresses a large data set of MP concentrations analyzed and processed under statistical aspects and provides mass concentrations as well as associated size fractions of the detected MP. Over a 12 month period, samples were collected at three locations and analyzed across three particle size fractions (100−500 μm, 50−100 μm, and 10−50 μm) using thermalextraction desorption-gas chromatography/mass spectrometry (TED-GC/MS). The most prevalent polymers identified were polyethylene (PE), polypropylene (PP), polystyrene (PS), styrene−butadiene rubber (SBR), and natural rubber (NR). Statistical analyses, including principal component and cluster analysis, revealed size-dependent patterns,minor seasonal variation and spatial variations. These findings are particularly significant for ecotoxicological research and regulatory development, especially regarding tire abrasion a rarely quantified but potentially harmful MP source. The study contributes aluable data for future environmental monitoring and supports EU directives on wastewater and drinking water quality KW - TED-GC/MS KW - Microplastics KW - Environment KW - Monitoring KW - Reference data PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654669 DO - https://doi.org/10.1021/acsestwater.5c00530 SN - 2690-0637 SP - 1 EP - 10 PB - American Chemical Society (ACS) AN - OPUS4-65466 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Dailey, L. A. A1 - Altmann, Korinna A1 - Ćirković Veličković, Tanja T1 - Exposition und Detektionstechniken: Der Weg zur Harmonisierung N2 - Der Vortrag gibt einen Überblick über Erkenntnisse der WG 1 und WG 3 des CUSP Clusters der Horizon Europe Projekte von Mikroplastik (2020-2025). Die Frage ist wie hoch ist die Exposition und ist das dann eine gesundheitliche Gefahr. Diskutiert werden Mechanismen, die helfen richtig und genau zu messen, z.B. Prozesskontrollen oder Referenzmaterialien. Es wird ein Weg zu mehr Harmonisierung im Bereich der Mikroplastik-Analytik aufgezeigt. T2 - Mikroplastik – Was wissen wir heute? BfR-Forum Verbraucherschutz CY - Berlin, Germany DA - 02.12.2025 KW - Microplastics KW - Reference materials KW - Harmonisation PY - 2025 AN - OPUS4-65330 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Textile Fibers as Reference Materials for Microplastic Release N2 - Fibers of textile origin are named as high contributor for microplastic pollution in the environment next to e.g. plastics from packaging, tire wear and paints. Small fibers and fragments (microplastics: 1-1000 µm) can be released from textiles by mechanical abrasion during application (e.g. wearing) or washing. To date, the occurrence, transport pathways, and impacts of such small fibers on the environment and human health remain unclear. The European Commission revised the Urban Wastewater Treatment Directive (Directive (EU) 2024/3019) and made monitoring of microplastics mandatory in the next years. Additionally, standards for microplastic detection are developed in the ISO standardization body ISO/TC 147/SC 2 with the documents ISO/DIS 16094-2 and ISO/DIS 16094-3. Detection mainly occurs by thermoanalytical methods for mass or vibrational methods with microscopes for numbers. Such standards and regulatory efforts need validated methods, which themselves need reference materials for validation. Reference materials are well characterized materials that are produced for a specific purpose and are homogeneous and stable within one property of interest. The shape and the composition of the reference particles/fibers will affect the detection, hence it is important to validate the instruments with fibers, if this is the task for monitoring campaigns. This work describes the production of realistic fibers as reference material for microplastic analysis. The individual samples contain of a small number (< 1000) and mass (< 20 µm) of fibres. Homogeneity and stability control occurred by thermogravimetric analysis and µ-Raman. Further characteristics were determined for type, shape and size distribution. T2 - TEXTEH CY - Bucharest, Romania DA - 23.10.2025 KW - Microplastics KW - Reference materials KW - Microfibers KW - Microfiber release PY - 2025 AN - OPUS4-64620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Production of reference materials using a quality by design approach N2 - Accurate analysis of microplastics is based on validated methods and the use of standardized protocols. Therefore, reference materials are essential to determine recovery rates and optimise the existing workflows. The reference materials should mimic the reality in terms of particle properties and concentration and are intended for a special use. The Quality-by-Design approach helps to select the users need and defines a target product profile with mandatory and desired particle properties. We will address different reference material top-down production processes with their limits and challenges for production of materials varying in size ranges of micro- and nanoplastics. T2 - OECD Workshop on Nanoplastics CY - Paris, France DA - 12.11.2025 KW - Microplastics KW - Reference materials KW - Nanoplastics KW - Quality-by-Design PY - 2025 AN - OPUS4-64717 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Kittner, Maria A1 - Altmann, Korinna A1 - Hamann, Sven A1 - Weyer, Rüdiger A1 - Kalbe, Ute T1 - Bewertung der Freisetzung von Mikroplastik aus Sportböden auf Kunststoffbasis - Abschlussbericht N2 - Die Europäische Kommission hat 2023 ein Verbot zum bewussten Austrag von Mikroplastik (MP) in die Umwelt beschlossen, das auch für die Verwendung von synthetischen Gummi-Granulaten (v. a. EPDM) in Sportböden gilt. In Deutschland gibt es laut DFB ca. 5100 Kunstrasenplätze. In der EU beläuft sich die Anzahl laut ECHA auf 13,000 Kunstrasen- und 47,000 Bolzplätze, Tendenz steigend. Das Hauptziel des Projektes war es daher, eine Massenbilanz für die Freisetzung von MP zu erstellen, um so eine Schätzung des MP-Austrags pro Kunstrasenplatz und Jahr zu ermöglichen. Dafür werden die MP-Emissionen von drei Kunstrasenszenarien in verschiedenen Zuständen (ungealtert, künstlich gealtert und in Echtzeit gealtert) verglichen: die Vergangenheit (Kunstrasen: fossilbasiert, EPDM-Füllung), die Gegenwart (der in Europa am häufigsten installierte Rasen) und die Zukunft (Rasen mit recycelten Grasfasern, keine synthetische Füllung sondern z.B. Quarzsand oder Korkschrott). Dazu werden fabrikneue Kunststoffrasen und EPDM-Granulat unter Laborbedingungen beschleunigt gealtert, um die Freiland-Beanspruchung eines Kunststoffrasens in circa 15 Jahren abzubilden. Die Verwendung spezieller Mikrofiltertiegel in Lysimeter-Experimenten ermöglicht die Abschätzung der Partikelgrößen des emittierten MP, was eine Grundbedingung für die Bewertung einer potenziellen Gesundheitsgefährdung für Menschen ist. Ergänzend wurden weitere umweltrelevante Schadstoffausträge aus den Kunststoffrasen quantifiziert. KW - Mikroplastik KW - Kunststoffrasen KW - Schadstoffe KW - Bewitterung KW - Lysimeter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633114 DO - https://doi.org/10.26272/opus4-63311 N1 - Das Projekt wurde gefördert vom Bundesinstitut für Bau-, Stadt- und Raumforschung (BBSR) im Auftrag des Bundesministeriums für Wohnen, Stadtentwicklung und Bauwesen (BMWSB) aus Mitteln des Innovationsprogramms Zukunft Bau. Aktenzeichen: FKZ 10.08.18.7-22.02. Projektlaufzeit: 09.2022 bis 03.2025. SP - 1 EP - 75 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-63311 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorau, Kristof A1 - Rückamp, Daniel A1 - Weber, Christian A1 - Scheeder, Georg A1 - Reßing, Ronja A1 - Peth, Stephan A1 - Otto, Philipp A1 - Altmann, Korinna A1 - Fries, Elke A1 - Hoppe, Martin T1 - Characterization and spatial distribution of mesoplastics in an arable soil N2 - AbstractExtraction of plastic particles from soil is challenging and, thus, exceptionally little spatial information on plastic distribution at the field scale has been gathered. However, for environmental risk assessment, adequate sampling should complement coherent plastic profiling. In this study, we investigated the spatial distribution of mesoplastics (MePs; from 5 mm up to 130 mm) in arable soil (Haplic Cambisol) managed intensively by 12 years of compost application. Geo‐referenced samples (n = 128) and five different sampling designs (n = 45) of variable sampling volume (from 2 to 300 L) were collected at a three hectare study site in Northern Germany (0–30 cm soil depth). Soil properties such as pH and soil organic carbon (SOC) were measured to evaluate dispersion measures of these data. In total, we found 259 MePs with a predominance of transparent packaging foils made of polyethylene and coloured fibres of polypropylene. Average particle metrics were a projection area of 47 (3–400) mm2, a Feret diameter of 18.5 (5.4–130) mm and a mass of 1.89 (0.11–221) mg. Caution is advised when measuring the particle mass due to still strongly adhering soil material, especially for fibre bundles with 0.544 mg soil mg−1 particle. We recommend using a 0.1 mol L−1 tetrasodium pyrophosphate solution to purify MePs by removing attached soil before weighing for further environmental risk assessment. The MePs count with a median value of 0.50 (0–3.2) particles kg−1 and median mass of 2.26 (0–221) mg kg−1 featured the highest coefficient of variation (CV) with 103% and 187%, respectively. This is 10–20 times larger in comparison to the CV of SOC (9.2%) and even 50–93 times larger than CV of soil pH (2.2%). This leads to the need of larger sample numbers to delineate plastic metrics in comparison with soil properties to identify a reliable mean value of the field within a predefined allowable error. Mesoplastics in the soil were characterized by a pure nugget effect variogram (no spatial correlation), revealed no intrafield variability and the sample volume yielded inconclusive results. Sampling for plastics in soil should either (i) drastically increase the sample number for a single field or (ii) communicate transparently that the allowable error is by far enhanced in comparison with classical soil properties like pH and SOC. More systematic studies featuring geo‐spatial analysis of MePs and smaller‐sized plastics in soils are required to propose adequate sampling designs across multiple land uses and plastics fingerprints. A larger database would, thereupon, pave the way for best‐practice guides on how to treat ‘outliers’ and search for robust estimators for spatial mapping of plastics in soils. KW - Large microplastics KW - Microplastics PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-617772 DO - https://doi.org/10.1111/ejss.70016 VL - 75 IS - 6 SP - 1 EP - 16 PB - Wiley AN - OPUS4-61777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wimmer, L A1 - Hoang, M V N A1 - Schwarzinger, J A1 - Jovanovic, V A1 - Adelkovic, B A1 - Velickovic, T C A1 - Meisel, T C A1 - Waniek, T A1 - Weimann, Christiane A1 - Altmann, Korinna A1 - Dailey, L A T1 - A quality-by-design inspired approach to develop PET and PP nanoplastic test materials for use in in vitro and in vivo biological assays N2 - Micro- and nanoplastics have become environmental pollutants of concern, receiving increased attention from consumers, scientists, and policymakers. The lack of knowledge about possible impacts on wildlife and human health requires further research, for which well-characterized testmaterials are needed. A quality-bydesign (QbD) driven approachwas used to produce sterile, endotoxinmonitored nanoplastics of polyethylene terephthalate (PET) and polypropylene (PP) with a size fraction of >90% below 1 μm and high yield of >90%. Glycerol was used as a versatile and biocompatible liquid storage medium which requires no further exogenous dispersing agent andmaintained colloidal stability, sterility (0 CFU mL−1), and low endotoxin levels (<0.1 EU mL−1) for more than one year of storage at room temperature. Further, the glycerol vehicle showed no biological effect on the tested human bronchial cell line Calu-3 up to 0.8% (w/v). Given the concentration of 40 mg g−1 nanoplastics in the glycerol stock, this corresponds to a nanoplastic concentration of 320 μg mL−1. The surfactant-free nanoplastics are dispersible in bio-relevant media from the glycerol stock without changing size characteristics and are suitable for in vitro and in vivo research. KW - Microplastics KW - Reference materials KW - Nanoplastics KW - Polymer 3R KW - Glycerol PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-629934 DO - https://doi.org/10.1039/D4EN01186D SN - 2051-8161 VL - 12 IS - 5 SP - 2667 EP - 2686 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-62993 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Visileanu, Emilia A1 - Catalin Grosu, Marian A1 - Tiberiu Miclea, Paul A1 - Altmann, Korinna A1 - Brossell, Dirk T1 - Methods for the collection and characterization of airborne particles in the textile industry N2 - Airborne particulate matter is one of the main air pollutants. Their impact on mortality, and the occurrence of pulmonary and cardiovascular complications, have been the subject of numerous studies. Airborne particles are complex mixtures of organic and inorganic substances from different sources of particle emissions. Particulate Matter (PM) particles are classified according to their aerodynamic diameter expressed in µm and can vary from coarse (PM 10) to fine (less than PM 2.5). These diameter considerations are fundamental because they condition the penetration of particles into the bronchopulmonary system and the body. In recent years, there has been an interest in so-called “ultra-fine” particles, with a diameter of 0.1 µm (or 100 nm), or PM 0.1. They are nanoparticles and their impact on human health is not yet clear.With more than 1.5 million employees, textiles and clothing is a diverse sector that plays an important role in the European manufacturing industry, producing a turnover of €162 billion.An important component of the solid particles that generate air pollution in the textile industry is microplastics (MP) and nano plastics (NP), which also include microfibers (<5mm) and nanofibers (<100 nm), respectively. The particles released into the air during fiber and yarn processing range from 1 µg/m3 to 50 µg/m3.The paper presents the results of the determination of indoor and outdoor air concentration levels in textile companies, to identify the areas with the highest concentration level, by using an online recording system such as the Laser Aerosol Spectrometer MINI LAS model 11-E. The total concentration level TSP (µg/m3), the fractions PM 10(µg/m3), PM 2.5(µg/m3), PM1(µg/m3), as well as the total number of particles TC (1/l), were shown. It was noted that TSP is approximately at the same level both indoors and outdoors, but the fractions of PM10, PM2.5, and PM1 have much higher values indoors than outdoors with possible consequences on workers' health.The next step was the collection of fibers, namely micro and nano plastic particles from the vicinity of the workplaces of polyester, polyamide, and polypropylene fibers processing units in the textile industry in Romania, to obtain a sufficient quantity for laboratory analysis to determine the size and shape of the particles as well as their chemical composition. Two types of pumps were used, differentiated by their operating parameters: TECORA SKYPOST with airflow of 38 l/min and GILAIRPLUS with airflow 2l/min. Filters made of different materials with different diameters and pore sizes were used, namely: quartz filters (ø 47 mm, and ø 37 mm) on a TECORA SKYPOST type pump, polycarbonate nucleopore coated with a gold membrane (ø 25 mm) and silica filter (ø 9 mm) on GILAIRPLUS type pump.Using descriptive statistics, the calculation of correlation coefficients highlighted a strong correlation between the variables: "Collected mass/ Air concentration" and "Collected mass/ Air volume" for all diameters of the filters.The highest collected particle volume, determined by weighing the filters before and after collection, was obtained with the quartz filters (ø 47 mm) at an airflow of 38 l/min. The particles collected (polyester, polyamide, polypropylene) in the first stage were analyzed by SEM and thermogravimetric and it was found that the quartz filters absorbed the particles inside, with very few remaining on the surface. Thus no known methods can be used to perform analysis for particles collected on quartz filters. The number of particles on the filters was insufficient for analysis either because of the collection parameters used or because of the loss of particles during transport. As a result, in the next step, the use of 9 mm Si filters using the GILAIRPLUS pump at an airflow rate of 2l/min was chosen.To improve the transport conditions and avoid the loss of the particles and keep them on the surface of the filters, two methods were applied:- after weighing the filters were reintroduced into the collection pump holder;- a filtration system for airborne micro-nano plastics was designed and manufactured to selectively collect and transport PM10 and PM1 particles collected on SI filters.In both cases, SEM, Raman mapping, and GS-MS microscopy were used for analysis.Several times more PM10 than PM1 (74.5µg compared to 12.5 µg) was found. In all cases, both particles and fibers showed the same Raman fingerprint.The GS-MS analyses showed some contamination of the workspaces with particles other than the processed fibers. The presence of non-notifiable substances was also observed.The most viable filters are Si filters with a pore size of 10 microns to 1 micron and the use of the selected collection and transport filter system. In the following a filter system will be applied for collection on Au membrane-coated polycarbonate filters. T2 - 5th International Conference on Human Systems Engineering and Design: Future Trends and Applications (IHSED 2023) KW - Microplastics KW - Textiles PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-624442 DO - https://doi.org/10.54941/ahfe1004132 VL - 112 SP - 212 EP - 223 PB - AHFE International AN - OPUS4-62444 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Realitätsnahe Referenzmaterialien für die Mikroplastik-Analytik und Vergleichsuntersuchungen N2 - Zur Validierung und Harmonisierung von verschiedenen Methoden in der Mikroplastik-Analytik werden polymere Referenzmaterialien benötigt. In diesem Vortrag wird dargestellt, was bisher an der BAM zu Referenzmaterialien für die Mikroplastik-Analytik entwickelt wurde, wo es hingehen soll und ein Überblick über bisher gelaufene Vergleichsuntersuchungen gebracht. T2 - Kick-off Meeting "Mikroplastik in Lebensmitteln" CY - Online meeting DA - 03.12.2020 KW - Mikroplastik KW - Referenzmaterial KW - Vergleichsuntersuchungen KW - Ringversuche PY - 2020 AN - OPUS4-51743 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Weyrauch, Steffen A1 - Reemtsma, Thorsten A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Ruhl, Aki S. A1 - Jekel, Martin T1 - Settling Velocities of Tire and Road Wear Particles: Analyzing Finely Graded Density Fractions of Samples from a Road Simulator and a Highway Tunnel N2 - The terminal settling velocity is considered the most critical parameter determining the transport of tire and road wear particles (TRWP) in aquatic environments. Nonetheless, no respective empirical data has been reported so far. In this study, particle samples from a road simulator and a highway tunnel were investigated with a validated imaging method. Different density and size fractions of both samples were measured separately, acquiring sizes and settling velocities of more than 30,000 individual particles. In addition, tire marker polymers were analyzed for each fraction via thermal extraction desorption-gas chromatography/mass spectrometry. Finally, the acquired particle data was combined according to the fractions’ estimated tire contents in order to deduce detailed probability distributions of particle size and settling velocity for the actual TRWP from both samples. Weighted by TRWP-incorporated tire mass, median diameters of 54 and 44 μm as well as median settling velocities of 0.65 and 0.22 mm/s were found for TRWP from the road simulator and highway tunnel, respectively. This study thus provides the first ever empirical data on TRWP settling velocities in water, which can be highly valuable input for modeling the environmental transport of TRWP and for dimensioning TRWP retention systems. KW - Microplastics KW - TED-GC/MS KW - Sinking velocities KW - Transport PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635449 DO - https://doi.org/10.1021/acs.est.5c04165 SN - 0013-936X VL - 59 IS - 26 SP - 13434 EP - 13446 PB - American Chemical Society (ACS) AN - OPUS4-63544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Visileanu, Emilia A1 - Altmann, Korinna A1 - Stepa, Raluca A1 - Haiducu, Maria A1 - Miclea, Paul Tiberiu A1 - Vladu, Alina A1 - Dondea, Felicia A1 - Grosu, Marian Catalin A1 - Scarlat, Razvan T1 - Comparative Analysis of Airborne Particle Concentrations in Textile Industry Environments Throughout the Workday N2 - This paper addresses the growing concern surrounding microplastic pollution, particularly within the textile industry, and the associated potential health risks linked to the inhalation and ingestion of microplastic particles. Microplastics, defined as plastic particles smaller than five millimeters, are increasingly found not only in aquatic environments, but also in soils, air, and food. Although research on the health impacts of microplastics is still emerging, early studies indicate that these particles could contribute to health issues, including oxidative stress, inflammation, and cardiovascular diseases. Notably, individuals with higher concentrations of plastics in arterial plaques are more susceptible to heart attacks and strokes. In the textile industry, synthetic fibers such as polyester, nylon, and acrylic release microplastics into the air during production. The paper discusses a study conducted in a textile company that processes polyester yarns, where airborne microplastic concentrations were measured at various locations throughout the day. Particle sizes ranging from 0.3 nm to 10 nm were analyzed, revealing the presence of polyester polymers in the particulate matter. These findings underscore the widespread nature of microplastic pollution, particularly in industrial settings, and raise concerns about the health risks associated with prolonged exposure to airborne microplastics. While further research is necessary to fully understand the extent of these health impacts, preliminary data suggest a troubling link between microplastic inhalation and cardiovascular conditions. KW - Microplastics KW - Textiles KW - Airborne particles PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635269 DO - https://doi.org/10.3390/microplastics4020034 SN - 2673-8929 VL - 4 IS - 2 SP - 1 EP - 17 PB - MDPI AG AN - OPUS4-63526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Bednarz, Marius A1 - Braun, Ulrike A1 - Bannick, Claus Gerhard A1 - Ricking, Mathias A1 - Altmann, Korinna T1 - A promising approach to monitor microplastic masses in composts N2 - Inputs of plastic impurities into the environment via the application of fertilizers are regulated in Germany and the EU by means of ordinances. Robust and fast analytical methods are the basis of legal regulations. Currently, only macro- and large microplastic contents (>1 mm) are measured. Microplastics (1–1,000 µm), are not yet monitored. Thermal analytical methods are suitable for this purpose, which can determine the mass content and can also be operated fully automatically in routine mode. Thermal extraction desorption-gas chromatography/mass spectrometry (TED-GC/MS) allows the identification of polymers and the determination of mass contents in solid samples from natural environments. In accordance with the German or European Commission (EC) Fertiliser Ordinance, composting plants should be monitored for microplastic particles with this method in the future. In this context a compost plant was sampled. At the end of the rotting process, the compost was sieved and separated in a coarse (>1 mm) and a fine fraction (<1 mm). The fine fraction was processed using density separation comparing NaCl and NaI as possible salt alternative and screened for microplastic masses by TED-GC/MS with additional validation and quality assurance experiments. With TED-GC/MS total microplastics mass contents of 1.1–3.0 μg/mg in finished compost could be detected with polyethylene mainly. What differs much to the total mass of plastics in the coarse fraction with up to 60 μg/mg, which were visually searched, identified via ATR-FTIR and gravimetrically weighted. KW - Microplastics KW - TED-GC/MS KW - Compost KW - Monitoring KW - Soil PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-586688 DO - https://doi.org/10.3389/fenvc.2023.1281558 SN - 2673-4486 VL - 4 SP - 1 EP - 12 PB - Frontiers Media CY - Lausanne AN - OPUS4-58668 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dudziak, Mateusz A1 - Topolniak, Ievgeniia A1 - Silbernagl, Dorothee A1 - Altmann, Korinna A1 - Sturm, Heinz T1 - Long-time behavior of surface properties of microstructures fabricated by multiphoton lithography N2 - The multiphoton lithography (MPL) technique represents the future of 3D microprinting, enabling the production of complex microscale objects with high precision. Although the MPL fabrication parameters are widely evaluated and discussed, not much attention has been given to the microscopic properties of 3D objects with respect to their surface properties and time-dependent stability. These properties are of crucial importance when it comes to the safe and durable use of these structures in biomedical applications. In this work, we investigate the surface properties of the MPL-produced SZ2080 polymeric microstructures with regard to the physical aging processes during the post-production stage. The influence of aging on the polymeric microstructures was investigated by means of Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS). As a result, a time-dependent change in Young’s Modulus, plastic deformation, and adhesion and their correlation to the development in chemical composition of the surface of MPL-microstructures are evaluated. The results presented here are valuable for the application of MPL-fabricated 3D objects in general, but especially in medical technology as they give detailed information of the physical and chemical time-dependent dynamic behavior of MPL-printed surfaces and thus their suitability and performance in biological systems. KW - Multiphoton lithography KW - Additive manufacturing KW - Microfabrication KW - SZ2080 negative photo-resist KW - Young´s modulus KW - Aging KW - Surface properties KW - X-ray photoelectron spectroscopy KW - Atomic force microscopy KW - Force-distance-curve PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542166 DO - https://doi.org/10.3390/nano11123285 SN - 2079-4991 VL - 11 IS - 12 SP - 1 EP - 12 PB - MDPI CY - Basel AN - OPUS4-54216 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Axel A1 - Altmann, Korinna A1 - Kocher, B. A1 - Braun, U. T1 - Determination of tire wear markers in soil samples and their distribution in a roadside soil N2 - Tire wear (TW) constitutes a significant source of microplastic in terrestrial ecosystems. It is known that particles emitted by roads can have an effect up to 100 m into adjacent areas. Here, we apply for the first-time thermal extraction desorption gas chromatography-mass spectrometry (TED-GC/MS) to determine TW in soil samples by detection of thermal decomposition products of styrene-butadiene rubber (SBR), without additional enrichment. Additionally, zinc contents were determined as an elemental marker for TW. Mixed soil samples were taken along three transects along a German motorway in 0.3, 2.0, and 5.0 m distance from the road. Sampling depths were 0–2, 2–5, 5–10, and 10–20 cm. Four fine fractions, 1 000–500, 500–100, 100–50, and <50 μm, were analyzed. TW contents based on SBR ranged from 155 to 15 898 mg kg−1. TW contents based on zinc were between 413 and 44 812 mg kg−1. Comparison of individual values of SBR and zinc reveals SBR as a more specific marker. Results confirm that most TW ends up in the topsoil within a 2 m distance. The sampling strategy resulted in representative data for a larger area. Standard deviations of quadruple TED-GC/MS determination of SBR were <10% for all grain size fractions. TED-GC/MS is a suitable analytical tool for determining TW in soil samples without the use of toxic chemicals, enrichment, or special sample preparation. KW - Microplastic KW - TED-GC/MS KW - Tire wear PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-543344 DO - https://doi.org/10.1016/j.chemosphere.2022.133653 VL - 294 SP - 1 EP - 8 PB - Elsevier Ltd. AN - OPUS4-54334 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmann, D. A1 - Saal, L. A1 - Zietschmann, F. A1 - Mai, M. A1 - Altmann, Korinna A1 - Al-Sabbagh, Dominik A1 - Schuhmann, P. A1 - Ruhl, A. A1 - Jekel, M. A1 - Braun, U. T1 - Characterization of activated carbons for water treatment using TGA‑FTIR for analysis of oxygen‑containing functional groups N2 - Water treatment with activated carbon (AC) is an established method for the removal of organic micropollutants and natu ral organic matter. However, it is not yet possible to predict the removal of individual pollutants. An appropriate material characterization, matching adsorption processes in water, might be the missing piece in the puzzle. To this end, this study examined 25 diferent commercially available ACs to evaluate their material properties. Frequently reported analyses, including N2 adsorption/desorption, CHNS(O), point of zero charge (PZC) analysis, and X-ray photoelectron spectroscopy, were conducted on a selected subset of powdered ACs. Inorganic elements examined using X-ray fuorescence and X-ray difraction spectroscopy revealed that relative elemental contents were distinctive to the individual AC’s raw material and activation procedure. This study also is the frst to use thermogravimetric analysis (TGA) coupled to Fourier-transform infrared spectroscopy (FTIR) to conduct quantitative analyses of functional surface oxygen groups (SOGs: carboxylic acid, anhydride, lactone, phenol, carbonyl, and pyrone groups) on such a large number of ACs. The comparably economical TGA method was found to provide good surrogates for the PZC by pyrolytic mass loss up to 600 ◦C (ML600), for the oxygen content by ML1000 and for the carbon content by oxidation. Mass loss profles depict the AC’s chemistry like fngerprints. Furthermore, we found that SOG contents determined by TGA-FTIR covered a wide individual range and depended on the raw material and production process of the AC. TGA and TGA-FTIR might therefore be used to identify the suitability of a particular AC for a variety of target substances in diferent target waters. This can help practitioners to control AC use in waterworks or wastewater treatment plants. KW - Adsorbtion KW - Organic contaminants KW - Temperature-programmed desorption KW - Proximate analysis KW - Principal component analysis PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-555506 DO - https://doi.org/10.1007/s13201-022-01723-2 SN - 2190-5495 VL - 12 SP - 1 EP - 13 PB - Springer CY - Berlin AN - OPUS4-55550 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abusafia, A. A1 - Scheid, C. A1 - Meurer, Maren A1 - Altmann, Korinna A1 - Dittmer, U. A1 - Steinmetz, H. T1 - Microplastic sampling strategies in urban drainage systems for quantification of urban emissions based on transport pathways N2 - Tracking waterborne microplastic (MP) in urban areas is a challenging task because of the various sources and transport pathways involved. Since MP occurs in low concentrations in most wastewater and stormwater streams, large sample volumes need to be captured, prepared, and carefully analyzed. The recent research in urban areas focused mainly on MP emissions at wastewater treatment plants (WWTPs), as obvious entry points into receiving waters. However, important transport pathways under wet-weather conditions are yet not been investigated thoroughly. In addition, the lack of comprehensive and comparable sampling strategies complicated the attempts for a deeper understanding of occurrence and sources. The goal of this paper is to (i) introduce and describe sampling strategies for MP at different locations in a municipal catchment area under dry and wet-weather conditions, (ii) quantify MP emissions from the entire catchment and two other smaller ones within the bigger catchment, and (iii) compare the emissions under dry and wet-weather conditions. WWTP has a high removal rate of MP (>96%), with an estimated emission rate of 189 kg/a or 0.94 g/[population equivalents (PEQ · a)], and polyethylene (PE) as the most abundant MP. The specific dry-weather emissions at a subcatchment were ≈30 g/(PEQ · a) higher than in the influent of WWTP with 23 g/(PEQ · a). Specific wet-weather emissions from large sub-catchment with higher traffic and population densities were 1952 g/(ha · a) higher than the emissions from smaller catchment (796 g/[ha · a]) with less population and traffic. The results suggest that wet-weather transport pathways are likely responsible for 2–4 times more MP emissions into receiving waters compared to dry-weather ones due to tire abrasion entered from streets through gullies. However, more investigations of wet-weather MP need to be carried out considering additional catchment attributes and storm event characteristics. KW - Combined sewer system KW - Large volume samplers KW - Microplastic pollution KW - Separate sewer system KW - Stormwater retention tank PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-568271 DO - https://doi.org/10.1002/appl.202200056 SP - 1 EP - 12 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56827 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Goedecke, C. A1 - Eisentraut, Paul A1 - Altmann, Korinna A1 - Elert, Anna Maria A1 - Bannick, C. G. A1 - Ricking, M. A1 - Obermaier, N. A1 - Barthel, A.-K. A1 - Schmitt, T. A1 - Jekel, M. A1 - Braun, U. T1 - Development of a routine screening method for the microplastic mass content in a wastewater treatment plant effluent N2 - An investigation of microplastic (MP) occurrence in a municipal wastewater treatment plant (WWTP) effluent with tertiary treatment was carried out. Representative sample volumes of 1 m3 were taken by applying a fractionated filtration method (500, 100, and 50 µm mesh sizes). The detection of MP mass fractions by thermal extraction desorption–gas chromatography/mass spectrometry (TED-GC/MS) was achieved without the previously required additional sample pretreatment for the first time. Different types of quantification methods for the evaluation of TED-GC/MS data were tested, and their accuracy and feasibility have been proven for real samples. Polyethylene, polystyrene, and polypropylene were identified in effluent samples. The polymer mass content varied significantly between 5 and 50 mg m−3. A correlation between the MP load and the quantity of suspended matter in the WWTP effluents, particle size distribution, particle type, and operation day (i.e., weekday, season, and capacity) was not found. It can be concluded that a meaningful assessment of WWTPs requires a comprehensive sampling campaign with varying operation conditions. KW - Microplastic KW - Waste water treatment KW - Thermoanalytics PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-550862 DO - https://doi.org/10.3389/fenvc.2022.844633 SN - 2673-4486 VL - 3 SP - 1 EP - 10 PB - Frontiers Media CY - Lausanne AN - OPUS4-55086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, S. A1 - Horstmann, J. A1 - Altmann, Korinna A1 - Braun, U. A1 - Hagendorf, C. T1 - A reference methodology for microplastic particle size distribution analysis: Sampling, filtration, and detection by optical microscopy and image processing N2 - Microplastic (MP) contamination in natural water circulation is a concern for environmental issues and human health. Various types of polymer materials have been identified and were detected in MP analytic test procedures. Beyond MP polymer type, particle size and form play a major role in water analysis due to possible negative toxicologic effects on flora and fauna. However, the correct quantitative measurement of MP size distribution over several orders of magnitude is strongly influenced by sample preparation, filtration materials and processes, and microanalytical techniques, as well as data acquisition and analysis. In this paper, a reference methodology is presented aiming at an improved quantitative analysis of MP particles. An MP analysis workflow is demonstrated including all steps from reference materials to sample preparation, filtration handling, and MP particle size distribution analysis. Background-corrected particle size distributions (1–1000 µm) have been determined for defined polyethylene (PE) and polyethylene terephthalate (PET) reference samples. Microscopically measured particle numbers and errors have been cross-checked with the total initial mass. In particular, defined reference MP samples (PE, PET) are initially characterized and applied to filtration experiments. Optical microscopy imaging on full-area Si filters with subsequent image analysis algorithms is used for statistical particle size distribution analysis. To quantify the effects of handling and filtration, several blind tests with distilled water are carried out to determine the particle background for data evaluation. Particle size distributions of PE and PET reference samples are qualitatively and quantitatively reproduced with respect to symmetry, and maximum and cut-off diameter of the distribution. It is shown that especially MP particles with a radius of >50 µm can be detected and retrieved with high reliability. For particle sizes <50 µm, a significant interference with background contamination is observed. Data from blank samples allows a correction of background contaminations. Furthermore, for enhanced sampling statistics, the recovery of the initial amount of MP will be qualitatively shown. The results are intended as an initial benchmark for MP analytics quality. This quality is based on statistical MP particle distributions and covers the complete analytic workflow starting from sample preparation to filtration and detection. Microscopic particle analysis provides an important supplement for the evaluation of established spectroscopic methods such as Fourier-transform infrared spectroscopy or Raman spectroscopy. KW - Drinking water KW - Filtration KW - Microplastics detection KW - Quality control KW - Statistical particle distribution PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-567625 DO - https://doi.org/10.1002/appl.202200055 SN - 2702-4288 SP - 1 EP - 10 PB - Wiley-VCH CY - Weinheim AN - OPUS4-56762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dittmar, Stefan A1 - Ruhl, Aki S. A1 - Altmann, Korinna A1 - Jekel, Martin T1 - Settling Velocities of Small Microplastic Fragments and Fibers N2 - There is only sparse empirical data on the settling velocity of small, non-buoyant microplastics thus far, although it is an important parameter governing their vertical transport within aquatic environments. This study reports the settling velocities of 4031 exemplary microplastic particles. Focusing on the environmentally most prevalent particle shapes, irregular microplastic fragments of four different polymer types (9–289 µm) as well as five discrete length fractions (50–600 µm) of common nylon and polyester fibers were investigated, respectively. All settling experiments were carried out in quiescent water using a specialized optical imaging setup. The method has been previously validated in order to minimize disruptive factors, e.g. thermal convection or particle interactions, and thus enable the precise measurements of the velocities of individual microplastic particles (0.003–9.094 mm/s). Based on the obtained data, ten existing models for predicting a particle’s terminal settling velocity were assessed. It is concluded that models, which were specifically deduced from empirical data on larger microplastics, fail to provide accurate predictions for small microplastics. Instead, a different approach is highlighted as a viable option for computing settling velocities across the microplastics continuum in terms of size, density and shape. KW - Microplastics KW - Microplastic fibers KW - Settling velocity KW - Sinking velocity KW - Sedimentation PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597455 DO - https://doi.org/10.1021/acs.est.3c09602 SN - 0013-936X VL - 58 IS - 14 SP - 6359 EP - 6369 PB - American Chemical Society (ACS) AN - OPUS4-59745 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Hoffmann, Thomas A1 - Range, David A1 - Altmann, Korinna T1 - Microplastics in sediments of the river Rhine—A workflow for preparation and analysis of sediment samples from aquatic river systems for monitoring purposes N2 - AbstractMicroplastics (MP) can be detected in all environmental systems. Marine and terrestrial aquatic systems, especially the transported suspended solids, have often been the focus of scientific investigations in the past. Sediments of aquatic river systems, on the other hand, were often ignored due to the time‐consuming sample preparation and analysis procedures. Spectroscopic measurement methods counting particle numbers are hardly suitable as detection methods, because there are plenty of natural particles next to a small number of MP particles. Integral methods, such as thermoanalytical methods are determining the particle mass independently of the inorganic components.In this study, a workflow for sample preparation via density separation and subsequent analysis by thermal extraction desorption‐gas chromatography/mass spectrometry is presented, which leads to representative and homogeneous samples and allows fast and robust MP mass content measurements suitable for routine analysis. Polymers were identified and quantified in all samples. Polyethylene and styrene‐butadiene rubber are the dominant polymers, besides polypropylene and polystyrene. Overall, total polymer masses between 1.18 and 337.0 µg/g could be determined. Highest MP concentrations in riverbed sediment are found in sites characterized by low flow velocities in harbors and reservoirs, while MP concentrations in sandy/gravelly bed sediments with higher flow velocities are small. KW - Microplastics KW - Density separation KW - TED-GC/MS KW - NaI PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597335 DO - https://doi.org/10.1002/appl.202200125 VL - 3 IS - 2 SP - 1 EP - 10 PB - Wiley VHC-Verlag AN - OPUS4-59733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Altmann, Korinna A1 - Sommerfeld, Thomas A1 - Braun, Ulrike T1 - Quantification of microplastics in a freshwater suspended organic matter using different thermoanalytical methods – outcome of an interlaboratory comparison N2 - A sedimented freshwater suspended organic matter fortified with particles of polyethylene (PE), polypropylene (PP), polystyrene (PS), and polyethylene terephthalate (PET) was employed in an interlaboratory comparison of thermoanalytical methods for microplastics identification and quantification. Three laboratories performed pyrolysis gas chromatography-mass spectrometry (Py-GC-MS), three others provided results using thermal extraction desorption followed by gas chromatography coupled to mass spectrometry (TED-GC-MS). One participant performed thermogravimetry-infrared spectroscopy (TGA-FTIR) and two participants used thermogravimetry coupled to mass spectrometry (TGA-MS). Further participants used differential scanning microscopy (DSC), a procedure based on micro combustion calorimetry (MCC) and a procedure based on elemental analysis. Each participant employed a different combination of sample treatment, calibration and instrumental Settings for polymer identification and quantification. Though there is obviously room for improvements regarding the between-laboratory reproducibility and the harmonization of procedures it was seen that the participants Performing Py-GC-MS, TED-GC-MS, and TGA-FTIR were able to correctly identify all polymers and to report reasonable quantification results in the investigated concentration range (PE: 20.0 μg/mg, PP: 5.70 μg/mg; PS: 2.20 μg/mg, PET: 18.0 μg/mg). Although for the other methods limitations exists regarding the detection of specific polymers, they showed potential as alternative approaches for polymer quantification in solid environmental matrices. KW - Interlaboratory comparison KW - Microplastics KW - Suspended organic matter KW - Pyrolysis PY - 2020 DO - https://doi.org/10.1016/j.jaap.2020.104829 VL - 148 SP - 1 EP - 6 PB - Elsevier B.V. AN - OPUS4-50977 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Monikh, Fazel A. A1 - Materić, Dušan A1 - Valsami-Jones, Eugenia A1 - Grossart, Hans-Peter A1 - Altmann, Korinna A1 - Holzinger, Rupert A1 - Lynch, Iseult A1 - Stubenrauch, Jessica A1 - Peijnenburg, Willie T1 - Challenges in studying microplastics in human brain N2 - Human exposure to microplastics and nanoplastics (MNPs) is an emerging concern with potential implications for health. As awareness of this issue grows, it has prompted increasing scientific attention toward understanding if, and how, MNPs accumulate in human tissues. In a recent study, Nihart et al.1 used the analytical technique of pyrolysis gas chromatography–mass spectrometry (Py-GC–MS) to detect MNPs in human liver, kidney and brain, reporting the highest concentrations in the brain, with polyethylene as the predominant polymer. The study as reported appears to face methodological challenges, such as limited contamination controls and lack of validation steps, which May affect the reliability of the reported concentrations. In this Matters Arising, we highlight methodological limitations that have General relevance for advancing robust and reproducible MNP detection in human biomonitoring studies. KW - Microplastics KW - Nanoplastics KW - Py-GC-MS PY - 2025 DO - https://doi.org/10.1038/s41591-025-04045-3 SN - 1078-8956 VL - 31 IS - 12 SP - 1 EP - 3 PB - Springer Science and Business Media LLC AN - OPUS4-64698 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Seasonal microplastic concentrations along the rivers Rhine and Danube N2 - Over the last 20 years, many researchers, politicians and citizens have become increasingly aware of the growing plastic problem of our time. A lack of recycling concepts and plastic collection points as well as careless dumping lead to accumulation of plastic products in the environment. Natural weathering can cause these plastics to degrade and fractionate, meaning that microplastics (1 1,000 µm, ISO/TR 21960:2020) and nanoplastics (< 1 µm, ISO/TR 21960:2020) of various synthetic polymer materials can now be detected in all parts of the world. Whether microplastics or nanoplastics pose a toxicological hazard is being investigated in a variety of ways. Valid results are still pending. However, the EU precautionary principle applies to micro- and nanoplastics. Monitoring of microplastics is already required in the revision of the Drinking Water and Wastewater Framework Directive. Reliable monitoring of rivers can be carried out by sampling with sedimentation boxes and microplastic detection by using thermal extraction desorption gas chromatography/mass spectrometry (TED-GC/MS) in routine operation (Figure 1). The river Rhine was sampled for microplastic masses at three different sampling locations over a period of one year and in addition the Danube at randomized sampling locations The TED-GC/MS results showed that various synthetic polymers frequently produced in industry, such as polyethylene, polypropylene or polystyrene as well as the tire compound styrene-butadiene rubber were found. The work not only shows a possible workflow for monitoring concepts, but also provides information on environmentally relevant concentrations of microplastics and tire components in surface waters. This in turn is necessary for ecotoxicological studies. T2 - ESOPS CY - Berlin, Germany DA - 09.09.2024 KW - Microplastics KW - TED-GC/MS KW - Polymer 3R PY - 2024 AN - OPUS4-61016 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Béalu, Zoé A1 - Walther, Johanna A1 - Abusafia, Attaallah A1 - Altmann, Korinna A1 - Meurer, Maren A1 - Gretzschel, Oliver A1 - Schäfer, Michael A1 - Steinmetz, Heidrun T1 - Removal of Organic Micropollutants and Microplastics via Ozonation Followed by Granular Activated Carbon Filtration N2 - Discharge from Wastewater Treatment Plants (WWTPs) can result in the emission of organic micropollutants (OMPs) and microplastics (MPs) into the aquatic environment. To prevent this harmful release, a pilot plant consisting of an ozonation followed by a granular activated carbon (GAC) filter was operated at a WWTP in Germany, and its side-effects on the concentrations of nitrogen (N) and phosphorous (P) compounds were measured. Over 80% of OMPs and transformation products were removed during the operating time (around 6000 bed volumes) no matter the ozone dose (from around 0.1 to 0.5 mgO3/mgDOC), except for Diatrizoic acid, whose breakthrough appeared at 3500 BV. Formation of the oxidation by-product, NDMA, increased with higher ozone doses, but the concentration remained below 100 ng/L. Bromate was formed at a higher ozone dose (0.4 mgO3/mgDOC) but at a low concentration—below 10 µg/L. The MP particles detected in the inflow (PE, SBR, PP, and PS) were effectively eliminated to a high degree, with a removal rate of at least 92%. Carbon parameters (COD, DOC, and SAC254) were removed further by the pilot plant, but to different extents. As expected, nitrate was formed during ozonation, while nitrite’s concentration decreased. Further, nitrite decreased and nitrate increased within the GAC filter, while ammonium was eliminated by at least 90%. Total P concentration decreased after the pilot, but the concentration of PO4-P increased. KW - Microplastics KW - TED-GC/MS KW - Granular Activated Carbon Filtration KW - Removal of Organic Micropollutants KW - Wastewater treatment plant PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615209 DO - https://doi.org/10.3390/environments11110241 VL - 11 IS - 11 SP - 1 EP - 38 PB - MDPI AG AN - OPUS4-61520 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fadda, Marta A1 - Sacco, Alessio A1 - Altmann, Korinna A1 - Ciornii, Dmitri A1 - Milczewski, Frank A1 - Bañares, Miguel A. A1 - Portela, Raquel A1 - Giovannozzi, Andrea Mario A1 - Rossi, Andrea Mario T1 - Tracking nanoplastics in drinking water: a new frontier with the combination of dielectrophoresis and Raman spectroscopy N2 - Detection of micro- (MPs) and nanoplastics (NPs) in food and environmental matrices has been gaining relevance due to their potential toxicological effects on human health. While MPs have been detected in a wide range of complex matrices, suitable methods for the characterization and chemical identification of NPs are still lacking, primarily due to significant methodological challenges associated with their nano-specific physiochemical properties, including size distribution (1 nm – 1 µm), dynamic surface chemical changes, and carbon-based composition, which complicate their detection compared to engineered nanomaterials. To overcome the traditional limitations of spectroscopic techniques in terms of spatial resolution and sensitivity at the sub-micrometer level, a novel label-free methodology is presented for specifically identifying the chemical composition of NPs directly in suspension by combining Raman spectroscopy with dielectrophoresis (DEP). Using a custom-built device, small volumes of NPs are injected into a dielectrophoretic cell and locally trapped by DEP forces to fill the Raman confocal volume, facilitating their detection and identification, and providing high signal-to-noise ratio Raman spectra for more reliable analysis. This approach was successfully applied to both Milli-Q water and a commercial brand of drinking water, enabling the rapid identification of various types of NPs with different sizes and polymer compositions at concentrations as low as 20 µg/mL. These included certified reference polystyrene beads ranging from 800 to 60 nm in diameter, as well as polydisperse NPs, more representative of real samples in terms of size distribution and polymer type, such as polyethylene (450 nm), polypropylene (180 nm), and polyethylene terephthalate (100 nm). Moreover, the chemical fingerprint of each NPs was thoroughly investigated and compared with the corresponding bulk polymers, highlighting possible changes in the Raman bands due to surface oxidation or nanometer-scale effect. Therefore, this innovative method can be considered a valuable approach for addressing gaps in the detection and identification of NPs, as well as for monitoring their dynamic phisiochemical changes in real matrices. KW - Nanoplastics KW - Water contaminants KW - Raman microspectroscopy KW - Dielectrophoresis PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633658 DO - https://doi.org/10.1186/s43591-025-00131-y SN - 2662-4966 VL - 5 IS - 1 SP - 1 EP - 11 PB - Springer Science and Business Media LLC AN - OPUS4-63365 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kittner, Maria A1 - Bauer, Vanessa A1 - Altmann, Korinna A1 - Kraft, Oliver A1 - Nordmann, Thomas A1 - Kalbe, Ute T1 - Mikroplastik-Austrage aus Kunststoffrasenplatzen ins Grundwasser N2 - Sportplätze aus Kunststoffrasen haben sich im Breitensport etabliert, weshalb ihre Anzahl jährlich zunimmt. Dabei werden Umwelt- und Gesundheitsrisiken, insbesondere durch Mikroplastik-Austräge, kontrovers diskutiert. Um die ungenügende Datenlage zur Menge des Austrages an Mikroplastik zu verbessern, haben sich zwei individuelle Studien mit dieser Forschungsfrage mit Fokus auf den Boden-Grundwasser-Pfad befasst, deren Ergebnisse hier erstmalig gemeinsam vorgestellt werden. Die erste Studie simulierte unter Laborbedingungen Mikroplastik-Emissionen von drei Kunststoffrasen-Szenarien in unterschiedlichen Alterungszuständen und analysierte thermoanalytisch. Die zweite Studie untersuchte Grundwasser-Proben von zwei Realsportplätzen, die 1 m unter dem Grundwasserspiegel entnommen und spektroskopisch untersucht wurden. Dies ermöglicht erstmalig einen Vergleich von Mikroplastik-Austrägen über das Sickerwasser in verschiedenen Bodentiefen. Die Labor-Ergebnisse ergaben je nach Alterungszustand des Kunststoffrasenplatzes Mikroplastik-Emissionen zwischen < 0,1 μg/L und 26,8 μg/L in 30 cm Bodentiefe. Wohingegen in den Grundwasser-Proben der Realsportplätze ab 4 m Bodentiefe keine Kunststoffrasen-Partikel detektiert wurden. Dies deutet darauf hin, dass vermehrt Mikroplastik durch Alterung aus Kunststoffrasen entsteht und im Sickerwasser ausgetragen wird, aber der Boden Mikroplastik- Partikel ≥ 5 μm durch Filtrationseffekte zurückhält, sodass diese im Grundwasser nicht nachweisbar waren. KW - Kunststoffrasen, Alterung, Mikroplastik, Elution, Schadstoffe PY - 2025 DO - https://doi.org/10.37307/j.1868-7741.2025.04.05 SN - 1868-7741 VL - 30 IS - 4 SP - 156 EP - 161 PB - Erich Schmidt Verlag GmbH & Co. KG AN - OPUS4-65098 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Altmann, Korinna A1 - Portela, Raquel A1 - Barbero, Francesco A1 - Breuninger, Esther A1 - Camassa, Laura Maria Azzurra A1 - Cirkovic Velickovic, Tanja A1 - Charitidis, Costas A1 - Costa, Anna A1 - Fadda, Marta A1 - Fengler, Petra A1 - Fenoglio, Ivana A1 - Giovannozzi, Andrea M. A1 - Haugen, Øyvind Pernell A1 - Kainourgios, Panagiotis A1 - von der Kammer, Frank A1 - Kirchner, Markus J. A1 - Lomax-Vogt, Madeleine A1 - Lujic, Tamara A1 - Milczewski, Frank A1 - Moussawi, Mhamad Aly A1 - Ortelli, Simona A1 - Parac-Vogt, Tatjana N. A1 - Potthoff, Annegret A1 - Reinosa, Julian J. A1 - Röschter, Sophie A1 - Sacco, Alessio A1 - Wimmer, Lukas A1 - Zanoni, Ilaria A1 - Dailey, Lea Ann T1 - Correction: Characterizing nanoplastic suspensions of increasing complexity: Inter-laboratory comparison of size measurements using dynamic light scattering N2 - Correction for ‘Characterizing nanoplastic suspensions of increasing complexity: Inter-laboratory comparison of size measurements using dynamic light scattering’ by Korinna Altmann et al., Environ. Sci.: Nano, 2025, 12, 5242–5256, https://doi.org/10.1039/D5EN00645G. PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-656330 DO - https://doi.org/10.1039/d6en90001a SN - 2051-8153 VL - 13 IS - 2 SP - 1233 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-65633 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Welche Rolle spielen Textilien als Mikroplastik-Quelle im Abwasser? N2 - In diesem Vortrag wird die Rolle der Waschmaschine als Eintragspfad von Mikroplastik in das Abwasser diskutiert und eine experimentelle Annäherung an das Problem beschrieben. T2 - Wasserwirtschaftliches Kolloquium der TU Berlin CY - Berlin, Germany DA - 14.12.2023 KW - Mikroplastik KW - TED-GC/MS KW - Waschmaschine PY - 2023 AN - OPUS4-59278 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Systemverständnis und Untersuchungsstrategien von Kunststoffeinträgen in die Umwelt – Ergebnisse des RUSEKU-Forschungsprojektes N2 - Ziel des Vortrages ist die Vermittlung der Herausforderungen der Mikroplastik-Analytik sowie der Harmonisierung der Analytik und des Ergebnistransfers in die Normung. T2 - Jahresabschluss-Sitzung GA "Mensch und Umwelt" CY - Online meeting DA - 24.11.2021 KW - Mikroplastik KW - Mikroplastik-Analytik PY - 2021 AN - OPUS4-53830 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Update from ISO/TC 61/SC14/WG4 N2 - This talk is an update from ISO/TC 61/SC14/WG4. It describes the production of microplastic test material for the use in an interlaboratory comparison. IWe report the first results of an ILC on microplastic detection methods organized under the pre-stantdardisation plattform of VAMAS (www.vamas.org/twa45/) as Project 2 “Development of standardized methodologies for characterisation of microplastics with microscopy and spectroscopy methods”, within the Technical Working Area TWA 45 “Micro and Nano Plastics in the Environment”. The ILC has gathered 84 participants all over the world representing all continents. Reference materials were developed by BAM to test the main methods for MPs detection as addressed in ISO/TR 21960:2020: thermo-analytical methods (Py-GC/MS and TED-GC/MS) and vibrational methods (µ-IR and µ-Raman). As far as the mass fraction is concerned, accurate results with quite a good precision were achieved with the thermo-analytical methods. Number-based results are not adressed here. T2 - ISO/TC 147/SC 2/JWG CY - Online meeting DA - 03.06.2025 KW - Microplastics KW - ILC KW - Reference materials PY - 2025 AN - OPUS4-63340 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ciornii, Dmitri A1 - Hodoroaba, Vasile-Dan A1 - Wachtendorf, Volker A1 - Fengler, Petra A1 - Altmann, Korinna T1 - Interlaboratory Comparison Reveals State of the Art in Microplastic Detection and Quantification Methods N2 - In this study, we investigate the current accuracy of widely used microplastic (MP) detection methods through an interlaboratory comparison (ILC) involving ISO-approved techniques. The ILC was organized under the prestandardization platform of VAMAS (Versailles Project on Advanced Materials and Standards) and gathered a large number (84) of analytical laboratories across the globe. The aim of this ILC was (i) to test and to compare two thermo-analytical and three spectroscopical methods with respect to their suitability to identify and quantify microplastics in a water-soluble matrix and (ii) to test the suitability of the microplastic test materials to be used in ILCs. Two reference materials (RMs), polyethylene terephthalate (PET) and polyethylene (PE) as powders with rough size ranges between 10 and 200 μm, were used to press tablets for the ILC. The following parameters had to be assessed: polymer identity, mass fraction, particle number concentration, and particle size distribution. The reproducibility, SR, in thermo-analytical experiments ranged from 62%−117% (for PE) and 45.9%−62% (for PET). In spectroscopical experiments, the SR varied between 121% and 129% (for PE) and 64% and 70% (for PET). Tablet dissolution turned out to be a very challenging step and should be optimized. Based on the knowledge gained, development of guidance for improved tablet filtration is in progress. Further, in this study, we discuss the main sources of uncertainties that need to be considered and minimized for preparation of standardized protocols for future measurements with higher accuracy. KW - Microplastics KW - Interlaboratory comparison KW - PlasticsFatE KW - PET KW - PE KW - Reference materials KW - VAMAS KW - Thermo-analytical methods KW - Spectroscopical methods PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-630462 DO - https://doi.org/10.1021/acs.analchem.4c05403 SN - 1520-6882 VL - 97 SP - 8719 EP - 8728 PB - ACS Publications AN - OPUS4-63046 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bartczak, Dorota A1 - Sikora, Aneta A1 - Goenaga-Infante, Heidi A1 - Altmann, Korinna A1 - Drexel, Roland A1 - Meier, Florian A1 - Alasonati, Enrica A1 - Lelong, Marc A1 - Cado, Florence A1 - Chivas-Joly, Carine A1 - Fadda, Marta A1 - Sacco, Alessio A1 - Rossi, Andrea Mario A1 - Pröfrock, Daniel A1 - Wippermann, Dominik A1 - Barbero, Francesco A1 - Fenoglio, Ivana A1 - Booth, Andy M. A1 - Sørensen, Lisbet A1 - Igartua, Amaia A1 - Wouters, Charlotte A1 - Mast, Jan A1 - Barbaresi, Marta A1 - Rossi, Francesca A1 - Piergiovanni, Maurizio A1 - Mattarozzi, Monica A1 - Careri, Maria A1 - Caebergs, Thierry A1 - Piette, Anne-Sophie A1 - Parot, Jeremie A1 - Giovannozzi, Andrea Mario T1 - Multiparameter characterisation of a nano-polypropylene representative test material with fractionation, light scattering, high-resolution microscopy, spectroscopy, and spectrometry methods N2 - Reference and quality control materials with comparable physicochemical properties to nanoplastic contaminants present in environmental and food nanoplastics are currently lacking. Here we report a nanoplastic polypropylene material prepared using a top-down approach involving mechanical fragmentation of larger plastics. The material was found to be homogeneous and stable in suspension and has been characterised for average particle size, size distribution range, particle number concentration, polypropylene mass fraction and inorganic impurity Content using a wide range of analytical methods, including AF4, cFFF, PTA, (MA)DLS, MALS, SEM, AFM, TEM, STEM, EDS,Raman, ICP-MS and pyGC-MS. The material was found to have a broad size distribution, ranging from 50 nm to over 200 nm, with the average particle size value dependent on the technique used to determine it. Particle number concentration ranged from 1.7–2.4 × 1010 g−1 , according to PTA. Spectroscopy techniques confirmed that the material was polypropylene, with evidence of aging due to an increased level of oxidation. The measured mass fraction was found to depend on the marker used and ranged between 3 and 5 μg g−1 . Inorganic impurities such as Si, Al, Mg, K, Na, S, Fe, Cl and Ca were also identified at ng g−1 levels. Comparability and complementarity across the measurement methods and techniques is also discussed. KW - Polypropylene KW - Nanoplastics KW - Analytics KW - Reference material KW - Scattering methods PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-654680 DO - https://doi.org/10.1039/D5EN00917K SN - 2051-8153 SP - 1 EP - 15 PB - Royal Society of Chemistry (RSC) AN - OPUS4-65468 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kittner, Maria A1 - Coesfeld, Bianca A1 - Schlau, Sven A1 - Werischak, Thomas A1 - Altmann, Korinna A1 - Kalbe, Ute T1 - Simultaneous sampling for microplastics and environmental contaminants from artificial turf: development of a new integrated microplastics eluate lysimeter N2 - To get a better understanding of potentially harmful contaminant emissions from soils or materials into the environment, politics demand practical and holistic sampling concepts for environmental samples such as leachates containing polycyclic aromatic hydrocarbons (PAH) or heavy metals, and hazardous particulate matter like microplastics (MP). Of particular concern are MP emissions from artificial turf sports pitches. So far, there has been only very limited data on MP mass emissions from artificial turf potentially posing a risk to the groundwater and no sampling device that allowed simultaneous sampling for dissolved and particulate contaminants. In this study, a novel integrative microplastics eluate lysimeter was developed to determine contaminant emissions from three artificial turf systems at different ageing states (fabric-new, artificially aged, real-time aged). For the accelerated ageing, all environmental simulation parameters were based on Central German conditions and simulated outdoor stress during the turf service lifespan of 15 years. MP masses from eluates were analysed using thermal extraction desorption-gas chromatography/mass spectrometry, PAH concentrations using gas chromatography/mass spectrometry and heavy metals using inductively coupled plasma-optical emission spectroscopy. Results showed that no PAH or heavy metal concentrations from the seepage water were above German legal limits for alternative granular construction materials considering soil and groundwater protection. Furthermore, it was found that only minimal MP emissions were released from new turf systems into the seepage water (< 1 mg/m2). Ageing of the artificial turf increased MP formation, especially from rubber infill and grass fibres, which are then carried into the seepage water. The highest total MP emissions over a simulated turf lifespan of 15 years were detected in two real-time aged turf systems ranging from 136.4–252.5 mg/m2. Considerably less total MP emissions were detected in accelerated aged artificial turf systems, one of which contained a synthetic rubber infill (5.4–8.0 mg/m2) and one without rubber infill (0.2–5.3 mg/m2). In summary, it was demonstrated that the newly developed MEL generated reliable and reproducible data and has thus proven itself as an integrated, straightforward and automated sampling device for simultaneous monitoring of particulate and dissolved pollutant emissions from simple soil matrices. KW - Lysimeter KW - Microplastics KW - Artificial turf KW - Thermal extraction desorption-gas chromatography/mass spectrometry KW - TED-GC/MS KW - Polycyclic aromatic hydrocarbons KW - PAH KW - Heavy metals KW - Soil samples PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-645301 DO - https://doi.org/10.1186/s12302-025-01235-1 SN - 2190-4715 VL - 37 IS - 1 SP - 1 EP - 15 PB - Springer Open AN - OPUS4-64530 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Production of small micro- and nanoplastic reference materials supporting harmonization and standardization N2 - The MICROPLASTICdays at Ljubliana, Slowenia, were organized in cooperation with the PRIORITY cost action. The topic has been reference materials this time. The talk gives an idea of the preparation of reference materials in micro- and nanoplastic topic to support standardisation and regulation. It defines the term of micro-and nanoplastics and presents different case studies and critical attributes to the production depending on the enduser needs. T2 - MICROPLASTICdays CY - Ljubljana, Slovenia DA - 25.03.2025 KW - Microplastics KW - Nanoplastics KW - Reference materials PY - 2025 AN - OPUS4-62801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Altmann, Korinna T1 - Microplastic occurrence in urban sewage systems: Identification of sources for pathways into the environment N2 - All over the world, microplastic (MP) particles (particle size: 1 - 1.000 µm) are found in water, soil, air, biota and even food products. But plenty of these discussed findings are based on a very low number of real datasets, which are extrapolated to general projections. Furthermore, most data are not comparable because the strategies for sampling, sample preparation and detection methods are not harmonised/ or standardised. This would require extensive proficiancy tests. Because of the ubiquity presence and the unclear risks, which might arise from those particles, various political and environmental organisations (i.e. OECD, UNEP, WHO) identify the reduction of plastic entry in the environment as a key challenge for now and the future. This challenge includes the identification of relevant entry pathways but also the demand of harmonised, meaningful and reliable analytical procedures. Regarding this task within the last few years, a fast practical solution for MP analysis has been developed, which includes the steps of representative sampling, adequate sample preparation and fast detection. Sampling is done by fractional filtration over sieves with mesh sizes of 500, 100, 50 and 5 µm [1]. The received samples are measured by ThermoExtraction/Desorption-Gas Chromatography-Mass Spectrometry (TED-GC-MS) [1,2]. for the most abundant polymers used in practice, which are polyethylene (PE), polypropylene (PP), polystyrene (PS), polyethylene terephthalate (PET), polyamide (PA) and acrylate as well as styrene-butadiene-rubber (SBR), a main component of tires. The present presentation will give first-time insight in a comprehensive dataset of microplastic analysis for an exemplary urban sewage system. MP mass contents of different waters at several days, such as greywater, stormwater retention tank, influent and effluent of a wastewater treatment plant (WWTP) within an urban sewage system in Germany are determined. Furthermore, the mass of the polymers found in dry weather and rain weather flow are compared. The use of these large datasets allows first expressive conclusions regarding the contribution of urban sewage system to the MP entry sources in the environments. We found PP and PS in all different waters. Furthermore, there is SBR in influent and also in effluent of the WWTP. Surprisingly, we could also detect hugh amounts of PE in the effluent of the WWTP. T2 - SETAC Europe 2020 CY - Online meeting DA - 03.05.2020 KW - Microplastic analysis KW - TED-GC/MS KW - Microplastic particles KW - Microplastic mass contents PY - 2020 AN - OPUS4-50795 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Drago, C A1 - Wiesner, Yosri A1 - Braun, U A1 - Giovannozi, A A1 - Fadda, M A1 - Putzu, Mara A1 - Lorenzo, S A1 - Moscoso-Pérez, C A1 - Benismail, N A1 - Palma, C A1 - Almeida, J A1 - Mattarozzi, M A1 - Barbaresi, M A1 - Piergiovanni, M A1 - Masino, M A1 - Bianchi, F A1 - Careri, M A1 - v Bavel, B A1 - Maltseva, A A1 - Sillanpää, M A1 - Pröfrock, D A1 - Wippermann, D A1 - Altmann, Korinna T1 - Harmonisation of sample preparation for microplastic analysis: Recovery rates of tablets containing microplastics as reference material for food and environmental matrix N2 - Microplastic are found ubiquitarians in the environment and food products. Up to now, their impact of risks on health and environment is still controversially discussed, but based on the precautionary principle alone, their presence should be monitored and emission should be reduced (see here also the status of existing EU regulations ). The crucial point is not only the reduction of microplastics pollution but also the introduction of legally binding, standardized procedures for their analysis. The limited availability of certified reference material as well as absence of standard operating procedures to identify, characterize and quantify microplastics according to number and mass have generated lack of comparability between different analytical methods and laboratories; but also, the need of time-consuming development of own protocols for each laboratory. Further on, harmonisation and standardisation of microplastics analysis requires specific reference materials that are used to validate the measurement and to ensure the comparability of results. In the first step, we developed tablets of a water-soluble matrix, containing defined numbers of microplastic particles or mass contents. These can be solved in water and can be handled as reference materials in bottled drinking water without additional sample preparation. These samples can be measured, using mass-based methods as thermo-analytical methods like thermal desorption-gas chromatography-mass spectrometry (TED-GC/MS) or pyrolysis–gas chromatography–mass spectrometry (Py-GC/MS) and using umber-based methods as vibrational spectroscopy like Infrared and Raman directly after filtration. The aim of this work was to delevop standard operating procedure to measure microplastics in more complex matrices and to harmonise and compare different detection and characterization methods. In fact, these matrices require different additional treatments to allow a reliable quantification and identification of microplastics. T2 - SETAC Europe 2025 CY - Vienna, Austria DA - 11.05.2025 KW - Microplastics KW - Nanoplastics PY - 2025 AN - OPUS4-63366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiesner, Yosri A1 - Altmann, Korinna A1 - Braun, U. T1 - Determination of Microplastic Mass Content by Thermal Extraction Desorption Gas Chromatography– Mass Spectrometry N2 - The scientific and practical challenge of detecting microplastics (MPs) in the environment in a targeted and rapid manner is solved by innovative coupling of thermogravimetric analysis with mass spectrometric methods. Fast identification and quantitative determination of most thermoplastic polymers and elastomers is possible by using thermal extraction Desorption gas chromatography–mass spectrometry (TED-GC–MS). KW - Microplastics KW - Mikroplastik KW - TED-GC/MS KW - Microplastics analytic KW - Mikroplastik Massegehalt PY - 2021 VL - 17 IS - 3 SP - 2 EP - 7 PB - MultiMedia (UK) LLC CY - Cranbury AN - OPUS4-52570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Altmann, Korinna A1 - Heymann, S. A1 - Braun, U. A1 - Bannick, C.-G. A1 - Heller, C. A1 - Fuchs, M. A1 - Scheid, C. A1 - Abusafia, A. A1 - Steinmetz, H. A1 - Ricking, M. A1 - Kerndorff, A. T1 - Untersuchungsverfahren von Mikroplastikgehalten im Wasser für Praxis und Wissenschaft N2 - Zielsetzung des vom Bundesministerium für Bildung und Forschung geförderten Projektes RUSEKU war es, repräsentative Untersuchungsstrategien für die Detektion von Mikroplastik mittels TED GC/MS in wässerigen Medien zu ermitteln. Dabei wurden verschiedene Probenahmekonzepte und – verfahren für unterschiedliche Fallgestaltungen und Fragestellungen untersucht, sowie neue Filtersysteme entwickelt. Bei der Detektion der Partikel lag der Fokus auf der Anwendung und Weiterentwicklung der ThermoExtraktion/Desorption-Gaschromatographie-Massenspektrometrie (TED-GC/MS) zur Bestimmung von Mikroplastikgehalten. Anwendung fanden die Methoden bei der Beprobung von Flaschenwasser, Waschmaschinenabläufen, dem urbanen Abwassersystem der Stadt Kaiserslautern, sowie in Oberflächengewässer. KW - Mikroplastik KW - TED-GC/MS KW - Mikroplastik-Analytik KW - Probennahme PY - 2021 VL - 14. Jahrgang IS - 3 SP - 147 EP - 152 PB - Deutschen Vereinigung für Wasserwirtschaft, Abwasser und Abfall CY - Hennef AN - OPUS4-52260 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -