TY - CONF A1 - Schälike, Stefan A1 - Wehrstedt, Klaus-Dieter A1 - Schönbucher, A. T1 - CFD simulation to predict the thermal radiation of large LNG pool fires N2 - Flame temperature (T), surface emissive power (SEP) of Liquefied Natural Gas (LNG) pool fires (d = 1 m, 6.1 m, 30 m) are investigated by CFD (Computational Fluid Dynamics) simulation and compared with experimental results. Time averaged flame temperatures of T = 1320 K, T = 1298 K and T = 1281 K are obtained. Surface emissive power (SEP) of 55 kW=m2, 130 kW=m2 and 230 kW=m2 are predicted. T2 - 5th European combustion meeting 2011 CY - Cardiff, UK DA - 28.06.2011 KW - Pool fire KW - LNG KW - CFD KW - Thermal radiation KW - Surface emissive power PY - 2011 SP - 1 EP - 6 AN - OPUS4-24687 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ferrero, Fabio A1 - Kluge, Martin A1 - Schröder, Volkmar T1 - Numerical analysis of the effect of the electrode distance during the determination of the flammability limits of gases N2 - COMSOL Multiphysics® was used as a tool for the better understanding of the evolution of flow patterns during the induced ignition of gases. A simplified model was developed for the scope, by coupling the weakly compressible Navier Stokes module and the convection and conduction module. The current paper presents the results of the performed simulations. T2 - COMSOL Conference 2011 CY - Ludwigsburg, Germany DA - 26.10.2011 KW - Spark ignition KW - Gas flow KW - Temperature PY - 2011 SN - 978-0-9839688-0-1 N1 - Geburtsname von Kluge, Martin: Beckmann-Kluge, M. - Birth name of Kluge, Martin: Beckmann-Kluge, M. SP - 1 EP - 7 CY - Stuttgart AN - OPUS4-24700 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Scholz, Christian A1 - Woydt, Mathias T1 - Highly stressable and low friction slip-rolling contacts through thin film coatings, uncoated, alternative steels or lubricants N2 - OEMs perceive diamond-like carbon (DLC) coatings as part of a strategy for low frictional tribosystems. Especially the automotive industry anticipates a benefit in applying such coatings in association with the lightweight construction of mechanical parts, for instance in gears and engines. In previous investigations it was shown, that DLC, amorphous carbon (a-C) and tetragonal amorphous carbon (ta-C) coatings can be slip-rolling resistant at least up to ten million load cycles at Hertzian contact pressures P0max of 2.9 GPa lubricated by engine oil at 120°C, Further improvements in load carrying capacity up to P0mean of 2.62 GPa (FN= 5,000 N) were achieved with alternative, available Steel metallurgies as Substrates for thin film coatings. Additional factors, such as influences of the lubrication on the surface chemistry (additives and base oils), wear and friction behavior were investigated. T2 - International tribology conference 2011 CY - Hiroshima, Japan DA - 30.10.2011 KW - Slip-rolling KW - Additives KW - DLC KW - ZrCN KW - High toughness steel KW - High pressure PY - 2011 IS - B4-08 SP - 1 EP - 1 AN - OPUS4-24702 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter T1 - An efficient and clean fuel for high temperature process industries N2 - The use of energetic materials as a main fuel in high temperature process industries are not known to the scientific community as such. This paper highlights some of the features and advantages of using organic peroxides especially di-tert-butyl peroxide (DTBP) in high temperature process industries. The feasibility of using DTBP as a main or supporting fuel in process industries have also been justified with the help of Computational Fluid Dynamics (CFD) simulations. For peroxides requirement of less fuel and air for the same amount of heat flux has been shown. The resulted emission from the combustion of DTBP is also discussed. T2 - 11th Conference on Energy for a Clean Environment CY - Lisbon, Portugal DA - 2011-07-05 KW - Energetic materials KW - Process industries KW - Organic peroxide KW - Di-tert-butylperoxide (DTBP) KW - CFD simulation KW - Emission PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-247071 SP - 1 EP - 10 AN - OPUS4-24707 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stoppel, Markus A1 - Kurz, J.H. A1 - Taffe, Alexander A1 - Boller, C. ED - Chang, F.-K. T1 - Proactive condition assessment in civil engineering using automated multi-sensor systems N2 - Infrastructure is subject to continuous ageing. This has given life cycle management of infrastructure an increasing role. Reliable inspection and monitoring tools are therefore an increasing demand. A combination of different non-destructive test methods is often necessary to receive reliable results for material characterization, flaw detection and the determination of component specific geometry parameters. Regarding concrete structures thickness measurements are combined with flaw detection and additional information about reinforcement and tendon ducts is required. Therefore, a multi-sensor measurement approach is necessary with a high degree of automation. Otherwise a time consuming succession of manual measurements has to be performed which would prevent practical applications. A modular control and data acquisition approach is described and the application of two different automated measurement devices is shown. The BetoScan system consists of a self-navigating mobile robot. The system is especially designed for the investigation of reinforced concrete floors exposed to de-icing salts. The data acquisition of the OSSCAR system a multi-sensor scanner is similar to the robot approach. These different applications are based on a similar kernel allowing the modular use of different contact and noncontact sensors. The described general concept of multi-sensor data acquisition and data analysis presented here is not limited to the field of civil engineering applications. T2 - 8th International workshop on structural health monitoring 2011 CY - Stanford, CA, USA DA - 13.09.2011 KW - Multi sensor KW - Data acquisition KW - Assessment of concrete structures KW - Scanner KW - NDT PY - 2011 SN - 978-1-60595-053-2 VL - 2 SP - 2359 EP - 2366 PB - DEStech Publications, Inc. AN - OPUS4-24692 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thiele, Marc A1 - Baeßler, Matthias A1 - Rogge, Andreas A1 - Pirskawetz, Stephan ED - Rogge, A. ED - Meng, B. T1 - Schädigungsevolution in Beton unter hochzyklischen Ermüdungsbeanspruchungen N2 - Unter zyklischen Belastungen findet im Beton, wie bei anderen Materialien auch, ein Ermüdungsprozess statt. Im derzeitigen Erkenntnisstand zum Materialverhalten des heterogenen Betons gibt es gerade bei dessen Ermüdungsverhalten momentan noch viele nicht oder nicht ausreichend geklärte Fragestellungen. Deshalb befasst sich der vorliegende Beitrag mit der experimentellen Untersuchung des Ermüdungsverhaltens von Beton, speziell unter hochzyklischen Druckschwellbelastungen. Im Fokus der Untersuchungen stehen dabei die während der gesamten Lebensdauer im Materialgefüge ablaufenden Prozesse, die zu Veränderungen im Materialverhalten und schließlich auch bis zum Ermüdungsversagen führen können. Ziel ist es, eine möglichst realitätsnahe Beschreibung des im Materialgefüge ablaufenden Ermüdungsprozesses zu entwickeln. T2 - 52. DAfStb-Forschungskolloquium CY - Berlin, Germany DA - 07.11.2011 KW - Beton KW - Ermüdung KW - Schädigung PY - 2011 SN - 978-3-9814281-0-0 IS - E4 SP - 172 EP - 181 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-24724 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter T1 - Combustion of peroxy-fuels N2 - The diffusion flames of organic peroxides exhibit quite different characteristics than hydrocarbons. What makes them interesting to study is their fast burning behaviour. As a result the flame temperature enhances and so does the thermal radiation. Due to all these they demand safe handling during processing. However, they can be utilised at several places in different industries where a fuel with fast burning, high temperature and intense radiation are desired. Some of the possibilities to use them as a main or supporting fuel in a wide range of industrial utilities are the major content of this paper. T2 - ERCOFTAC conference - Highly resolved experimental and numerical diagnostics for turbulent combustion CY - Rouen, France DA - 25.05.2011 KW - Energetic materials KW - Process industries KW - Organic peroxide KW - Di-tert-butyl peroxide (DTBP) KW - CFD simulation KW - Emission PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-247083 SP - 1 EP - 5 AN - OPUS4-24708 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rabe, Torsten A1 - Naghib Zadeh, Hamid A1 - Glitzky, C. A1 - Töpfer, J. T1 - Integration of Ni-Cu-Zn ferrite in LTCC-modules N2 - Integration of magnetic functional components in LTCC Circuit boards calls for co-firing of dielectric and ferrite tapes. Ni-Cu-Zn ferrites with permeability of p=900 were developed which can be fully densified at the Standard LTCC sintering temperature of 900 °C. Successful co-firing of this ferrite with dielectric tapes requires the adaptation of the shrinkage behavior of the materials as well as the thermal expansion during the cooling period - especially in the temperature range below the transformation point of the glassy phase of the dielectric tape. To match these preconditions, a new dielectric LTCC material with steep sintering curve and high thermal expansion coefficient was designed. Sintered multilayer composed of Ni-Cu-Zn ferrite and tailored dielectric tapes are free of cracks and possess no open porosity. No significant interdiffusion between the ferrite and dielectric tapes was found by EDX measurements. Compared to pure ferrite laminates the permeability of co-sintered Ni-Cu-Zn ferrite layers is drastically reduced to 400, i.e. a decrease of more than 50 %. To investigate the origin of this permeability reduction, Ni-Cu-Zn ferrite laminates were sintered separately, and in combination with alumina release tapes or dielectric tapes, respectively. SEM and EDX analysis of co-fired laminates reveal differences in the ferrite grain growth behavior. Ferrite laminates with homogeneous microstructure and grain size up to 50 pm exhibit large permeability. However, growth of ferrite grains does not take place near the interface between ferrite and release or dielectric tapes. There is a strong correlation between high permeability and volume fraction of large ferrite grains. Regions of fine and coarse grains inside the ferrite layers show different bismuth concentration; the Bi-content is larger in regions of fine ferrite grains. T2 - CICMT 2011 - 7th International conference and exhibition on ceramic interconnect and ceramic microsystems technologies CY - San Diego, CA, USA DA - 05.04.2011 KW - LTCC KW - Co-firing KW - Ferrite KW - Shrinkage behavior KW - Constrained sintering KW - Keramische Multilayer KW - Grenzflächenreaktion PY - 2011 SN - 0-930815-92-0 SP - 000266 EP - 000275 PB - IMAPS, International Microelectronics and Packaging Society AN - OPUS4-25072 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grasse, Fabian A1 - Trappe, Volker A1 - Thöns, Sebastian A1 - Said, Samir ED - De Roeck, G. ED - Degrande, G. ED - Lombaert, G. ED - Müller, G. T1 - Structural health monitoring of wind turbine blades by strain measurement and vibration analysis N2 - Wind turbine blades have to withstand a high number of load cycles in mostly hard weather conditions over 20 years. In a research project BAM and several partners have designed, evaluated and tested a condition monitoring system for all parts of a wind turbine. At a rotorblade with a length of 58 m fibre bragg grating sensors were applied for in-service strain measurement. Additionally a complex test rig was designed to enable real biaxial loading conditions at a representative test rotor blade to simulate the mechanical loading conditions in the lab. In this test blade with a length of 8 m also fibre bragg grating sensors were implemented to determine their influences for the structure and the condition monitoring system. Vibration measurements were carried out at different test phases. The results were compared with finite element strain and modal analysis. T2 - EURODYN 2011 - 8th International conference on structural dynamics CY - Leuven, Belgium DA - 04.07.2011 KW - Rotor blade KW - Test blade KW - Modal analysis KW - Condition monitoring PY - 2011 SN - 978-90-760-1931-4 IS - MS25 Tue SP - 3490 EP - 3497 AN - OPUS4-25076 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Grasse, Fabian A1 - Trappe, Volker A1 - Hickmann, Stefan ED - Grellmann, W. T1 - Zustandsüberwachung von Rotorblättern - Konzeptstudie mittels Bauteilkomponentenversuch T2 - DVM-Tagung Werkstoffprüfung 2011 - Neue Entwicklungen in der Werkstoffprüfung - Herausforderungen an die Kennwertermittlung CY - Berlin, Deutschland DA - 2011-12-01 KW - Rotorblatt KW - Faserverbundwerkstoffe KW - Modalanalyse KW - Zustandsüberwachung KW - Faser-Bragg-Gitter-Sensoren KW - Rotor blade KW - Fibre reinforced plastics KW - Modal analysis KW - Condition monitoring KW - Fibre bragg grating sensors PY - 2011 SN - 978-3-9814516-1-0 SN - 1861-8154 N1 - Serientitel: DVM-Bericht – Series title: DVM-Bericht IS - 643 SP - 167 EP - 172 AN - OPUS4-25078 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Wrobel, Norma A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Einstrahlgeometrie und Erkennbarkeit von Objekten in der Röntgenrückstreuradiographie N2 - Abweichend von der gängigen Vorgehensweise, mit einem Bleistiftstrahl die Lage eines Bildpunktes festzulegen und die rückgestreute Strahlung großflächig aufzunehmen, bietet die neu entwickelte Kamera Unabhängigkeit von Einstrahl- und Blickrichtung. Ausgestattet mit einer 'Optik' für hochenergetische Strahlung, wie die bereits beschriebene Schlitzblendenkamera, ist die variable Gestaltung von Einstrahl- und Blickrichtung möglich. Damit eröffnet sich die Chance, Strahlung absorbierende Details in einem Objekt sichtbar werden zu lassen, die sonst von einer streuenden Umgebung überstrahlt würden. Zudem wird gezeigt, wie sich das Erscheinungsbild von Objekten umgebungsbedingt im Rückstreubild ändern kann. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Deutschland DA - 30.05.2011 KW - Röntgenrückstreuradiographie KW - Schlitzblendenkamera KW - Varibale Einstrahlgeometrie PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250627 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Poster 20) SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25062 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Ewert, Uwe A1 - Zvizdic, D. A1 - Krstelj, V. T1 - Die EFNDT Arbeitsgruppe 5 'Öffentliche Sicherheit mit ZfP-Techniken' neu formiert N2 - Für die öffentliche Sicherheit wird gesorgt, indem Gefahren rechtzeitig entdeckt werden. Deren Ursprung kann im technischen oder menschlichen Versagen liegen, womit im englischen Sprachraum zwischen 'Safety' und 'Security' unterschieden wird. Hinsichtlich der Folgen verschwimmt aber dieser Unterschied, obwohl für deren Verhinderung unterschiedliche Zuständigkeiten existieren. Bezüglich des gemeinsamen Interesses und auch überlappender Methoden und Vorgehensweisen würden beide Seiten gewinnen können, wenn es eine Brücke zwischen ihnen gäbe. Eine solche zu schaffen hat sich die EFNDT Arbeitsgruppe (Working Group) 5 zur Aufgabe gestellt. Gestaltet werden soll sie durch gemeinsame Veranstaltungen und Seminaren, die zur Bildung von Konsortien und der Durchführung gemeinsamer Projekte führen sollen. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 03.05.2011 KW - EFNDT Working Group 5 KW - Technische und öffentliche Sicherheit KW - Gemeinsamkeiten in ZfP und öffentlicher Sicherheit KW - Brückenbildung zwischen Zuständigkeitsbereichen PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250631 SN - 978-3-940283-33-7 VL - 127 SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-25063 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Hasenstab, A. A1 - Bücherl, T. A1 - Schillinger, B. T1 - Partielle Tomographie mit Neutronen zur Beurteilung von Leimschichten in Holz N2 - Verleimte Holzproben wurden je nach Größe mit thermischen (ANTARES) bzw. schnellen Neutronen (NECTAR) an der Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) der Technischen Universität München in Garching untersucht. Entweder ließen die durchstrahlbare Schichtdicke oder die eingeschränkte Strahlgeometrie es nicht zu, das Probenteil allseitig zu durchstrahlen. Um dennoch innere Strukturen wie Leimschichten zumindest mit einem eingeschränkten Winkelbereich tomographisch darzustellen, wurde mit Hilfe des Slice-Theorems erfolgreich rekonstruiert. Ein Brett von 2 cm Dicke wurde mit thermischen Neutronen erfolgreich untersucht, ein größeres mit schnellen. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Neutronentomographie KW - Eingeschränkter Winkelbereich KW - Holz PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250649 SN - 978-3-940283-33-7 VL - 127 SP - 1 EP - 6 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-25064 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Bücherl, T. A1 - Schillinger, B. A1 - Hasenstab, A. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Limited view tomography of wood with fast and thermal neutrons N2 - Neutrons are absorbed particularly by hydrogen containing materials so they can be used as a tool for visualising heterogeneous density distributions of organic materials. Penetration limits are set by the layer thicknesses and the neutron energies applied. In case of specimens with a flat shape the situation may be encountered that the object only could be penetrated in selected directions. In addition, the overall size may exceed the beam diameter and thus the viewing window if a certain region of interest should be studied by tomography without destroying the integrity of the specimen. This study shows the capabilities and limits of thermal and fast neutrons to investigate flat wooden specimens such as boards and girders by neutron tomography under such circumstances. Taking projections was impaired either by the limits of penetrability or by the total size of the object. As a consequence, projections were included for reconstruction only from a limited angular range of 90°. It could be shown that an approach based on the slice theorem was capable to visualise structural features along the beam directions while simply omitting the perpendicular ones without causing additional artefacts. Small samples with a thickness of up to 2 cm but several times broader could be studied with the ANTARES facility of the FRM II neutron source in Garching providing thermal neutrons while larger objects required a beam of higher energy as available in the NECTAR facility of the same institution. The fast (fission) neutrons (1.5 – 2 MeV) of this site allowed investigating an area of interest inside a girder with a cross section of 23.5 x 49 cm². Internal features such as inclusions could be detected as well as a heterogeneous density distribution in glue layers. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Computed tomography KW - Slice theoreme KW - Limited angle tomography PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-250663 SN - 978-3-940283-34-4 VL - 128 SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-25066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schurig, Michael A1 - Klinger, Christian A1 - Schöne, Dieter A1 - Bork, Claus-Peter A1 - Klingbeil, Dietmar ED - Christ, H.-J. ED - Berger, C. T1 - Very high cycle fatigue testing on an electrodynamic shaker system N2 - Fatigue testing in the VHCF ränge requires testing machines with increased frequencies. However, application of energy-saving resonance testing leads to a linkage between test frequency and specimen Parameters. The frequency ränge and the available forces of the testing machine are limiting possible specimen dimensions. Electrodynamic shakers combine test frequencies up to 4000 Hz with forces in the kN range. Thus, a relatively wide range of tests is possible which allows studying the influence of specimen size on VHCF behaviour. Electrodynamic shakers as well as the respective Computer control Systems and Vibration measurement techniques are well established in scientific and technical applications. We present results of a first study of VHCF testing on electrodynamic shakers conducted at BAM. Test frequency, specimen size and stress levels have been varied. One goal is to balance the needs of materials testing with the Standard test Systems of environmental Simulation to provide a powerful and flexible tool for very high cycle fatigue testing. Further investigation to optimize the technique is required. T2 - VHCF5 - 5th International conference on very high cycle fatigue CY - Berlin, Germany DA - 28.06.2011 KW - Electrodynamic shaker KW - Resonance testing KW - Variable frequency KW - Envrionmental simulation KW - Specimen size KW - Two-degree-of-freedom system KW - VHCF KW - Shaker KW - Elektrodynamisch KW - Prüfung PY - 2011 SN - 978-3-9814516-0-3 SP - 433 EP - 438 AN - OPUS4-25067 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ohm, Katrin A1 - Baer, Wolfram ED - Grellmann, W. T1 - Einfluss der Verfahrenstechnik und der Werkstoffprüfung auf den im Zugversuch zu ermittelnden Verformbarkeitskennwert Agt von Betonstählen N2 - Die Streuung der Agt-Werte von Betonstahl bleibt durch die Variation der Prüfbedingungen (Temperatur, Geschwindigkeit) innerhalb der prüfnormseitig zulässigen Grenzen weitgehend unbeeinflusst. Gleichzeitig führt die Variation der Prüfbedingungen zu einer signifikanten, für die Produktabnahme relevanten Änderung des Niveaus von Agt. Die Auswertemethodik des Zugversuches (Festlegung der Höchstkraft, Wahl des Verfahrens zur Agt-Bestimmung) hat einen signifikanten Einfluss auf Niveau und Streuung von Agt. Es werden Empfehlungen zur Minimierung der Streuung von Agt gegeben. T2 - DVM-Tagung Werkstoffprüfung 2011 - Neue Entwicklungen in der Werkstoffprüfung - Herausforderungen an die Kennwertermittlung CY - Berlin, Germany DA - 01.12.2011 KW - Betonstahl KW - Zugversuch KW - Gesamtdehnung bei Höchstkraft KW - Kennwertstreuung KW - Prüfmethodik KW - Reinforcing steel KW - Tensile test KW - Percentage total extension at maximum force KW - Scatter of results KW - Test method PY - 2011 SN - 978-3-9814516-1-0 SN - 1861-8154 N1 - Serientitel: DVM-Bericht – Series title: DVM-Bericht IS - 643 SP - 279 EP - 284 AN - OPUS4-25068 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jakubcová, Petra A1 - Rübner, Katrin A1 - Schnell, A. T1 - Leichte Gesteinskörnungen auf der Basis thermisch und hydrothermal hergestellter Blähgranulate aus Abbruchabfällen N2 - Beton mit leichten Gesteinskörnungen (Leichtzuschlägen) ist seit dem Altertum bekannt. Leichte Gesteinskörnungen vulkanischen Ursprungs wurden bereits zur Errichtung der Maya-Pyramiden in Mexiko und von monumentalen Bauwerken im Römischen Reich verwendet. Zu den berühmtesten Beispielen der ersten Anwendung von Leichtbeton in Europa gehören das Kolosseum und das Pantheon in Rom, Hier wurden sowohl natürliche als auch künstliche Zuschlagstoffe, wie Bims, Lava und zerkleinerter Ziegelsplitt, benutzt. Mit steigender Nachfrage nach leichten Gesteinskörnungen und einer weltweit begrenzten Verfügbarkeit natürlicher Leichtzuschläge wurden synthetische leichte Gesteinskörnungen entwickelt. Ihre großtechnische Herstellung begann nach dem Ersten Weltkrieg. Heute werden leichte Gesteinskörnungen in einem breiten Schüttdichtespektrum von 100 bis 1200 kg/m3 hergestellt. Sie stellen einen wichtigen Teil der Gesteinskörnungen in der Baubranche dar. T2 - 15. Seminar 'Beschichtungen und Bauchemie' - Reaktive und filmbildende organische Bindemittel: Der Klimawandel und der Einfluss auf die Rezepturen Teil II CY - Kassel, Germany DA - 29.11.2011 KW - Sekundärrohstoffe KW - Sekundäre Gesteinskörnung KW - Recycling KW - Leichtbeton PY - 2011 SP - 55 EP - 66 AN - OPUS4-25086 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gründer, Klaus-Peter A1 - Köppe, Enrico A1 - Kadoke, Daniel T1 - Optische 3D-Referenzierung eines funkgestützten Multisensorsystems zur Bewegungsanalyse gefährdeter Personen N2 - Ein stereo-fotogrammetrisches Messverfahren wurde zur quantitativen Analyse der Bewegungssignale eines elektrischen Multi-Sensorsystems eingesetzt. Der Vergleich von Weg- und Winkel-Zeitverläufen zeigte bereits eine recht gute Übereinstimmung, verdeutlichte jedoch auch die Notwendigkeit einer weiterzuentwickelnden Kalibriermethodik. Die Stereo-Videogrammetrie hat sich als Referenzverfahren zur Analyse und Validierung dreidimensional ausgelegter elektrischer Bewegungssensorik für den Nahbereich bewährt. T2 - 3D-NordOst 2011 - 14. Anwendungsbezogener Workshop zur Erfassung, Modellierung, Verarbeitung und Auswertung von 3D-Daten CY - Berlin, Germany DA - 08.12.2011 KW - Stereo-Videogrammetrie KW - Funkgestützte Sensorik KW - Bewegungsanalyse PY - 2011 SN - 978-3-942709-03-3 SP - 33 EP - 38 AN - OPUS4-25103 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Liehr, Sascha A1 - Krebber, Katerina ED - De Roeck, G. ED - Degrande, G. ED - Lombaert, G. ED - Müller, G. T1 - A novel quasi-distributed long-gauge fiber optic strain sensor system for dynamic measurement N2 - We present a novel technique based on incoherent optical frequency domain reflectometry (OFDR) to measure length changes quasi-distributed between reflection points in optical fibres. The technique enables length changes to be measured with a resolution better than 1 µm and allows for static and dynamic measurement capabilities up to 2 kHz. We demonstrate that dynamic measurements of multiple fibre sections can be conducted independently from each other with high precision. Due to the precise and dynamic measurement capabilities, the proposed sensor system is expected to open new fields of application, especially in the structural-health-monitoring sector. Possible applications are discussed in the paper. T2 - EURODYN 2011 - 8th International conference on structural dynamics CY - Leuven, Belgium DA - 04.07.2011 KW - Distributed sensor KW - Strain sensor KW - Optical fiber sensor KW - Structural health monitoring KW - OFDR KW - Length change measurement KW - Dynamic sensor PY - 2011 SN - 978-90-760-1931-4 SP - 2097 EP - 2102 AN - OPUS4-24347 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hothan, Sascha A1 - Ehlig, D. ED - Ortlepp, R. ED - Curbach, M. T1 - Hochtemperaturverhalten von Stahlbetonplatten mit Textilbetonverstärkung N2 - Die Verwendung von Endlosfilamenten aus Carbon als Be-wehrungsmaterial für Beton, sogenannter Textilbeton, bietet die Möglichkeit der Sanierung und der Verstärkung bestehender Stahlbetonkonstruktionen. Dabei muss die Frage nach dem Feuerwiderstand von derart verstärkten Tragwerken be-antwortet werden. Aufschluss darüber liefern Brandversuche. Mit Textilbeton verstärkte Stahlbetonplatten haben in Brandversuchen nach der Einheits-Temperaturzeitkurve bei 33 % der Traglast mehr als 60 Minuten standgehalten. Bei 50 % der Traglast kam es nach einer Branddauer von 55 Minuten, bei 65 % nach 30 Minuten, zu einem Zugversagen der textilen Verstärkungsschicht. Bei während des Brandes unbelasteten bzw. gering belasteten Platten lagen die im Anschluss ermittelten Resttragfähigkeiten bei 65 % der Bruchlast nach 30 Minu-ten Branddauer bzw. bei 50 % der Bruchlast nach 60 Minuten Branddauer. Wäh-rend und nach der Beflammung waren zunehmende Durchbiegungen und Rissbreiten erkennbar. Es traten aber keine Abplatzungen auf, weshalb die Ver-stärkungsschicht aus Textilbeton als zusätzliche Betondeckung für die Stahlbe-wehrung angerechnet werden kann. Diese außerordentlich positiven Ergebnisse zeigen, dass für verstärkte Konstruktionen Feuerwiderstandsklassen von F60 bzw. R60 ohne zusätzliche Maßnahmen erreicht werden können. Dies ist von ho-her Relevanz für die wirtschaftliche Anwendung dieser Verstärkungsmethode. Für ein umfassendes Verständnis der Interaktion zwischen den Bewehrungen Textil und Stahl sowie der Versagensmechanismen während des Brandes, sind weitere Erkenntnisse über die mechanischen Eigenschaften von Textilbeton im Hochtemperaturbereich nötig. Auch der Einfluss der Oxidation des Carbons konnte nicht abschließend beurteilt werden. 354 HOTHAN und EHLIG: Hochtemperaturverhalten von Stahlbetonplatten mit TRC-Verstärkung Summary: Using endless carbon filaments for concrete reinforcement, so called textile reinforced concrete, the possibility of reconstruction and strengthening of existing concrete structures arises. The question concerning fire resistance of structures strengthened like this has to be answered. Fire tests provide answers. Steel reinforced concrete slabs strengthened with textile reinforced concrete load-ed with 33 % of ultimate load survived an ISO-fire for 60 minutes. Loaded with 50 % and 65 % of ultimate load the slabs failed after 55 minutes and 30 minutes of fire exposure due to tension failure of the textile reinforcement layer. Slabs not loaded or with a low load level during fire exposure showed remaining bearing resistances of 65 % of ultimate load after 30 minutes and 50 % of ultimate load after 60 minutes of fire exposure. During and after fire exposure rising deflec-tions and growing crack widths were observed. However no spalling occurred. Therefore the textile reinforced concrete layer can be taken into account as con-crete covering for the steel reinforcement. Those extraordinary positive results document, that reinforced concrete structures with additional fibre reinforced concrete can achieve fire resistance classes of R60 without additional provisions. To achieve comprehensive understanding of interaction between steel and fibre reinforcement and failure mechanisms in case of fire more knowledge concerning the mechanic properties of fibre reinforced concrete at high temperatures is es-sential. The influence of oxidation of the carbon fibres could not fully be an-swered. T2 - 6. Kolloquium zu textilbewehrten Tragwerken (CTRS6) CY - Berlin, Germany DA - 19.09.2011 KW - Feuerwiderstand KW - Abplatzen KW - Textilbeton KW - Brandbeanspruchung KW - Biegebelastung PY - 2011 SN - 978-3-86780-245-1 SP - 353 EP - 367 AN - OPUS4-24635 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehlig, D. A1 - Hothan, Sascha ED - Koenders, E.A.B. ED - Dehn, F. T1 - Reinforced concrete slabs strengthened with textile reinforced concrete subjected to fire N2 - Thin layers of textile reinforced concrete (TRC) can be used as strengthening for reinforced concrete (RC) slabs or beams to increase their foad-bearing capacity. The concrete matrix consists of a fine-grained concrete with a thickness of 8 to 15 mm. Information on the behaviour of strengthened structures subjected to fire is of particular inlerest for practical applications of this innovative construction method. A total of 7 RC slabs with Steel reinforcement were produced: 2 slabs were used as reference and 5 slabs were strengthened with three layers of textile reinforcement. Ultimate capacity of reference slabs and particular TRC strengthened slabs was determined from statie load results fom 4-point-bending tests. Fire tests on these slabs were carried out with utilization fectors using a Standard temperature curve (ISO-834-1) for fire testing. Test loads varied between 0 % and 65 % ofuMmate load. To detect temperatures during fire exposure thermocouples were arranged throughout the cross-section of the slabs. Depending on the utilization the slabs were exposed to fire for 30 minutes or for 60 minutes. In some cases bending fäilure occurred, in other cases the slabs survived. None of the specimens exhibited any visual damage or concrete spalling during fire exposure. Results of deformation measurements and residual strength measurements are presented. Even though mechanisms are not fifily understood, it is important to discuss the presumable reasons for the surprisingiy positive test results. It is presumed tbat the key mechanisms contributing to the outstanding fire resistance capability presented are: superior crack control of the TRC and load redistribution between textile and Steel reinforcement as well as the primary load transfer directly into the slabs. T2 - 2nd International RILEM workshop on concrete spalling due to fire exposure CY - Delft, The Netherlands DA - 05.10.2011 KW - Textile reinforced concrete KW - Fine-grained concrete KW - Carbon fibres KW - Bending load KW - Fire exposure PY - 2011 SN - 978-2-35158-118-6 VL - PRO 80 SP - 419 EP - 426 PB - RILEM Publications AN - OPUS4-24636 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Scholz, Christian A1 - Spaltmann, Dirk A1 - Woydt, Mathias T1 - Höchstbelastbare Wälzkontakte mit geringer Misch-/Grenzreibungszahl N2 - Leichtbaustrategien im Antriebsstrang erhöhen durch Downsizing die Hertz’schen Kontaktpressungen und die mechanischen Lasten. Dadurch müssen neben wälzbeständigen Stählen auch dazu passende reibungsmindernde Konzepte gefunden werden, in der vorliegenden Arbeit wurden alternative, hoch zähe Stähle mit einer Wälzbeständigkeit bis Pomax = 4,2 GPa untersucht, welche mit geeigneten Grundöl- und Additivkombinationen die Reibungszahlen herunter auf 0,025 reduzieren konnten. Diese alternativen Stahllegierungen erlauben nicht nur an der Zahnflanke sehr hohe Kontaktpressungen, sie bieten außerdem entsprechende Zähigkeits- und Festigkeitseigenschaften für den Zahnfuß. In vorangegangenen Untersuchungen wurde eine Vielzahl verschiedener Dünnschichten auf ihre Überrollbeständigkeit unter Extrembeanspruchungen validiert. Allerdings zeigte sich bei den meisten Dünnschichten ein Qualitätsunterschied von Charge zu Charge. Unter Verwendung verschiedener organischer, metallorganischer und anorganischer Additive konnten, sich daran anschließende Versuche, vielversprechende Ergebnisse erzielt werden. Sämtliche Versuche unter extremen Beanspruchungen wurden bei +120°C Öltemperatur auf Zwei-Scheiben-Tribometern vom Typ AMSLER und 2Disk von Optimol Instruments unter Misch-/Grenzreibungsbedingungen durchgeführt und die tribologischen Eigenschaften der neuartigen, unbeschichteten Stähle und in Relation zu leistungsstarken DLC-/ZrCN Dünnschichten gesetzt. T2 - 52. Tribologie-Fachtagung - Reibung, Schmierung und Verschleiß - Forschung und praktische Anwendungen CY - Göttingen, Deutschland DA - 26.09.2011 KW - Hochzähe Stähle KW - DLC KW - ZrCN KW - Dünnschichten KW - Extrembeanspruchung KW - Polyglykole KW - Additive PY - 2011 SN - 978-3-00-035439-7 VL - I SP - 11/1 EP - 11/16 AN - OPUS4-24611 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vila-Comamala, J. A1 - Diaz, A. A1 - Guizar-Sicairos, M. A1 - Gorelick, S. A1 - Guzenko, V.A. A1 - Karvinen, P. A1 - Kewish, C.M. A1 - Färm, E. A1 - Ritala, M. A1 - Mantion, Alexandre A1 - Bunk, O. A1 - Menzel, A. A1 - David, C. ED - Morawe, C. ED - Khounsary, A.M. ED - Goto, S. T1 - Characterization of a 20-nm hard X-ray focus by ptychographic coherent diffractive imaging N2 - Recent advances in the fabrication of diffractive X-ray optics have boosted hard X-ray microscopy into spatial resolutions of 30 nm and below. Here, we demonstrate the fabrication of zone-doubled Fresnel zone plates for multi-keV photon energies (4-12 keV) with outermost zone widths down to 20 nm. However, the characterization of such elements is not straightforward using conventional methods such as knife edge scans on well-characterized test objects. To overcome this limitation, we have used ptychographic coherent diffractive imaging to characterize a 20 nm-wide X-ray focus produced by a zone-doubled Fresnel zone plate at a photon energy of 6.2 keV. An ordinary scanning transmission X-ray microscope was modified to acquire the ptychographic data from a strongly scattering test object. The ptychographic algorithms allowed for the reconstruction of the image of the test object as well as for the reconstruction of the focused hard X-ray beam waist, with high spatial resolution and dynamic range. This method yields a full description of the focusing performance of the Fresnel zone plate and we demonstrate the usefulness ptychographic coherent diffractive imaging for metrology and alignment of nanofocusing diffractive X-ray lenses. T2 - SPIE Optics and photonics CY - San Diego, USA DA - 20.08.2011 KW - X-ray imaging KW - Diffractive X-ray optics KW - Electron beam lithography KW - Ptychographic coherent diffractive imaging PY - 2011 DO - https://doi.org/10.1117/12.893235 SN - 0277-786X N1 - Serientitel: Proceedings of SPIE – Series title: Proceedings of SPIE VL - 8139 SP - 81390E-1 EP - 81390E-7 AN - OPUS4-24613 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kalbe, Ute A1 - Bredow, Andrea A1 - Berger, Wolfgang A1 - Wessel-Bothe, Stefan A1 - Keller, T. T1 - Optimierung des Säulenperkolationsverfahrens durch Automatisierung N2 - Elutionstests im Labormaßstab werden zur Ermittlung der Freisetzung von Schadstoffen aus Böden oder mineralischen Abfällen für die Verwertung in technischen Erdbau-werken durchgeführt. Sie sollen die Feldbedingungen möglichst realitätsnah wider-spiegeln und auch die Beurteilung der Freisetzung von Schadstoffen über längere Zeiträume ermöglichen. Aus diesem Grunde werden im Entwurf der novellierten BBodSchV neue Verfahren zur Eluatgewinnung aus den genannten Materialien festgeschrieben. T2 - DBG-Jahrestagung, Kommission VI, 'Böden verstehen - Böden nutzen - Böden fit machen' CY - Berlin, Germany DA - 03.09.2011 KW - Schadstofffreisetzung KW - Säulenperkolation KW - Werkstoffauswahl KW - Elutionsverfahren PY - 2011 UR - http://eprints.dbges.de/565/1/Berichte_der_DBG_Kalbe_2753.pdf SP - 1 EP - 4 AN - OPUS4-24648 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Berger, Wolfgang A1 - Kalbe, Ute A1 - Krüger, Oliver A1 - Litzba, Andreas T1 - Vergleich der Ergebnisse von Übereinstimmungstests bei Säulen- und Schüttelversuchen N2 - In der Bundes-Bodenschutz- und Altlasten-verordnung (BBodSchV) und im Arbeits-entwurf der Novellierung ist für den Wirkungspfad Boden-Grundwasser eine Sickerwasserprognose vorgesehen, um die Gefahren, die von kontaminierten Stand-orten für das Schutzgut Grundwasser ausgehen, beurteilen zu können. Bei der Sickerwasserprognose kann u.a. auf der Grundlage von Materialuntersuchungen im Labor die Quellstärke kontaminierter Ma-terialen ermittelt werden, welche dann bei Transportmodellierungen Berücksichtigung findet. Der Entwurf der Novellierung der BBodSchV sieht für die Ermittlung der Quellstärke den Übereinstimmungstest des Säulenversuchs nach DIN 19528 bis zu einem Wasser/Feststoff - Verhältnis (W/F) von 2 l/kg für anorganische und organische Stoffe (PAK) oder den Schüttelversuch nach DIN 19529 für anorganische Stoffe und E DIN 19527 für organische Stoffe auch jeweils mit einem W/F von 2 l/kg vor. Die Zulassung beider Elutionsverfahren setzt die Gleichwertigkeit der Ergebnisse beider Verfahren voraus. Im Folgenden werden die Ergebnisse des Vergleichs der Auslaugung von polyzyklischen aromat-ischen Kohlenwasserstoffen (PAK) aus unterschiedlichen Böden mit Hilfe beider Elutionsverfahren vorgestellt. T2 - DBG-Jahrestagung, Kommission VI, 'Böden verstehen - Böden nutzen - Böden fit machen' CY - Berlin, Germany DA - 03.09.2011 KW - Elutionsverfahren KW - Übereinstimmungstest KW - Säulenverfahren KW - Schüttelverfahren KW - Kontaminierte Böden KW - Polyzyklische aromatische Kohlenwasserstoffe (PAK) PY - 2011 UR - http://eprints.dbges.de/551/1/Berichte_der_DBG_Berger3376.pdf SP - 1 EP - 2 AN - OPUS4-24649 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Baer, Wolfram A1 - Klingbeil, Dietmar T1 - Entwicklung einer Key Curve-Methode für Gusseisen mit Kugelgraphit bei dynamischer Beanspruchung T2 - 37. MPA-Seminar - Werkstoff- & Bauteilverhalten in der Energie- & Anlagentechnik CY - Stuttgart, Deutschland DA - 2011-10-06 KW - Dynamic fracture mechanics KW - Crack resistance curve KW - Single specimen technique KW - Key curve PY - 2011 SP - 35.1 EP - 35.19 AN - OPUS4-24618 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von der Ehe, Kerstin A1 - Jaunich, Matthias A1 - Wolff, Dietmar T1 - UHMW-PE - a shielding material with special properties influenced by radiation N2 - Ultra high molecular weight polyethylene (UHMW-PE) - due to its high hydrogen content - is used as neutron shielding material in casks for storage and transport of radioactive materials. Besides this, UHMW-PE - as a high-performance polymer - has been used for several years in medical technology due to its excellent slip and wear properties. Due to the special properties of UHMW-PE which result basically from its extreme chain lengths and its high degree of crystallinity, it is predestinated for the aforementioned applications. In both cases, irradiation and its impact on the molecular structure of polyethylene play an important role. In the first case, irradiation exists as a by-product of inserting the radioactive material in the cask. Hence PE has to withstand any type of degradation affecting safety relevant aspects to be applicable for long term radiation shielding purposes for instance over a period of 40 years. In the second case irradiation is applied deliberately for purposes such as sterilization and crosslinking, leading to partial improvement of the mechanical properties (e.g. fracture toughness, crack propagation resistance, wear resistance) and better Chemical stability. Specifically concerning their use in the field of medical technology, different types of UHMW-PE have been objects of numerous publications. It is generally accepted that two parallel and competitive processes, based on chain scission and reactions of Ccentered radicals and molecular fragments, occur in PE as a consequence of radiation: radical recombination accounts for crosslinking, together with some disproportionation, formation of low molecular weight fragments, and recrystallization. Furthermore, formation of oxygenated structures in the presence of traces of oxygen is an antagonist of the C-centered radicals. Radiation induced scission preferentially takes place in the amorphous phase and noncrystalline surface of the crystals. It is followed by folding of molecular fragments, crystallinity growth and increased perfection in the crystal lamellae [4, 5]. Chain scission results in shorter polymer molecules, fewer entanglements, and consequently, increased molecular mobility. The scope of our investigation comprises an estimation of the radiation and thermal impact on the molecular and supra molecular structure of the two types of PE used for neutron shielding cask components. A further point which is worth to explore is to what extent these changes are detectable by thermo-analytical (TA) methods, such as Differential Scanning Calorimetry (DSC), Thermo Mechanical Analysis (TMA), Dynamic Mechanical Analysis (DMA) and Thermogravimetry (TG). Additionally FT-IR and solubility measurements have been performed. In our studies we focused on the UHMW-PE material GUR 4120 which was y irradiated at RT and compared to the untreated material. T2 - Jahrestagung Kerntechnik 2011 CY - Berlin, Germany DA - 17.05.2011 PY - 2011 SP - 1 EP - 5 AN - OPUS4-24620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wachsmuth, Janne T1 - Wellenform basierte Quellenlokalisierung im Vergleich zu konventionellen Methoden N2 - Für eine 10 mm dicke Stahlplatte kann ein Bandpass so gesetzt werden, dass alle vorhandenen Wellenmoden mit derselben Schallgeschwindigkeit eintreffen. Anhand von Ortungsabweichungen und Ortungsunsicherheitswerten kann gezeigt werden, dass im Vergleich zu herkömmlichen Methoden der Quellenortung die Ortungsgenauigkeit durch eine Frequenzfilterung verbessert werden kann. T2 - 18. Kolloquium Schallemission CY - Wetzlar, Deutschland DA - 27.10.2011 KW - Schallemissionsprüfung KW - Ermüdungsrisswachstum KW - Korrosion PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-246612 SN - 978-3-940283-37-5 SP - 1 EP - 6 PB - DGZfP-BB 131 AN - OPUS4-24661 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wachsmuth, Janne A1 - Bohse, Jürgen T1 - Schallemissionsanalyse von Schadensmechanismen an Feinkornstahl N2 - In dieser Arbeit werden geschweißte Platten aus dem Feinkornstahl P460NL1 untersucht. Korrosion und Ermüdungsrisswachstum werden als Schadensmechanismen in das Material eingebracht und auf ihre Nachweisbarkeit in Plattenversuchen geprüft. Die Schallemissionssignale wurden nach primären und sekundären Quellmechanismen getrennt und ihr Einfluss auf die Gesamtemission analysiert. T2 - 18. Kolloquium Schallemission CY - Wetzlar, Deutschland DA - 2011-10-27 KW - Schallemissionsprüfung KW - Ermüdungsrisswachstum KW - Korrosion PY - 2011 SN - 978-3-940283-37-5 IS - DGZfP-BB 131 (Vortrag 10) SP - 1 EP - 9 AN - OPUS4-24662 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nöther, N. A1 - Krebber, Katerina A1 - Schneider-Glötzl, J. T1 - An all-digital implementation of the Brillouin optical frequency domain analysis for long-range distributed strain and temperature monitoring N2 - For long-range measurements in geotechnical and industrial applications, distributed optical fiber sensors have become a tool of increasing importance throughout the past decade. Classic deformation monitoring (performed by strain gauges etc.) and temperature monitoring (Pt100 and alike) deliver data from fixed, single spots of a structure; quasidistributed measurements (fiber bragg gratings) provide a Chain of discrete measurement points along a limited sensing length. In contrast, an opticai fiber connected to a device for distributed strain and temperature sensing (DTSS) will provide a continuous profile of strain and temperature - spatially resolved down to less than 1 m - over a ränge of several tens of kilometers. In DTSS measurements, the nonlinear opticai effect of stimulated Brillouin Scattering (SBS) is employed: two light waves with a stable, tunable frequency offset are injected into opposite ends of the sensing fiber, where they will form a beat pattem, at which parts of the light will be scattered. By matching the frequency offset of the light waves to the propagation of acoustic fluctuation in the opticai fiber, a power transfer from one light wave to the other can be measured; since the acoustic propagation directly shifts with train and temperature of the fiber, these two quantities can be measured by tuning the light waves’ frequency offset. T2 - 8th International symposium on field measurements in geomechanics - FMGM 2011 CY - Berlin, Germany DA - 12.09.2011 PY - 2011 SP - 1 EP - 6 AN - OPUS4-24664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Kusche, Nadine A1 - Münzenberger, Sven A1 - Schukar, Vivien T1 - KALFOS - a validation facility for strain transfer characterization of surface-applied strain sensors N2 - Strain sensors embedded in or attached to structural components have to measure the real deformation of the structure over the whole period of use. The user must know how reliably installed sensors provide strain measurement results. For this purpose, test facilities or coupon tests are used. In order to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. This facility can be used both for fiber optic and resistance strain sensors. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (=calibration of fiber optic sensors) uses Digital Image Correlation (DIC) and Electronic Speckle Pattern Interferometer (ESPI) as unbiased referencing methods. It is possible to determine experimentally the strain transfer mechanism under combined thermal and mechanical loading conditions. This experimental characterization method will reveal weaknesses in commonly used strain sensors, and the investigation of the material systems used for fiber optic and other strain sensors (particularly the coating/substrate - adhesive combination). The KALFOS facility allows matching of specific measurement requirements with environmental conditions. T2 - SAE 2011 AeroTech Congress & Exhibition CY - Toulouse, France DA - 18.10.2011 KW - Fiber optic sensors KW - Structural health monitoring KW - Validation KW - Strain sensor KW - Surface application PY - 2011 DO - https://doi.org/10.4271/2011-01-2606 IS - Paper 2011-01-2606 SP - 1 EP - 7 AN - OPUS4-24643 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Regina A1 - Kreutzbruck, Marc A1 - Maierhofer, Christiane T1 - Numerische Verfahren für die aktive Thermografie zur Untersuchung von Rückwandgeometrien N2 - In diesem Beitrag werden numerische Verfahren zur Erkennung und Charakterisierung von Fehlstellen, Schichtdicken, Wanddicken und Inhomogenitäten mittels aktiver Thermografie vorgestellt. Eine uantitative Beurteilung der nicht immer zugänglichen Rückwand eines Bauteils (Minderdicken) ist durch Inversion thermografischer Messdaten möglich. Diese quantitativen Informationen können durch iterative Methoden vom Gauß-Newton-Typ (Inversion) gewonnen werden. Als reale Prüfobjekte werden ca. 2 cm dicke PVC-Platten mit örtlich variierender Rückwandgeometrie untersucht. Die Erwärmung erfolgt mit Blitzlampen, welche die PVC-Platte kurzzeitig um mehrere K erwärmt. Ein wichtiger Teil der Inversion ist die Simulation des Experiments, welche mit Finite-Elemente-Methoden (FEM) in 2D realisiert wird. Da Inversion und active Thermografie automatisierbar sind, bietet die Kombination breite Anwendungsgebiete innerhalb der Industrie. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Deutschland DA - 30.05.2011 KW - Inversion KW - Aktive thermografie KW - Wanddicke KW - Rückwand KW - Minderdicken KW - Schichtdicken PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-252812 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P45) SP - 1 EP - 6 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25281 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klinger, Christian A1 - Bettge, Dirk A1 - Häcker, Ralf A1 - Heckel, Thomas A1 - Gohlke, Dirk A1 - Klingbeil, Dietmar T1 - Schadensanalyse zum Radsatzwellenbruch ICE3 N2 - Am 9. Juli 2008 entgleiste ein Hochgeschwindigkeits-Triebzug der Baureihe 403, ICE3, bei der Ausfahrt aus dem Kölner Hauptbahnhof. Ursache dafür war der Schwingbruch einer Radsatzwelle. Im Auftrag der Staatsanwaltschaft Köln untersuchte die BAM die Schadensteile, insbesondere die gebrochene Treibradsatz-Hohlwelle. Zunächst wurden das Drehgestell, der Antriebsstrang, die Räder, die Bremsen und die gebrochene Radsatzwelle visuell untersucht und deren Zustand dokumentiert. Anschließend erfolgte die zerstörungsfreie Prüfung der beiden Bruchstücke der Hohlwelle mit teilmechanisierter Ultraschall-Handprüfung. Vor der Zerlegung der Radsatzwelle wurden ausgewählte Maße kontrolliert und die Oberfläche eingehend untersucht. Nach der Probenahme und Präparation wurden die relevanten spezifizierten Eigenschaften des Wellenwerkstoffs überprüft. Mittels Bruchflächenanalyse konnte die Startstelle des Schwingrisses lokalisiert, aufgrund der starken Sekundärschäden auf der Bruchfläche und an den Bruchkanten jedoch nicht direkt ausgewertet werden. Durch die Kombination von Mikro-Computertomographie und Ultraschall-Tauchtechnik wurden u. a. nahe der Schwingriss-Startstelle Inhomogenitäten erkannt, die durch metallographische Zielpräparation als nichtmetallische Einschlüsse identifiziert wurden. Die Größe dieser Einschlüsse ist gemäß gefordertem Reinheitsgrad unzulässig. Vergleichbare Einschlüsse in diesem hochbeanspruchten Bereich der Radsatzwelle haben vermutlich den Schwingriss initiiert. T2 - 43. Tagung des DVM-Arbeitskreises Bruchvorgänge - Bruchmechanische Werkstoff- und Bauteilbewertung: Beanspruchungsanalyse, Prüfmethoden und Anwendungen CY - Rostock, Germany DA - 22.02.2011 KW - Radsatzwellenbruch KW - Nichtmetallische Einschlüsse KW - Reinheitsgrad KW - Ultraschall-Hohlwellenprüfung KW - Railway axle KW - Fatigue crack KW - Root cause KW - Cologne accident PY - 2011 SP - 1 EP - 6 AN - OPUS4-25275 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völz, Uwe A1 - Mrasek, Heinz A1 - Heckel, Thomas T1 - Querfehlerprüfung an anisotropen Engspaltschweißnähten mit Gruppenstrahlern N2 - Die Prüfung von anisotropen Schweißnähten auf Querfehler stellt auch heute noch eine Herausforderung für die Ultraschallprüfung dar. Das gilt insbesondere für das Auffinden kleiner rissartiger Fehlstellen in einer unbeschliffenen Wurzel. Ursachen dafür sind zum einen das ausgeprägte Beugungs-, Streuungs- und Reflexionsverhalten solcher Nähte und zum anderen die störenden Formanzeigen aus dem Wurzelbereich, die sicher von den Fehlstellen unterschieden werden müssen, um Fehlinterpretationen bei der Bewertung der Anzeigen zu vermeiden. In der vorliegenden Arbeit werden an einer 85 mm dicken und 6 bis 10 mm breiten Engspaltschweißnaht mit stängelkristalliner Struktur rissartige Testfehler in Form erodierter Nuten untersucht. Die 2 und 4 mm tiefen Nuten sind mit 5 mm Länge kürzer als die Wurzelbreite. Die Wurzel ist nicht beschliffen und hat eine Überhöhung von ca. 2 mm. Ziel ist es, die Fehlstellen von den Form- und Gefügeanzeigen zu unterscheiden und sicher zu detektieren. Eine Größenbestimmung ist nicht vorgesehen. Durch den Einsatz der Gruppenstrahlertechnik ist es möglich, optimale Einschallparameter zu finden, mit denen diese Aufgabe gelöst werden kann. Es werden zwei azimutal schwenkende lineare Gruppenstrahlerprüfköpfe mit Vorsatzkeil in SE-Technik verwendet, die so auf beiden Seiten der Schweißnaht angeordnet sind, dass sich ihre Schallfelder unabhängig von der Einschallrichtung in der Schweißnahtwurzel überlagern. Damit ist es möglich, optimale Einschallwinkel für das Prüfproblem zu finden und in einer Prüffahrt gleichzeitig in beiden Einschallrichtungen längs der Schweißnaht zu prüfen. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Ultraschall KW - Gruppenstrhaler KW - Anisotropie KW - Austenit KW - Nickellegierung KW - Querfehler KW - Schweißnaht PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-252777 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P49) SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25277 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kitze, Jessica A1 - Boehm, Rainer A1 - Brackrock, Daniel A1 - Montag, Hans-Joachim A1 - Völz, Uwe A1 - Brekow, Gerhard A1 - Kreutzbruck, Marc T1 - SAFT-Rekonstruktion und 3D Lokalisation aus Ultraschallmessungen mit Matrix- und Linear-Arrays in Tauchtechnik N2 - Die Kombination der Synthetic Aperture Focusing Technique (SAFT) mit der Tauchtechnik stellt eine besondere Herausforderung dar. Zwei für SAFT notwendige Bedingungen – die große Schallbündeldivergenz und die Kenntnis über den Ort des Senders bzw. des Empfängers, der für die phasenrichtige Überlagerung der Echosignale genau bekannt sein muss – lassen sich einfach erfüllen, wenn kleine, fast punktförmige Sensoren direkt auf der Oberfläche des Prüfobjektes ankoppeln. Diese Anordnung ist in der Regel nicht vereinbar mit den praktischen Ansprüchen an die Signalqualität und die Flexibilität der Prüftechnik. Werden jedoch Prüfköpfe mit üblichen Abmessungen und zudem noch mit Vorlaufstrecken verwendet, dann ist die Bestimmung der Sensororte und der Schalllaufwege durch die brechende Fläche nicht mehr trivial, wenn man die für SAFT geforderte Genauigkeit in Rechnung stellt. Etwas anderes, aber ein im Prinzip einfacher Weg zur räumlichen Lokalisation von Echoquellen ist die Auswertung des 2D Sektorscans eines Matrixarrays und dessen dreidimensionale Darstellung. Durch gezielte Steuerung des Arrays gelingt auf einfache Weise die ortsrichtige Zuordnung. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Matrix-Array KW - Linear-Array KW - SAFT-Rekonstruktion in Tauchtechnik KW - Räumliche Darstellung PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-252788 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Di.3.A.2) SP - 1 EP - 11 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25278 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krebber, Katerina ED - Ramos, G. A. T1 - Structural health monitoring by smart technical textiles based on fiber optic sensors N2 - Technical textiles with embedded distributed fiber optic sensors have been developed for the purposes of structural health monitoring in geotechnical and civil engineering. The distributed fiber optic sensors are based on Brillouin Scattering in silica optical fibers and OTDR in polymer optical fibers. Such “smart” technical textiles can be used for reinforcement of geotechnical and masonry structures and the embedded fiber optic sensors can provide information about the condition of the structures and detect the presence of any damages and destructions in real time. Thus, structural health monitoring of critical geotechnical and civil infrastructures can be realized. The paper highlights the results achieved in this innovative field in the framework of several German and European projects. T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure CY - Cancún, Mexico DA - 11.12.2011 PY - 2011 IS - Keynote Lecture SP - 1 EP - 10 PB - National Autonomous University of Mexico CY - Mexico City AN - OPUS4-25261 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Schukar, Vivien ED - Ramos, G. A. T1 - Validation of strain sensors to achieve reliable measurement results N2 - Fiber optic strain sensors are increasingly used and sensor Systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor’s the performance. Therefore the contribution considers validation issues to come to reliable strain measurements and how to validate strain measurements of applied sensors. A new validation facility will be presented. T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure CY - Cancún, Mexico DA - 11.12.2011 PY - 2011 IS - Session 20, Topic 2.3 SP - 1 EP - 13 PB - National Autonomous University of Mexico CY - Mexico City AN - OPUS4-25309 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, M. A1 - Vaterrodt, K. A1 - Heidmann, G. A1 - Habel, Wolfgang A1 - Vogelsang, R. A1 - Weissenberg, W. A1 - Sekula, O. A1 - Pepper, D. A1 - Emanuel, H. A1 - Plath, R. T1 - Optical PD detection in stress cones of HV cable accessories N2 - Sensitive partial discharge (PD) measurements on HV/EHV cable systems are usually based on electrical or electromagnetic PD detection. Unfortunately, interferences may significantly reduce sensitivity, especially in on-site after-installation testing and, even more, in on-line PD monitoring. This paper deals with optical PD detection, which is absolutely immune to any kind of electromagnetic interference. Optical PD detection necessarily requires transparent or translucent insulation systems to be applicable. Stress cone elements for HV/EHV cable accessories meet the requirements for optical PD detection, if made from transparent silicone elastomers. T2 - 8th International Conference on Insulated Power Cables CY - Versailles, France DA - 19.06.2011 PY - 2011 IS - B.8.4 SP - 1 EP - 5 PB - Jicable CY - Paris AN - OPUS4-25310 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Röben, R. A1 - Hüttl, R. A1 - Kuchejda, M. ED - Ramos, G. A. T1 - Monitoring of corrosion protection in reinforced concrete structures using an integrated pH optode N2 - Corrosion in steel-reinforced concrete structures is a critical issue. Corrosion appears if the pH value of the concrete matrix decreases due to deterioration of the Calcium hydroxide layer on the Steel surface. The safest Information about potential danger of Steel corrosion is the knowledge of the pH value of concrete. The paper presents a Tiber optic pH sensor for long-term monitoring of the pH value of reinforced concrete structures at risk from corrosion. The sensor probe is small (about 8 mm in diameter), can be embedded into the concrete matrix and observe changes in pH over years. Several sensor probes can be staggered to detect the progression of pH decrease. The pH values can be resolved with 0.1 to 0.2 pH value in the ränge between 12.0 and 9.5. The structure of the pH measurement System, longterm test results and the design to achieve stable probes will be explained. Experienee from test applications of pH sensors embedded in grouted anchors and in concrete components for a cooling tower will be presented. T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure CY - Cancún, Mexico DA - 11.12.2011 PY - 2011 IS - Session 15, Topic 4.5 SP - 2 EP - 8 PB - National Autonomous University of Mexico CY - Mexico City AN - OPUS4-25311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mix, Renate A1 - Friedrich, Jörg Florian T1 - Improvement of adhesivity of polypropylene by its surface modification using the aerosol dielectric barrier discharge N2 - Plasma processes are used in many fields of Science and technology. While a plasma oxygen treatment produces a broad variety of different oxygen-containing functional groups, tailored - surface functionalisation demands preset functional groups in known concentration. Due to the fact that most of plasma experiments need expensive vacuum equipment increased efforts are to observe to apply atmospheric pressure plasma processes. Thus, Dielectric Barrier Discharge (DBD) and corona treatment of polymer foils have a long tradilion in industry to modify them for printing, laminating, adhesion promotion, etc. Thercibre, increasing interest is observed to make these atmospheric pressure processes more effeclive. Newly developed methods like plasma-printing were used for surfaces in biological and medical applications or for printed circuits. T2 - ADHESION `11 - 11th Triennial conference on the science and technology of adhesion and adhesives CY - York, UK DA - 07.09.2011 PY - 2011 SP - 253 EP - 256 AN - OPUS4-24337 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisenacher, Germar A1 - Scheidemann, Robert A1 - Neumann, Martin A1 - Wille, Frank A1 - Droste, Bernhard T1 - Approach for a finite element material model for wood for application in mechanical safety cases of transport packages N2 - BAM Federal Institute for Materials Research and Testing is the competent authority for mechanical safety assessment of transport packages for radioactive material in Germany. The further development of state-of-the-art technology concerning assessment methods is essential for a qualified work of involved designers and authority experts. The paper gives an example of current development done to improve understanding and modeling capabilities of wood filled impact limiter. In order to reduce the loads applied to the package containment, which result from regulatory drop tests, most packages are protected by energy dissipating impact limiter. Wood, encapsulated by steel sheets, is one of the materials typically used for energy dissipation in these impact limiter. Very often, mechanical safety cases regarding the 9 m drop test are performed computationally, where it is essential to use reliable and verified computational methods and models. In this context, the paper presents an approach for a finite element material model for wood. Thereby, the mechanical behavior of wood under compression loading is the focus of the development work. Additionally, material orientation as well as strain rate, temperature and lateral constraint may vary. A large number of experiments, particularly compression tests, was designed and performed to establish an adequate experimental database for modeling verification. The experimental results enabled the derivation of necessary requirements: The material model has to take into account strain rate and temperature dependencies as well as the anisotropic characteristics of the material, a proper yield criterion, flow rule and hardening law. Such a material model is currently not available in established commercial dynamic finite element codes. Thus it is necessary to create a user-defined material model considering the mentioned requirements. A first step was done by determining a yield surface as well as detecting flow and hardening mechanisms from experimental force-deflection curves. In a next step the LS-DYNA material model MAT_75 was altered according to conclusions of former BAM development work, regarding the modeling of post-peak softening as a function of lateral constraint. Future research will contain the further development, implementation and verification of a material model for wood. T2 - 52nd INMM Annual meeting CY - Palm Desert, CA, USA DA - 17.07.2011 KW - Impact limiter KW - Material model wood KW - Transport package PY - 2011 SP - 1 EP - 8 AN - OPUS4-24236 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Robertson, Daniela A1 - Böhning, Martin A1 - Schröder, Hartmut A1 - Brummermann, K. A1 - Kaudinya, I. A1 - Saathoff, F. T1 - Möglichkeiten der Abschätzung der Langzeitbeständigkeit von Kunststoffdichtungsbahnen (KDB) auf Polyolefinbasis für den Tunnelbau N2 - Im Rahmen eines von der Bundesanstalt für Straßenwesen (BASt) initiierten Forschungsvorhabens (15.449/2007/ERB: „Prüfverfahren zur Beurteilung der Lebensdauer von Kunststoffdichtungsbahnen für Straßentunnel“) wurden anhand von Untersuchungen an Kunststoffdichtungsbahnen (KDB) auf Basis von Polyolefinwerkstoffen die Möglichkeiten der Beurteilung der oxidativen Langzeitbeständigkeit sondiert. Im Mittelpunkt stand die Erprobung des Autoklaventests in Anlehnung an DIN EN ISO 13438 (Methode C1/C2) an ausgewählten, für den Tunnelbau repräsentativen marktüblichen KDB-Produkten. Die Untersuchungen im Autoklaven bei erhöhten Temperaturen (60 °C, 70 °C und 80 °C) und Sauerstoffdrücken (11, 21 und 51 bar) wurden durch vergleichende Versuche im Wärmeschrank (Ofen) bei erhöhter Temperatur (85 °C) in Anlehnung an DIN EN 14575 ergänzt. Die KDBProdukte wurden außerdem einer eingehenden Materialcharakterisierung (Zugprüfung, DMA, DSC) unterzogen. Weiterhin wurden Bauwerksdaten recherchiert und auf ihre Nutzbarkeit zur Bewertung und Prüfbarkeit der Langzeitbeständigkeit von KDB in Tunneln betrachtet. Ziel war auch, die Anwendbarkeit des bisher vorgeschlagenen Extrapolationsmodells zur Auswertung der Ergebnisse von Autoklaventests an im Tunnelbau marktüblichen Produkten für Nutzungsdauern über 25 Jahre zu überprüfen und zur Entwicklung eines geeigneten Prüfverfahrens beizutragen. Der Beitrag geht auf Ergebnisse des Vorhabens ein und zeigt erste Schlussfolgerungen und weiteren Untersuchungsbedarf auf. Die Ergebnisse werden in den „Empfehlungen zu Dichtungssystemen im Tunnelbau EAG-EDT“ des Arbeitskreises 5.1 „Kunststoffe in der Geotechnik und im Wasserbau“ berücksichtigt, deren 2. Auflage in Vorbereitung ist. Aspekte des thermischen Verhaltens der eingesetzten Werkstoffe sowie mögliche Anpassungen der Prüfrandbedingungen für die Autoklaventests werden ergänzt und Hinweise zur Interpretation von Prüfergebnissen gegeben. Außerdem wurden inzwischen ausgehend von den Ergebnissen des Forschungsvorhabens erste Autoklaven-Ringversuche in drei Prüfinstitutionen initiiert. T2 - 12. Informations- und Vortragstagung über "Kunststoffe in der Geotechnik" CY - Munich, Germany DA - 03.03.2011 KW - Kunststoffdichtungsbahnen auf Polyolefinbasis KW - Oxidative Langzeitbeständigkeit KW - Autoklaventest - beschleunigte Alterung KW - DSC KW - DMA PY - 2011 SN - 978-3-940476-26-5 IS - Geotechnik Sonderheft 2011 SP - 35 EP - 42 AN - OPUS4-24399 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Bartholmai, Matthias ED - Tsamis, C. ED - Kaltsas, G. T1 - Wireless sensor network with temperature compensated measuring technology for long-term structural health monitoring of buildings and infrastructures N2 - Damage to buildings occurs if a construction component fails. The result is a partial or total collapse which can be dangerous for people for example if it's a bridge or a large hall. The collapse of the terminal building at the Airport Charles de Gaulle in Paris and the damage at the historic City Archives of Cologne are typical examples of such accidents. Another problem is the contradiction of the increasing volume of traffic (particularly heavy traffic) and the great age of bridges. The probability increases that the load-bearing capacity of a bridge decreases. For example the collapses of the Mississippi Bridge and of the Inntal Motorway Bridge can be seen as results. Therefore it is necessary to control endangered structures during their life span. In order to prevent these kinds of accidents, the Federal Institute for Materials Research and Testing developed a radio-based, self-configuring measuring system in cooperation with the ScatterWeb Company, Berlin (Germany). This measuring system consists of identically designed sensor modules which are self-sustaining, wireless, act as transmitters and receivers and are equipped with a special sensor technology for long-term monitoring of buildings or engineering facilities. The sensor unit uses strain gauges for stress analysis and contains interfaces for additional sensors. The system in particular applies to buildings and structures for transport and traffic and large-scale industrial facilities, where a subsequent wiring installation is difficult or impossible. T2 - Eurosensors XXV CY - Athens, Greece DA - 04.09.2011 KW - Multi-Hop WSN KW - SHM KW - Temperature and Frequency Compensation KW - Funksensorik KW - Sensornetzwerk KW - Multihop KW - Strukturüberwachung KW - Temperaturkompensation PY - 2011 UR - http://www.sciencedirect.com/science/article/pii/S1877705811059236 IS - Paper 1197 SP - 1 EP - 5 PB - Elsevier AN - OPUS4-24401 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Bartholmai, Matthias A1 - Liers, A. A1 - Schiller, J. T1 - Tracking persons using a radio-based multi-sensor system N2 - A multi-sensor system for 3D localization was developed and named BodyGuard. It combines body movement sensing and a guard system for the tracking and recording of the status of persons. BodyGuard was designed to monitor and transmit the movement of a person radio-based and to transform that data into a spatial coordinate. This paper describes how the BodyGuard system works, what components the system consists of, how the individual sensor data is converted into 3D motion data, with which algorithms the individual sensors are processed, how individual errors are compensated and how the sensor data are fused into a 3D Model. T2 - IPIN 2011 - International conference on indoor positioning and indoor navigation CY - Guimaraes, Portugal DA - 21.09.2011 KW - Wireless sensor network (WSN) KW - Embedded systems KW - Sensor calibration and validation KW - Person tracking KW - Inertial navigation system KW - Inertial measurement unit PY - 2011 SP - 1 EP - 4 AN - OPUS4-24402 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Musolff, André A1 - Komann, Steffen A1 - Droste, Bernhard A1 - Müller, Karsten A1 - Quercetti, Thomas T1 - Drop test program with a HLW cask model - performance, measurements and results N2 - BAM (Federal Institute for Material Research and Testing) is the competent authority for mechanical and thermal safety assessment of transport packages for spent fuel and high level waste (HLW) in Germany. In context with package design approval of the new German HLW cask CASTOR HAW28M, BAM performed several drop tests with a half-scale model of the CASTOR HAW/TB2. The test model was manufactured by GNS (Gesellschaft fur Nuklear Service mbH) and tested under accident transport conditions on the 200 tons BAM drop test facility at the BAM Test Site Technical Safety. For this comprehensive test program the test specimen CASTOR HAW/TB2 was instrumented at 21 measurement planes with altogether 23 piezo-resistive accelerometers, five temperature sensors and 131 tri-axial strain gauges in the container interior and exterior, respectively. The strains of four representative lid bolts were recorded by four uniaxial strain gauges per each bolt. Helium leakage rate measurements were performed before and after each test in the above noted testing sequence. The paper presents some experimental results of the half-scale CASTOR HAW/TB2 prototype (14,500 kg) and measurement data logging. T2 - 52nd INMM Annual meeting CY - Palm Desert, CA, USA DA - 17.07.2011 KW - Drop test results KW - Spent fuel transport cask KW - Impact limiter KW - Measurement methods KW - Drop test program PY - 2011 SP - 1 EP - 9 AN - OPUS4-24245 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Müller, Bernd R. T1 - Correction of diffuse X-ray detector based background N2 - A novel approach to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background Signals (“backlight”) of 2D X-ray detectors is suggested. Depending on the detector geometry the mechanism may be different, either based on the optical scattering of the fluorescent screen materials into optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer’s law in single projections (radiographs). When used as input data for computed tomography these violations are directly observed via modulation of the projected mass as a function of the rotation Phase and the sample’s aspect ratio (dynamics). The magnitude of the diffuse Background signal depends on the detector area covered by the projected sample. They are more pronounced the smaller the shaded area and the stronger the total attenuation. Moreover, the local intensity mismatch depends on the attenuation of the sample. We present very basic reference data measured with multiple metal foils at a synchrotron radiation source. Beam hardening artifacts can be excluded due to the monochromatic radiation. The proposed correction procedure assumes a constant (non-local) scattering mechanism. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Backlight KW - X-ray detector KW - Fluorescence screen KW - Synchrotron radiography KW - Computed tomography PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243589 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 24) SP - 1 EP - 7 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heinze, Christoph A1 - Schwenk, Christopher A1 - Rethmeier, Michael ED - Zoch, H.-W. ED - Lübben, T. T1 - Influences on the result quality of numerical calculation of welding-induced distortion N2 - The present investigations cover different relevant influences on the numerical calculation of welding-induced distortion. Therefore, a single-layer pulsed gas metal arc (GMA) weld of structural Steel S355J2+N with a thickness Öf5 mm is experimentally and numerically investigated. The influences of mesh density, tack-welds, and continuous cooling transformation (CCT) diagrams on welding-induced distortion are studied. The quality and quantity of These effects are clarified based on the used experimental and numerical set up. The occurring differences between the investigated cases achieve significant values. Consequently, prediction of welding-induced distortion can be improved considering the present investigations. T2 - IDE 2011 - 3rd International conference on distortion engineering 2011 CY - Bremen, Germany DA - 14.09.2011 KW - Welding simulation KW - Welding-induced distortion KW - Mesh analysis KW - Tack welding KW - Continuous cooling transformation behaviour PY - 2011 SN - 978-3-88722-724-1 SP - 277 EP - 285 AN - OPUS4-24363 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Liehr, Sascha A1 - Krebber, Katerina T1 - A dynamic fiber optic strain and power change sensor N2 - A dynamic and quasi-distributed sensor principle for simultaneous measurement of length changes and optical power changes between reflection points in an optical fiber is presented. The technique is based on the incoherent optical frequency domain reflectometry (I-OFDR). Length change resolutions < 1 µm and measurement repetition rates up to 2 kHz can be achieved using standard single-mode and multi-mode optical fibers. Simultaneous length change and refractive index measurement as well as field test results showing the deformation of a masonry building under seismic load are presented. Promising fields of application for this technique are the structural health monitoring sector and chemical process control. T2 - 21st International conference on optical fibre sensors CY - Ottawa, Canada DA - 15.05.2011 KW - Distributed sensor KW - Strain sensor KW - Optical fiber sensor KW - Structural health monitoring KW - OFDR KW - Dynamic sensor PY - 2011 SN - 978-0-8194-8246-4 DO - https://doi.org/10.1117/12.884577 VL - 7753 SP - 775351-1 EP - 775351-4 AN - OPUS4-24266 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mishra, Kirti Bhushan A1 - Wehrstedt, Klaus-Dieter T1 - Burner for peroxy-fuels (PEROXY-BAM Burner) N2 - A new burner concept (PEROXY-BAM®) for the combustion of liquid organic peroxides (Peroxy-fuels) is presented. As peroxy-fuels are thermally unstable the design of burners for them should be accordingly modified ensuring a safe operation. It is found that 10 to 100 time less amounts of peroxy fuels are required for the same heat flux or output in comparison to hydrocarbons. Correspondingly, the fuel pump power and the volume of combustion chamber (furnace) are also reduced. As a result of less amount of fuel the emissions will also be stepped down and oxygen in the molecule helps to establish conditons like in an oxy-fuel combustion process. The advantages of using peroxy-fuels over hydrocarbons inside a model combustion chamber are also investigated with the help of CFD (Computational Fluid Dynamics) simulations. T2 - 25. Deutscher Flammentag - Verbrennung und Feuerung CY - Karlsruhe, Germany DA - 14.09.2011 KW - Organic peroxide KW - Peroxy-fuel KW - Burner concept KW - Combustion KW - Combustion chamber PY - 2011 SN - 978-3-18-092119-8 SN - 0083-5560 N1 - Serientitel: VDI-Berichte – Series title: VDI-Berichte VL - 2119 SP - 307 EP - 312 PB - VDI-Verl. AN - OPUS4-24388 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Gollwitzer, Christian A1 - Fratzscher, Daniel A1 - Ewert, Uwe A1 - Jaenisch, Gerd-Rüdiger T1 - Simulation of complex scan paths for 3D reconstruction N2 - X-ray computed tomography (CT) is a volumetric (3D) Imaging diagnostic method, well established in the medical field, and in industrial NDE as well. Developments in industrial CT aim to extent the applicability to complex structures, which do not allow the access of all directions. This are e.g. limited view, data and angle CT applications. New reconstruction algorithms are required on one side, and the accuracy has to be improved on the other side. Numerical Simulation can support such developments by providing well defined data sets for the testing of reconstruction algorithms. This approach of virtual CT is realized within the radiographic simulator aRTist, developed by BAM. The poster shows the possibilities of this tool to consider complex scan paths. Simulated data sets have been reconstructed by an versatile backprojection algorithm. T2 - International symposium on digital industrial radiology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Radiographie KW - Computer-Simulation KW - 3D-Rekonstruktion PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243928 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 17) SP - 1 EP - 4 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -