TY - CONF A1 - Nöther, N. A1 - Krebber, Katerina A1 - Schneider-Glötzl, J. T1 - An all-digital implementation of the Brillouin optical frequency domain analysis for long-range distributed strain and temperature monitoring T2 - 8th International symposium on field measurements in geomechanics - FMGM 2011 (Proceedings) N2 - For long-range measurements in geotechnical and industrial applications, distributed optical fiber sensors have become a tool of increasing importance throughout the past decade. Classic deformation monitoring (performed by strain gauges etc.) and temperature monitoring (Pt100 and alike) deliver data from fixed, single spots of a structure; quasidistributed measurements (fiber bragg gratings) provide a Chain of discrete measurement points along a limited sensing length. In contrast, an opticai fiber connected to a device for distributed strain and temperature sensing (DTSS) will provide a continuous profile of strain and temperature - spatially resolved down to less than 1 m - over a ränge of several tens of kilometers. In DTSS measurements, the nonlinear opticai effect of stimulated Brillouin Scattering (SBS) is employed: two light waves with a stable, tunable frequency offset are injected into opposite ends of the sensing fiber, where they will form a beat pattem, at which parts of the light will be scattered. By matching the frequency offset of the light waves to the propagation of acoustic fluctuation in the opticai fiber, a power transfer from one light wave to the other can be measured; since the acoustic propagation directly shifts with train and temperature of the fiber, these two quantities can be measured by tuning the light waves’ frequency offset. T2 - 8th International symposium on field measurements in geomechanics - FMGM 2011 CY - Berlin, Germany DA - 12.09.2011 PY - 2011 SP - 1 EP - 6 AN - OPUS4-24664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Kusche, Nadine A1 - Münzenberger, Sven A1 - Schukar, Vivien T1 - KALFOS - a validation facility for strain transfer characterization of surface-applied strain sensors T2 - SAE 2011 AeroTech Congress & Exhibition N2 - Strain sensors embedded in or attached to structural components have to measure the real deformation of the structure over the whole period of use. The user must know how reliably installed sensors provide strain measurement results. For this purpose, test facilities or coupon tests are used. In order to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. This facility can be used both for fiber optic and resistance strain sensors. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (=calibration of fiber optic sensors) uses Digital Image Correlation (DIC) and Electronic Speckle Pattern Interferometer (ESPI) as unbiased referencing methods. It is possible to determine experimentally the strain transfer mechanism under combined thermal and mechanical loading conditions. This experimental characterization method will reveal weaknesses in commonly used strain sensors, and the investigation of the material systems used for fiber optic and other strain sensors (particularly the coating/substrate - adhesive combination). The KALFOS facility allows matching of specific measurement requirements with environmental conditions. T2 - SAE 2011 AeroTech Congress & Exhibition CY - Toulouse, France DA - 18.10.2011 KW - Fiber optic sensors KW - Structural health monitoring KW - Validation KW - Strain sensor KW - Surface application PY - 2011 DO - https://doi.org/10.4271/2011-01-2606 IS - Paper 2011-01-2606 SP - 1 EP - 7 AN - OPUS4-24643 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krebber, Katerina ED - Ramos, G. A. T1 - Structural health monitoring by smart technical textiles based on fiber optic sensors T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure (Proceedings) N2 - Technical textiles with embedded distributed fiber optic sensors have been developed for the purposes of structural health monitoring in geotechnical and civil engineering. The distributed fiber optic sensors are based on Brillouin Scattering in silica optical fibers and OTDR in polymer optical fibers. Such “smart” technical textiles can be used for reinforcement of geotechnical and masonry structures and the embedded fiber optic sensors can provide information about the condition of the structures and detect the presence of any damages and destructions in real time. Thus, structural health monitoring of critical geotechnical and civil infrastructures can be realized. The paper highlights the results achieved in this innovative field in the framework of several German and European projects. T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure CY - Cancún, Mexico DA - 11.12.2011 PY - 2011 IS - Keynote Lecture SP - 1 EP - 10 PB - National Autonomous University of Mexico CY - Mexico City AN - OPUS4-25261 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Schukar, Vivien ED - Ramos, G. A. T1 - Validation of strain sensors to achieve reliable measurement results T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure (Proceedings) N2 - Fiber optic strain sensors are increasingly used and sensor Systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor’s the performance. Therefore the contribution considers validation issues to come to reliable strain measurements and how to validate strain measurements of applied sensors. A new validation facility will be presented. T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure CY - Cancún, Mexico DA - 11.12.2011 PY - 2011 IS - Session 20, Topic 2.3 SP - 1 EP - 13 PB - National Autonomous University of Mexico CY - Mexico City AN - OPUS4-25309 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, M. A1 - Vaterrodt, K. A1 - Heidmann, G. A1 - Habel, Wolfgang A1 - Vogelsang, R. A1 - Weissenberg, W. A1 - Sekula, O. A1 - Pepper, D. A1 - Emanuel, H. A1 - Plath, R. T1 - Optical PD detection in stress cones of HV cable accessories T2 - Proceedings of the 8th International Conference on Insulated Power Cables N2 - Sensitive partial discharge (PD) measurements on HV/EHV cable systems are usually based on electrical or electromagnetic PD detection. Unfortunately, interferences may significantly reduce sensitivity, especially in on-site after-installation testing and, even more, in on-line PD monitoring. This paper deals with optical PD detection, which is absolutely immune to any kind of electromagnetic interference. Optical PD detection necessarily requires transparent or translucent insulation systems to be applicable. Stress cone elements for HV/EHV cable accessories meet the requirements for optical PD detection, if made from transparent silicone elastomers. T2 - 8th International Conference on Insulated Power Cables CY - Versailles, France DA - 19.06.2011 PY - 2011 IS - B.8.4 SP - 1 EP - 5 PB - Jicable CY - Paris AN - OPUS4-25310 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Habel, Wolfgang A1 - Röben, R. A1 - Hüttl, R. A1 - Kuchejda, M. ED - Ramos, G. A. T1 - Monitoring of corrosion protection in reinforced concrete structures using an integrated pH optode T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure (Proceedings) N2 - Corrosion in steel-reinforced concrete structures is a critical issue. Corrosion appears if the pH value of the concrete matrix decreases due to deterioration of the Calcium hydroxide layer on the Steel surface. The safest Information about potential danger of Steel corrosion is the knowledge of the pH value of concrete. The paper presents a Tiber optic pH sensor for long-term monitoring of the pH value of reinforced concrete structures at risk from corrosion. The sensor probe is small (about 8 mm in diameter), can be embedded into the concrete matrix and observe changes in pH over years. Several sensor probes can be staggered to detect the progression of pH decrease. The pH values can be resolved with 0.1 to 0.2 pH value in the ränge between 12.0 and 9.5. The structure of the pH measurement System, longterm test results and the design to achieve stable probes will be explained. Experienee from test applications of pH sensors embedded in grouted anchors and in concrete components for a cooling tower will be presented. T2 - SHMII-5 - 5th International conference on structural health monitoring of intelligent infrastructure CY - Cancún, Mexico DA - 11.12.2011 PY - 2011 IS - Session 15, Topic 4.5 SP - 2 EP - 8 PB - National Autonomous University of Mexico CY - Mexico City AN - OPUS4-25311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Döhler, M. A1 - Hille, Falk A1 - Lam, X.-B. A1 - Mevel, L. A1 - Rücker, Werner ED - Proulx, T. T1 - Confidence intervals of modal parameters during progressive damage test T2 - 29th IMAC - Conference on structural dynamics (Proceedings) N2 - In Operational Modal Analysis, the modal parameters (natural frequencies, damping ratios and mode shapes) obtained from Stochastic Subspace Identification (SSI) of a structure, are afflicted with statistical uncertainty. For evaluating the quality of the obtained results it is essential to know the respective confidence intervals of these figures. In this paper we present algorithms that automatically compute the confidence intervals of modal parameters obtained from covarianceand data-driven SSI of a structure based on vibration measurements. They are applied to the monitoring of the modal parameters of a prestressed concrete highway bridge during a progressive damage test that was accomplished within the European research project IRIS. Results of the covariance- and data-driven SSI are compared. T2 - 29th IMAC - Conference on structural dynamics CY - Jacksonville, FL, USA DA - 31.01.2011 KW - Stochastische subspace basierte Identifikation KW - Schadensdetektion KW - Spannbetonbrücke PY - 2011 SN - 978-1-4419-9304-5 DO - https://doi.org/10.1007/978-1-4419-9305-2_17 SN - 2191-5644 N1 - Serientitel: Conference Proceedings of the Society for Experimental Mechanics Series – Series title: Conference Proceedings of the Society for Experimental Mechanics Series VL - 4 SP - 237 EP - 250 PB - Springer AN - OPUS4-24335 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mix, Renate A1 - Friedrich, Jörg Florian T1 - Improvement of adhesivity of polypropylene by its surface modification using the aerosol dielectric barrier discharge T2 - ADHESION `11 - 11th Triennial conference on the science and technology of adhesion and adhesives N2 - Plasma processes are used in many fields of Science and technology. While a plasma oxygen treatment produces a broad variety of different oxygen-containing functional groups, tailored - surface functionalisation demands preset functional groups in known concentration. Due to the fact that most of plasma experiments need expensive vacuum equipment increased efforts are to observe to apply atmospheric pressure plasma processes. Thus, Dielectric Barrier Discharge (DBD) and corona treatment of polymer foils have a long tradilion in industry to modify them for printing, laminating, adhesion promotion, etc. Thercibre, increasing interest is observed to make these atmospheric pressure processes more effeclive. Newly developed methods like plasma-printing were used for surfaces in biological and medical applications or for printed circuits. T2 - ADHESION `11 - 11th Triennial conference on the science and technology of adhesion and adhesives CY - York, UK DA - 07.09.2011 PY - 2011 SP - 253 EP - 256 AN - OPUS4-24337 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Eisenacher, Germar A1 - Scheidemann, Robert A1 - Neumann, Martin A1 - Wille, Frank A1 - Droste, Bernhard T1 - Approach for a finite element material model for wood for application in mechanical safety cases of transport packages T2 - 52nd INMM Annual meeting (Proceedings) N2 - BAM Federal Institute for Materials Research and Testing is the competent authority for mechanical safety assessment of transport packages for radioactive material in Germany. The further development of state-of-the-art technology concerning assessment methods is essential for a qualified work of involved designers and authority experts. The paper gives an example of current development done to improve understanding and modeling capabilities of wood filled impact limiter. In order to reduce the loads applied to the package containment, which result from regulatory drop tests, most packages are protected by energy dissipating impact limiter. Wood, encapsulated by steel sheets, is one of the materials typically used for energy dissipation in these impact limiter. Very often, mechanical safety cases regarding the 9 m drop test are performed computationally, where it is essential to use reliable and verified computational methods and models. In this context, the paper presents an approach for a finite element material model for wood. Thereby, the mechanical behavior of wood under compression loading is the focus of the development work. Additionally, material orientation as well as strain rate, temperature and lateral constraint may vary. A large number of experiments, particularly compression tests, was designed and performed to establish an adequate experimental database for modeling verification. The experimental results enabled the derivation of necessary requirements: The material model has to take into account strain rate and temperature dependencies as well as the anisotropic characteristics of the material, a proper yield criterion, flow rule and hardening law. Such a material model is currently not available in established commercial dynamic finite element codes. Thus it is necessary to create a user-defined material model considering the mentioned requirements. A first step was done by determining a yield surface as well as detecting flow and hardening mechanisms from experimental force-deflection curves. In a next step the LS-DYNA material model MAT_75 was altered according to conclusions of former BAM development work, regarding the modeling of post-peak softening as a function of lateral constraint. Future research will contain the further development, implementation and verification of a material model for wood. T2 - 52nd INMM Annual meeting CY - Palm Desert, CA, USA DA - 17.07.2011 KW - Impact limiter KW - Material model wood KW - Transport package PY - 2011 SP - 1 EP - 8 AN - OPUS4-24236 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Köppe, Enrico A1 - Bartholmai, Matthias ED - Tsamis, C. ED - Kaltsas, G. T1 - Wireless sensor network with temperature compensated measuring technology for long-term structural health monitoring of buildings and infrastructures T2 - Eurosensors XXV (Proceedings) N2 - Damage to buildings occurs if a construction component fails. The result is a partial or total collapse which can be dangerous for people for example if it's a bridge or a large hall. The collapse of the terminal building at the Airport Charles de Gaulle in Paris and the damage at the historic City Archives of Cologne are typical examples of such accidents. Another problem is the contradiction of the increasing volume of traffic (particularly heavy traffic) and the great age of bridges. The probability increases that the load-bearing capacity of a bridge decreases. For example the collapses of the Mississippi Bridge and of the Inntal Motorway Bridge can be seen as results. Therefore it is necessary to control endangered structures during their life span. In order to prevent these kinds of accidents, the Federal Institute for Materials Research and Testing developed a radio-based, self-configuring measuring system in cooperation with the ScatterWeb Company, Berlin (Germany). This measuring system consists of identically designed sensor modules which are self-sustaining, wireless, act as transmitters and receivers and are equipped with a special sensor technology for long-term monitoring of buildings or engineering facilities. The sensor unit uses strain gauges for stress analysis and contains interfaces for additional sensors. The system in particular applies to buildings and structures for transport and traffic and large-scale industrial facilities, where a subsequent wiring installation is difficult or impossible. T2 - Eurosensors XXV CY - Athens, Greece DA - 04.09.2011 KW - Multi-Hop WSN KW - SHM KW - Temperature and Frequency Compensation KW - Funksensorik KW - Sensornetzwerk KW - Multihop KW - Strukturüberwachung KW - Temperaturkompensation PY - 2011 UR - http://www.sciencedirect.com/science/article/pii/S1877705811059236 IS - Paper 1197 SP - 1 EP - 5 PB - Elsevier AN - OPUS4-24401 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -