TY - CONF A1 - Otremba, Frank A1 - Romero-Navarrete, José A. T1 - A real-time GPS scheme to assess safe driving skills N2 - Avoiding road crashes has been the purpose behind many specialized software and hardware systems, involving both active and passive safety principles. Global Positioning technologies were incorporated into the transportation systems with the main purpose of acquiring the position of the vehicle under a continuous basis, for security and economy purposes. However, the GPS data can also be used for assessing the level of safety at which the vehicle is driven. On the basis of the essential data available from commercial GPS devices, in this paper we propose a combined performance measurement to assess the road safety level at which the vehicle is being driven. Such performance measure uses GPS data of the vehicle displacement, including the speed and the acceleration, as well as the course (latitude and longitude coordinates), in an integral driving assessment formulation that can run in real time. Results from the experimental use of this formulation suggest that the level of safety in the driving is time dependent, and that there are risky situations when different factors converge. T2 - ICASAT – 2019 – IEEE international Conference on Applied Science and Advanced Technology CY - Queretaro, México DA - 27.11.2019 KW - GPS Scheme KW - Safe KW - Driving PY - 2019 AN - OPUS4-49982 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Vogl, Jochen A1 - Rienitz, O. A1 - Rosner, M. A1 - Tatzel, M. A1 - Brandt, B. A1 - Henehan, M. J. A1 - Kasemann, S. A. A1 - Kraft, R. A1 - Malinovskiy, D. A1 - Meixner, A. A1 - Noordmann, J. A1 - Rabb, S. A1 - Schüssler, J. A. A1 - Tütken, M. A1 - Vocke, R. D. T1 - Isotope ratios and delta values with minimal measurement uncertainties -measuring magnesium using MC-ICP-MS N2 - Multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) has evolved significantly since its introduction in 1992. The second and third generation instruments now allow isotope ratio measurements at unprecedented precisions, 0.001 % or better. However, precision alone is not enough for producing accurate and reliable isotope ratio measurements. Metrological considerations such as the selection of suitable calibration strategies, proper assessment of instrumental biases, and the estimation of overall measurement uncertainty remain critical to the measurement process. Properly assessed, measurement uncertainty then provides the interval within which a result can be considered both accurate and precise. All mass spectrometric measurements are affected by instrumental mass discrimination and produce isotope ratios that are biased relative to their “true” ratio. To produce accurate and traceable isotope ratio measurements, it is imperative that certified isotope reference materials (iCRMs) be used for calibration and validation purposes. iCRMs reporting absolute isotope ratios are an analyst’s first choice, particularly when its uncertainty is sufficient for the intended use. However, when smaller uncertainties are required to resolve subtle differences between samples, delta-scale measurements become important. Here, the difference between an isotope ratio measured in a sample and in an internationally accepted isotope reference material (iRM) is determined. This deviation can be positive or negative relative to the iRM, is called a delta value, and is often expressed in per mil units. This presentation will highlight the potential for MC-ICP-MS to produce isotope ratio measurements with minimal uncertainties by examining three applications involving Mg isotopes: 1) the certification of a set of iCRMs for their absolute isotope ratio using a gravimetric isotope mixture approach; 2) the comparison of these iCRMs with currently accepted Mg delta-scale reference materials through intercalibration, and 3) the determination of isotope fractionation exponents for geochemical applications. T2 - 4th International Conference on Frontiers in Mass Spectrometry CY - Kottayam, Kerala, India DA - 04.12.2019 KW - Triple isotope fractionation KW - Absolute isotope ratio KW - Delta value KW - Mangesium PY - 2019 AN - OPUS4-50004 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike T1 - Analytic of microplastics in environmental samples N2 - An overview about the existing possibilities for mircoplastic analysis is given. T2 - 2nd International Symposium on Microplastics CY - Seoul, Korea DA - 02.12.2019 KW - Harmonisation KW - Microplastics KW - TED-GC-MS PY - 2019 AN - OPUS4-50003 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike T1 - Mikroplastik als analytische Herausforderung N2 - Der Wissenstand zum Thema Mikroplastik und Harmonisierung wird dargestellt. T2 - Laborleitertreffen Futtermittelmonitoring CY - Bonn, Germany DA - 21.11.2019 KW - Hamonisierung KW - Mikroplastik KW - TED-GC-MS PY - 2019 AN - OPUS4-50001 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Petrat, T. A1 - Brunner-Schwer, C. A1 - Graf, B. A1 - Rethmeier, Michael T1 - Microstructure of Inconel 718 parts with constant mass energy input manufactured with direct energy deposition N2 - The laser-based direct energy deposition (DED) as a technology for additive manufacturing allows the production of near net shape components. Industrial applications require a stable process to ensure reproducible quality. Instabilities in the manufacturing process can lead to faulty components which do not meet the required properties. The DED process is adjusted by various parameters such as laser power, velocity, powder mass flow and spot diameter, which interact with each other. A frequently used comparative parameter in welding is the energy per unit length and is calculated from the laser power and the velocity in laser welding. The powder per unit length comparative parameter in the DED process has also be taken into account, because this filler material absorbs energy in addition to the base material. This paper deals with the influence of mass energy as a comparative parameter for determining the properties of additively manufactured parts. The same energy per unit length of 60 J/mm as well as the same powder per unit length of 7.2 mg/mm can be adjusted with different parameter sets. The energy per unit length and the powder per unit length determine the mass energy. The laser power is varied within the experiments between 400 W and 900 W. Energy per unit length and powder per unit length are kept constant by adjusting velocity and powder mass flow. Using the example of Inconel 718, experiments are carried out with the determined parameter sets. In a first step, individual tracks are produced and analyzed by means of micro section. The geometry of the tracks shows differences in height and width. In addition, the increasing laser power leads to a higher dilution of the base material. To determine the suitability of the parameters for additive manufacturing use, the individual tracks are used to build up parts with a square base area of 20x20 mm². An investigation by Archimedean principle shows a higher porosity with lower laser power. By further analysis of the micro sections, it can be seen that at low laser power, connection errors occur between the tracks. The results show that laser power, velocity and powder mass flow have to be considered in particular, because a constant mass energy can lead to different geometric as well as microscopic properties. KW - Direct energy deposition KW - Porosity KW - Inconel 718 KW - Additive manufacturing KW - Laser metal deposition PY - 2019 SN - 2351-9789 SP - 1 EP - 12 PB - Elsevier B.V. AN - OPUS4-50007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike T1 - Analytical opportunities & Challenges in (ocean) microplastics N2 - An overview about the analytical opportunities and challenges in microplastic detection is given. T2 - ISO TC61/ Annual bioplastics & ocean microplastics symposium CY - Chengdu, People's Republic of China DA - 29.09.2019 KW - Harmonisation KW - Microplastics KW - TED-GC-MS PY - 2019 AN - OPUS4-50000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schukar, Marcus A1 - Munzke, Dorit A1 - Duffner, Eric A1 - Eisermann, René A1 - Schoppa, André A1 - Szczepaniak, Mariusz A1 - Strohhäcker, J. A1 - Mair, Georg T1 - Monitoring of type IV composite pressure vessels with multilayer fully integrated optical fibre based distributed strain sensing N2 - We present the results of distributed fibre optic strain sensing for condition monitoring of a hybrid type IV composite overwrapped pressure vessel using multilayer integrated optical fibres. During load cycle tests material fatigue could be localised and monitored 17000 load cycles before burst. T2 - TAHYA Workshop "Structural health monitoring" CY - Berlin, Germany DA - 27.11.2019 KW - Distributed fibre optic sensing KW - Hybrid composite pressure vessel KW - Structural health monitoring PY - 2019 AN - OPUS4-49996 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike A1 - Bannick, C.G. T1 - Analytik von Mikroplastik - Verfahren-Ergebnisse-Harmonisierung N2 - Die zunehmenden Nachweise von Kunststoffen in verschiedenen Umweltmedien erfahren in den letzten Jahren weltweit ein zunehmendes wissenschaftliches, gesellschaftliches und politisches Interesse. Besondere Aufmerksamkeit erfahren Kunststoffpartikel von 1-1.000 µm sogenanntes Mikroplastik. Es wurde mittlerweile in Wasser, Böden, Luft und Biota nachgewiesen. Obwohl die Wirkungen auf die natürlichen Umweltfunktionen noch unklar sind und kontrovers diskutiert werden, ist allein durch die ubiquitäre Präsenz eine systematische Erfassung von Eintragsquellen und Verbleib der Partikel über alle Umweltmedien notwendig, um Maßnahmen zur Reduktion der Einträge zu veranlassen. Für eine zuverlässige Erfassung sind medienübergreifende Verfahren zu entwickeln, welche die drei analytischen Schritte, Probennahme, Probenaufbereitung und Detektion beinhalten. Die Verfahren adressieren unterschiedliche Zielgruppen, welche verschiedene analytische Informationen fordern. Für die akademische Bewertung werden Verfahren mit hohem analytischen Aufwand favorisiert, welche möglichst detaillierte Information über Partikelsorte, -größe, -zahl und -oberflächenbeschaffenheit geben. Im Gegensatz dazu, fordern Anwender aus der Praxis schnelle und einfache Monitoring Verfahren, welche die Bestimmung eines Massengehaltes, bzw. eines Grenzwertes zulassen. Allen ist gemeinsam, dass ein hoher interdisziplinärer Anspruch besteht, der sowohl technische Voraussetzungen zur repräsentativen Probennahme und die Limitationen von Detektionsverfahren berücksichtigt, als auch die Fachkompetenz von Biologen, Umweltwissenschaften, Analytiker und Polymerwissenschaftler einschließt. Verfahren zum Mikroplastiknachweis müssen auch verschieden Proben mit sehr unterschiedlichen Gehalten an natürlicher Matrix gerecht werden. So müssen allein für Wasser Verfahren entwickelt werden, die Mikroplastik verschiedener Form (sphärische Partikel, komplexe Bruchstücke, Fasern) aus Medien mit sehr variablen Partikelanteil (u.a. Trinkwasser, Oberflächenwasser, Abwasser) repräsentativ erfassen sowie schnell und kostengünstig sind – einschließlich der notwendigen Probenaufbereitung. Die jeweiligen Detektionsverfahren müssen z.B. einzelne Partikel oder integrale Gehalte über drei Dekadenklassen für thermoplastische und insbesondere auch elastomere Partikelsorten erfassen können. T2 - GDCh Wissenschaftsforum Chemie CY - Aachen, Germany DA - 15.09.2019 KW - TED-GC-MS KW - Mikroplastik KW - Analytik PY - 2019 AN - OPUS4-49995 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Braun, Ulrike T1 - Messen ist nicht alles, aber ohne Messmethoden ist alles nichts! N2 - Es wir der Wissenstand zur Analytik von Mikroplastik dargestellt, sowie die Notwendigkeit der Hamonisierung der Verfahren. T2 - Jahrestagung der deutschen Labordienstleistungsbranche CY - Gießen, Berlin DA - 05.09.2019 KW - TED-GC-MS KW - Mikroplastik KW - Analytik PY - 2019 AN - OPUS4-49994 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Unger, Jörg F. A1 - Robens-Radermacher, Annika A1 - Held, Felix A1 - Coelho Lima, Isabela T1 - Efficient reliability analysis with model reduction techniques N2 - One of the most important goals in civil engineering is to guaranty the safety of constructions. National standards prescribe a required failure probability in the order of 10-6 (e.g. DIN EN 199:2010-12). The estimation of these failure probabilities is the key point of structural reliability analysis. Generally, it is not possible to compute the failure probability analytically. Therefore, simulation-based methods as well as methods based on surrogate modelling or response surface methods have been developed. Nevertheless, these methods still require a few thousand evaluations of the structure, usually with finite element (FE) simulations, making reliability analysis computationally expensive for relevant applications. The aim of this contribution is to increase the efficiency of structural reliability analysis by using the advantages of model reduction techniques. Model reduction is a popular concept to decrease the computational effort of complex numerical simulations while maintaining a reasonable accuracy. Coupling a reduced model with an efficient variance reducing sampling algorithm significantly reduces the computational cost of the reliability analysis without a relevant loss of accuracy. T2 - MathMet2019 CY - Lisbon, Portugal DA - 20.11.2019 KW - Reliability method KW - Numerical example PY - 2019 AN - OPUS4-49989 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -