TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Round Robin test for the implementation of odour measurements regarding ISO 16000-28 into the evaluation of buildings products - Part II (Specified by VDI 4302-1) T2 - UBA-Texte N2 - While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons. KW - Odour measurement KW - Perceived intensity KW - Hedonic tone KW - VOC KW - Building materials PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/round-robin-test-for-the-implementation-of-odour SN - 1862-4804 VL - 79/2015 SP - UBA-FB 002199/E, 1-142 CY - Dessau-Roßlau AN - OPUS4-34886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung der Geruchsmessungen nach DIN ISO 16000-28 in die Bewertung von Bauprodukten T2 - UBA-Texte N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessung KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukt PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/ringversuch-zur-einfuehrung-der-geruchsmessungen SN - 1862-4804 VL - 88/2014 SP - UBA-FB 002049, EP - 1-141 CY - Dessau-Roßlau AN - OPUS4-34885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory-based evaluation of building product emissions - Integration into the Blue Angel award criteria and assessment scheme of the Committee for Health Evaluation of Building Products (UBA-FB 001500 / Förder-Kennz. 370762300) T2 - UBA-Texte N2 - Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures. These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel. The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample. For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen KW - Building product KW - Directive KW - Health care KW - Pollutant KW - Test method KW - Hydrocarbon KW - Testing using sensors KW - Emission KW - Emission test chamber KW - Odour KW - AgBB scheme KW - Health assessment KW - Assessment procedure KW - Volatile organic compounds KW - Very volatile organic compounds KW - VVOC KW - Semi volatile organic compounds KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Floor coverings KW - Coverings KW - Blue Angel KW - Odour evaluation KW - Acceptability KW - Perceived intensity KW - Hedonic KW - Reasonability KW - Standardization KW - Environmental sign KW - Volatile emission KW - Product labelling PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensory-based-evaluation-of-building-product SN - 1862-4804 IS - 61 SP - 1-133, Annex 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kasche, J. A1 - Bitter, F. A1 - Müller, D. A1 - Müller, B. T1 - Environmental and Health Provisions for Building Products - Identification and evaluation of VOC emissions and odour exposure (Research Report 202 62 320 / UBA-FB 001002) T2 - UBA-Texte N2 - In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation. KW - Building products KW - Emissions KW - Odour KW - AgBB-Scheme KW - Chamber tests KW - Interlaboratory study KW - Construction products KW - Emission test chamber KW - Odour evaluation KW - VOC KW - VVOC KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Gas sensor KW - Acrylic and silicone sealant KW - Wood-based product KW - Paints KW - Lacquers KW - Interlaboratory comparison PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/environmental-health-provisions-for-building SN - 1862-4804 SN - 0722-186X IS - 21 SP - 1 EP - 381 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-15931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Development of a Test Method for and Investigation into Limiting the Emissions from Printers and Copiers within the Framework of Assigning the Environmental Label (Research Report 201 95 311/02 / UBA-FB 00,510E) T2 - UBA-Texte N2 - Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices. KW - Emissions KW - VOC KW - Ozone KW - Dust KW - Hardcopy device KW - Printers KW - Copiers KW - Emission test chamber KW - Environmental label PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/development-of-a-test-method-for-an-investigation SN - 1862-4804 SN - 0722-186X IS - 88 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7277 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Rockstroh, Jens A1 - Wilke, Olaf A1 - Noske, Reinhard A1 - Brödner, Doris A1 - Schneider, Uwe A1 - Horn, Wolfgang T1 - Entwicklung einer Prüfmethode und Untersuchungen zur Begrenzung von Emissionen aus Druckern und Kopiergeräten im Rahmen der Umweltzeichenvergabe (Forschungsbericht 201 95 311/02 / UBA-FB 000510) T2 - UBA-Texte N2 - An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unterschiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL –UZ 62, RAL –UZ 85 sowie des neuen RAL –UZ 114 für Multifunktionsgeräte darstellt. KW - Emissionen KW - VOC KW - Ozon KW - Staub KW - Hardcopygerät KW - Drucker KW - Kopierer KW - Emissionsmesskammer KW - Umweltzeichen PY - 2003 UR - http://www.umweltbundesamt.de/publikationen/entwicklung-einer-pruefmethode-untersuchungen-zur SN - 1862-4804 SN - 0722-186X IS - 71 SP - 1 EP - 159 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-7276 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -