TY - JOUR A1 - Climent Terol, Estela A1 - Gotor, Raul A1 - Tobias, Charlie A1 - Bell, Jérémy A1 - Martin-Sanchez, Pedro A1 - Rurack, Knut T1 - Dip Sticks Embedding Molecular Beacon-Functionalized Core−Mesoporous Shell Particles for the Rapid On-Site Detection of Microbiological Fuel Contamination N2 - Microbial contamination of fuels by fungi and bacteria presents risks of corrosion and fuel system fouling. In this work, a rapid test for the determination of microbial genomic DNA from aqueous fuel extracts is presented. It combines test strips coated with polystyrene core/mesoporous silica shell particles, to the surface of which modified fluorescent molecular beacons are covalently grafted, with a smartphone detection system. In the hairpin loop, the beacons incorporate a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA gene, which is also present to a significant extent in the 18S rRNA gene of fungi, allowing for broadband microbial detection. In the developed assay, the presence of genomic DNA extracts from bacteria and fungi down to ca. 20−50 μg L−1 induced a distinct fluorescence response. The optical read-out was adapted for on-site monitoring by combining a 3D-printed case with a conventional smartphone, taking advantage of the sensitivity of contemporary complementary metal oxide semiconductor (CMOS) detectors. Such an embedded assembly allowed to detect microbial genomic DNA in aqueous extracts down to ca. 0.2−0.7 mg L−1 and presents an important step toward the on-site uncovering of fuel contamination in a rapid and simple fashion. KW - Bacteria KW - Fungi KW - Rapid test KW - Fluorescence KW - Smartphone KW - Biofouling PY - 2020 DO - https://doi.org/10.1021/acssensors.0c01178 SN - 2379-3694 VL - 6 IS - 1 SP - 27 EP - 34 PB - American Chemical Society CY - Washington, DC AN - OPUS4-51956 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tobias, Charlie A1 - Climent Terol, Estela A1 - Gawlitza, Kornelia A1 - Rurack, Knut T1 - Polystyrene Microparticles with Convergently Grown Mesoporous Silica Shells as a Promising Tool for Multiplexed Bioanalytical Assays N2 - Functional core/shell particles are highly sought after in analytical chemistry, especially in methods suitable for single-particle analysis such as flow cytometry because they allow for facile multiplexed detection of several analytes in a single run. Aiming to develop a powerful bead platform of which the core particle can be doped in a straightforward manner while the shell offers the highest possible sensitivity when functionalized with (bio)chemical binders, polystyrene particles were coated with different kinds of mesoporous silica shells in a convergent growth approach. Mesoporous shells allow us to obtain distinctly higher surface areas in comparison with conventional nonporous shells. While assessing the potential of narrow- as well as wide-pore silicas such as Mobil composition of matter no. 41 (MCM-41) and Santa Barbara amorphous material no. 15 (SBA-15), especially the synthesis of the latter shells that are much more suitable for biomolecule anchoring was optimized by altering the pH and both, the amount and type of the mediator salt. Our studies showed that the best performing material resulted from a synthesis using neutral conditions and MgSO4 as an ionic mediator. The analytical potential of the particles was investigated in flow cytometric DNA assays after their respective functionalization for individual and multiplexed detection of short oligonucleotide strands. These experiments revealed that a two-step modification of the silica surface with amino silane and succinic anhydride prior to coupling of an amino-terminated capture DNA (c-DNA) strand is superior to coupling carboxylic acid-terminated c-DNA to aminated core/shell particles, yielding limits of detection (LOD) down to 5 pM for a hybridization assay, using labeled complementary single-stranded target DNA (t-DNA) 15mers. The potential of the use of the particles in multiplexed analysis was shown with the aid of dye-doped core particles carrying a respective SBA-15 shell. Characteristic genomic sequences of human papillomaviruses (HPV) were chosen as the t-DNA analytes here, since their high relevance as carcinogens and the high number of different pathogens is a relevant model case. The title particles showed a promising performance and allowed us to unequivocally detect the different high- and low-risk HPV types in a single experimental run. KW - Bead-based assay KW - Core-shell particles KW - Human papillomavirus KW - Mesoporous silica KW - Multiplexing PY - 2020 DO - https://doi.org/10.1021/acsami.0c17940 SN - 1944-8244 VL - 13 IS - 1 SP - 207 EP - 218 PB - American Chemical Society CY - Washington, DC AN - OPUS4-51955 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Climent Terol, Estela A1 - Biyikal, Mustafa A1 - Gröninger, Delia A1 - Weller, Michael G. A1 - Martínez Mánez, R. A1 - Rurack, Knut ED - Climent Terol, Estela T1 - Multiplexed Detection of Analytes on Single Test Strips with Antibody-Gated Indicator-Releasing Mesoporous Nanoparticles N2 - Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed. KW - Multiplexing KW - Explosives detection KW - Gated materials KW - Fluorescence PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-518424 DO - https://doi.org/10.1002/anie.202009000 SN - 1433-7851 SN - 1521-3773 VL - 59 IS - 52 SP - 23862 EP - 23869 PB - Wiley-VCH CY - Weinheim AN - OPUS4-51842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Costa, Elena A1 - Climent Terol, Estela A1 - Gawlitza, Kornelia A1 - Wan, Wei A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Optimization of analytical assay performance of antibody-gated indicator-releasing mesoporous silica particles N2 - Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities. KW - Antibody-gated indicator delivery KW - Lateral flow assay KW - SBA-15 KW - SBA-16 KW - Type-I pyrethroids KW - Phenothrin KW - Permethrin KW - Etofenprox KW - Amplification KW - Biosensors KW - Immunoassays KW - Mesoporous particles KW - Optical detection PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517053 DO - https://doi.org/10.1039/d0tb00371a VL - 8 IS - 22 SP - 4950 EP - 4961 PB - Royal Society of Chemistry AN - OPUS4-51705 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela T1 - Design and synthesis of lateral flow tests containing antibody-gated materials N2 - Methods for the rapid and sensitive detection of target analytes are gaining importance in medical diagnostics and environmental monitoring, in the security, occupational health and safety as well as food sectors. Among all the methods employed for rapid tests, lateral flow assays (LFAs) are the most commonly used. However, some drawbacks are that most of these tests either indicate the analyte only indirectly, and in other cases the sensitivity is not high enough. Keeping in mind these limitations, the use of stimuli-responsive materials for small-molecule sensing relying on chemical signal amplification and utilizing specific interactions between biomolecules such as antibodies and the corresponding analytes are particularly attractive. Such materials can also be incorporated on paper strips for lateral-flow assays in a straightforward manner. These sensing materials comprise mesoporous silica nanoparticles loaded with indicator molecules and containing certain hapten derivative molecules covalently grafted at the surface, which bind to the respective antibody and inhibit the release of a dye as reporter (Scheme 1). In presence of the designated analyte, a displacement of the antibody from the material is observed, allowing the release of dye. Because a large number of indicator molecules can be released when a single analyte molecule binds to an antibody cap, a strong signal amplification is observed. Considering the modularity, high sensitivity and selectivity of these antibody-gated indicator delivery systems, the presentation discusses general aspects of system design as well as analytical performance and highlights the integration into a lateral-flow assay, showing as an example the determination of the explosives TATP, TNT and PETN with a fluorescence readout, in single-substance and multiplexing modes. T2 - International Webinar on Biosensors and Bioelectronics CY - Online meeting DA - 20.07.2020 KW - Multiplexing detection KW - Rapid testing methods KW - Gated hybrid materials KW - Lateral flow tests KW - Explosives detection PY - 2020 UR - https://europeanmeetings.net/conferences/biosensor-bioelectronics AN - OPUS4-51038 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Costa, Elena A1 - Climent Terol, Estela A1 - Ast, S. A1 - Weller, Michael G. A1 - Canning, J. A1 - Rurack, Knut T1 - Development of a lateral flow test for rapid pyrethroid detection using antibody-gated indicator-releasing hybrid materials N2 - The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use. Antibody-gated indicator-releasing materials were thus developed and implemented with test strips for lateral-flow assay-based analysis employing a smartphone for readout. Besides a proper matching of pore sizes and gating macromolecules, the functionalization of both the material's outer surface as well as the strips with PEG chains enhanced system performance. This simple assay allowed for the detection of permethrin as a target molecule at concentrations down to the lower ppb level in less than 5 minutes. KW - Lateral flow test KW - Gated hybrid material KW - Fluorescence KW - Smartphone readout device KW - Pyrethroid KW - Pesticide KW - Insecticide KW - SBA-15 KW - Permethrin PY - 2020 DO - https://doi.org/10.1039/d0an00319k SN - 0003-2654 SN - 1364-5528 VL - 145 IS - 10 SP - 3490 EP - 3494 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-50756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Costa, Elena A1 - Gawlitza, Kornelia A1 - Wan, Wei A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Antibody-gated indicator releasing mesoporous materials: a potential biosensor platform to be used in the development of rapid tests N2 - The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min. With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4] T2 - Biosensors for Pandemics CY - Online conference DA - 06.05.2020 KW - Hybrid materials KW - Pyrethroids KW - Signal amplification PY - 2020 UR - http://www.confstreaming.com/Biosensors2020/ AN - OPUS4-50746 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Costa, Elena A1 - Gawlitza, Kornelia A1 - Wan, Wei A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Antibody-gated indicator releasing mesoporous materials: a potential biosensor platform to be used in the development of rapid tests N2 - The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min. With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4] T2 - Biosensors for Pandemics CY - Online conference DA - 06.05.2020 KW - Hybrid materials KW - Pyrethroids KW - Signal amplification PY - 2020 UR - http://www.confstreaming.com/Biosensors2020/ AN - OPUS4-50744 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -