TY - CONF A1 - Palásti, David J. A1 - Himics, L. A1 - Vaczi, T. A1 - Veres, M. A1 - Gornushkin, Igor B. A1 - Galbacs, G. T1 - Optical modelling of spectroscopiccharacteristics of a dual-grating tunablespatial heterodyne LIBS spectrometer N2 - The spatial heterodyne spectrometer (SHS) concept, which is based on an interferometricoptical setup, boasts both the Fellgett and Jacquinot advantages. Theoretically it can provideboosted sensitivity and spectral resolution with respect to dispersion spectrometers in acompact, reasonably cheap arrangement without any moving components – this set ofcharacteristics can be attractive to a number of industrial, space and other field applications. The potential of SHS has already been demonstrated in IR and Raman spectroscopies(e.g.), and more recently also in LIBS. The scientific goal of our present project is toapply the SHS concept to the development of an optimized, but practical dual-grating,tunable SH-LIBS setup, which would possess appealing spectroscopic characteristics.During this development, we extensively rely on the computer-based simulation of theoptical setup, which is an efficient approach that we found to have been missing from earlierSHS efforts published. It can provide application-specific optimization of the SHS systemand predict the performance of the final system. In particular, we use optical simulation tostudy the effect of various important parameters on the relevant spectroscopic figures ofmerits of the system. We used the non-sequential ray-tracing mode of the Zemax/OpticStudio software for optical modelling of the SH-LIBS setup (Optical distortions were studiedin sequential mode). Characteristics of the setup and interferograms were calculated with atleast one million rays. All calculations were carried out for the visible spectral range(400-700 nm), using stepwise extension of monochromatic simulations with 5 nm steps.Wherever applicable, characteristic discrete visible wavelengths from the emissionspectrum of Hg discharge lamps (404.7 nm, 435.8 nm, 546.1 nm, 579.0 nm) were used for thecalculation of spectroscopy figures of merit and for the validation of simulation. T2 - 10th Euro-Mediterranean Symposium on Laser-Induced Breakdown Spectroscopy CY - Brno, Czech Republic DA - 08.09.2019 KW - Spatial Heterodyne Spectroscopy KW - Laser induced plasma KW - Plasma modeling KW - Plasma diagnostics KW - LIBS KW - Modeling PY - 2019 AN - OPUS4-49772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kepes, E. A1 - Gornushkin, Igor B. A1 - Porizka, P. A1 - Kaiser, J. T1 - Tomography of asymmetrical laser-induced plasmas N2 - Asymmetrical laser-induced plasmas were investigated by a tomography approach based onthe inverse Radon transform. Two distinct sources of asymmetricity were investigated:double-pulsed laser-induced plasmas in the orthogonal configuration and single-pulsedlaser-induced plasmas under an inclined incidence angle. Both cases were observed atvarious delay times. The optical thinness of the laser-induced plasmas was achieved byappropriately adjusting the pulse energies. High temporal resolution was achieved by agated intensified charge-coupled-device camera. The asymmetrical laser-induced plasmaswere investigated in terms of their total emissivity, spectrally resolved emissivity, andtemperature. The latter was obtained by the Saha–Boltzmann plot method. The imagesrequired for the inverse Radon transform technique were obtained with a high angularaccuracy and reproducibility provided by mounting the spectrometer on a high-precisionnano-positioning rotary stage. The plasmas were induced in the center of rotation of thestage. This arrangement enabled the reconstruction of emissivity which was integrated overthe full spectral range (200–800 nm) or over a desired spectral range selected by a bandpassfilter (~10 nm). It also allowed for the reconstruction of spectrally-resolved emissivity ineach cross-sectional plasma slice by scanning the plasma across a spectrometer slit. The 3Dmaps of the temperature and electron density were thus obtained for different types ofasymmetric plasmas. The work will provide a more detailed description of the twoasymmetrical laser-induced plasmas. This might help with the development of LIBSinstrumentation using the orthogonal double-pulse geometry, or remote LIBS applicationswhich inherently rely on inclined-angle ablation. T2 - 10th Euro-Mediterranean Symposium on Laser-Induced Breakdown Spectroscopy CY - Brno, Czech Republic DA - 08.09.2019 KW - LIBS KW - Laser induced plasma KW - Plasma modeling KW - Plasma diagnostics PY - 2019 AN - OPUS4-49771 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Xue, Boyang A1 - Riedel, Jens A1 - Gornushkin, Igor B. A1 - Zheng, Ronger A1 - You, Yi T1 - Ultrasound-Assisted Underwater Laser-induced Breakdown Spectroscopy with HighRepetition-Rate μJ-DPSS laser N2 - The elemental analysis of seawater is often critical to the understanding of marinechemistry, marine geochemistry, and the deep-sea ecosystems. Laser-induced breakdownspectroscopy (LIBS) with the advantage of rapid multi-elements detection, has a greatpotential for in-situ elemental analysis of seawater. In practice, it is crucial to create acompact, low cost and power saving instrument for the long-term deep-sea observation. Arecently appeared diode-pumped solid-state (DPSS) laser seems to be a promising candidateas it is both compact and robust. Additionally, its high repetition rate up to hundreds of kHzcan provide a considerable throughput for LIBS analysis. However, the DPSS lasers operateat moderate pulse energies, usually less than one mJ, which cannot sustain stablebreakdowns in bulk water. To ensure stable laser-induced plasmas underwater with such aμJ-DPSS laser, we introduced an ultrasound source to assist the breakdown process. Thephase interface and mass flow generated by the near-field ultrasound can greatly reduce thebreakdown threshold and enhance element-specific emissions. Meanwhile, the highrepetition-rate pulses can also improve the breakdown probability and generate uniqueemission lines originated from the water molecule. We further demonstrate that the highrepetition-rate DPSS laser combined with the Echelle spectrometer can provide effectivequantitative analysis for metal elements in bulk water. T2 - 10th Euro-Mediterranean Symposium on Laser-Induced Breakdown Spectroscopy CY - Brno, Czech Republic DA - 08.09.2019 KW - LIBS KW - Laser induced plasma KW - Plasma modeling KW - Plasma diagnostics KW - Underwater LIBS PY - 2019 AN - OPUS4-49769 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völker, Tobias A1 - Millar, Steven A1 - Strangfeld, Christoph A1 - Wilsch, Gerd T1 - Classification of cement pastes with laser-induced breakdown spectroscopy N2 - In civil engineering, the investigation of existing infrastructure is of major importance for maintaining and ensuring stability of the structures. To ensure durability, uniform regulations and standards apply e.g. the European standard EN 206-1. In some countries, the EN-standard is supplemented by additional standards, as in Germany with DIN 1045-2. Here, specific application rules are described, e.g. for the cement type, to ensure the resistant to different exposures. Therefore, the knowledge of the materials originally used is important in assessing the condition of existing concrete structure. Unfortunately, these are often unknown and must be determined retrospectively. Therefore, we present the application of the laser-induced breakdown spectroscopy to distinguish between different types of cement. Spectral information’s are used to build a classification model. First, the accuracy of the classification is analyzed on ten pure laboratory cement samples. To investigate possible sources of error, the model was then applied to cement samples with different moisture content. The study shows that LIBS is a promising tool for distinguishing between cement types. For further industrial application, however, factors influencing the LIBS signal must be included to ensure a robust model. T2 - 10th Euro-Mediterranean Symposium on Laser-Induced Breakdown Spectroscopy CY - Brno, Czech Republic DA - 08.09.2019 KW - Spectroscopy KW - LIBS KW - Cement KW - Classification PY - 2019 AN - OPUS4-49253 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Torge, Manfred A1 - Seneschal-Merz, Karine A1 - Günther, Tobias A1 - Wilsch, Gerd T1 - Determination of boron in 19th and 20th century paint layers using LIBS N2 - 19th and 20th centuries glass paint layers consist of a colour body and a colourless lead silicate flux, in which borax or boric acid was added as further component to improve the paint ability and to reduce the firing temperature for multiple layers of paint. Model glasses were used in laboratory tests to investigate the stability of glass paints with additions of boron oxide. To determine boron in paint layers, a LIBS-system with pulsed NdYAG-laser was used. T2 - Technart 2019 CY - Brugge, Belgien DA - 07.05.2019 KW - Stained glass windows KW - Glass paints KW - LIBS PY - 2019 AN - OPUS4-48229 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gornushkin, Igor B. A1 - Palásti, David J. A1 - Veres, M. A1 - Rigó, I. A1 - Geretovszky, Z. A1 - Kovács-Széles, É. A1 - Gojani, Ardian A1 - Galbács, Gábor T1 - Optimization and detailed spectroscopic characterization of an improved SH-LIBS setup N2 - The spatial heterodyne detection principle has a great potential in spectroscopy. It has an optical setup similar to that of a Michelson interferometer, with the mirrors replaced by diffraction gratings positioned at fixed, equal distances from the beamsplitter and are slightly tilted. The resulting interference pattern is recorded by a digital camera and the spectrum is recovered by using Fourier transformation. Although SHS was initially developed for astronomical and satellite-based atmospheric measurements, but in recent years it has been started to be applied in other branches of spectroscopy too. Recently the area of laser-induced breakdown spectroscopy (LIBS) has also discovered the potential of SHS. The main appeal of SHS detection in LIBS includes the compactness and robustness of the setup (in view of field applications) and the flexibility to optimize the setup for either high sensitivity or for high resolution, which can be benficially exploited in applications like stand-off measurements, quantitative analysis with isotope resolution, etc. In the present work, we have improved and further optimized our initial LIBS-SHS setup described in a previous conference. By using optical simulations, we have modelled the light transmission efficiency, instrumental function and imaging properties of the system. We significantly improved and automated the spectral and image data processing sequence. The optimizations carried out resulted in an improved spectral resolution and repeatability, a lower spectral background and the elimination of the central line artifact originating from the Fourier transformation procedure. A detailed characterization of the LIBS spectroscopy performance (e.g. resolution, spectral coverage, tuning range, linearity, etc.), including a comparison with that of a LIBS setup based on a conventional dispersion CCD spectrometer was also performed. T2 - European Winter Conference on Plasma Spectrochemistry (EWSPS-2019) CY - Pau, France DA - 03.02.2019 KW - SHS KW - Laser induced plasma KW - LIBS KW - Plasma modeling KW - Spatial heterodyne spectrometer PY - 2019 AN - OPUS4-48047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Chao, Madlen A1 - Büchele, Dominique A1 - Ostermann, Markus T1 - Influence of moisture and grain sizes on the analysis of nutrients in German agricultural soils using DP-LIBS N2 - Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field. The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration. The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils. T2 - Anakon 2019 CY - Münster, Germany DA - 25.03.2019 KW - LIBS KW - Soil KW - PCA KW - PLSR PY - 2019 AN - OPUS4-47655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Chao, Madlen A1 - Büchele, Dominique A1 - Ostermann, Markus T1 - Influence of moisture and grain sizes on the analysis of nutrients in German agricultural soils using DP-LIBS N2 - Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field. The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration. The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils. T2 - 13. Interdisziplinäres Doktorandenseminar Ak PAT CY - Berlin, Germany DA - 18.03.2019 KW - LIBS KW - Soil KW - PCA KW - PLSR KW - Moisture KW - Grain size PY - 2019 AN - OPUS4-47654 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Chao, Madlen A1 - Büchele, Dominique A1 - Ostermann, Markus T1 - Influence of moisture and grain sizes on the analysis of nutrients in German agricultural soils using DP-LIBS N2 - Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field. The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration. The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils. T2 - BonaRes Statusseminar CY - Leipzig, Germany DA - 19.02.2019 KW - LIBS KW - Soil KW - PCA KW - PLSR KW - Moisture KW - Grain size PY - 2019 AN - OPUS4-47651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -