TY - GEN A1 - Kautek, Wolfgang A1 - Pentzien, Simone A1 - Rudolph, Pascale A1 - Krüger, Jörg A1 - Maywald-Pitellos, C. A1 - Bansa, H. A1 - Grösswang, H. A1 - König, W. ED - Fotakis, C. T1 - Near-Ultraviolet Pulsed Laser Interaction with Contaminants and Pigments on Parchment: Spectroscopic Diagnostics for Laser Cleaning Safety T2 - 5th International Conference on Optics within Life Sciences CY - H¯erakleion, Greece DA - 1998-01-01 PY - 2000 SN - 3-540-66648-6 N1 - Serientitel: Optics within life sciences – Series title: Optics within life sciences IS - 5 SP - 100 EP - 107 PB - Springer CY - Berlin AN - OPUS4-6189 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stadthaus, Meinhard A1 - Thomas, Hans-Martin A1 - König, W. A1 - Baugatz, J. A1 - Migoun, N. A1 - Gnusin, A. T1 - Ermittlung der Eignung von Prüfmitteln für die Eindring- und Magnetpulverprüfung nach dem europäischen Normwerk T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2001 CY - Berlin, Deutschland DA - 2001-05-21 PY - 2001 UR - http://www.ndt.net/article/dgzfp01/papers/p39/p39.htm N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 75-CD PB - DGZfP CY - Berlin AN - OPUS4-1302 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Stadthaus, Meinhard A1 - Thomas, Hans-Martin A1 - Baugatz, J. A1 - König, W. A1 - Migoun, N. A1 - Gnusin, A. T1 - Performance testing of detection media for magnetic particle and penetrant testing following the European standards T2 - Congrès COFREND 2001 CY - Reims, France DA - 2001-04-24 PY - 2001 SP - 1(?) EP - 6(?) PB - COFREND CY - Paris AN - OPUS4-1123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thomas, Hans-Martin A1 - Stadthaus, Meinhard A1 - Baugatz, J. A1 - König, W. A1 - Migoun, N. P. A1 - Prokhorenko, P. P. A1 - Gnusin, A. B. T1 - Reproducibility Problem for the Procedure of Type Testing of Liquid Penetrants N2 - Apparently that the type testing procedure should be conducted under the conditions ensuring reproducibility of its outcomes. We investigated various factors effecting upon the reproducibility. To obtain quantitative characteristics of indication’s visibility the image-processing hard-and software were used. It was established that there are two main groups of these factors. The first depends on the differences between various test panels, which are used for type testing. The second one concerns the reproducibility of some stages of penetrant testing procedure (excess penetrant removing and developer application). The recommendations to increase the reproducibility of type testing are developed and illustrated experimentally. The determination of penetrant system sensitivity as a part of type testing should be conducted ensuring reproducibility of the result. We investigated some factors effecting the reproducibility. To obtain quantitative characteristics of indication’s visibility, an image processing system was used [1]. We used 3 different sets of reference blocks (rb1, rb2, rb3) corresponding to type 1 of EN ISO 3452-3 [2]. Two fluorescent penetrants with different sensitivities and the same wet solvent developer were used. It was established that the reproducibility of type testing is influenced by mainly two principal factors. First there are the differences between reference blocks. Second one concerns the reproducibility of penetrant testing procedure, especially excess penetrant removal and developer application. According to EN ISO 3452-3 a reference block for determination of sensitivity level of fluorescent penetrants consists of a set of three nickel-chrome plated panels with 10, 20 and 30 µm plating thickness. Transverse cracks are made in each panel by stretching the panels in the longitudinal direction and width to depth ratio of the cracks should be approximately 1/20. Each panel presents a certain sensitivity level, which is characterised by the level of visibility of the indication. The highest level 3 corresponds to the panel with 10 µm thickness plating. Each panel is cut longitudinally (perpendicular to the crack) so that 2 sheets (panels A and B) with nearly the same cracks will be produced. These panels A and B of a reference block are used for relative evaluation, for example to compare sensitivities of two penetrants. It is considered that the application of the same penetrant to both panels with subsequent adequate development results in the same visibility of the indications on these panels. Quantitative correlations between the abilities of the reference blocks used for determining of the sensitivity were obtained in our investigations. We used the relations between the measured values of light-fluxes from the indications of similar comparing areas on two panels. These indications correspond to certain cracks’ parts of the same total length on both comparing areas. The relations of the steps between the panel are responsible for the definition of the sensitivity groups. From our investigations it follows that the steps of the different sets are different. Besides it was established that the indication‘s visibility for the same penetrant applied on different reference blocks might have a considerable difference depending on the penetrant sensitivity: the higher penetrant’ sensitivity, the smaller is such a difference between the steps 30/20 and 20/10. For example, for rb3 the relations 30/20 and 20/10 for lower sensitive penetrant (I1) reached factor 3 comparing with factor 2 for higher sensitive penetrant (I2). Some results of the comparison between the 3 sets (rb1, rb2, rb3) investigations are summarised in Table 1 with rb1 as a reference. T2 - 8th ECNDT CY - Barcelona, Spain DA - 2002-06-17 PY - 2002 UR - http://www.ndt.net/article/ecndt02/199/199.htm VL - 8 SP - 1(?) EP - 5(?) PB - European Federation for Non-Destructive Testing CY - Barcelona AN - OPUS4-1396 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stadthaus, Meinhard A1 - Thomas, Hans-Martin A1 - Migoun, N.P. A1 - Gnusin, A.B. A1 - Baugatz, J. A1 - König, W. T1 - Sensitivity of penetrant and magnetic particle testing - Performance testing of detection media for penetrant and magnetic particle testing (PT and MT) N2 - Die Empfindlichkeit von Eindring- und Magnetpulverprüfungen (PT, MT) hängt unter anderem von der Eignung und der Qualität der Prüfmittel ab (für PT bezeichnet als Eindringsystem). Die Ermittlung der Empfindlichkeit erfolgt an Kontrollkörpern mit natürlichen und künstlichen Inhomogenitäten durch Ermittlung der Anzeigenerkennbarkeit als Maß für die Eignung. Die europäischen Normen spezifizieren die Anforderungen an die Prüfmittel für Typen-, Chargen- und Betriebsprüfungen nach pr EN ISO 3452-2 für PT und EN ISO 9934-2 für MT. Dieser Beitrag beschreibt die Ermittlung der Empfindlichkeit von Prüfmitteln sowie deren Qualifizierung bei der Typenprüfung. Die vorgeschlagenen Verfahren wurden durch experimentelle Untersuchungen validiert, bei denen ein Bildverarbeitungssystem zur Ermittlung der Anzeigenerkennbarkeit verwendet wurde. Im Hinblick auf die Qualifizierung der Prüfmittel wird die Zuverlässigkeit der Verfahren diskutiert. PY - 2004 U6 - https://doi.org/10.3139/120.100591 SN - 0025-5300 VL - 46 IS - 6 SP - 320 EP - 326 PB - Carl Hanser Verlag CY - München AN - OPUS4-3574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -