TY - CONF A1 - Schroeder, H. A1 - Müller, Urs A1 - Ziegert, C. T1 - Buildingcodes and standards in earth building - current situation in Germany T2 - Earth USA 2011 - 6th International earthbuidling conference (Proceedings) T2 - Earth USA 2011 - 6th International earthbuidling conference CY - Albuquerque, NM, USA DA - 2011-09-30 KW - Lehmbau KW - Normen KW - Bauprodukte PY - 2011 SN - 978-0-9824660-2-5 SP - 140 EP - 148 AN - OPUS4-25646 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Neuschaefer-Rube, U. A1 - Bartscher, M. A1 - Neugebauer, M. A1 - Härtig, F. A1 - Goebbels, Jürgen A1 - Ehrig, Karsten A1 - Staude, Andreas T1 - Measurement of micro gears - comparison of optical, tactile-optical and CT-measurements T2 - Proceedings of SPIE 7864 N2 - Micro gears are applied in an increasing quantity in many applications. Therefore, precise measurements are of growing importance to ensure their quality. This contribution describes the measurement of gears of a micro planetary gear set with a tactile probe, a tactile-optical probe, an optical sensor, and computed tomography (CT). For the tactile measurements, a high precision piezoresistive microprobe was used. A so-called fiber probe was applied for tactile-optical measurements. This probe applies image processing to determine the position of the tactile probing element. For all tactile and tactile-optical measurements, single point probing was used. The optical measurements were carried out with an imaging sensor based on focus variation. Due to limited accessibility, on some gears not all regions could be measured by the optical sensor and the tactile-optical probe. In contrast to this, with CT the whole part could be measured with high point density. We used a micro-CT system and carried out measurements with Synchrotron-CT. All the sensors used deliver measurement data in Cartesian coordinates. It is a challenge to transfer these data into coordinates in which gear parameters are defined. For this, special attention must be paid to the determination of the gear axis and to the orientation of the teeth. The applied procedures are detailed for different micro gears. The comparison between data of different measurements was carried out successfully. The deviations between the CT data and the tactile or tactile-optical data lie in the range of only a few micrometers. KW - Micro gears KW - Coordinate metrology KW - Computed tomography KW - Optical sensors KW - Tactile probes PY - 2011 DO - https://doi.org/10.1117/12.872413 SN - 0277-786X SN - 0038-7355 SN - 0361-0748 N1 - Serientitel: Proceedings series – Series title: Proceedings series IS - 7864 SP - 78640H-1 EP - 78640H-9 PB - VDE-Verl. CY - Berlin ; Offenbach AN - OPUS4-25998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pfennig, Anja A1 - Linke, B. A1 - Schulze, S. A1 - Kranzmann, Axel T1 - Corrosion in pipe steels exposed to supercritical CO2 during carbon capture and storage CCS T2 - EUROCORR 2011 - Developing solutions for the global challenge N2 - The CCS technique involves the compression of emission gasses in deep geological layers. To guarantee the safety of the site, CO2-corrosion of the injection pipe steels has to be given special attention when engineering CCS-sites. To get to know the corrosion behaviour samples of the heat treated steel 1.72252CrMo4, used for casing, and the stainless injection-pipe steel 1.4034 X46Cr13 were kept at T=60 °C and ambient pressure as well as p=100 bar for 700 h - 8000 h in a CC 2-saturated synthetic aquifer environment similar to possible geological on-shore CCS-sites in the northern German Basin. The isothermal corrosion behaviour obtained by mass gain of the steels in the gas phase, the liquid phase and the intermediate phase gives surface corrosion rates around 0.1 to 0.8 mm/year at ambient pressure and much lower about 0.02 to 0.2 mm/year at 100 bar where the CO 2 is in its supercritical state. Severe pit corrosion with pit heights around 4.5 mm are only located on the 42CrMo4 steel. Main phase of the continuous complicated multi-layered carbonate/oxide structure is siderite FeCO 3 in both types of steel. T2 - EUROCORR 2011 - Developing solutions for the global challenge CY - Stockholm, Sweden DA - 04.09.2011 KW - Steel KW - Pipeline KW - Corrosion KW - Carbonate layer KW - CCS KW - CO2-storage PY - 2011 SP - Paper 1044-1 EP - Paper 1044-8 AN - OPUS4-28008 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pfennig, Anja A1 - Linke, B. A1 - Schulze, S. A1 - Kranzmann, Axel T1 - Static and dynamic long term corrosion experiments in CCS-conditions T2 - EUROCORR 2011 - Developing solutions for the global challenge N2 - Dealing with first corrosion screening experiments to predict the reliability and safety of Germanys first Carbon Capture and Storage site in the northern Bassin of Germany, northwest of the Capital Berlin, laboratory experiments have been established to simulate the particular conditions at T=60 °C, highly saline aquifer water similar to 'Stuttgart Aquifer', but only at ambient pressure. With mounting 2 independent full 2-grade titanium autoclave systems (running up to 250 bar and 300 °C) pressures up to p=100 bar are possible. In 2010 a specific corrosion chamber of 2-grade titanium working up to 100 °C, flowing aqui fer water with different gas mixtures was designed to fit to a high cycle fatigue testing machine. Long term fatigue experiments simulating fatigue crack growth under corrosive environments will soon start. These experiments may not only help engineering a CCS site, but results can be used to improve the maintenance of geothermal energy production sites, especially moved parts such as pumps and shafts. T2 - EUROCORR 2011 - Developing solutions for the global challenge CY - Stockholm, Sweden DA - 04.09.2011 KW - CO2 KW - Static corrosion KW - High cycle fatigue KW - Steel KW - CCS KW - CO2-storage KW - Corrosion PY - 2011 SP - 1 EP - 7 (Paper 1087) AN - OPUS4-28009 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Witt, Jens A1 - Krebber, Katerina A1 - Demuth, J. A1 - Sasek, L. T1 - Fiber optic heart rate sensor for integration into personal protective equipment T2 - International workshop BioPhotonics 2011 (Proceedings) N2 - This paper reports on a fiber optic sensor for heart rate measurements. The sensor will be integrated into personal protective equipment within the framework of the FP7 EU project i-Protect. Two different sensor prototypes were developed. One is based on fiber Bragg gratings in silica fiber and the other one is based on macrobending effects in polymer optical fiber. T2 - International workshop BioPhotonics 2011 CY - Parma, Italy DA - 08.06.2011 KW - Smart textile KW - Healthcare monitoring KW - Fiber optical sensor KW - FBG KW - Heart rate sensor KW - Macrobending sensor PY - 2011 SN - 978-1-4244-9837-6 DO - https://doi.org/10.1109/IWBP.2011.5954836 IS - Th6.26 SP - 1 EP - 3 AN - OPUS4-24498 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Witt, Jens A1 - Schukar, Marcus A1 - Breithaupt, Mathias A1 - Müller, Bernd R. A1 - Krebber, Katerina T1 - MPOF LPGs as radiation sensors T2 - POF 2011 - 20th International conference on plastic optical fibers (Proceedings) N2 - We investigated to our knowledge for the first time the capabilities of long period gratings (LPG) in single-mode microstructured polymer optical fibre (mPOF) as real-time gamma dosimeter. The fibre is made from polymethyl methacrylate (PMMA) with a polycarbonate jacket. We measured the radiation-induced wavelength shift of the mPOF LPG loss feature wavelength and the radiation-induced attenuation of a mPOF for different wavelength between 600 nm and 800 nm for gamma radiation with an energy distribution between 6 keV and 18 keV. T2 - POF 2011 - 20th International conference on plastic optical fibers CY - Bilbao, Spain DA - 14.09.2011 KW - Microstructured polymer optical fibre (mPOF) KW - Long period grating (LPG) KW - Radiation sensor PY - 2011 SP - 1 EP - 3 AN - OPUS4-24499 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Witt, Jens A1 - Schukar, Marcus A1 - Krebber, Katerina A1 - Demuth, J. A1 - Sasek, L. T1 - Heart rate sensor for integration into personal protective equipment T2 - POF 2011 - 20th International conference on plastic optical fibers (Proceedings) N2 - This paper reports on a fibre optic sensor for heart rate measurement which is developed within the framework of the FP7 EU project i-Protect. Goal is integration of the sensor into personal protective equipment Two different sensor prototypes based on polymer optical fibre (POF) were developed. One is based on long period gratings in microstrutured POF and the other one is based on macrobending effects in POF. T2 - POF 2011 - 20th International conference on plastic optical fibers CY - Bilbao, Spain DA - 14.09.2011 KW - Heart rate sensor KW - Long period grating KW - Macrobending sensor KW - Microstructured POF (mPOF) KW - Personal protective equipment (PPE) KW - Physiological sensor PY - 2011 SP - 1 EP - 5 AN - OPUS4-24500 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Witt, Jens A1 - Breithaupt, Mathias A1 - Erdmann, Jessica A1 - Krebber, Katerina T1 - Humidity sensing based on microstructured POF long period gratings T2 - POF 2011 - 20th International conference on plastic optical fibers (Proceedings) N2 - We investigated the capabilities of long period gratings (LPG) in single-mode microstructured polymer optical fibre (mPOF) for humidity sensing. For that mPOF LPGs were exposed to different humidity levels at a constant temperature of 30°C in a climate chamber. During the long term tests, which took up several weeks, the humidity was changed in several steps while mPOF LPG wavelength and fibre attenuation were measured. We also measured the water uptake of mPOF in environment with different relative humidity. T2 - POF 2011 - 20th International conference on plastic optical fibers CY - Bilbao, Spain DA - 14.09.2011 KW - Microstructured polymer optical fibre (mPOF) KW - Long period grating (LPG) KW - Humidity sensor PY - 2011 SP - 1 EP - 6 AN - OPUS4-24501 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauli, Jutta A1 - Brehm, Robert A1 - Grabolle, Markus A1 - Behnke, Thomas A1 - Mathejczyk, J. A1 - Hamann, F. A1 - Alves, F. A1 - Hilger, I. A1 - Resch-Genger, Ute ED - Achilefu, S. ED - Raghavachari, R. T1 - Dye-biomolecule conjugates and NIR-fluorescent particles for targeting of disease-related biomarkers T2 - Proceedings of SPIE - Reporters, markers, dyes, nanoparticles, and molecular probes for biomedical applications III N2 - Indispensable for fluorescence imaging are highly specific and sensitive molecular probes that absorb and emit in the near infrared (NIR) spectral region and respond to or target molecular species or processes. Here, we present approaches to targeted fluorescent probes for in vivo imaging in the intensity and lifetime domain exploiting NIR dyes. Screening schemes for the fast identification of suitable fluorophores are derived and design criteria for highly emissive optical probes. In addition, as a signal amplification strategy that enables also the use of hydrophobic NIR fluorophores as fluorescent reporters, first steps towards versatile strategies for the preparation of NIR-fluorescent polymeric particles are presented that can be utilized also for the design of targeted and analyte-responsive probes. KW - Fluorescence KW - Fluorescence lifetime imaging KW - Near-infrared KW - NIR KW - Cyanine dye KW - Cancer KW - In vivo imaging KW - Aggregation KW - Nanoparticle PY - 2011 DO - https://doi.org/10.1117/12.876828 SN - 1605-7422 N1 - Serientitel: Proceedings of SPIE – Series title: Proceedings of SPIE IS - 7910 SP - 791014-1 EP - 791014-15 AN - OPUS4-24353 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ehrig, Karsten A1 - Goebbels, Jürgen A1 - Meinel, Dietmar A1 - Paetsch, O. A1 - Prohaska, S. A1 - Zobel, Valentin T1 - Comparison of crack detection methods for analyzing damage processes in concrete with computed tomography T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography (Proceedings) N2 - Analyzing damages at concrete structures due to physical, chemical, and mechanical exposures need the application of innovative non-destructive testing methods that are able to trace spatial changes of microstructures. Here, the utility of three different crack detection methods for the analysis of computed tomograms of various cementitious building materials is evaluated. Due to the lack of reference samples and standardized image quality evaluation procedures, the results are compared with manually segmented reference data sets. A specific question is how automatic crack detection can be used for the quantitative characterization of damage processes, such as crack length and volume. The crack detection methods have been integrated into a scientific visualization system that allows displaying the tomography images as well as presenting the results. T2 - DIR 2011 - International symposium on digital industrial raidology and computed tomography CY - Berlin, Germany DA - 20.06.2011 KW - Crack detection KW - Computed tomography KW - Data visualization PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-243569 SN - 978-3-940283-34-4 IS - DGZfP-BB 128 (Poster 2) SP - 1 EP - 8 PB - Deutsche Gesellscahft für Zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-24356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -