TY - GEN A1 - Beckmann, Jörg A1 - Schmidt, Richard A1 - Ewert, Uwe A1 - Berndt, A. A1 - Strebl, F. T1 - Agenda 2020 for a European Certification System for CBRNE Sensor Systems and Devices - the Concept for a Road Map N2 - Developments for technologies were initiated by the European Commission to improve future response capabilities and strategies to prevent terrorist attacks, to reduce the vulnerability to terrorism and to minimize the extent of damage from terrorist attacks. CBRN civil protection faces a growing significance in this concept and modern detectors and detection systems play the key role for a future reliable functioning that counters terrorism in Europe. The European Union is supporting the project CREATIF which is dedicated to provide a communication platform for technology users and decision makers, providers, and testers. First ideas were designed, strategies developed, preconditions and rules were named for a future internationally recognized certification system. A concept for a future European Certification System for CBRNE Sensor Systems and Devices and Processes has been developed, which is described in more detail. T2 - 1st International symposium on development of CBRN defence capabilities CY - Berlin, Germany DA - 2010-11-30 KW - WMD KW - CBRNE KW - Certification KW - Testing PY - 2010 SN - 978-3-935938-75-4 IS - P10.5 SP - 1603 EP - 1606 CY - Bonn AN - OPUS4-22879 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Osterloh, Kurt A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Threat detection and imaging T2 - 2nd Security research conference Karlsruhe CY - Karlsruhe, Germany DA - 2007-09-12 KW - Digitale Bildbearbeitung KW - Automatische Rauscherkennung und Kompensation PY - 2007 SN - 978-3-86644-147-7 SP - 179 EP - 182 PB - Universitätsverlag Karlsruhe AN - OPUS4-20715 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Osterloh, Kurt A1 - Wrobel, Norma A1 - Kunte, Hans-Jörg A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Making the world a safer place - some know-how already exists T2 - MATEST 2009 CY - Cavtat/Dubrovnik, Croatia DA - 2009-09-23 KW - Existing hazards KW - Threat detection KW - Interdisciplinary approach KW - Existing safety rules and procedures KW - Bridging safety and security KW - Common definitions PY - 2009 SN - 978-953-7283-03-2 IS - #10 SP - 1 EP - 7 AN - OPUS4-20710 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Osterloh, Kurt A1 - Wrobel, Norma A1 - Fratzscher, Daniel A1 - Jechow, Mirko A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Hasenstab, A. T1 - Backscatter radiation - using X-rays for illumination T2 - MATEST 2009 CY - Cavtat/Dubrovnik, Croatia DA - 2009-09-23 KW - X-ray back scatter KW - Unilateral access KW - Twisted slit collimator KW - Pinhole camera principle with high energy radiation PY - 2009 SN - 978-953-7283-03-2 IS - #12 SP - 1 EP - 11 AN - OPUS4-20709 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Redmer, Bernhard A1 - Rädel, Christoph A1 - Osterloh, Kurt A1 - Schnars, U. A1 - Henrich, R. A1 - Schimmelmann, O. A1 - Bavendiek, K. A1 - Jahn, M. T1 - Mobile X-ray Inspection of light weight materials N2 - Digital detectors such as phosphor imaging plates (IP) and digital detector arrays (DDA) allow radiographic inspection with higher efficiency and improved image quality in comparison to the classic film technique. Mobile X-ray flash tubes are used routinely for veterinarian and security applications. New high sensetive IPs and DDAs enable to apply them for inspection of light materials with low X-ray attenuation as in aluminium, plastics and composites. A versatile computed tompgraphy (CT) system was developed for in situ inspection of large aircraft components under production conditions. A gate based planar computed tomograph wsa developed and testes for inspection of integrety of the stringer incorporation. Successful test trials were performed to prove the detection rate of cracks in embedded stringers. Honey comb structures of aircrafts have to be inspected for water inclusions during in-service inspections. Thermography is a powerful method for in house inspections when variations in temperature caused e. g. by sunshine can be excluded. A new X-ray diaphragm was developed for mobile back scatter measurements of large components. This method is insensitive to heat alterations in the field and thus can be applied also outdoors. T2 - International Symposium on NDT in Aerospace CY - Fürth, Germany DA - 2008-12-03 KW - X-ray light materials KW - Computertomography KW - Laminography KW - Backscatter KW - Fibre composites KW - Flash generator PY - 2008 SN - 978-3-940283-12-2 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 114 SP - 99 EP - 111 PB - DGZfP CY - Berlin AN - OPUS4-18927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Christina A1 - Pavlovic, Mato A1 - Takahashi, Kazunori A1 - Ewert, Uwe A1 - Rosenthal, Martina A1 - Brekow, Gerhard A1 - Böhm, R. A1 - Ronneteg, U. A1 - Pitkänen, J. T1 - POD Evaluation of NDE Techniques for Canister-Components for Risk Assessment of Nuclear Waste Encapsulation T2 - 6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurised Components CY - Budapest, Hungary DA - 2007-10-08 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD PY - 2008 SN - 978-92-79-08897-1 U6 - https://doi.org/10.2790/1274 SN - 1018-5593 SP - 168 EP - 179 AN - OPUS4-18589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beckmann, Jörg A1 - Großer, Anja A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Einfluss von Metall - Speicherfolien - Kombinationen auf die Bildqualität in der Computer - Radiographie N2 - Bei der Normgestaltung für Speicherfolien sind die Auswirkungen von Metallfolien und Metallfolienkombinationen auf die Bildqualität von Speicher-folienaufnahmen nicht ausreichend berücksichtigt worden. Es ist bekannt, dass bei Film - Metallfolien - Kombinationen zusätzlich zur Änderung der optischen Dichte und der Filmgranularität auch Änderungen der inneren Unschärfe durch den seitli-chen Energietransport in der Film – Metallfolien - Kombination entstehen, welche überwiegend durch ausgelöste Elektronen und zum Teil durch sekundäre Strahlung hervorgerufen werden. Gleichzeitig dienen die Metallfolien bei Röntgenaufnahmen mit Film als Streustrahlfilter und können zur Verbesserung des Bildkontrastes bei-tragen. Die Mechanismen zur Erzeugung des virtuellen Röntgenbildes und dessen Visualisierung sind in Speicherfolien nicht mit denen in einem Röntgenfilm iden-tisch. Demzufolge können die in den Normen festgelegten Vorschriften zum Einsatz von Metallfolien in der Filmradiographie nicht auf Speicherfolien uneingeschränkt übertragen werden. Anhand der hier erzielten Ergebnisse lassen sich Empfehlungen zum zukünftigen Einsatz der Metallfilter und -folienkombinationen für die Speicher-folientechnik zur Verbesserung der Bildgüte ableiten. T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Poster 29) SP - 1 EP - 8 AN - OPUS4-18413 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beckmann, Jörg A1 - Großer, Anja A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Einfluss von Metall-Speicherfolien-Kombinationen auf die Bildqualität in der Computer-Radiographie T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 KW - Speicherfolien KW - Durchstrahlungsprüfung KW - Computer Radiographie KW - Metallfolien PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Poster 29) SP - 847 EP - 856 AN - OPUS4-18351 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Beckmann, Jörg A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Zscherpel, Uwe A1 - Jechow, Mirko A1 - Großer, A. T1 - Fehlergrößenabhängige Kontrastreduktion und zusätzliche Unschärfe durch Streustrahlung reduzierendie Bildqualität radiologischer Abbildungen - Film und digitale Detektoren im Vergleich T2 - DACH-Jahrestagung 2008 - Zerstörungsfreie Materialprüfung, ZfP in Forschung, Entwicklung und Anwendung CY - St. Gallen, Schweiz DA - 2008-04-28 KW - Digitale Radiologie KW - Streuverhältnis KW - Strahlenkontrast KW - Unschärfe PY - 2008 SN - 978-3-940283-09-2 IS - DGZfP-BB 113 (Di.1.A.1) SP - 133 EP - 144 AN - OPUS4-18349 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Osterloh, Kurt A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Beckmann, Jörg A1 - Hentschel, Manfred P. ED - Beyerer, J. T1 - Advanced radiological technologies for imaging and characterisation of threats T2 - 2nd Security Research Conference "Future Security" CY - Karlsruhe, Germany DA - 2007-09-12 KW - Threat Detection KW - Dual Energy KW - Multiple View Inspection KW - Terahertz Imaging KW - Explosives PY - 2007 SN - 978-3-86644-147-7 SP - 116 EP - 119 PB - Universitätsverl. CY - Karlsruhe AN - OPUS4-18348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -