TY - CONF A1 - Meermann, Björn A1 - Ley, Philip A1 - Metzger, Matthias A1 - Sturm, Manfred T1 - Fluoranalytik mittels hochauflösender-continuum source Graphitrohr Molekülabsorptionsspektrometrie (HR-CS-GFMAS) - Screening von Organofluor im Oberflächenwasser N2 - Vortrag zur Entwicklung von Organo-Fluor Summenparametermethoden auf Basis der HR-CS-GFMAS für die Umweltanalytik T2 - PerFluSan Treffen; 1. Workshop zur PFC-Sanierung_Schwerpunkt Analytik CY - Karlsruhe, Germany DA - 25.06.2019 KW - Hochauflösende-continuum source Graphitrohr Molekülabsorptionsspektrometrie (HR-CS-GFMAS) KW - Fluorierte Organische Verbindungen KW - Umweltanalytik KW - (Organisch gebundenes) Fluor-Summenparameter PY - 2019 AN - OPUS4-48632 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - von der Au, Marcus A1 - Schwinn, M. A1 - Kuhlmeier, K. A1 - Büchel, C. A1 - Meermann, Björn T1 - Development of an automated on-line purification HPLC single cell-ICP-MS approach for fast diatom analysis JF - Analytica Chimica Acta N2 - The most challenging part in performing a single cell ICP-MS (sc-ICP-MS) approach is the sample preparation, in particular the reduction of the ionic background. This step is, in many cases, time-consuming and required for each sample separately. Furthermore, sc-ICP-MS measurements are mostly carried out "manually", given the fact that present systems are not allowing for an automated change of samples. Thus, within this work, we developed an approach based on a HPLC system coupled on-line with sc-ICP-MS via a set of switching valves as well as an in-line filter for automated cell washing. This set-up enables the ionic background removal as well as analysis of single cells completely automated without any manual sample pretreatment. Our approach was applied for the analysis of the single celled diatom species Cyclotella meneghiniana, a marine diatom species, on the basis of Mg24 and facilitates testing in 11 min per sample, requiring only around 10,000 cells in a volume of 10 µL and approx. 10 mL of a 5% MeOH/95% deionized water (v/v) mixture. Even at extremely saline culturing media concentrations (up to 1000 mg L-1 magnesium) our on-line approach worked sufficiently allowing for distinction of ionic and particulate fractions. Furthermore, a set of diatom samples was analyzed completely automated without the need for changing samples manually. So, utilizing this approach enables analyzing a high quantity of samples in a short time and therefore in future the investigation of ecotoxicological effects is simplified for example in terms of metal accumulation by taking biovariability into account. KW - Single cell-ICP-MS KW - Diatoms KW - Ecotoxicology testing KW - Automated system PY - 2019 DO - https://doi.org/10.1016/j.aca.2019.05.045 SN - 1873-4324 VL - 1077 SP - 87 EP - 94 PB - Elsevier AN - OPUS4-48567 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -