TY - JOUR A1 - Klinge, A A1 - Mönig, J A1 - Ziegert, C A1 - Richter, Matthias A1 - Kalbe, Ute A1 - Horn, Wolfgang A1 - Röhlen, U A1 - Rauscher, S A1 - Roswag-Klinge, E T1 - upMIN 100 – upcycling of mineral construction and demolition waste to substitute natural aggregates in earthen building materials N2 - The construction sector is one of the most resource-intensive sectors in Germany and is responsible for 40 % of CO2 emissions. Around 517 million tons of mineral raw materials are required annually for the construction of buildings in Germany. At the same time, mineral construction waste was the largest material flow at 229.3 million tons (2020). The rates of construction and demolition waste (CDW) recycling have increased since 2000, especially for mineral waste. Nevertheless, the majority of recycled aggregates are used in technically largely unregulated applications (e.g. road construction). This downcycling leads to a loss of valuable resources for technically and economically valuable applications. The upMIN 100 research project is investigating the question of whether and to what extent recycled CDW is suitable as an additive an binder in earthen building materials. The focus is placed on grain sizes of < 2 mm, which are currently predominantly landfilled, as there are at present no regulations for their use in building products. The soil matrix of earthen building materials however, naturally contains of different grain sizes, whith < 2mm – 0,063 for aggregates and < 0.063 mm as a binder. Therefore, the focused grain sizes (sand, clay and silt) could have a high usage potential. In order to enable the use of CDW, the technical feasibility must be ensured, quality requirements for source materials (e.g. threshold values for pollutants in terms of health and environmental compatibility and hazardous substances) and permissible proportions of recycled aggregates must be defined. Two different building material developments (earth blocks and -plaster)were used to assess both, the technical feasibility as well the pollutant content of the recycled aggregate and its final emissions into the indoor air. For both materials two mixtures could be established, that also meet the mechanical specifications according to the DIN standard, such as the compressive strength. A method was developed to design material mixtures with a high amount of CDW that comply with the defined limit values. The mixtures reached a recycling rate of 28 % with high mechanical properties and 70 % with minimum strength requirements. KW - Mineral waste KW - Upcycling KW - Earthen building product KW - Circular construction PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652831 DO - https://doi.org/10.1088/1755-1315/1554/1/012084 SN - 1755-1307 VL - 1554 IS - 1 SP - 1 EP - 9 PB - IOP Publishing AN - OPUS4-65283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Analytische Untersuchungen für Vitrinenbaumaterialien am Beispiel des BEMMA-Schemas N2 - BEMMA ist die Kurzbezeichnung für ein Verfahren zur Bewertung von Emissionen aus Materialien für Museumsausstattungen. Die Bewertung der Materialien erfolgt nach StAA-QMH-4.2-033. Mit diesem Verfahren lassen sich flüchtige organische Verbindungen aus modernen Werkstoffen, die in mittelbarem Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen, untersuchen und bewerten. Die Vitrinenbaumaterialien, nicht die Vitrine, werden im Hinblick auf ihre Emissionen bewertet. Die Ergebnisse der Messungen werden auch vor dem Hintergrund von realen Vitrinenmessungen eingeordnet und die Herausforderungen bei der Probenahme dargestellt. T2 - Klima- und Schadstoffmanagement in der passiven Vitrine Aktuelle Forschungsergebnisse CY - Berlin, Germany DA - 13.10.2025 KW - Emission KW - BEMMA KW - Vitrinen KW - VOC PY - 2025 AN - OPUS4-64529 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Klein, Luise A1 - Horn, Wolfgang A1 - Bethke, Robert T1 - Bestimmung der Aufnahmeraten von VVOCs aus Raumluft in Passivprobenahmesystemen N2 - Für die Bewertung der Innenraumluftqualitat ist die Bestimmung der Konzentration von sehr flüchtigen organischen Verbindungen (very volatile organic compounds — VVOCs) von großer Wichtigkeit. Im Besonderen bei den Deutschen Umweltstudien zur Gesundheit (GerES) des Umweltbundesamts erfolgt die Probenahme von flüchtigen organischen Verbindungen (VOCs) üblicherweise mit Passivsammlern, über deren material- und substanzspezifische Aufnahmeraten Rückschlisse auf die Konzentration der einzelnen Verbindungen gezogen werden können. Ziel dieses Projekts im Ressortforschungsplan (REFOPLAN) ist es, von 55 ausgewählten VVOCs die realen Aufnahmeraten auf Thermodesorptionsrohren als Passivsammlern experimentell zu bestimmen. Dafür wird eine entwickelte Analysemethode für VWOCs mittels Thermodesorption-Gaschromatographie/Massenspektrometrie (TD-GC/MS) verwendet. Passivsammler mit verschiedenen Adsorbenzien werden für sieben Tage (23°C, 50 % r.E) mit den VVOCs exponiert. Carbograph 5TD weist für die ersten getesteten VVOCs die höchsten Aufnahmeraten auf. KW - VVOC KW - Passivsammler KW - Innenraumluft KW - Umweltstudien PY - 2025 DO - https://doi.org/10.37544/0949-8036-2025-03-04-65 SN - 0949-8036 VL - 85 IS - 03-04 SP - 65 EP - 70 PB - VDI Fachmedien GmbH & Co. KG CY - Düsseldorf AN - OPUS4-63635 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Müller, Birgit T1 - Low-odour and low-emission indoor products - Nose vers. odour threshold values N2 - To achieve good air quality in buildings, it is necessary to remove, avoid or reduce cleaning loads through ventilation. To reduce the cleaning loads and their effect on the odour perception of the occupants, a sensory test in indoor spaces and on building products is necessary in addition to VOC emission measurements of the contaminants. ISO 16000-28 provides the basis for odour assessment of products using a human olfactory panel. Through many years of experience and testing of these methods, it can now be assumed that reproducible odour ratings are available for many products used indoors. An odour measurement is mandatory for the Blue Angel for carpets and is being tested for environmentally friendly resilient floor coverings. Based on the results of an earlier project and new results of the upcoming study, the ISO should be revised and completed. The project investigates the odour and VOC emissions of building products based on natural raw materials. The data generated is used to address several issues, which are briefly explained below. Floor coverings based on linoleum and rubber are included in the Blue Angel eco-label with an odour assessment. The aim of the project is to clarify whether other assessment methods in addition to intensity can provide better information. Positive hedonics have an influence on the intensity assessment. Typically, building products show high intensity with low hedonic values. Results for wood-based products often show high intensity and positive hedonics. Based on these examples, an appropriate odour assessment of wood-based products for the Blue Angel, supported by research results, should be possible. The concept of the odour guide value which is based on odour threshold values was renewed in 2023. This approach will now be compared with the standardised odour measurement (16000-28). This assessment is based on GC/MS measurements and uses odour thresholds analytically when panel-based odour assessment is not possible. For this procedure well defined odour thresholds are necessary T2 - AIRMON 2025 The 11th International Symposium on Modern Principles of Air Monitoring and Biomonitoring. CY - Loen, Norway DA - 15.06.2025 KW - Emission KW - Indoor air quality KW - Materials emissions test KW - VOC KW - Geruch PY - 2025 UR - https://stami.no/en/wp-content/uploads/sites/2/2025/06/Programhefte-Airmon-2025-Juni-10-YTH.pdf AN - OPUS4-63634 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Klein, Luise A1 - Bethke, Robert T1 - Determination of uptake rates of VVOCs and carbonyls in indoor air on passive sampling system N2 - The identity and concentration of volatile contaminants are important factors in ensuring a healthy indoor environment. Volatile organic compounds (VOCs) in indoor air can be determined by using passive samplers that are exposed to the air for a well-defined period of time. This sampling method is often used in environmental surveys, e.g. the German Environmental Survey (GerES). Conclusions about indoor air concentrations can be drawn from substance and adsorption material specific uptake rates. For the assessment of indoor air quality, highly volatile organic compounds may also be substantial, but for many of these substances realistic uptake rates and suitable analytical methods are lacking. A small chamber is used to generate gas atmospheres with constant concentrations of the analytes at 23 °C and 50 % relative humidity. For a large number of compounds, a very small flow of pure liquid VVOCs is introduced into the chamber via a syringe pump and mixed with a constant flow of clean and humidified air. A gas mixture from cylinders is also used for this purpose. Carbograph 5TD has already been proven as a suitable sorption material for active sampling for most of VVOCs. With this procedure up to 55 different VVOCs should be tested in this study. Stable concentrations of gas phase atmospheres of the first group of VVOCs (acetone, 2-butanone, methyl acrylate) were produced for exposure of passive samplers. Comparison of different adsorbent materials showed that Carbograph 5TD was the most suitable for passive sampling of these substances, with higher uptake than Carbopack X and Tenax® TA. Very strong adsorbents are not suitable for this experimental design as it adsorbs larger amounts of water. The effective uptake rates were calculated for the first three VVOCs on Carbograph 5TD tubes and an exposure time of 7 days. The same experiment will be performed for all VVOCs and ideally one material should be the best option for all of them. T2 - AIRMON 2025 The 11th International Symposium on Modern Principles of Air Monitoring and Biomonitoring. CY - Loen, Norway DA - 15.06.2025 KW - VVOC KW - Air quality KW - Passive sampling PY - 2025 UR - https://stami.no/en/wp-content/uploads/sites/2/2025/06/Programhefte-Airmon-2025-Juni-10-YTH.pdf AN - OPUS4-63632 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, Birgit A1 - Brandt, Simone A1 - Badura, André A1 - Knigge, Anton A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Geruchs- und emissionsarme Produkte für eine gesunde Innenraumluft - Entwicklung von Anforderungen für den Blauen Engel bei innenraumrelevanten, großflächigen Produkten N2 - Gerüche in Innenräumen können belästigend wirken und das Wohlbefinden sowie die Gesundheit beeinflussen. Hauptziel der Untersuchungen ist es zu prüfen, ob die Vergabekriterien des Blauen Engels für die Produktgruppen „Elastische Bodenbeläge“ (DE-UZ 120) und „Emissionsarme Bodenbeläge, Paneele und Türen aus Holz und Holzwerkstoffen für Innenräume“ (DE-UZ 176) um geruchsrelevante Aspekte ergänzt werden können. Dies ist erstrebenswert, da Untersuchungen in Vorgängerprojekten gezeigt haben, dass die gemessenen Emissionen untersuchter Produkte zwar abnehmen, die Geruchsbelastung jedoch in etwa gleichgeblieben ist. Die Ergebnisse der Untersuchungen zeigen, dass es möglich ist Anforderungen an den Geruch der Produkte zu stellen. Ferner wird untersucht und gezeigt, dass die bislang vorläufig festgelegte Schwelle einer empfundenen Intensität von 7 pi für die Zulassung von Bauprodukten gemäß Schema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (AgBB) und Blauer Engel, als Beurteilungsmaßstab geeignet ist. Der im AgBB-Schema zugrunde gelegte Zusammenhang zwischen der geruchlichen Zumutbarkeit und der empfundenen Intensität kann mit den durchgeführten Messungen untermauert werden. Es kann gezeigt werden, dass bei Tests mit großen, ungeschulten Personengruppen etwa 70% der Probandinnen und Probanden Produkte mit einer empfundenen Intensität von bis zu 7 pi geruchlich als zumutbar empfinden. Zur Bewertung der empfundenen Intensität wird ein Vergleichsmaßstab verwendet. Die Einhaltung konstanter Bedingungen für die Temperatur und die relative Feuchte bei den Messungen ist von großer Bedeutung, da diese einen Einfluss auf die Messergebnisse haben. Daher werden Untersuchungen bei unterschiedlichen Temperaturen und relativer Luftfeuchte, die mit einer eigens dafür gebauten kleinen raumlufttechnischen Anlage eingestellt werden können, durchgeführt. Die Ergebnisse belegen, dass die Einhaltung konstanter Prüfbedingungen wichtig ist und zeigen deren Einfluss auf die Geruchwahrnehmung. In einem neuen Luftqualitätslabor der HTW Berlin können Innenräume unter standardisierten Bedingungen geprüft werden. Es werden vergleichende Messungen mit Emissionsprüfkammertests durchgeführt, um zu prüfen, ob ähnliche Ergebnisse erreicht werden können. Das Ziel ist es, die Räume später für sensorische Messungen mit verschiedenen Ausstattungen zu nutzen. Das Vorhaben baut auf den Ergebnissen der Vorhaben UBA Texte 35/2011 „Sensorische Bewertung der Emissionen aus Bauprodukten – Integration in die Vergabegrundlagen für den Blauen Engel und das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten“ (Müller, 2011) und UBA Texte 92/2019 „Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude – Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht“ (Müller, 2019) auf. KW - Emission KW - Indoor air quality KW - VOC KW - Geruch KW - Bauprodukte PY - 2025 DO - https://doi.org/https://doi.org/10.60810/openumwelt-7610 SN - 1862-4804 VL - 78/2025 SP - 1 EP - 214 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-63341 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Klinge, Andrea A1 - Mönig, Julian A1 - Kalbe, Ute A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Ziegert, Christof A1 - Röhlen, Ulrich A1 - Roswag-Klinge, Eike T1 - upMIN 100 – upcycling MINeralischer Bau- und Abbruchabfälle zur Substitution natürlicher Gesteinskörnungen in Lehmbaustoffen T1 - upMIN 100 – Upcycling mineral construction and demolition debris as a substitute for natural aggregates in earth building materials N2 - Um zukünftig die Entnahme von Primärrohstoffen und die Deponierung von geeignetem Bodenaushub zu vermeiden, wurde im Forschungsvorhaben «upMIN100» der Einsatz von rezyklierten Gesteinskörnungen < 2 mm in Lehmbaustoffen untersucht. Diese Korngrößen aus Rezyklaten, die je nach Ausgangsstoffen und Produkt 5 – 70 % des fertigen Baustoffs ausmachen, waren zum Zeitpunkt des Projektstarts in den gültigen Lehmbaustoff-Normen DIN 18945 – 18948 nicht zugelassen, da diese als Zusatzstoffe nur natürliche Gesteinskörnungen nach DIN EN 12620, Mehl aus mörtelfreien Ziegeln sowie Blähperlit etc. nach DIN EN 13055-1 und als Bindemittel nur Baulehm aus natürlichen Vorkommen vorsahen. Um den Einsatz von rezyklierten Bau- und Abbruchabfällen für Lehmbaustoffe in der Norm zu ermöglichen, mussten daher die technische Durchführbarkeit, Qualitätsanforderungen an Ausgangsstoffe (z.B. Schadstoffgrenzwerte in Bezug auf Gesundheits- und Umweltverträglichkeit) sowie zulässige Anteile der Rezyklate geregelt werden. Aktuelle Sortier- und Aufbereitungsmethoden wurden im Hinblick auf die technische sowie die wirtschaftliche Machbarkeit überprüft und auf eine mögliche Optimierung untersucht. Um Fragen zur technischen Machbarkeit beantworten zu können, wurde im Vorhaben die exemplarische Entwicklung von zwei wiederverwendbaren Lehmbaustoffen (Lehmstein, Lehmputzmörtel) angestrebt, um zukünftig sowohl das Abfallaufkommen als auch die Rohstoffinanspruchnahme zu reduzieren. Zum einen sollten die Zuschläge bis zu 100% aber auch das natürliche Bindemittel Ton zu 80% – 100% substituiert werden. Der Machbarkeitsnachweis für beide Entwicklungen wurde in Form eines Prototyps mit einem Technologie-Reifegrad 4–5 (TRL 4–5) erbracht. N2 - To avoid the extraction of primary raw materials and the landfilling of suitable excavated soil in the future, the use of recycled aggregates < 2 mm in earth building materials was investigated in the “upMIN 100” research project. These grain sizes from recycled materials, which make up 5–70 % of the finished building material depending on the source materials and product, were not permitted in the applicable earth building material standards DIN 18945–18948 at the time the project started, as these only allow natural aggregates in accordance with DIN EN 12620, flour from mortarfree bricks and expanded perlite etc. as additives in accordance with DIN EN 13055-1 and only building clay from natural sources as a binder. For the use of recycled construction and demolition waste for earth building materials in the standard, the technical feasibility, quality requirements for source (e. g. limit values for harmful substances in terms of health and environmental compatibility) and permissible proportions of recyclates had to be regulated. Current sorting and processing methods were reviewed in terms of technical and economic feasibility and examined for possible optimisation. To ascertain the technical feasibility of the use of recycled construction demolition waste for earth building materials, the project developed two reusable earth building materials (earth blocks, clay plaster mortar) as examples of both waste reduction and of the use of raw materials in the future. On the one hand, up to 100 % of the aggregates and 80–100 % of the natural binder clay should be substituted. The proof of concept for both developments was provided in the form of a prototype with a technology readiness level 4–5 (TRL 4–5). T2 - Lehm 2024 Fachtagung CY - Weimar, Germany DA - 27.09.2024 KW - Recycled aggregates KW - Earthen building materials KW - Contaminants KW - Reuse KW - Resources PY - 2024 SP - 1 EP - 10 CY - Weimar AN - OPUS4-62612 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - VOC-Sampling inside display cases with focus on BEMMA evaluation N2 - Museum display cases aim to protect art and cultural goods not only from theft and vandalism, but also from dirt and dust. An often-heard argument within a call for tender of new display cases is that there should be no emission inside of the display case. This is nearly impossible for new ones especially when they must also fulfill the requirement of an air change rate of less than 0.1 per day. For example, constructions or decorations in exhibition spaces, storage containers in depot rooms, and exhibition display cases release volatile substances that might lead to irreversible changes or, under certain circumstances, damage to the stored or displayed objects. In Germany beneath the well-established Oddy-test also the BEMMA procedure is used to evaluate the construction materials. For larger amounts of display cases control measurements of VOCs at the end of construction or buildup is quite common. However, what is necessary to measure the air inside of display cases. What are the circumstances when the display cases were closed before the test period? Is it possible to organize a clean environment for reliable measurements. How comparable are the resulting VOCs with results from BEMMA test and control measurement at the end. The BEMMA procedure should include a further VOC-test at 60 °C. What are the benefits of this enlargement. Mainly materials that have a high potential to store VOCs inside of the material in combination with a less permeable surface should be evaluated stricter than others. T2 - IAQ 2024 The International Conference on Indoor Air Quality in Heritage and Historic Environments CY - New York, USA DA - 18.11.2024 KW - Emission KW - Air quality KW - Display cases KW - VOC PY - 2024 AN - OPUS4-61967 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Musyanovych, A. A1 - Grimmer, Christoph A1 - Sadak, A. E. A1 - Heßling, L. A1 - Lüdicke, M. A1 - Bilsel, M. A1 - Horn, Wolfgang A1 - Richter, Matthias T1 - Polymer Capsules with Volatile Organic Compounds as Reference Materials for Controlled Emission N2 - Encapsulation of volatile organic compounds (VOCs) that could evaporate at a defined rate is of immense interest for application in emission reference materials (ERMs). Polyurethane/polyurea microcapsules with various VOC active ingredients (limonene, pinene, and toluene) were successfully produced by interfacial polymerization with Shirasu porous glass membrane emulsification in a size range between 10 and 50 μm. The effect of surfactant, VOC, monomer(s) type, and ratio has a great effect on the formulation process and morphology of capsules. The type of VOC played a significant role in the encapsulation efficiency. Due to the difference in vapor pressure and VOC/water interfacial tension, the formulation for encapsulation was optimized for each individual VOC. Furthermore, to achieve effective stability of the large droplets/capsules, a combination of ionic and nonionic surfactants was used. Optical and scanning electron microscopy, Fourier transform infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA), were used to characterize the optimized microcapsules. The results showed that the obtained microcapsules exhibited a spherical shape and core–shell morphology and featured characteristic urethane-urea bonds. The amount of encapsulated VOC ranges between 54 and 7 wt %. The emission tests were performed with the help of the emission test chamber procedure (EN 16516). The limonene-loaded polyurethane/polyurea microcapsules show a change in emission rate of less than 10% within 14 days and can be considered as a potential candidate for use as an ERM. KW - Polymer microcapsules KW - Membrane emulsification KW - Polyaddition KW - Volatile organic compound (VOC) KW - Emission testing PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-619227 DO - https://doi.org/10.1021/acsami.4c12826 SN - 1944-8252 VL - 16 IS - 50 SP - 69999 EP - 70009 PB - ACS AN - OPUS4-61922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kalbe, Ute A1 - Schröder, Simon Alexander A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Stephan, Ina A1 - Hohmann, Gloria A1 - Ziegert, Christof T1 - Identifikation und Einordnung von historischen Lehmbauteilen für die Wiederverwendung hinsichtlich Anreicherung von Schadstoffen und bauschädlichen Salzen T1 - Identification and classification of historical earth construction elements for recycling in respect of accumulation of pollutants and structurally damaging salts N2 - Lehmbaustoffe, einschließlich Lehm aus dem historischen Baubestand, bieten ein hohes Potenzial für ihre Wiederverwendbarkeit und die Schonung natürlicher Ressourcen. Zur Bewertung des Wiederverwendungspotenzials gibt es nur wenige Studien hinsichtlich der Schadstoffbelastung und der Anreicherung von Salzen in Gebäuden aus dem historischen Bestand. Tonminerale, die in Lehmbaustoffen als Bindemittel fungieren, können Schadstoffe binden. Die Region Mitteldeutschland ist geprägt durch jahrzehntelange Einwirkung erheblicher Schadstoffemissionen aus der Chemie- und Braunkohleindustrie. Der Eintrag von Schadstoffen in Lehmbaustoffe ist außerdem aus geogenen Hintergrundbelastungen denkbar, z. B. in Auenböden beeinflusst durch Einträge aus dem Erzbergbau. Salzbildende Anionen wie Chloride oder Nitrate können aufgrund ihrer hohen Löslichkeit mittels kapillarer Kräfte durch die Porenstruktur transportiert werden. In Lehmwänden können sie vor allem in oberflächennahen Lagen, in denen höhere Verdunstungsraten vorherrschen, durch Bindung mit in Lösung vorliegenden oder baustoffeigenen Kationen auskristallisieren und bauschädliche Salze ausbilden. Auch durch spezifische Nutzungen akkumulierte Schadstoffe, z. B. durch die Einwirkung von Tabakrauch, könnten theoretisch einer Wiederverwendung von Lehm entgegenstehen. In Anbetracht der Herausforderungen hinsichtlich der klimatischen und gesellschaftlichen Veränderungen, sind wissenschaftliche Erkenntnisse im Lehmbau erforderlich, die eine Integration in eine nachhaltige Kreislaufwirtschaft ermöglichen. Bei bisherigen Gesetzgebungsverfahren zu rezyklierten Baustoffen wurden Lehmbaustoffe noch nicht berücksichtigt. Ziel einer Vorstudie im Rahmen der WIR!-Initiative GOLEHM ist die Überprüfung der Wiederverwendbarkeit Wiederverwendbarkeit von Lehmbaustoffen aus historischen Bauten an Stichproben hinsichtlich der Umwelt- und Nutzerverträglichkeit. Für den Raum Mitteldeutschland können damit Anhaltspunkte darüber gegeben werden, welche Schadstoffe und bauschädlichen Salze in welchem Maße in Lehmbaustoffen aus dem Gebäudebestand erwartet werden können. Daraus können Hinweise zum Umgang mit Lehmbaustoffen aus historischen Gebäuden abgeleitet werden. Darüber hinaus wurden exemplarisch an zwei Gebäuden mikrobiologische Untersuchungen zur Ermittlung einer möglichen Belastung mit Schimmelpilzen vorgenommen. N2 - Earth construction materials, including earth from historical building stock, offer high potential in terms of their recyclability and sparing use of natural resources. Yet, only a few studies have been conducted on the levels of pollutants and the accumulation of salts in buildings from the historical building stock to enable an assessment of the potential for recycling. The aim of a preliminary study as part of the GOLEHM Initiative from WIR! is to use spot checks to review the recyclability of earth construction materials from historical buildings in terms of environmental impact and tolerance by users. This could provide indicators for the Central Germany region on which pollutants and structurally damaging salts can be expected in earth construction materials from the building stock and to what extent, allowing conclusions to be drawn on how to manage earth construction materials from historical buildings. Additionally, microbiological inspections of two sample buildings were performed to assess a potential contamination with mould. T2 - Lehm 2024 Fachtagung CY - Weimar, Germany DA - 27.09.2024 KW - Lehm KW - Wiederverwendung KW - Kreislaufwirtschaft KW - Schadstoffe KW - Bauschädliche Salze PY - 2024 SP - 1 EP - 8 CY - Weimar AN - OPUS4-61883 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Klinke, A. A1 - Horn, Wolfgang A1 - Kalbe, Ute A1 - Mönig, J. A1 - Richter, Matthias A1 - Roswag-Klinge, E. A1 - Röhlen, U. A1 - Ziegert, C. T1 - Upcycling mineralischer Bau- und Abbruchabfälle (upMIN 100) N2 - Der Bausektor ist einer der ressourcenintensivsten Sektoren in Deutschland und ist für 40 % der CO2-Emissionen verantwortlich. Für den Bau von Gebäuden werden in Deutschland jährlich rund 517 Millionen Tonnen mineralische Rohstoffe benötigt. Gleichzeitig stellen mineralische Bauabfälle mit 229,3 Millionen Tonnen (2020) den größten Stoffstrom dar. Die Quoten des Baustoffrecyclings sind seit 2000 gestiegen, insbesondere bei mineralischen Abfällen. Dennoch wird der Großteil der recycelten Gesteinskörnungen in technisch weitgehend ungeregelten Anwendungen (z.B. Straßenbau) eingesetzt. Durch dieses Downcycling gehen wertvolle Ressourcen für technisch und wirtschaftlich wertvolle Anwendungen verloren. Das Forschungsprojekt upMIN100 geht der Frage nach, ob und inwieweit sich rezyklierte mineralische Bau- und Abbruchabfälle als Zusatzstoff in Lehmbaustoffen wie Lehmputzen und Lehmsteinen eignen. Der Fokus liegt dabei auf der Korngröße < 2 mm, die derzeit überwiegend deponiert wird, da es derzeit keine Vorschriften für den Einsatz in Bauprodukten gibt. Um den Einsatz von Bau- und Abbruchabfällen zu ermöglichen, müssen die technische Machbarkeit sichergestellt, Qualitätsanforderungen an die Ausgangsmaterialien (z.B. Grenzwerte für gesundheits- und umweltrelevante Schadstoffe und gefährliche Substanzen) und zulässige Anteile an rezyklierten Gesteinskörnungen definiert werden. Um negative Auswirkungen auf die Gebäudenutzer zu vermeiden, wurden die entwickelten Baumaterialien auf die in den mineralischen Abfällen enthaltenen Schadstoffe sowie auf Emissionen in die Innenraumluft geprüft. Außerdem sollen die aus mineralischen Abfällen hergestellten Lehmbauprodukte frei von Schadstoffen sein, um eine Rückführung in die Umwelt zu ermöglichen. Nach der Ersatzbaustoffverordnung (EBV) entspricht dies dem Kriterium BM-0. KW - Mineralische Baustoffe KW - Baustoffrecycling KW - Lehmbaustoffe PY - 2024 SN - 1868-0097 SP - 1 EP - 150 AN - OPUS4-61820 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grimmer, Christoph A1 - Richter, Matthias A1 - Neuhaus, T. A1 - Prinz, Carsten A1 - Strzelczyk, Rebecca Skadi A1 - Colakoglu, Irem A1 - Horn, Wolfgang T1 - Towards a multi-VOC emission reference material with temporally constant emission profile for QA/QC of materials emission testing procedures N2 - Emission reference materials (ERMs) are sought after to further control and improve indoor air quality. The impregnation of porous materials with volatile organic compounds (VOCs) is a promising approach to produce ERMs. Different VOCs were used to impregnate various porous materials (mainly zeolites, activated carbons and a metal organic framework). The influence of different methodological parameters and material properties were studied to optimize the impregnation procedure and to find the best material/VOC combination. The impregnation procedure remains quite irreproducible, nevertheless, very good ERM candidates were identified. Two materials (zeolite 4 and AC 1 impregnated with n-hexadecane) showed a very stable emission over 14 days (<10 % change). Another material (AC 1 impregnated with toluene) showed a declining emission profile but with a very good in-batch reproducibility and a storage stability of up to 12 months. KW - Emission reference material KW - Porous materials KW - Indoor air quality KW - Emission test chamber KW - CO2 assisted impregnation KW - EN 16516 PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-612238 DO - https://doi.org/10.1016/j.chemosphere.2024.143437 SN - 1879-1298 VL - 366 SP - 1 EP - 8 PB - Elsevier AN - OPUS4-61223 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Wilke, Olaf T1 - Volatile organic compounds from building products - Results from seven proficiency tests with emission test chambers conducted between 2008 and 2021 N2 - Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test every two years using well-characterised test materials (one sealant, one furniture board and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 41 VOCs were included of which 37 gave test chamber air concentrations between 10 and 98 µg/m³. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Four compounds had higher concentrations between 250 and 1105 µg/m³. The relative standard deviations (RSD) of BAM proficiency tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 23% in 2021. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%. T2 - Proficiency Testing in Analytical Chemistry, Microbiology and Laboratory Medicine CY - Windsor, United Kingdom DA - 25.09.2023 KW - Proficiency Test KW - VOC-Emission KW - Chamber-test PY - 2023 AN - OPUS4-59694 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias T1 - Round robin tests of odour and VOC emissions from building products – What have we learned so far? N2 - Emission testing of volatile organic compounds (VOC) and odour from materials and products is commonly based on emission test chamber measurements. These measurements are often the basis of mandatory or voluntary labelling procedures. To ensure the comparability of results from different testing laboratories their performance must be verified. For this purpose, round robin tests (RRTs) are conducted. Bundesanstalt für Materialforschung und - prüfung (BAM) offers such a RRT every two years using well characterised test materials with defined VOC emissions. In addition to the VOC quantification, the evaluation of odour is also implemented in the round robin tests. At the beginning, only perceived intensity (PI) was tested but over the years also the acceptance evaluation was considered. In principle, the results of PI and acceptance evaluation are comparable. The advantage of PI is the lower number of panel members necessary for one evaluation. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Perceived intensity KW - VOC-emission KW - Poficiency test KW - Chamber test KW - Odour PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580001 SP - 434 EP - 436 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58000 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Odour testing of building products: Examinations for an on-going development of the test standard ISO 16000-28 N2 - VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Building material KW - Odour KW - Perceived intensity KW - VOC KW - Emission test chamber PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580070 SP - 345 EP - 352 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - de Krom, I. A1 - Heikens, D. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Richter, Matthias A1 - Baldan, A. T1 - Metrological generation of SI-traceable gas-phase standards and reference materials for (semi-) volatile organic compounds N2 - EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions. KW - SVOC KW - Dynamic calibration gas mixtures KW - Reference materials KW - Indoor air KW - Thermal desorption PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-565978 DO - https://doi.org/10.1088/1361-6501/aca704 VL - 34 IS - 3 SP - 1 EP - 13 PB - IOP Publishing AN - OPUS4-56597 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Musyanovych, A. A1 - Grimmer, Christoph A1 - Sadak, A. E. A1 - Heßling, L. A1 - Bilsel, M. A1 - Horn, Wolfgang A1 - Richter, Matthias T1 - Polymeric Capsules with VOCs for Controlled Emission N2 - Micro-(nano-)encapsulation technology involves building of a barrier between the core and the environment and offers a number of benefits to preserve the functional and physicochemical properties of core material. Tremendous progress has been made in synthesizing well-defined capsules to achieve desired properties such as particle size, chemical composition, and controlled release of the payload. Encapsulation of volatile organic compounds (VOCs) that could evaporate with a defined rate is of immense interest for application in emission reference materials (ERM). These are urgently needed for quality assurance and quality control purposes (QA/QC) required by test standards for the determination of chemical emissions of construction and other materials for interior use. As such ERMs are hardly available on the market, the EU-funded EMPIR project MetrIAQ [1] was started to fill this gap by developing a material with temporally constant emission of VOCs typically found in indoor air. Different capsules in a size range between 5 and 50 μm were synthesized through an interfacial polyaddition/polycondensation reaction in direct (water-in-oil) system. As VOC several types of hydrophobic liquid materials were used. After synthesis, the morphology and physicochemical properties of capsules were characterized by electron microscopy, FTIR and DSC/TGA. An encapsulation efficiency up to 90% could be reached. The emission kinetic of volatile agents was studied in emission test chambers at 23 °C and 50% RH for 14 days. First results indicate that variation of the cross-linking grade of the shell material is one important parameter to adjust the desired emission rate. The overall aim is to achieve a consistent emission profile that decreases by less than 10 % over a target period of at least 14 days. T2 - 36th European Colloid & Interface Society Conference CY - Chania, Crete, Greece DA - 04.09.2022 KW - Capsules KW - Volatile organic compound KW - Polymer KW - Material emissions KW - Reference materials PY - 2022 AN - OPUS4-56039 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - New developments in odour testing: Adapter connects emission test chamber and funnel N2 - Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented. The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test. The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far. T2 - CLIMA 2022 The 14th REHVA HVAC World Congress CY - Rotterdam, The Netherlands DA - 22.05.2022 KW - Perceived Intensity KW - Emissionen KW - Geruch KW - Bauprodukte PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556192 DO - https://doi.org/10.34641/clima.2022.168 SP - 1 EP - 5 PB - TU Delft open CY - Delft, Niederlande AN - OPUS4-55619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Brozowski, Frank A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte (Teil II): Anwendung eines Adapters und vereinfachtes Bewertungsverfahren T1 - Further Development of the Odour Measurement Method for Building Products (Part II) N2 - Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt. Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes. N2 - For technical improvement of sample presentation an adapter was developed to connect the emission test chamber with the evaluation funnel and thus enabling a more direct measurement. The analytical measurements demonstrate that the air has a very similar composition sampled at the funnel or in the emission test chamber. The results of the olfactory measurements show overall that the intensities determined using the adapter are often reported as lower. Further investigations have shown that air backflow via the funnel into the sample container of the adapter may be the cause. This has to be avoided in future. Another experimental series was carried out to reduce the measurement effort of evaluation of perceived intensity. Here application of the developed ‘greater than, or less than/equal to’ survey could be helpful. The results of the measurements in the air quality lab and in the frame of a round robin test indicate, that the survey leads to the same evaluation as the more complex determination of perceived intensity with standard method. KW - Geruchsmessung KW - VOC-Emission KW - Bauprodukte KW - Bewertungsverfahren PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549875 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 82 IS - 3-4 SP - 83 EP - 89 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-54987 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Steger, S. A1 - Horn, Wolfgang A1 - Eggert, G. A1 - Krekel, C. T1 - Are cellulose ethers safe for the conservation of artwork? New insights in their VOC activity by means of Oddy testing N2 - Cellulose ethers, like methyl cellulose (MC) or hydroxypropyl cellulose (HPC), are widely used in conservation. They also occur as additives and rheology modifiers in various products like dispersions or gels. Do such products release harmful volatile organic compounds (VOC) during their accelerated aging? A mass testing series utilizing the Oddy test of 60 commercial cellulose ethers ranks the products in safe for permanent use (P, no corrosion), only for temporary use (T, slight corrosion), and unsuitable at all (F, heavy corrosion). Results show that 55% of the products passed the test whereas 33% are for temporary use as slight corrosion occurred on at least one metal coupon and only 11% failed the Oddy test. Raman measurements of the corrosion products identified oxides like massicot, litharge, cuprite, and tenorite among carbonates (hydrocerussite, plumbonacrite), and acetates like basic lead acetate, lead acetate trihydrate as well as lead formate as main phases. For example, commercial, industrial Klucel® G (HPC) scored a T rating through slight corrosion on the lead coupon. Basic lead acetate among other phases indicates the presence of acetic acid. Additional measurements of the sample with thermal desorption GC–MS utilizing the BEMMA scheme confirm the high acetic acid outgassing and reveal the presence of a small amount of formaldehyde. KW - Cellulose ether KW - Corrosion KW - Oddy test KW - VOC KW - BEMMA PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-547591 DO - https://doi.org/10.1186/s40494-022-00688-4 SN - 2050-7445 VL - 10 IS - 1 SP - 1 EP - 12 PB - Springer Open AN - OPUS4-54759 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Further Development of Odour Testing of Building Products – Sample Presentation and Evaluation of Perceived Intensity N2 - Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020. In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results. T2 - 17th International Conference HEALTHY BUILDINGS EUROPE 2021 CY - Online meeting DA - 21.06.2021 KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC KW - Perceived Intensity PY - 2021 SN - 978-82-536-1728-2 VL - 2021 SP - 1 EP - 4 PB - SINTEF Books CY - Oslo, Norwegen AN - OPUS4-54574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Müller, B. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte T1 - Further development of the odour measurement method for building products N2 - Bauprodukte und Einrichtungsgegenstände für Innenräume, wie Bodenbeläge und Wandpaneele, sollen das Wohlbefinden und die Gesundheit der Raumnutzerinnen und -nutzer nicht durch das Ausdünsten von Geruchsstoffen stören. Mit der Geruchsprüfung nach ISO 16000-28 „Innenraumluft - Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ wird der Produktgeruch zu einer messbaren Größe. So kann z. B. die empfundene Intensität, also die Stärke eines Geruchseindruckes, mit Hilfe eines Vergleichsmaßstabes von Probandinnen und Probanden ermittelt werden. Im hier vorgestellten Projekt werden Vorschläge zur Weiterentwicklung der Methode vorgestellt, um im Ergebnis die Reproduzierbarkeit der Messergebnisse weiter zu verbessern. Dabei werden vor allem das Probenpräsentationssystem und die Bewertungsmethodik für die empfundene Intensität bei der Bewertung von Bauprodukten gemäß AgBB-Schema betrachtet, da diese einen wesentlichen Einfluss haben. N2 - Emissions or odours occurring from building products and furnishings for interiors, like floor coverings or wall panels, should not have a negative impact on well-being or health. Odours can be measured applying the standard ISO 16000-28 „Indoor air - Determination of odour emissions from building products using test chambers” It describes among other procedures the assessment of perceived intensi-ty with comparative scale by a group of panellists. In the study presented here, proposals for further technical development of the methodology are discussed to increase the reproducibility of measurement results. The sampling procedure and evaluation method of perceived intensity are investigated in particular because they have a major influence at the assessment of construction products applying the procedure of the Committee for Health Evaluation of Building Products. KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527458 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 81 IS - 3-4 SP - 151 EP - 155 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-52745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Jann, Oliver T1 - Volatile organic compounds from building products - Results from six round robin tests with emission test chambers conducted between 2008 and 2018 N2 - Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well-characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28 % in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51 %. KW - Construction product KW - Emission test chamber KW - Interlaboratory comparison KW - Proficiency testing KW - Rround robin test KW - VOC emission PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-526139 DO - https://doi.org/10.1111/ina.12848 VL - 31 IS - 6 SP - 2049 EP - 2057 PB - Wiley AN - OPUS4-52613 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Klinge, A. A1 - Radeljic, L. A1 - Jann, Oliver T1 - Natural building materials for interior fitting and refurbishment - What about indoor emissions? N2 - Indoor air quality can be adversely affected by emissions from building materials, consequently having a negative impact on human health and well-being. In this study, more than 30 natural building materials (earth dry boards and plasters, bio-based insulation materials, and boards made of wood, flax, reed, straw, etc.) used for interior works were investigated as to their emissions of (semi-) volatile organic compounds ((S)VOC), formaldehyde, and radon. The study focused on the emissions from complete wall build-ups as they can be used for internal Partition walls and the internal insulation of external walls. Test chambers were designed, allowing the compounds to release only from the surface of the material facing indoors under testing Parameters that were chosen to simulate model room conditions. The emission test results were evaluated using the AgBB evaluation scheme, a procedure for the health-related evaluation of construction products and currently applied for the approval of specific groups of building materials in Germany. Seventeen out of 19 sample build-ups tested in this study would have passed this scheme since they generally proved to be low-emitting and although the combined emissions of multiple materials were tested, 50% of the measurements could be terminated before half of the total testing time. KW - Bio-based insulation KW - Earthen building materials KW - Volatile organic compounds KW - Semivolatile organic compounds KW - Radon PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-519634 DO - https://doi.org/10.3390/ma14010234 VL - 14 IS - 1 (Special issue: Measurement of the environmental impact of materials) SP - 234-1 EP - 234-14 PB - MDPI CY - Basel AN - OPUS4-51963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Hahn, Oliver T1 - Neues BAM-Zertifizierungsverfahren für emissionsarme Materialien zum Bau von Museumsvitrinen N2 - Museumsvitrinen sollen Kunst- und Kulturgut „ins rechte Licht“ setzen und vor Diebstahl oder Vandalismus schützen. Vergleicht man historische Schauvitrinen, die zumeist aus einfachen Glasscheiben in Holzrahmungen bestehen, mit heutigen Konstruktionen, lässt sich eine Entwicklung zu hochtechnisierten Gebilden ablesen, die deutlich mehr Ansprüchen genügen müssen als in der Vergangenheit. Zahlreiche Beispiele verdeutlichen, dass Kunstwerke nicht nur außerhalb, sondern auch innerhalb von Museen oder Archiven ungünstigen Umwelteinflüssen ausgesetzt sind. So können Einbauten bzw. Dekorationen in Ausstellungsräumen, Aufbewahrungsbehältnisse in Depoträumen oder Ausstellungsvitrinen flüchtige Substanzen, sogenannte VOCs (Volatile Organic Compounds) freisetzen, die zu irreversiblen Veränderungen an den Objekten führen und diese schädigen. Hierzu zählen organische Säuren, wie Ameisen- oder Essigsäure, aber auch Verbindungen, die Sulfide enthalten. Hier wird die an der BAM entwickelte BEMMA-Bewertungsmethode vorgestellt, die von Museen verwendet werden kann Materialien mit einem geringeren Emissionspotential auszusuchen. KW - Museum KW - VOC-emission KW - BEMMA KW - Vitrine PY - 2020 SN - 2194-3648 VL - 2020 IS - zwei SP - 80 EP - 81 PB - SchmittART CY - Leipzig AN - OPUS4-51489 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - The BEMMA-Scheme helpful for low VOC inside display cases? N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically, air exchange rates are often smaller than 0.1 d-1, which can result in rising concentrations of potential harmful VOC inside of the display cases due to emissions from materials. Especially organic acids, e. g. formic or acetic acid which can emit from e.g. sealing materials or wood-based materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure which is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museums¬ausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Regarding the testing procedure only construction materials were evaluated, not the display cases their self. Micro chambers are used for VOC emission tests of display case construction materials, e.g. plastics, sealing materials, coatings, textiles and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde, piperidine-derivates and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. T2 - Indoor Air Quality in Heritage and Historic Environments CY - Online meeting DA - 12.10.2020 KW - Museum KW - VOC-emission KW - BEMMA KW - Display case PY - 2020 AN - OPUS4-51470 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Müller, B. A1 - de Lima Vasconcelos, S. A1 - Plehn, W. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Sattler, M. T1 - Präzisierung der Geruchsprüfung für Bauprodukte nach DIN ISO 16000-28 – Untersuchung von Vergleichsmaßstäben N2 - Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Geruch KW - Emission KW - Bauprodukte KW - VOC KW - Emissionskammer PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 214 EP - 223 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Selection of low emittiong material for the construction of display cases based on the BEMMA procedure N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. T2 - Materials Testing Symposium CY - New York City, USA DA - 06.11.2019 KW - Museum KW - Emission KW - Dispay case KW - BEMMA KW - VOC PY - 2019 AN - OPUS4-49589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Kunstgüter in Vitrinen: was helfen Materialuntersuchungen gemäß BEMMA-Schema? N2 - Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat. Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor. Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Museum KW - Emission KW - Bauprodukte KW - BEMMA KW - Vitrinen PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 245 EP - 249 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49326 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Kunstgüter in Vitrinen: was helfen Materialuntersuchungen gemäß BEMMA-Schema? N2 - Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat. Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits-anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor. Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Museum KW - Emission KW - Bauprodukte KW - BEMMA KW - Vitrinen PY - 2019 AN - OPUS4-49327 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Aktuelle Ringversuche der BAM zu VOC und Gerüchen N2 - Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren. Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden. Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. Diese Entwicklungen werden hier aufgezeigt. T2 - 26. WaBoLu-Innenraumtage CY - Berlin, Germany DA - 20.05.2019 KW - Geruch KW - Ringversuch KW - Bauprodukte KW - Emission KW - Emissionskammer PY - 2019 AN - OPUS4-49237 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Brosig, L. A1 - Müller, B. A1 - Mertes, A. A1 - de Lima Vasconcelos, S. T1 - Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude – Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht N2 - Menschen, die in der gemäßigten Klimazone leben, verbringen bis zu 90% ihres Lebens in Innenräumen. Deshalb hat das Innenraumklima eine sehr große Bedeutung für deren Wohlergehen, Gesundheit und Leistungsfähigkeit. In Deutschland wird ca. 40% der eingesetzten Primärenergie für das Heizen, Kühlen und Klimatisieren der Innenräume verwendet. Das Forschungsvorhaben hat eine Laufzeit vom Oktober 2013 bis März 2017. Es wird in Kooperation mit der Bundesanstalt für Materialforschung und –prüfung (BAM) und der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) durchgeführt. Die HTW Berlin koordiniert das Projekt. Die Rheinisch-Westfälische Technische Hochschule Aachen (RWTH) wird teilweise über einen Auftrag in das Projekt integriert. Ziel des Projektes ist es Baustoffe auf ihre Geruchsemissionen zu untersuchen, um Bauprodukte mit niedrigen Emissionen und Gerüchen identifizieren zu können. Den Verbraucherinnen und Verbrauchern wird somit die Möglichkeit gegeben emissions- und geruchsarme Baustoffe zu wählen. Die Aufgabenstellung des Projektes ist nachfolgend aufgeführt: Arbeitspaket 1: Geruchsmessung bei Produkten mit dem Blauen Engel (siehe Kapitel 4 und 5); Arbeitspaket 2: Untersuchung von Vergleichsmaßstäben (siehe Kapitel 6); Arbeitspaket 3: Untersuchung der Linearität der Acetonskala (siehe Kapitel 7); Arbeitspaket 4: Erstellung einer Produktdatenbank (siehe Kapitel 8). Die Geruchsuntersuchung ist in den Vergabekriterien für den „Blauen Engel“ für textile Bodenbeläge (RAL UZ-128) eingebunden worden. Aus den weiteren Untersuchungen sind für die Normung wichtige Erkenntnisse erarbeitet worden. KW - VOC Emissionen KW - Geruch KW - Bewertung KW - Innenraumluftqualtität KW - Bodenbeläge PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487223 UR - https://www.umweltbundesamt.de/publikationen/emissions-geruchsarme-bauprodukte-fuer UR - https://www.umweltbundesamt.de/sites/default/files/medien/1410/publikationen/2019-08-20-texte_92-2019_emissionsarme-bauprodukte.pdf SN - 1862-4804 VL - 92 SP - 1 EP - 106 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-48722 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - de Lima Vasconcelos, S. A1 - Sattler, M. A1 - Müller, B. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - The Influence of textile floor coverings on the indoor air quality N2 - Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge). T2 - Clima 2019 Congress CY - Bucharest, Romania DA - 26.05.2019 KW - VOC Emissionen KW - Geruch KW - Bodenbelag KW - AgBB Bewertung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-487341 DO - https://doi.org/10.1051/e3sconf/201911102051 SN - 2267-1242 VL - 111 SP - 02051-1 EP - 02051-6 PB - EDP Sciences AN - OPUS4-48734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Quality Improvement of VOC chamber emission tests observed for 10 years with round robin tests N2 - In Europe, the Construction Products Regulation (CPR, 2011/305/EU) sets basic requirements (BR) on how construction works must be designed and built. BR 3 “hygiene, health and the environment” states low emissions of toxic gases, Volatile Organic Compounds (VOCVOCs), particles, etc. from building materials. Meanwhile, a worldwide network of professional Commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established. Therefore, comparability of test results must be ensured. The participation in Round Robin Tests (RRTRRTs) is a means to prove a laboratory’s proficiency. Since 2006 BAM offers such proficiency test for emission chamber test every two years. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. BAM used different materials over the years. Currently, the best suited reference material is a cured lacquer surface which contained several VOCs added to the liquid lacquer system. The round robin tests 2014, 2016 and 2018 were conducted with such a system. Compounds like Styrene or n-Alkanes like Decane or Tridecane were tested in many of the proficiency test operated by BAM. Up to now the relative standard deviation of these compounds decrease continuously. Starting with values about 30 % in 2008 we reached values for the mentioned compounds 15 to 20 % now. But even for more polar compounds improved results were received. Over the years the results of a large group of laboratories detected many compounds with much higher accuracy than at the beginning. So, the comparability between results of different laboratories becomes much better. T2 - International Conference on Risk Assessment of Indoor Air Chemicals CY - Berlin, Germany DA - 16.09.2018 KW - Chamber test KW - Round robin test KW - VOC-emission PY - 2018 AN - OPUS4-47906 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Mölders, N. A1 - Sauerwald, T. A1 - Schultealbert, C. A1 - Mull, B. T1 - Two new promising approaches for quality assurance measures for materials emissions testing N2 - Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained. T2 - Indoor Air 2018 CY - Philadelphia, PA, USA DA - 22.07.2018 KW - Emission reference material KW - Volatile organic compounds KW - CO2 assisted impregnation KW - FEM model PY - 2018 SP - 1 EP - 8 AN - OPUS4-45610 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Zertifizierung emissionarmer Materialien für Museumsvitrinen N2 - Anregungen aus dem N.i.Ke.-Workshop 2017 und künftige Anforderungen. BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Hier wird der Status-Quo des Erreichten dargestellt. Wie wird das Schema in der Museumsöffentlichkeit wahrgenommen und seine Akzeptanz. T2 - BZS-Beirat CY - BAM, Berlin, Germany DA - 19.01.2018 KW - BEMMA KW - Museumsvitrinen KW - VOC-Emissionen PY - 2018 AN - OPUS4-43860 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - BEMMA als Auswahlkriterium für Vitrinenbaumaterialien N2 - BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Ergebnisse der Untersuchungen seit ca. 2010 bis 2017 werden präsentiert und diskutiert. T2 - Ringvorlesung der HTW Analyse und Wahrnehmung: Kulturgut erforschen und erhalten CY - HTW Berlin, Germany DA - 16.01.2018 KW - Museumsvitrine KW - VOC-Emissionen KW - BEMMA Bewertung PY - 2018 AN - OPUS4-43828 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Messverfahren BEMMA-Schema: Entstehung, Anwendung, Grenzen N2 - Mit dem BEMMA-Verfahren lassen sich flüchtige organische Verbindungen aus modernen Werkstoffen, die in mittel- oder unmittelbarem Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen, untersuchen und bewerten. Das Verfahren wurde im Rahmen eines AIF-Vorhabens und der Untersuchung von über 100 unterschiedlichen Materialien entwickelt. Weiterhin wurden mit den gewonnenen Ergebnissen und einigen zuvor bereits identifizierten Problemstoffen wie Essigsäure, Formaldehyd oder Oxime aus den Vorhabenerkenntnissen Bewertungskriterien erarbeitet. Die Vitrinenbaumaterialien, nicht die Vitrine, werden im Hinblick auf ihre Emissionen bewertet, wobei z. B. Holzwerkstoffe nicht bewertet werden, zumal diese meist mit Formaldehyd ein Emissionsproblem hätten. Der Einsatz von Materialien für Vitrinen, die gemäß BEMMA-Schema getestet wurden und die die Emissionswerte erfüllen, soll die Herstellung möglichst emissionsarmer Vitrinen ermöglichen. Kernstück des BEMMA-Schemas ist die Bewertung aller Messergebnisse gemäß dem im Folgenden dargestellten Untersuchungsablauf: 1. Beladen der µ-Kammer; 2. Probenahme der flüchtigen, kurzkettigen, organischen Säuren (ca. 0,5 bis 1 Stunde nach der Beladung für ca. 20 Stunden, 30 Liter Probenahmevolumen); 3. Probenahme der VOCs mit Tenax® (ca. 10 Minuten, 0,25 Liter Probenahmevolumen); 4. Probenahme Oxime und Piperidin-Derivate† mit Tenax® (ca. 40 Minuten, 1,0 Liter Probenahmevolumen); 5. Probenahme der Aldehyde und Ketone (für ca. 20 Stunden, 30 Liter Probenahmevolumen) Dabei werden 4 Sammlersysteme beladen und anschließend analysiert. Die mit dem BEMMA Schema entwickelten Summenwerte für flüchtige organische Stoffe sind im Wesentlichen vor dem Hintergrund der Emissionsminimierung aufgestellt worden. Es gibt für viele VOC keine eindeutige Wechselwirkung mit den Objekten in der Vitrine, zumal diese auch aus vielen verschiedenen Werkstoffen bestehen können und ein VOC nicht mit all diesen reagieren wird. Grundsätzlich „verdächtig“ sind natürlich alle reaktiven Stoffe, wie z. B. Isocyanate. Diese werden aber aus gut gelagerten oder ausreichend belüfteten Baumaterialien für Vitrinen nicht abgegeben. Anorganische Schadgase können zwar in der Umgebungsluft verstärkt auftreten - sind aber aus Baumaterialien nicht zu erwarten. Daher kann das BEMMA-Schema auch nur für einen Teil der luftgetragenen Schadstoffe eine sinnvolle Aussage treffen. Eines der Probleme bei der Bewertung vieler Kleb-/Dichtstoffe ist die Emission cyclischer Siloxane. Deren Schädigungspotential einzu¬schätzen wäre eine wichtige Aufgabe, um an dieser Stelle mehr Klarheit bei der Bewertung zu bekommen. T2 - Quo vadis BEMMA? Präventive Konservierung CY - BAM, Berlin, Germany DA - 07.09.2017 KW - Vitrinen KW - BEMMA KW - VOC KW - Emissionen PY - 2017 AN - OPUS4-43090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Mull, B. A1 - Richter, Matthias A1 - Brödner, Doris A1 - Mölders, N. A1 - Renner, M. T1 - Reproducibly emitting reference material for quality assurance/quality control of emission test chamber measurements N2 - Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol). T2 - Healthy Buildings 2017 Europe CY - Lublin, Poland DA - 02.07.2017 KW - Emissions testing KW - Volatile organic compounds KW - Polymeric material KW - CO2 assisted impregnation PY - 2017 SN - 978-83-7947-232-1 SP - Paper 0172, 1 EP - 2 AN - OPUS4-42348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mull, Birte A1 - Sauerwald, T. A1 - Schultealbert, C. A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Richter, Matthias T1 - Reproducibly emitting reference materials for volatile and semi-volatile organic compounds—using finite element modeling for emission predictions N2 - Recent research into emissions of (semi-)volatile organic compounds [(S)VOC] from solid materials has focused on the development of suitable reference materials for quality assurance/quality control of emission test chamber measurements, which fulfill requirements such as homogenous and reproducible (S)VOC release. The approach of this study was to find a method for preparation of a material with predictable (S)VOC emission rates. AVOC (styrene) and an SVOC (2,6-diisopropylnaphthalene, DIPN), loaded into either vacuum grease or a 1:1 mixture of paraffin/squalane, have been tested. For the prediction of the emission rates, a model using the finite element method (FEM) was created to simulate the (S)VOC emission profiles. Theoretical and experimental results obtained in a Micro-Chamber/Thermal Extractor (μ-CTE™) and in 24 L emission test chamber measurements were in good agreement. Further properties were investigated concerning the material applicability, such as shelf life and inter-laboratory comparability. The maximum relative standard deviation in the inter-laboratory study was found to be 20%. KW - Emitting reference material KW - Emission test chamber KW - Micro-chamber KW - FEM model PY - 2017 DO - https://doi.org/10.1007/s11869-017-0508-6 SN - 1873-9318 SN - 1873-9326 VL - 10 IS - 10 SP - 1237 EP - 1246 PB - Springer Science+Business Media B.V. AN - OPUS4-41951 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Horn, Wolfgang A1 - Richter, Matthias A1 - Nohr, M. A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Application of a novel reference material in an international round robin test on material emissions testing N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail. KW - Emission test chamber KW - Reference material KW - Round robin test KW - VOC PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-419412 DO - https://doi.org/10.1111/ina.12421 SN - 1600-0668 SN - 0905-6947 VL - 28 IS - 1 SP - 181 EP - 187 PB - Wiley & Sons, Ltd. AN - OPUS4-41941 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Development of gas standards to underpin indoor air measurements N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Webinar “Discussing impact on climate monitoring and indoor air quality measurements For registration press@inrim.it of EMRP KEYVOCs PROJECT” CY - www; webinar DA - 05.09.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Schultealbart, Caroline T1 - Reference materials for round robin tests for emission test chambers – a review N2 - Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks. T2 - Metrologie for indoor air quality CY - Berlin, Germany DA - 29.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41938 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Evaluation of material emissions for museum equipment – BEMMA-Scheme N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. The basic evaluation for the values used for first assessments were a ZIM-project with nearly 100 tested materials. In-between more than 100 new materials were tested and enlarged the knowledge about material emissions from display case materials. Mainly silicone sealing materials were tested due to the fact that this group of material have the highest emissions. With regard to the testing procedure only construction materials were evaluated, not the display cases their self. Nevertheless in combination with the certificate also designed by BAM additionally the further steps of construction can be taken into account. So other factors such as age and storage time of materials, tightness respectively air change rate, air condition or ventilation of display cases can be included in the evaluation. T2 - Airmon: 9th International Symposium on Modern Principles of Air Monitoring and Biomonitoring CY - Dresden, Germany DA - 11.06.2017 KW - Display cases KW - BEMMA KW - Museum KW - Emission KW - VOC PY - 2017 AN - OPUS4-41937 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Possible reference materials for proficiency tests for emission chamber tests N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail. T2 - Airmon: 9th International Symposium on Modern Principles of Air Monitoring and Biomonitoring CY - Dresden, Germany DA - 11.06.2017 KW - Emission test chamber KW - QA/QC KW - Reference material KW - Round robin test KW - VOC PY - 2017 AN - OPUS4-41936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Mölders, N. A1 - Renner, M. T1 - Reproducibly emitting reference material on thermoplastic polyurethane basis for quality assurance/quality control of emission test chamber measurements N2 - Volatile Organic Compounds (VOC) are ubiquitous in the indoor air since they are emitted from materials used indoors. Investigations of these materials are mostly carried out in emission test chambers under controlled climatic conditions. Reference materials are an important tool for quality assurance/Quality control of emission test chamber measurements but so far they are not commercially available. In this study, a new approach was tested to develop an appropriate reference material with homogenous and reproducible emission of the VOC with well measurable air concentrations in emission test Chambers larger than 20 L at air change rates of 0.5 - 1 /h. Thermoplastic Polyurethane (TPU) was selected as Matrix material which was impregnated with 2,2,4- trimethyl-1,3-pentanediol monoisobutyrate (texanol) as test VOC using compressed carbon dioxide. An optimization of the impregnation parameters such as temperature, pressure, time, VOC injection volume and TPU sample size was performed until the targeted area specific Emission rate (SERa) value was reached. Further aspects like process control, storage effects and correlation of the sample size to the emission rate were investigated. It was found that the SERa immediately after sample preparation were not reproducible between the batches but became unified 10 days after loading into the test chamber indicating the necessity of aging before use. SERa between 13,000 and 18,000 mg m-2 h-1 were obtained, and the impregnated materials could be well stored in aluminum-coated polyethylene foil for at least seven weeks without significant losses. Furthermore, the impregnation of styrene and the SVOC 2,6-diisopropylnaphthalene was tested. KW - Reference material KW - Emissions testing KW - Volatile organic compounds KW - Polymer material KW - CO2 assisted impregnation PY - 2017 DO - https://doi.org/10.1016/j.buildenv.2017.06.005 SN - 0360-1323 SN - 1873-684X VL - 122 SP - 230 EP - 236 PB - Elsevier AN - OPUS4-40646 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers T1 - Entwicklung von Referenzmaterialien für Leistungstests bei Emissionskammermessungen N2 - Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT. Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions. The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber. Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results. N2 - Die Untersuchung von Produkten auf deren Emissionseigenschaften ist ein aktuell wachsender Aufgabenbereich für Messinstitute. Label werden für Bauprodukte auf Basis von Emissionskammermessungen vergeben, weshalb die dabei eingesetzten Messmethoden überprüft werden sollten. Ein Ringversuch (RV), bei dem ein homogenes Material von verschiedenen Laboratorien parallel untersucht wird, ist ein geeignetes Verfahren dafür. Für einen solchen Ringversuch aber auch generell für die laborinterne Qualitätssicherung ist es sehr hilfreich ein Referenzmaterial zu haben, um gut vergleichbare Ergebnisse zu erhalten. Generell kann jedes kommerziell erhältliche Produkt als Referenzmaterial verwendet werden, wenn es gut charakterisiert ist. Allerdings emittieren die meisten Produkte nur wenige VOC und diese sind typischerweise sehr materialspezifisch. Die Homogenität der Materialien ist nicht immer gegeben, so ist es besser, nach alternativen Materialien zu suchen. Es sind schon einige Veröffentlichungen zu reproduzierbar emittierenden Materialien verfügbar. Diese enthalten bislang zumeist nur ein einzelnes VOC – Toluol. Im Rahmen von zwei Forschungsvorhaben arbeitet die BAM an der Entwicklung von Referenzmaterialien für Emissionskammer-Untersuchungen, die einzelne VOC oder VOC-Mischungen emittieren. Der erste Ansatz war die Dotierung eines kommerziellen Lackes mit einer VOC/SVOC-Mischung, weitere Untersuchungen werden mit Thermo¬plastischem Polyurethan (TPU) sowie einer Squalan/Paraffin-Mischung durchgeführt. Da mit dem zweiten Ansatz noch Tests laufen, ist damit noch kein RV durchgeführt worden. Wichtige Anforderungen an ein Referenzmaterial sind die Wiederholbarkeit (Homogenität), Reprodu-zierbarkeit und Langzeitstabilität in Bezug auf die VOC-Abgabe und die Transportstabilität. Die Emissionsraten sollten hoch genug sein, um gut messbare Kammerluft-Konzentrationen bei Standardbedingungen zu erhalten. In einen wasserbasierten Lack wurde eine VOC/SVOC-Mischung zugegeben und nach der Durchmischung wurden davon einzelne Portionen in Petrischalen abgefüllt. Diese Schalen wurden unter Standardbedingungen (23 °C und 50% relative Luftfeuchtigkeit) getrocknet. Reproduzierbare Emissionen wurden erhalten, wenn die Lagerzeit ca. vier Wochen nicht überschritten wurde. Die Konzentrationen wurden sieben Tage nach der Beladung der Kammer bestimmt. Zwei RV wurden mit einem wie oben beschriebenen Lacksystem durchgeführt. Es nahmen ca. 50 Labore teil, diese mussten die Zielsubstanzen sowohl identifizieren als auch quantifizieren. Die gefundenen Mittelwerte und Standardabweichungen lagen jeweils im zu erwartenden Bereich für solch einen RV. T2 - Odour and Emission of Plastic Materials CY - Kassel, Germany DA - 21.03.2017 KW - Ringversuch KW - Round robin test KW - Emissionskammer KW - Emission test chamber KW - Referenzmaterial KW - Reference material PY - 2017 AN - OPUS4-40299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Ringversuche zur Bewertung von Geruch bei Bauprodukten N2 - Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren. Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Diese Methode an sich weist zahlreiche Faktoren auf, die das Untersuchungsergebnis beeinflussen können, als da wären die Konstanz der Parameter wie Luftwechselrate, Luftfeuchtigkeit und Temperatur oder die konkrete Präparation der Probe und deren Positionierung in der Kammer etc. Für die Probenahme von flüchtigen organischen Komponenten kommen noch die eher analytischen Faktoren dazu und für die geruchliche Bewertung lassen sich weitere Einflussgrößen identifizieren. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden. Die ersten beiden dieser Ringversuche wurden mit hohem zeitlichen und personellen Aufwand begleitet. So fuhren in 2012 Mitarbeiter der BAM zu den Teilnehmern und begutachteten vor Ort die jeweils vorhandenen Bewertungs-einrichtungen. In 2014 und 2016 wurden jeweils Materialien verschickt, die sowohl eine geruchliche Bewertung als auch für die Bestimmung von VOC in der Prüfkammerluft geeignet waren. Parallel zu den Proben wurden eine sehr konkrete Anweisung verschickt, wie der Ringversuch durchzuführen war und weiterhin sehr ausführliche Fragebögen, deren Ergebnisse z. T. in die Neufassung der ISO-Norm einfließen sollen. Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. T2 - Emissionsarme Bauprodukte und Wohngesundheit CY - Braunschweig, Germany DA - 22.03.2017 KW - Ringversuch KW - Emissionskammer KW - Referenzmaterial KW - Geruch PY - 2017 AN - OPUS4-40298 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Method-verification and optimisation of the standardised assessment of odour intensity regarding ISO 16000-28 N2 - Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons. In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Odour assessment KW - Perceived odour intensity KW - Reference odour KW - Emission testing KW - Building products PY - 2016 SN - 978-0-9846855-5-4 SP - Paper 568, 1 EP - 6 AN - OPUS4-38373 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Sauerwald, T. A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Brödner, Doris A1 - Schultealbert, C. T1 - Development of a reproducibly emitting reference material for volatile organic compounds N2 - The aim of this study is the development of a reproducibly emitting reference material for volatile organic compounds (VOC). The first part of the work was carried out with styrene, for which supporting materials were successfully selected, doped and analyzed in test chambers. T2 - Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate CY - Ghent, Belgium DA - 03.07.2016 KW - Quality control KW - Emission test chamber KW - Indoor air KW - Quality assurance PY - 2016 SN - 978-0-9846855-5-4 AN - OPUS4-36849 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pech, Anja A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Analysis of very volatile organic compounds (VVOC) with thermal desorption GC-MS N2 - Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed. Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions. T2 - Indoor Air 2016, The 14th international conference of Indoor Air Quality and Climate CY - Gent, Belgium DA - 03.07.2016 KW - Thermal desorption KW - VVOC KW - Carbograph 5TD KW - Carbopack X PY - 2016 SP - Paper 889, 1 EP - 2 AN - OPUS4-37035 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Round Robin test for the implementation of odour measurements regarding ISO 16000-28 into the evaluation of buildings products - Part II (Specified by VDI 4302-1) N2 - While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons. KW - Odour measurement KW - Perceived intensity KW - Hedonic tone KW - VOC KW - Building materials PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/round-robin-test-for-the-implementation-of-odour SN - 1862-4804 VL - 79/2015 SP - UBA-FB 002199/E, 1-142 CY - Dessau-Roßlau AN - OPUS4-34886 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung der Geruchsmessungen nach DIN ISO 16000-28 in die Bewertung von Bauprodukten N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessung KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukt PY - 2015 UR - http://www.umweltbundesamt.de/publikationen/ringversuch-zur-einfuehrung-der-geruchsmessungen SN - 1862-4804 VL - 88/2014 SP - UBA-FB 002049, EP - 1-141 CY - Dessau-Roßlau AN - OPUS4-34885 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Juritsch, Elevtheria A1 - Klinge, A. A1 - Roswag, E. A1 - Fontana, Patrick A1 - Miccoli, Lorenzo T1 - Indoor air emission tests of natural materials N2 - Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany. T2 - 1st ICBBM - International conference on bio-based building materials CY - Clermont-Ferrand, France DA - 22.06.2015 KW - Emission testing KW - Natural materials KW - VOC KW - Formaldehyde KW - Radon PY - 2015 SN - 978-2-35158-154-4 SP - 641 EP - 643 AN - OPUS4-33609 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Geruchsprüfungen nach DIN-ISO 16000-28-Grundlagen und Erprobung für den Blauen Engel T2 - 22. WaBoLu-Innenraumtage - Drucker, Gerüche und mehr ... CY - Berlin, Germany DA - 2015-05-12 PY - 2015 AN - OPUS4-33280 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Ringversuche zur Einführung von Geruchsmessungen in die Bewertung von Bauprodukten entsprechend der DIN ISO 16000-28 und VDI 4302-1 N2 - The DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable. To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014. The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showed Standard deviations of reproducibility between 20 and 40%. Standard deviations of reproducibility of well-established interlaboratory tests for VOCs show comparable results. T2 - 17. Workshop - Geruch und Emissionen bei Kunststoffen CY - Kassel, Germany DA - 16.03.2015 PY - 2015 SP - 8-1 EP - 8-9 AN - OPUS4-33075 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nohr, Michael A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Richter, Matthias A1 - Lorenz, W. T1 - Development of a multi-VOC reference material for quality assurance in materials emission testing N2 - Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved. KW - Reference material KW - Emission KW - Emission test chamber KW - Micro-chamber KW - VOC PY - 2015 DO - https://doi.org/10.1007/s00216-014-8387-2 SN - 1618-2642 SN - 1618-2650 VL - 407 IS - 11 SP - 3231 EP - 3237 PB - Springer CY - Berlin AN - OPUS4-32404 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, B. A1 - Panasková, J. A1 - Müller, D. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Scutaru, A.M. A1 - Plehn, W. T1 - Entwicklungen der Bewertungsmethodik von Gerüchen in Innenräumen N2 - Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen. KW - Geruch KW - Innenraum KW - Bauprodukte KW - Bewertung PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 70 EP - 82 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-32403 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Pech, Anja A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Determination of methanol and ethanol in test chamber air by using TDS-GC-FID N2 - A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber. T2 - Indoor Air 2014 - 13th International conference on indoor air quality and climate CY - Hong Kong, People's Republic of China DA - 07.07.2014 KW - Methanol KW - Ethanol KW - VVOC KW - Thermal desorption KW - Carbotrap 300 PY - 2014 SP - B6-HP0620, 1-2 AN - OPUS4-32323 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Investigations on the emissions of biocides and PCBs under low volume conditions N2 - The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB 28 and PCB 153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27 L test showcases and 23 L and 24 L emission test chambers and also diffusive sampling with glass as the sampling material. KW - SVOC KW - Emission test chamber KW - Showcase KW - SDVB-polymer PY - 2015 DO - https://doi.org/10.1016/j.chemosphere.2014.06.021 SN - 0045-6535 SN - 0366-7111 VL - 118 SP - 65 EP - 71 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-32140 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Ringversuch zur Einführung von Geruchsmessungen in Anlehnung an ISO 16000-28 N2 - Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten. KW - Geruchsmessungen KW - Empfundene Intensität KW - Hedonik KW - VOC KW - Bauprodukte PY - 2014 SN - 2195-643X VL - 135 IS - 2 SP - 84 EP - 90 PB - DIV Deutscher Industrieverlag GmbH CY - München AN - OPUS4-31391 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver T1 - Applicability: Odour measurement based on ISO 16000-28 - enhanced determination of indoor air quality N2 - Odours might cause offensive nuisance and are under suspicion to be directly harmful to health. Surprisingly their assessment is by definition no part of the determination of indoor air quality (yet). As odours emit from building materials as well as from common consumer goods the users awareness increases continuously and demand for improved consumer protection raises. In comparison to well established methods for the determination of volatile organic compounds (VOC) in the air, there is little experience regarding the applicability, comparability and reproducibility of odour measurements. Considering this, the international and the German standardisation take into account odour assessment, e.g. ISO 16000-28 and VDI 4302-1. In Germany the AgBB-Scheme is a mandatory tool for the evaluation of building products and it is intended to implement odour measurement into it. Initially and essentially the newly developed method had to be put to test involving institutes that deal with VOC measurements. To test the applicability of the method an interlaboratory test was conducted. The results and identified potential improvements are presented in this study (Brosig, 2013). T2 - Indoor Air 2014 - 13th International conference on indoor air quality and climate CY - Hongkong, China DA - 07.07.2014 KW - Odour measurement KW - Perceived intensity KW - Hedonic tone KW - VOC KW - Building materials PY - 2014 SP - HP1079, 1 EP - 4 AN - OPUS4-31390 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Emissions from products into indoor air: Important factors for interlaboratory studies with emission test chambers T2 - Airmon - 2014 CY - Marseille, France DA - 2014-06-14 PY - 2014 AN - OPUS4-30932 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nohr, Michael A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Richter, Matthias A1 - Lorenz, W. T1 - Development of a material with reproducible emission of selected volatile organic compounds - mu-chamber study N2 - Volatile organic compounds (VOCs) found indoors have the potential to affect human health. Typical sources include building materials, furnishings, cleaning agents, etc. To address this risk, chemical emission testing is used to assess the potential of different materials to pollute indoor air. One objective of the European Joint Research Project 'MACPoll' (Metrology for Chemical Pollutants in Air) aims at developing and testing a reference material for the quality control of the emission testing procedure. Furthermore, it would enable comparison of measurement results between test laboratories. The heterogeneity of the majority of materials makes it difficult to find a suitable reference sample. In the present study, styrene, 2-ethyl-1-hexanol, N-methyl-α-pyrrolidone, lindane, n-hexadecane, 1,2-dimethyl- and 1,2-di-n-butyl-phthalate were added to 12 commercially available lacquers (6 alkyd and 6 acrylic polymer based lacquers) serving as carrier substrate. After homogenization, the mixtures were loaded into a Markes Micro-Chamber/Thermal Extractor (µ-CTE™) for curing and investigation of the emission behavior for each compound. For almost all of the investigated chemicals, the preferred glossy acrylic lacquer showed emissions that were reproducible with a variation of less than 20% RSD. Such lacquer systems have therefore been shown to be good candidates for use as reference materials in inter-laboratory studies. KW - VOC KW - Reference material KW - Emission testing KW - Indoor air KW - Inter-laboratory study PY - 2014 DO - https://doi.org/10.1016/j.chemosphere.2013.12.047 SN - 0045-6535 SN - 0366-7111 VL - 107 SP - 224 EP - 229 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-30816 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pech, Anja A1 - Wilke, Olaf A1 - Mull, Birte A1 - Horn, Wolfgang A1 - Jann, Oliver T1 - Development of a TDS-GC-FID method for the determination of methanol and ethanol in air N2 - A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber N2 - Eine Methode zur Bestimmung von sehr leicht flüchtigen Verbindungen in Luft wurde für Methanol und Ethanol entwickelt und erfolgreich getestet. Dafür wurde Carbotrap300® (Multibettrohr aus Carbopack C®, Carbopack B® und Carbosive SIII®) als Sorptionsmedium für die Thermodesorption ausgewählt und dessen Eignung für Emissionskammermessungen untersucht. Das Adsorptionsverhalten und die chromatographischen Ergebnisse werden negativ durch die Aufgabe von wässrigen Kalibrierlösungen auf das Adsorptionsmedium beeinflusst. Durch das Überleiten von trockener Luft kann dieser Effekt verringert werden, da so das adsorbierte Wasser entfernt wird. Die Nachweis- und Bestimmungsgrenzen wurden für ein eingesetztes GC- FID-System ermittelt und mit einem GC-MS verglichen. Mit einem methanolabspaltenden silanmodifizierten Polymerklebstoff (SMP-Parkettkleber), der in eine Emissionskammer eingebracht wurde, konnte die Tauglichkeit der Methode überprüft werden. PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-297020 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=76019 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 73 IS - 11/12 SP - 477 EP - 482 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-29702 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Generation of reproducible chamber concentrations for round robin tests based on reference materials T2 - Emission and Odours from Materials - 2013 CY - Brussels, Belgium DA - 2013-10-17 PY - 2013 AN - OPUS4-29629 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brosig, Laura A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Jann, Oliver A1 - Plehn, W. T1 - Round robin test for the implementation of odour measurements according to DIN ISO 16000-28 into the assessment of emissions from building products N2 - Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made. N2 - Im Rahmen der Bewertung von Innenraumluftqualität und von Emissionen aus Bauprodukten gewinnt auch die Beurteilung entstehender Gerüche zunehmend an Bedeutung. Um der daraus resultierenden Forderung nach Geruchsbewertungen gerecht zu werden, müssen entsprechende Methoden in bestehende Bewertungssysteme, wie z. B. das AgBB-Schema, aufgenommen werden. Als Grundlage hierfür bieten sich die bereits bestehenden Regelwerke DIN ISO 16000-28 und VDI 4302 Blatt 1 an, die das Vorgehen bei Geruchsmessungen unter Verwendung eines Vergleichsmaßstabes vorgeben. Da für die beschriebene Methode bisher keine Validierung vorliegt, wurde 2012 ein Ringversuch mit zwölf Instituten durchgeführt, der sich hauptsächlich aus zwei Teilen zusammensetzte: 1) Überprüfung der technischen Funktionsfähigkeit der verwendeten Vergleichsmaßstäbe und 2) Durchführung einer Geruchsbewertung für eine Acryldichtmasse mithilfe von Emissionsprüfkammern. Im ersten Teil wurden sowohl die Volumenströme als auch die bereitgestellten Konzentrationen der Referenzsubstanz Aceton bestimmt. Der zweite Teil diente neben der Ermittlung der Leistungsfähigkeit der Laboratorien vor allem der Feststellung, inwieweit eine Bestimmung der empfundenen Intensität und der Hedonik nach DIN ISO 16000-28, ergänzt durch VDI 4302 Blatt 1, einheitlich möglich ist. Aus Gründen der Vergleichbarkeit und der Qualitätskontrolle wurden am siebten Tag der Messungen zusätzlich Proben der Prüfkammerluft zur VOC-Bestimmung genommen. Mithilfe des Ringversuchs konnten Defizite sowohl technischer als auch methodischer Art festgestellt und Vorschläge für die Verbesserung des Vorgehens bei Geruchsbewertungen erarbeitet werden. PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-293110 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=75118 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 73 IS - 10 SP - 441 EP - 445 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-29311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Erfassung der Zahl feiner und ultrafeiner Partikel aus Bürogeräten während der Druckphase zur Entwicklung eines Prüfverfahrens für das Umweltzeichen Blauer Engel für Bürogeräte mit Druckfunktion KW - Bürogeräte KW - Laserdrucker KW - Partikelemissionen PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/erfassung-zahl-feiner-ultrafeiner-partikel-aus SN - 1862-4804 VL - 74 IS - FKZ/Projektnr. 3708 95 301 UBA-FBNr. 001743 SP - 1-146, Anh. 1-39 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28988 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Measurement of fine and ultrafine particles from office devices during printing in order to develop a test method for the Blue Angel ecolabel for office-based printing devices N2 - The research project on which this report is based focuses on the measurement of particulate emissions in the area of fine and ultrafine particles from laser printing devices. Against the backdrop of a public debate about possible hazards related to these emissions, ⁠UBA⁠ has commissioned BAM to develop a measurement method for these emissions, to expand the existing awarding criteria for the "Blue Angel" ecolabel by the aspect of particle emissions and to physically and chemically analyse particulate emissions. The resulting awarding criteria will be submitted to RAL later this year. ⁠Emission⁠ characteristics of laser printing devices, conclusions on awarding criteria and interim results of the project were discussed in three sessions of a project-related expert group. KW - Bürogeräte KW - Laserdrucker KW - Partikelemissionen PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/measurement-of-fine-ultrafine-particles-from-office SN - 1862-4804 VL - 75 IS - UBA-FBNr: 001743/E / FKZ: 3708 95 301 SP - 1-142, Suppl.RAL-UZ-122 1-39 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28987 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Evaluation of the Odour of Construction Products According to ISO 16000-28 - a first Laboratory Comparison Test T2 - Odour and Emissions of Plastic Materials CY - Kassel, Germany DA - 2013-03-18 PY - 2013 AN - OPUS4-28201 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mull, Birte A1 - Wiegner, Katharina A1 - Horn, Wolfgang T1 - A low-volume air sampling method for biocides and PCBs in a micro-chamber N2 - Since semi-volatile organic compounds (SVOCs), including biocides and polychlorinated biphenyls (PCBs), occur indoors as well as outdoors, air sampling adsorbents and measuring methods for all these compounds are indispensable. This paper presents the initial steps in the development of such a method, the aim of which is the analysis of selected compounds in the above-mentioned classes using low air sampling volumes and air-exchange rates close to zero, as is common in museum showcases. For measurements under easily controlled conditions, a micro-chamber system was used at different temperatures. A surface modified styrene divinylbenzene (SDVB) polymer was selected as the air sampling adsorbent for the elution experiments. After successfully performing pretests using the micro-chamber system with target compound solutions, the emissions of these compounds from self-soaked wood samples and con-taminated wood samples were investigated for method development. KW - Micro-chamber KW - PUF KW - SDVB polymer KW - SVOC PY - 2013 SN - 1018-4619 VL - 22 IS - 3 SP - 675 EP - 680 PB - PSP, Parlar Scientific Publ. CY - Freising AN - OPUS4-27910 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Pyza, Lars A1 - Wilke, Olaf T1 - System to generate stable long-term VOC gas mixtures of concentrations in the ppb range for test and calibration purposes N2 - The development of a gas mixing system (GMS) that enables dynamic and retraceable production of stable long-term VOC gas mixtures within the ppb range is discussed. In this system pure liquid substances are kept separately at a constant temperature, evaporated according to their vapour pressure and removed by a small inert gas flow. A modular set-up allows flexible handling. All vapours generated are finally united in a mixing chamber. Any concentration level of the gas mixture can be produced by a suitable combination of evaporation temperature, carrier and dilution gas flows. Test results from continuous operation over six weeks are presented. The equipment was tested on seven volatile organic compounds (VOC) of different vapour pressure ranges. It was possible to establish stable operation for the equipment during the entire period and reproducible gas concentrations which were traceable to the mass as an SI unit, thus the system is suitable for long-term tests.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Im Beitrag wird die Entwicklung eines Gasmischsystems (GMS) beschrieben, das die dynamische und rückführbare Generierung von langzeitstabilen VOC-Gasgemischen im ppb-Bereich erlaubt. Dabei werden Reinsubstanzen separat temperiert, ihrem Dampfdruck entsprechend verdampft und durch einen kleinen Inertgasstrom abgeführt. In einer Mischkammer werden sie schließlich zusammengeführt. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Aus einem Dauerbetrieb von sechs Wochen werden Untersuchungsergebnisse gezeigt. Dabei wurde die Apparatur mit insgesamt sieben flüchtigen organischen Verbindungen (VOC) unterschiedlicher Dampfdruckbereiche betrieben. Die Anlage lief über den gesamten Zeitraum stabil und lieferte reproduzierbare und auf die Masse als SI-Einheit rückführbare Gaskonzentrationen. Somit ist das Verfahren für Langzeitanwendungen geeignet. KW - Gas mixing system KW - VOC gas mixtures KW - Low gas concentrations KW - Evaporation KW - Dynamic gas generation PY - 2013 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 73 IS - 3 SP - 103 EP - 106 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-27903 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mull, Birte A1 - Wiegner, Katharina A1 - Horn, Wolfgang T1 - Comparison of different air sampling adsorbents for a screening method for SVOC N2 - Semi volatile organic Compounds (SVOC) might be a problem for the indoor air quality among others in older wood based houses and in museums because of the former use of Wood preservatives. Wood preservatives containing biocides were partially applied in the second part of the 20th Century to protect wooden elements in houses and organic exhibits against insect attacks (Leihe 1992; Schieweck et al. 2009). For that reason measurement strategies for wooden elements in emission test chambers, exhibits in museum showcases and for theindoor air are required. The presented data were received from a study in which an analytical method for emission test chamber and Showcase measurements should be developed. Until now starting tests were performed in a Micro� Chamber (p-CTE), and in indoor air. First of all an appropriate adsorbent for the sampling of biocides had to be selected, which extraction process is not that time and solvent consuming as it is for polyurethane foam (PUF). The p-CTE is chosen for the experiments in this study due to its Operation ränge from ambient temperature up to 120 °C. To shorten the sampling time higher temperatures are necessary to force the vaporization of the higher boiling SVOC into the gas phase, because the air sampling of biocides at ambient temperature in emission test chambers can last up to several years (Horn et al. 2003). T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Biocides KW - Air sampling KW - Micro-chamber KW - SDVB-polymer PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (6B.2) AN - OPUS4-27569 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nohr, Michael A1 - Wiegner, Katharina A1 - Richter, Matthias A1 - Horn, Wolfgang T1 - Development of a reference material for the measurement of (S)VOC in emission test chambers N2 - Generally most of the daily time citizens in western countries spend indoors (Brasche and Bischof, 2005). Several investigations Show that harmful (semi-) volatile organic Compounds ((S)VOC) can emit from fumiture and building products into indoor air. Additionally, a significant impact of (S)VOC on the human health is also given (Boeglin et al., 2005). To assess the health impact and air quality, reliable and significant measurements and analytical procedures for the detection of contaminants in indoor air are necessary. Several studies show that the results from inter-Iaboratory round robin test for such (S)VOC measurements show considerable variations up to 300 % (Howard-Reed et al., 2007). Therefore standardisations of Methods for sample preparation, air sampling and for the measurement of (S)VOC emissions are important to get reproducible results. MACPoll (Metrology for Chemical pollutants in air) is one section ofthe environment call of EMRP (European Metrology Research Projekt) and aims to improve the analysis of gaseous pollutants in air. By investigate the traceability for the measurement of (S)VOC in indoor air one part of this project deals with the addressed problems. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - VOC KW - Sources/emissions KW - Measurements KW - Laboratory studies PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (5B.10) AN - OPUS4-27568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Stephan, Ina A1 - Nohr, Michael A1 - Horn, Wolfgang T1 - Development of methods for testing of microbiological contamination of small climate control units for air in display cases N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is operated. Typically air exchange rates are often smaller than 0.1 d'1 (Torge, 2000). Furthermore display cases are often operated with constant temperature and relative humidity. A relative humidity for parchment, leather, wooden sculptures of e.g. 60 % (Stolow, 1988) is suited for the protection of exhibits against external influences like fluctuation of humidity and temperature. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Microbiological contamination KW - Acetic and formic acid KW - Conductivity KW - Climate control device KW - Display case KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (5H.2) AN - OPUS4-27562 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Panaskova, J. A1 - Müller, D. A1 - Plehn, W. T1 - Sensory tests for building materials and rooms - Status of the standardisation N2 - To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany mandatory “Principles for the health assessment of construction products used in interiors” have also been applied for the technical approval of floor coverings since 2004. All of these both voluntary and mandatory Systems combine measurements of volatile organic compounds according to ISO 16000-9 and sensory evaluations (new ISO 16000-28). In this paper a German project financed by the Umweltbundesamt (Federal Environmental Agency) will be presented. The project deals with the questions of how to combine the emission tests with the sensory evaluation and what the best sensory evaluation procedure is for achieving valid and accurate results. The limited values and the evaluation methods will be presented and discussed. In the next Step the criteria for labelling those products without an unpleasant odour will be determined. The current Status of ISO 16000 - 28 and 30 will be also presented. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Sensory evaluation of building materials and rooms KW - Perceived air quality KW - Standardisation KW - Label KW - Normung KW - Geruch KW - Messmethoden KW - Emissionsmessung KW - Bauprodukte PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 6 (3E.5) AN - OPUS4-27561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Kalus, Sabine A1 - Jann, Oliver T1 - Different possibilities for the statistical evaluation of round robin tests for volatile organic compounds in emission test chambers N2 - Emission testing of products is currently a rapidly increasing field of activity. The amounts of volatile organic compounds (VOC) which emit from products in emission test Chambers are used to evaluate these products. Typically labelling procedures for construction products are based on emission test chamber measurements. This performance should be verified. Possibly this can be performed due to testing of one material at different laboratories within a round robin test. Therefore it is necessary that a reference material exists which can be used for such round robin tests or as part of the quality management System to ensure comparable results. The different Statistical evaluation possibilities of a round robin test with a constant reference material for VOCs (volatile organic compounds) in emission test Chambers are the main focus of the presented paper. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Reference material KW - Round robin test KW - Emission test chamber KW - VOC-emission KW - Product emission testing PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (8B.6) AN - OPUS4-27526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Farke, M. A1 - Hahn, Oliver T1 - Assessment of emissions from materials for museum equipment N2 - Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d'1 (Torge, 2000), which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects, as shown in Figure 1. To minimize such risks emissions must be reduced. T2 - Healthy Buildings 2012 - 10th International conference CY - Brisbane, Australia DA - 08.07.2012 KW - Assessment of emissions from materials for museum equipment KW - BEMMA display case KW - Protection of cultural object KW - Emissions PY - 2012 SN - 978-1-921897-40-5 SP - 1 EP - 2 (7G.3) AN - OPUS4-27525 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Barthel, Mathias A1 - Seeger, Stefan A1 - Rothhardt, Monika A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Juritsch, Elevtheria A1 - Hahn, Oliver A1 - Jann, Oliver T1 - Erfassung der Zahl feiner und ultrafeiner Partikel aus Bürogeräten während der Druckphase zur Entwicklung eines Prüfverfahrens für das Umweltzeichen Blauer Engel für Bürogeräte mit Druckfunktion (UFOPLAN 370895301) N2 - Das diesem Bericht zugrundeliegende Forschungsvorhaben konzentriert sich auf die Erfassung partikulärer Emissionen im Fein- und Ultrafeinstaubbereich aus Bürogeräten mit Laserdruckfunktion. Vor dem Hintergrund einer öffentlichen Diskussion über mögliche, mit diesen Emissionen verbundene Gefahren wurde die BAM vom ⁠UBA⁠ damit beauftragt, eine Messmethode für diese Emissionen zu entwickeln, die bestehende Vergabegrundlage für das Umweltzeichen „Blauer Engel“ um den Aspekt Partikelemission zu erweitern und die partikulären Emissionen physikalisch und chemisch zu analysieren. Eine daraus resultierende Vergabegrundlage wird dem RAL zur Vorbereitung einer Expertenanhörung mit den interessierten Kreisen in diesem Jahr vorgelegt werden. KW - Bürogeräte mit Laserdruckfunktion KW - Feine und ultrafeine Partikel KW - Chemische Emissionen KW - Blauer Engel PY - 2013 UR - http://www.umweltbundesamt.de/publikationen/erfassung-zahl-feiner-ultrafeiner-partikel-aus SN - 1862-4804 SN - 0722-186X IS - 74 SP - 1 EP - 189 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-27523 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Development of a reference for the measurement of S(VOC) in Emission test chambers T2 - Healthy Buildings 2012, 10th International Conference CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-27494 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Sensory tests for buildings materials and rooms -Status of the standardisation- T2 - Healthy Buildings 2012, 10th International Conference CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-27493 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Different Possibilities for the Statistical Evaluation of Round Robin Tests for Volatile Organic Compounds in Emission Test Chambers T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26230 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Assessment of Emissions from Materials for Museum Equipment T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26229 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - Developement of methods for testing of microbiological contamination of small climate control units for air in display cases T2 - Healthy Buildings 2012 CY - Brisbane, Australia DA - 2012-07-08 PY - 2012 AN - OPUS4-26228 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Den Schadstoffen auf der Spur - Die Bewertung von Emissionen aus Materialien für Museumsausstattungen mithilfe des neuen BEMMA-Schemas N2 - Ausstellungskuratoren, Restauratoren oder Fachplaner stehen immer wieder vor der Entscheidung, geeignete Materialien für Museumsausstattungen auswählen zu müssen. Vitrinen, Depoteinrichtungen, aber auch Transportverpackungen für Kunst- und Kulturgut sollten unbedingt frei von Schadstoffen sein. Ein neues Verfahren ermöglicht nun eine problemorientierte Untersuchung und Bewertung von Materialien mit belastbaren und reproduzierbaren Ergebnissen. KW - BEMMA KW - Emissionsarme Vitrine KW - Schadstoffe PY - 2012 SN - 0933-4017 VL - 3 SP - 38 EP - 44 PB - Callwey CY - München AN - OPUS4-25794 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Horn, Wolfgang A1 - Farke, M. A1 - Kalus, Sabine A1 - Nohr, Michael A1 - Jann, Oliver T1 - Determination of formic and acetic acid emissions in indoor air or from building products N2 - Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography – mass spectrometry/mass spectrometry). N2 - Viele Konstruktions- und Baumaterialien, wie Holz, Kleber und Anstriche, sind mögliche Quellen für leicht flüchtige organische Verbindungen (VVOC) und flüchtige organische Verbindungen (VOC), wie Ameisen- und Essigsäure. Bedingt durch die hohe Dichtigkeit und den damit verbundenen niedrigen Luftwechsel in neuen Gebäuden können die Konzentrationen dieser gesundheitsgefährdenden Substanzen beträchtlich ansteigen. Um das Risiko zu minimieren, sollen Emissionen aus Bauprodukten identifiziert und quantifiziert werden. Mit der üblichen Standardmethode, die auf einer Luftprobenahme auf Tenax® und anschließender Analyse mittels GC-MS basiert, können diese Säuren nicht ausreichend detektiert werden. Ziel dieser Arbeit ist der Vergleich von zwei unterschiedlichen Methoden zur Bestimmung von Essig- und Ameisensäure. Die Luftprobenahme der ersten Methode, die üblicherweise zur Identifizierung und Quantifizierung von VOC genutzt wird, wurde gemäß ISO 16000-6 and ISO 16017-1 auf Carbotrap® 202, ein mit mehreren Adsorbentien gepacktes Thermodesorptionsrohr, mit anschließender Identifikation und Quantifizierung mittels GC-MS durchgeführt. Die zweite Methode basiert auf einer Luftprobenahme mittels 2,4-Dinitrophenylhydrazin-(DNPH)-Kartuschen, Derivatisierung, Elution, Identifikation und Quantifizierung der Derivate mit LC-MS/MS (Flüssigkeitschromatographie – Massenspektometrie/Massenspektometrie). KW - Formic acid KW - Acetic acid KW - VVOCs KW - Air sampling KW - DNPH PY - 2012 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-255911 UR - http://www.gefahrstoffe.de/gest/article.php?data[article_id]=65887 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 72 IS - 3 SP - 84 EP - 88 PB - Springer-VDI-Verlag CY - Düsseldorf AN - OPUS4-25591 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wiegner, Katharina A1 - Farke, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Hahn, Oliver ED - Brozio, P. T1 - Schadstoffe im Museum richtig einschätzen N2 - Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen. KW - Emissionsarme Vitrinen KW - Präventive Konservierung KW - VOC KW - BEMMA PY - 2011 SN - 978-3-7667-1962-1 SP - 127 EP - 131 PB - Callwey CY - München AN - OPUS4-25377 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Müller, Birgit A1 - Müller, D. A1 - Horn, Wolfgang A1 - Panasková, J. A1 - Plehn, W. T1 - Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum T1 - Measurement and evaluation of odour emissions from building products for indoor usage N2 - Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum gewinnen vor allem durch den zunehmenden Bau energieeffizienter Gebäude an Bedeutung. Intensive und unangenehme Gerüche werden von Bewohnerinnen, Bewohnern und Angestellten nicht akzeptiert und können auf Dauer krank machen. Bislang stand noch kein allgemein anerkanntes Messverfahren zur Verfügung. Dieses wurde nun in Forschungsprojekten entwickelt, wobei auch konkrete Bewertungsvorschläge zur Zumutbarkeit von Gerüchen gemacht wurden. Das Verfahren ist an die Messung der Emissionen flüchtiger organischer Verbindungen aus Bauprodukten gekoppelt und nutzt Probanden, um die Geruchsstärke (Intensität) und den Geruchseindruck (Hedonik) zu ermitteln. In der Praxis wird das Verfahren nun an verschiedenen Stellen erprobt. Die Bewertung der Geruchsemissionen gibt der Industrie die Möglichkeit, geruchsarme Produkte zu gestalten. Die Kennzeichnung geruchsarmer Bauprodukte mit dem Umweltzeichen Blauer Engel erleichtert Verbraucherinnen und Verbrauchern die Orientierung beim Einkauf. N2 - Measuring and evaluating odour emissions from building products used in indoor spaces are becoming increasingly important for the construction of energy-efficient buildings. Intensive and unpleasant smells are not accepted by inhabitants and employees and may lead to negative health effects. Up to now a consistent measuring method for odour emissions has not been available. A measuring method and also concrete standards for the assessment of odours by using reasonableness of smells have now been developed in succeeding research projects. The procedure uses a panel of test persons to determine the strength (intensity) and impression (hedonic appraisal) of odour and is linked to the already well established measurement of the emission of volatile organic compounds from building products. At the Moment the new procedure is tested in practice at different laboratories. Evaluating odour emissions helps manufacturers to develop products with low or very low odour emissions. The labeling of low-odour Building products with the environmental label Blue Angel gives consumers an orientation for purchase. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen PY - 2011 SN - 2190-1120 SN - 2190-1147 VL - 4 SP - 50 EP - 58 PB - BfS CY - Berlin AN - OPUS4-25210 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensory-based evaluation of building product emissions - Integration into the Blue Angel award criteria and assessment scheme of the Committee for Health Evaluation of Building Products (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures. These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel. The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample. For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value. KW - Labelsysteme KW - VOC KW - Geruch KW - Geruchstest KW - Emissionsmessungen KW - Building product KW - Directive KW - Health care KW - Pollutant KW - Test method KW - Hydrocarbon KW - Testing using sensors KW - Emission KW - Emission test chamber KW - Odour KW - AgBB scheme KW - Health assessment KW - Assessment procedure KW - Volatile organic compounds KW - Very volatile organic compounds KW - VVOC KW - Semi volatile organic compounds KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Floor coverings KW - Coverings KW - Blue Angel KW - Odour evaluation KW - Acceptability KW - Perceived intensity KW - Hedonic KW - Reasonability KW - Standardization KW - Environmental sign KW - Volatile emission KW - Product labelling PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensory-based-evaluation-of-building-product SN - 1862-4804 IS - 61 SP - 1-133, Annex 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-25200 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, B. A1 - Panasková, J. A1 - Danielak, M. A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Müller, D. T1 - Sensorische Bewertung der Emissionen aus Bauprodukten - Integration in die Vergabegrundlagen für den Blauen Engel und das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten (UBA-FB 001500 / Förder-Kennz. 370762300) N2 - Emissionen aus Bauprodukten beeinträchtigen die Qualität der Innenraumluft erheblich. Mit Hilfe des AgBB-Schemas werden die Emissionen flüchtiger organischer Verbindungen (VOC) aus Bauprodukten bewertet. Die gesundheitliche Bewertung nach dem AgBB-Schema erfordert produktspezifische Messverfahren. Diese gibt es mittlerweile für eine Reihe von Produkten. Sie wurden durch Beteiligung verschiedener Forschungseinrichtungen und Messinstitute validiert und u. a. in die Vergabekriterien des Umweltzeichens Blauer Engel übernommen. Die Bewertung ist allerdings –mit zumeist niedrigeren Grenzwerten –strenger. VOC-Emissionen und Gerüche können beide zu gesundheitlichen Belastungen führen. So ist die sensorische Prüfung ein weiteres wichtiges Element bei der Bewertung von Bauprodukten und vorsorglich auch im AgBB-Schema verankert. Hauptziel des Projektes ist es, eine Methode der sensorischen Bewertung und Grenzen für die Vergabe des Blauen Engels und für das AgBB-Schema abzuleiten. Auf Grundlage der durchgeführten Untersuchungen (siehe Kapitel 5 Ergebnisse und Diskussion) wird als Bewertungsmethode die empfundene Intensität und die Hedonik vorgeschlagen. Die Ableitung der Grenzwerte für die sensorische Bewertung am 28. Tag erfolgt über die zusätzliche Befragung der Probanden im Rahmen der vorliegenden Studie nach der Zumutbarkeit einer Probe. Für den Blauen Engel könnte es je Produktgruppe unterschiedliche Grenzen der empfundenen Intensität und der Hedonik geben. Ein erster Vorschlag für mögliche Grenzen, hier zunächst einheitlich für alle Produktgruppen, ist für die empfundene Intensität 7 pi (5 pi + 2 pi als Sicherheit, Kapitel 5.1.5) und für die Hedonik -1 (0 +/-0,8, gerundet auf -1) (siehe dazu Abbildung 6-2). KW - Bauprodukt KW - Schadstoff KW - Prüfverfahren KW - Blauer Engel KW - SVOC KW - Flüchtige Emission KW - Kohlenwasserstoff KW - Geruch KW - Sensorik KW - AgBB-Schema PY - 2011 UR - http://www.umweltbundesamt.de/publikationen/sensorische-bewertung-emissionen-aus-bauprodukten SN - 1862-4804 IS - 35 SP - 1-146, Anhang 1-109 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-24926 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Horn, Wolfgang A1 - Stephan, Ina A1 - Nohr, Michael A1 - Lau, Angelika A1 - Farke, M. A1 - Hahn, Oliver T1 - Überprüfung möglicher mikrobieller Belastungen in Vitrinenluft durch Kleinklimageräte N2 - Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen. KW - MVOC (microbial volatile organic compounds) KW - Schimmelpilze KW - Kleinklimagerät KW - Vitrinen KW - Essigsäure PY - 2011 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 71 IS - 9 SP - 378 EP - 381 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-24340 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang T1 - European Test Method Validation Approaches T2 - NIST/Virginia Tech Workshop: Reference Material Development for Product Emissions Testing CY - Gaithersburg, MD, USA DA - 2011-04-28 PY - 2011 AN - OPUS4-23913 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Horn, Wolfgang A1 - Wiegner, Katharina T1 - Inter-laboratory study to check the performance ot test chamber measurements for product emission testing N2 - The labelling of construction products or building materials as “low-emitting” is based on measurements using third-party emission test chambers. Unfortunately there is no method to validate the performance of such test chamber measurements. This might give a Variation of results when testing one material at different laboratories. Therefore it is necessary to hold round robin tests as part of the quality management System to ensure comparable results. A research project financed by the Federal Environmental Agency focused on the development of an external quality management System for the detection of relevant Chemical compounds from products and in ambient air. The project was structured in four phases (Horn et al., 2009 and 2011; Wilke et al., 2009a) This paper shows results of the fourth phase of the project, which was an inter-laboratory study for VOC-emission testing by means of emission test chambers. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Emission test chamber KW - Product emission testing KW - VOC-Emission KW - Round robin test PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Howard-Reed, C. A1 - Liu, Z. A1 - Cox, S. A1 - Little, J. A1 - Horn, Wolfgang A1 - Wilke, Olaf A1 - Wiegner, Katharina A1 - Persily, A. T1 - Inter-laboratory study approach to validate the performance of a prototype reference material for product emissions testing N2 - Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Test method validation KW - Volatile organic compounds KW - Product certification PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23883 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Panaskova, J. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Müller, D. A1 - Plehn, W. T1 - Results of sensory tests and sensory-limit settings for building materials in Germany N2 - Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources. Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Perceived air-quality KW - Odour evaluation KW - Odour labelling KW - Test procedure KW - Standardisation PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Müller, B. A1 - Panaskova, J. A1 - Jann, Oliver A1 - Plehn, W. A1 - Müller, D. T1 - VOC emissions from building materials accompanying sensory tests for different evaluation schemes N2 - Within a follow up project of a former study (Horn et al. 2005) emissions and odor from different types of construction products were investigated (financed by the German Federal Environmental Agency - FKZ 37 07 62 300). The tested materials were mainly those used for construction of floors indoors. For this type of materials in Germany several labeling procedures exist which are based on Emission chamber testing. Two important labeling procedures in Germany are based on the AgBBevaluation scheme (Däumling et al. 2005). For some applications (flooring material) it is the mandatory Ü-mark of DIBt (German Institute for Construction Technology). Furthermore for carpets, adhesives and many other products, like sealants, mattresses, furniture and so on the voluntary blue angel mark exist. Within this scheme the volatile organic compounds (VOC) compounds are measured with well established procedures and are evaluated with LCI-values which were derived from health information. Beyond that many complaints according to building products are caused by odors. Therefore an evaluation procedure for the odor is very important and should be implemented into all of the mentioned labeling schemes. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Odor KW - Construction product KW - VOC-emission KW - Evaluation KW - AgBB PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23881 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Horn, Wolfgang A1 - Wiegner, Katharina A1 - Wilke, Olaf A1 - Jann, Oliver T1 - Method validation study for VOC emission measurements N2 - Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency). A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products. Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Round robin test KW - VOC KW - Construction product KW - Emission PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23880 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Brödner, Doris A1 - Horn, Wolfgang T1 - Correlation of aldehyde emissions and fatty acids content in pine wood and oriented strand boards N2 - Indoor air quality is important for human health and comfort. To ensure good indoor air quality contamination by volatile organic compounds (VOC) should be minimised. The aim of the project is the reduction of unsaturated aldehydes which can emit from oriented Strand boards (OSB): These aldehydes have an impact on the health based evaluation of emissions from products for indoor use according to the AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products) scheine (AgBB 2010). The model OSB were produced in a pilot plant using well known raw materials (Pinus sylvestris at different trunk heights) under using various processing parameters (Wilke et al. 2011). OSB emit predominantly monoterpenes and aldehydes. Aldehydes are oxidation products of fatty acids in wood. The conditions which affect the oxidation process are the fatty acid concentration and composition, the oxygen content, the sample surface and the presence of compounds which indicate, inhibit or stop the oxidation respectively. The oxidation rate rises with an increasing number of double bounds in the fatty acid, e.g. the oxidation rate between oleic, linoleic and linolenic acid correspond to 1:12:24. One of the most important products of fatty acid oxidation is hexanal. It is generated during the oxidation of linoleic acid. This study shows a direct correlation between aldehyde emission and oxidation, hexanal can be used as an indicator for oxidation. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - VOCs KW - Oxidation products KW - Fatty acid KW - Saturated and unsaturated aldehyde KW - Hexanal PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23878 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiegner, Katharina A1 - Nohr, Michael A1 - Farke, M. A1 - Horn, Wolfgang A1 - Kalus, Sabine A1 - Jann, Oliver A1 - Hahn, Oliver T1 - Frische Luft für Museumsvitrinen - Neue Methode zur Untersuchung von Vitrinenbaumaterialien als Beitrag zur Präventiven Konservierung N2 - Nicht nur Schadstoffe aus der Umwelt können Museumsexponate schädigen. Auch interne Schadstoffquellen wie objektimmanente Exhalate und Emissionen von Lösemitteln oder organischen Säuren können den wertvollen Gu¨tern Schaden zufu¨gen. Auf Schadstoffe zu pru¨fen sowie geeignete Messmethoden zu entwickeln und zu optimieren, ist daher von großer Bedeutung. Neuste Forschungen stellen die Autoren vor. KW - VOC KW - Präventive Konservierung KW - Emissionsmessungen KW - AgBB-Schema KW - Ausstellungsvitrinen KW - Verpackungsmaterialien PY - 2011 SN - 0933-4017 VL - 117 IS - 5 SP - 30 EP - 35 PB - Callwey CY - München AN - OPUS4-23877 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiegner, Katharina A1 - Hahn, Oliver A1 - Farke, M. A1 - Kalus, Sabine A1 - Horn, Wolfgang T1 - Determination of formic and acetic acids in air N2 - Formic and acetic acids are often responsible for damage of cultural objects, e. g. glass and metal corrosion or changing and fading of colours. Museums all around the world are equipped with different show cases. Display cases should protect cultural objects from dust as well as from mechanical damage. Several construction materials which are used for display cases, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs), volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs). These construction products can emit formic and acetic acids into the indoor or display case air. Modern display cases with small air change rates can cause higher concentrations of formic and acetic acids if any source is installed in the display case (Salthammer and Uhde, 2009). To minimize the risk of damage emissions from building products must be quantified. There is a need for a method for identification and quantification of acetic and formic acid. Some possibilities for the identification of acetic acid exist. The quantification of acetic acid for example after sampling on TENAX® or CARBOTRAP and thermal desorption-GC in accordance with ISO 16000-6 and ISO 16017-1 results in very low recovery rates. A new method should be stabile, robust, reproducible and comparable, with an easy local sampling and determination in laboratories. Miniaturised emission test chambers and model display cases were used to study the recovery rates. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - VOCs KW - Detection of formic and acetic acid KW - Quantification of formic and acetic acid KW - Air sampling PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-23876 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -