TY - JOUR A1 - Schusterbauer, Robert A1 - Schünemann, Pia A1 - Nickl, Philip A1 - Er, Jasmin A1 - Kämmer, Victoria A1 - Junge, Florian A1 - Fazzani, Salim A1 - Mrkwitschka, Paul A1 - Meermann, Björn A1 - Haag, Rainer A1 - Donskyi, Ievgen T1 - Bifunctional Reduced Graphene Oxide Derivatives for PFOA Adsorption N2 - Innovative materials are crucial for removing persistent pollutants per‐ and polyfluorinated alkyl substances (PFAS) from water. Here, a novel bifunctional reduced graphene oxide (TRGO) adsorbent is developed and characterized by advanced surface sensitive methods. Compared to pristine TRGO, the functionalized TRGO shows markedly improved PFAS removal efficiency and demonstrates strong potential for water purification applications. KW - Adsorber KW - PFAS KW - HR-CS-GFMAS PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-651238 DO - https://doi.org/10.1002/ceur.202500240 SN - 2751-4765 SP - 1 EP - 7 PB - Wiley VHC-Verlag AN - OPUS4-65123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharek, Vera M. A1 - Kröger, Tommy A1 - Keil, Karin A1 - Traub, Heike A1 - Meermann, Björn T1 - A new elemental analytical approach for microplastic sum parameter analysis—ETV/ICP-MS with CO2 N2 - Microplastics (MPs) are pervasive environmental pollutants and are considered one of the main challenges of our time. However, a fast and comprehensive analytical approach for MP analysis in complex matrices traceable to SI units is still lacking. In this context, we report a fast screening tool for the sum parameter analysis of MPs using electrothermal vaporization (ETV) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). In our proof-of-concept study, we observed size-independent detection of MPs as peaks above the 13C+ signal background in the nano- to micrometer range without limitations regarding the polymer type. Quantification of the 13C+ MP signals was accomplished via an external gas calibration utilizing dynamic dilution of carbon dioxide with argon, yielding recovery rates of 80–96% for MP reference material (RM) of polymer types commonly found in the environment. The applicability to a soil sample was demonstrated through spiking experiments with a polyethylene (PE) MP RM in soil. The limit of detection (LOD) was estimated to be 0.13 µg C, equaling the detection of a single spherical low-density-PE particle of about 70 µm, and a limit of quantification (LOQ) of 0.42 µg C. KW - ETV/ICP-MS KW - Mikroplastik KW - Summenparameter PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-646418 DO - https://doi.org/10.1007/s00216-025-06146-x SN - 1618-2642 SP - 1 EP - 10 PB - Springer CY - Berlin ; Heidelberg AN - OPUS4-64641 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tavernaro, Isabella A1 - Simon, Fabian A1 - Gehrenkemper, Lennart A1 - Tobias, Charlie A1 - Resch-Genger, Ute A1 - Meermann, Björn T1 - Quantification of the amount of surface groups of aminated silica nano- and microparticles utilizing a fluorine tag and HR-CS-GFMAS N2 - The performance, bioavailability, and safe use of engineered nanomaterials (NMs) depends not only on properties such as size, shape, and surface area, but largely on surface chemistry. While many sizing methods have been established, there is still a lack of validated screening methods for determining NM surface functional groups (FGs). In this context, we present a fast and simple method for FG quantification using high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and assess its applicability for the surface analysis of representatively chosen aminated silica nanoparticles (NPs) and microparticles (MPs) in conjunction with amino FG labeling with a fluorine tag. For this proof-of-concept study, first surface amino FG screening of the silica NPs and MPs was done with a potentiometric back titration method, providing the total amount of protonatable surface FGs, and two optical assays relying on reporter dyes with sizes and spatial requirements, i.e., surface binding areas smaller or larger than that of the fluorine tag to estimate the maximum and reporter-accessible number of amino FGs. Subsequently, the surface amino FGs were labeled with the fluorine tag 4-(trifluoromethyl)benzoic acid (TFMB) and the amount of fluorine originating from the bound TFMB molecules was quantified by HR-CS-GFMAS in two common organic solvents, i.e., dimethyl sulfoxide (DMSO) or ethanol (EtOH) to assess possible interferences from organic matrices. Our study revealed limits of detection (LODs) and quantification (LOQs) for fluorine of 1.0 µg/L and 3.5 µg/L in EtOH and 1.5 µg/L and 5.0 µg/L in DMSO, respectively. Overall, a quick and simple method for analyzing surface FGs on NPs and MPs was presented utilizing broadly available fluorine tags and HR-CS-GFMAS for fluorine quantification, which can be applied, e.g., for homogeneity, stability, and aging studies of surface-modified particles. This could contribute to ease the understanding of property-safety relationships for surface-functionalized NMs. KW - Fluorine Analysis KW - Nano- and microparticles KW - Surface group quantification PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-641965 DO - https://doi.org/10.1007/s00216-025-06107-4 SN - 1618-2642 SP - 1 EP - 11 PB - Springer Science and Business Media LLC CY - Berlin ; Heidelberg AN - OPUS4-64196 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Scharek, Vera M. A1 - Pfeifer, Jens A1 - Vogl, Jochen A1 - Traub, Heike A1 - Meermann, Björn T1 - Tin fractionation analysis in sediment samples via on-line ID ETV/ICP-MS N2 - We report a quantification approach for directly determining total tin and tin-based pollutants/species in sediments via electrothermal vaporization/inductively coupled plasma-mass spectrometry (ETV/ICP-MS) utilizing an on-line isotope dilution mass spectrometry (IDMS) approach. The method was developed and validated using an estuarine sediment reference material (BCR-277R), yielding a recovery of 106%. A relative standard deviation (RSD) of 14%, comparable to published data using a similar method, was obtained. A limit of quantification (LOQ) was estimated at 0.008 mg Sn kg−1 and sufficient for quantifying the total tin mass fraction of surface sediments along the tidal River Elbe course. Hereby, a decrease towards the river mouth, presumably due to dilution effects by less polluted marine sediment, was observed. Besides total tin, monitoring of organotin compounds (OTCs)/species is of interest in sediments due to their toxic effects on aquatic life. The method’s capability was extended by separating an OTC fraction in a sediment certified reference material (CRM) through the ETV temperature program. While spiking experiments with OTC standards confirmed the assignment, only a small fraction of the total certified OTC amount (3%), likely due to matrix effects, was recovered. However, applying the method to real-world samples, OTCs were detectable along the River Elbe course. By this, we demonstrated the potential of our method as a complementary fast-screening approach to species-specific analysis procedures. KW - ETV KW - Sn-Speciation KW - Sediment PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-640137 DO - https://doi.org/10.1007/s00216-025-06064-y SN - 1618-2642 SP - 1 EP - 10 PB - Springer Science and Business Media LLC AN - OPUS4-64013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Michalska, Karina A1 - Heiermann, Monika A1 - Lühr, Carsten A1 - Meermann, Björn A1 - Pecenka, Ralf A1 - Schulz, Andreas A1 - Langhammer, Nicole A1 - Theuerl, Susanne A1 - Prochnow, Annette T1 - Potentials of typical plant species from rewetted fenlands for the supply of strategic elements N2 - Rewetting of peatlands requires the development of new biomass utilization pathways. The supply of strategic elements with key importance for the development of priority technologies, such as germanium (Ge), silicon (Si) and rare earth elements, from fenland plants is one option. To provide a first estimation of the potential, concentrations of strategic elements were determined in nine biomass samples covering typical fenland vegetation in northeast Germany. Subsequently, a simplified estimation of potential revenue from strategic element recovery was made. The analysed plant species can be classified as high or intermediate Si plant accumulators with highest contents of more than 16.0 g Si kg−1 dry mass (DM) in sedges and common reeds. Ge concentrations were lower with reed canary grass containing the highest amounts of 465.3 µg Ge kg−1 DM. Simultaneous acquisition of Ge and Si could provide higher total element yields and revenues of up to 500 $ ha−1. In contrast, the potentials for supplying rare earth elements appeared to be very low, with common reed containing the highest sum of rare earth elements of 437.4 µg kg−1 DM. Biomass from rewetted fenlands is capable of accumulating strategic elements. More knowledge is required to understand the factors affecting their accumulation. KW - Recycling KW - Fenlands KW - Strategic elements PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-635631 DO - https://doi.org/10.1038/s41598-025-05180-0 SN - 2045-2322 VL - 15 IS - 1 SP - 1 EP - 14 PB - Springer Science and Business Media LLC AN - OPUS4-63563 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mervič, Kristina A1 - Azimzada, Agil A1 - Bayat, Mehmet Emin A1 - Šala, Martin A1 - Meermann, Björn T1 - CO2-based matrix-independent carbon quantification approach for single microplastic-ICP-MS analysis N2 - This study presents a new CO2-based, matrix-independent calibration approach for size determination of microplastic (MP) particles using single particle inductively coupled plasma-mass spectrometry (sp-ICP-MS). By incorporating a CO2 gas calibration approach and upon adjusting the flow rates, an accurate size determination of MPs between 2 and 7 μm was enabled. Scanning electron microscopy (SEM) was successfully applied for method validation. The CO2 gas calibration curves exhibited excellent linearity and reproducibility, with minimal matrix effects across different sample types and matrices, including river water and saline solutions. This CO2-based approach eliminates the limitations of matrix- and size-dependent calibrations, enabling robust and accurate size determinations of MPs. This advancement represents a significant step forward in the analytical capabilities for MPs, paving the way for improved environmental monitoring and assessment of plastic pollution. KW - sp-ICP-MS KW - Microplastic KW - New calibration strategy PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-633049 DO - https://doi.org/10.1007/s00216-025-05934-9 SN - 1618-2642 SP - 1 EP - 11 PB - Springer CY - Berlin AN - OPUS4-63304 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schannor, Mathias A1 - Oelze, Marcus A1 - Traub, Heike A1 - He, Yubei A1 - Schmidt, Robin A1 - Heidemann, Luisa A1 - Savic, Lynn Jeanette A1 - Vogl, Jochen A1 - Meermann, Björn T1 - Advancing Biomarker Research: In Situ Cu Isotope Analysis in Liver Tumors by LA-MC-ICP-MS N2 - Stable metal isotopes have received increasing attention as medical biomarkers due to their potential to detect changes in metal metabolism related to diseases. In particular, copper stable isotopes are a powerful tool to identify isotopic variation between tumors and healthy tissue, suggesting application in cancer diagnosis. However, potential mechanisms causing isotope fractionation, such as redox- or bond-forming reactions and interactions of metals during transmembrane import and export, are less well understood. Here, we established an in situ method using laser ablation-multicollector-inductively coupled plasma-mass spectrometry (LA-MC-ICP-MS) to advance our understanding of the underlying processes responsible for isotope fractionation between normal and diseased tissues. Gelatin-based bracketing standards and quality control reference materials, crucial for laser ablation analysis, were developed to allow correction for instrumentally induced isotope fractionation during LA-MC-ICP-MS analysis. Using such matrix-matched standards, the method achieved intermediate precisions for delta values of better than 0.15 ‰ (2 s) for inorganic reference materials and of better than 0.17 ‰ (2 s) for biological reference materials. The developed routine was tested on rabbit VX2 liver tumor samples, a model system resembling human hepatocellular carcinoma (HCC) used to study liver cancer. In situ Cu isotope compositions between healthy (𝛿65/63NIST976(Cu) = −1.5 ‰ to 0.2 ‰) and tumorous (𝛿65/63NIST976(Cu) = 0.0 ‰ to 1.3 ‰) liver tissue show distinct differences in their isotope ratios. The observed isotopic dichotomy is consistent with previous solution-based MC-ICP-MS work, showing enrichment of heavy 65Cu in cancer biopsies relative to healthy tissue. KW - Biomarker KW - Laser Ablation KW - Reference Material PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-626865 DO - https://doi.org/10.1021/acs.analchem.4c05626 SN - 1520-6882 VL - 97 IS - 8 SP - 4425 EP - 4432 PB - American Chemical Society (ACS) AN - OPUS4-62686 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Azimzada, Agil A1 - Meermann, Björn T1 - AF4/ICP-ToF-MS for the investigation of species-specific adsorption of organometallic contaminants on natural colloidal particles N2 - Organotin (OT) compounds, while crucial in many industrial applications, pose substantial risks to the environment and human health. The toxicity and environmental behaviour of OTs depend on their chemical form, i.e., the type and number of organic substituents. Each species thus exhibits distinct toxicity profiles and varying binding affinities to environmental colloids, which influence their mobility, bioavailability, and environmental impacts. To date, however, most studies addressed speciation and colloidal characterization separately, leaving the combined determinations of organometallics along with their carrier colloids largely elusive. Here, we develop and validate an on-line measurement system to quantify the adsorption dynamics of 10 OT species on natural colloidal particles (<500 nm). The approach integrates a versatile fractionation technique (AF4), with a state-of-the-art multi-element analyzer (ICP-ToF-MS), achieving Sn detection limits as low as 6.0 ng/L. The method separates colloid-free OT species from those bound to colloids and enables the determination of OT interactions with distinct colloidal fractions. Validated in both fractionation and detection, the method provides reliable data that could elucidate the species-specific and temporal aspects of species-colloids adsorption processes. The results feature comparative studies of 10 OT species, offering critical insights into OT mobility and distribution in environmental systems. KW - Fractionation KW - Speciation KW - Adsorption KW - Colloids KW - Organotin KW - AF4 KW - Nanoparticle characterization PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-625244 DO - https://doi.org/10.1016/j.jhazmat.2025.137320 SN - 1873-3336 VL - 488 SP - 1 EP - 11 PB - Elsevier B.V. AN - OPUS4-62524 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tobias, Charlie A1 - Gehrenkemper, Lennart A1 - Bernstein, Thomas A1 - Schlau, Sven A1 - Simon, Fabian A1 - Röllig, Mathias A1 - Meermann, Björn A1 - von der Au, Marcus T1 - Development of a fully automated slurry sampling introduction system for GF-AAS and its application for the determination of cadmium in different matrices N2 - element analysis, offering high sensitivity and precision. However, its effectiveness is limited by sample preparation challenges for solid samples like soils and microplastics. Traditional methods include sample preparation, such as digestion, which is time-consuming and involves reagents, like acids, contributing to measurement uncertainty and higher carbon footprints. Slurry sampling allows direct analysis of suspensions, offering a more efficient alternative. However, maintaining suspension stability is challenging, requiring robust autosampler systems to streamline the process and enhance analytical performance. Results: We present a novel autosampler extension for slurry sample introduction into GF-AAS. This system ensures suspension stability with a stirring device and closed vessels to prevent evaporation and contamination, incorporating a cooling unit to reduce solvent and analyte losses. It installs and removes in minutes without additional connections. Validation with cadmium analysis in BAM-U110 (Soil) and BAM-H010 (ABS) showed high reliability. For BAM-U110 (Soil), we achieved recovery rates of 94 % ± 13 % in water suspension. The recovery rate for BAM-H010 (ABS) was 104 % ±11 % in acetonitrile suspension. These results demonstrate the system’s robustness, versatility, and accuracy for different matrices. Significance: The autosampler extension helps solve key problems in trace element analysis of solid samples, making the process faster and more accurate. It works well with complex materials, making it useful for areas like microplastic or nanoparticle analysis. This improvement also helps meet regulations for monitoring environ mental and polymer samples, offering a reliable and flexible tool for high-throughput analysis with fewer errors. KW - Slurry AAS KW - Soil KW - Cd PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-618531 DO - https://doi.org/10.1016/j.aca.2024.343460 SN - 0003-2670 VL - 1335 SP - 1 EP - 7 PB - Elsevier BV AN - OPUS4-61853 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Breuninger, Esther S. A1 - Tolu, Julie A1 - Aemisegger, Franziska A1 - Thurnherr, Iris A1 - Bouchet, Sylvain A1 - Mestrot, Adrien A1 - Ossola, Rachele A1 - McNeill, Kristopher A1 - Tukhmetova, Dariya A1 - Vogl, Jochen A1 - Meermann, Björn A1 - Sonke, Jeroen E. A1 - Winkel, Lenny H. E. T1 - Marine and terrestrial contributions to atmospheric deposition fluxes of methylated arsenic species N2 - Arsenic, a toxic element from both anthropogenic and natural sources, reaches surface environments through atmospheric cycling and dry and wet deposition. Biomethylation volatilizes arsenic into the atmosphere and deposition cycles it back to the surface, affecting soil-plant systems. Chemical speciation of deposited arsenic is important for understanding further processing in soils and bioavailability. However, the range of atmospheric transport and source signature of arsenic species remain understudied. Here we report significant levels ofmethylated arsenic in precipitation, cloudwater and aerosols collected under free tropospheric conditions at Pic du Midi Observatory (France) indicating long-range transport, which is crucial for atmospheric budgets. Through chemical analyses andmoisture source diagnostics, we identify terrestrial and marine sources for distinct arsenic species. Estimated atmospheric deposition fluxes of methylated arsenic are similar to reported methylation rates in soils, highlighting atmospheric deposition as a significant, overlooked source of potentially bioavailable methylated arsenic species impacting plant uptake in soils. KW - Arsenic KW - Speciation KW - Fluxes KW - Marine KW - Terrestrial KW - Sulfur isotopes PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-615551 DO - https://doi.org/10.1038/s41467-024-53974-z SN - 2041-1723 VL - 15 IS - 1 SP - 1 EP - 13 PB - Springer Science and Business Media LLC AN - OPUS4-61555 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -