TY - CONF A1 - Resch-Genger, Ute T1 - How to get it right with photoluminescence measurements in the UV/VIS/NIR N2 - Optical measurements of transparent solutions of organic dyes and semiconductor quantum dots and scattering materials such as luminescent nanocomposites and microparticles and phosphors dispersed in liquid and solid matrices play an important role in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. A key performance parameter is the photoluminescence quantum yield QY, i.e., the number of emitted per number of absorbed photons. QY of transparent luminophore solutions can be obtained relative to a fluorescence QY standard of known QY. Such relative QY measurements require a calibrated spectrofluorometer. Here, we address typical sources of uncertainty for luminescence measurements and relative and absolute QY measurements from the instrument and material side and provide recommendations to circumvent or at least minimize them for transparent and scattering samples in the UV/vis/NIR/SWIR. T2 - Workshop "Photoluminescence Spectroscopy and its application in Materials Research" CY - Vienna, Austria DA - 19.02.2026 KW - Quality assurance KW - Reference material KW - Fluorescence KW - Dye KW - Traceability KW - Metrology KW - Calibration KW - Reference data KW - Reference product KW - Digital certificate KW - NIR KW - Instrument performance validation PY - 2026 AN - OPUS4-65575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Würth, Christian A1 - Resch-Genger, Ute T1 - Absolute determination of photoluminescence quantum yields of scattering led converter materials how to get it right N2 - Scattering luminescent materials dispersed in liquid and solid matrices and luminescent powders are increasingly relevant for fundamental research and industry. Examples are luminescent nano- and microparticles and phosphors of different compositions in various matrices or incorporated into ceramics with applications in energy conversion, solid-state lighting, medical diagnostics. A key performance parameter is the photoluminescence quantum yield (Φf), i.e., the number of emitted per number of absorbed photons. Φf of transparent luminophore solutions can be obtained relative to a fluorescence Φf standard of known Φf, meanwhile available as certified reference materials.[1] The determination of Φf of scattering liquid and solid samples requires, however, absolute measurements with an integrating sphere setup. Fist we present the results of an interlaboratory comparison of 3 labs from academia and industry on measurements of transparent and scattering dye solutions and YAG:Ce optoceramics, an optical converter material, with commercial stand-alone integrating sphere setups of different illumination and detection geometries.[2] Second we present results for a series of 500 μm-thick polymer films containing different concentrations of photoluminescent and scattering YAG:Ce microparticles.[3] We systematically explored and quantified pitfalls of absolute Φf measurements with special emphasis dedicated to the influence of measurement geometry, optical properties of the blank for determining the number of incident photons absorbed by the sample, and sample-specific surface roughness. Matching Φf values could be easily obtained for transparent dye solutions and scattering dispersions with a blank with scattering properties closely matching those of the sample, Φf measurements of optoceramic samples with different blanks revealed substantial differences of more than 20 %. Our results further reveal that setup configurations can introduce systematic errors resulting in under- or overestimation of the absorbed photon flux and hence an under- or overestimation of Φf. T2 - Shift 2025 CY - La Laguna, Tenerife, Spain DA - 13.10.2025 KW - Quantum Yield KW - LED Converter KW - Luminescent KW - Microparticles PY - 2025 AN - OPUS4-64785 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Molecular and nanoscale emitters photophysics , photoluminescence quantum yields, and surface chemistry N2 - Inorganic nanocrystals such as spectrally shifting lanthanide-based nanoparticles (LnNCs) like NaYF4: Yb, Er and semiconductor quantum dots, organic and inorganic particles stained with sensor molecules, and organic dyes showing aggregation-induced emission are meanwhile broadly applied in the life and material sciences. The identification of optimum particle architectures and molecular structures for photonic applications requires quantitative spectroscopic studies and methods to control and analyse particle surface chemistry. In the following, photoluminescence studies of different emitter classes are presented, thereby addressing the measurement of particle brightness and photoluminescence quantum yields in different spectral windows parameters required for an in-depth mechanistic understanding. In addition, examples for the quantification of surface functional groups on nanomaterials with optical spectroscopy are given. T2 - GdCH Kolloquium CY - Düsseldorf, Germany DA - 11.11.2025 KW - Dye KW - Fluorescence KW - Quantum yield KW - Lifetime KW - Sensor materials KW - Temperature KW - Cr(III) complex KW - Nano KW - Particle KW - Silica KW - Polymer KW - Metrology KW - Quality assurance KW - Reference material KW - Surface chemistry KW - Size KW - Shape KW - Particle number concentration KW - Method KW - Optical assay KW - qNMR KW - Validation KW - Potentiometry KW - XPS PY - 2025 AN - OPUS4-64728 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantifying the total and accessible amount of surface functionalities and ligands on nano-materials: Overview and recommended methods N2 - Engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage. NP function, interaction with biological species, and environmental fate are largely determined by surface functionalities. This calls for reliable, reproducible, and standardized surface characterization methods, which are vital for quality control of NPs, and mandatory to meet increasing concerns regarding their safety. Validated and standardized workflows for surface analysis are also increasingly requested by industry, international standardization organizations, regulatory agencies, and policymakers. To establish comparable measurements of surface functionalities across different labs and ease instrument performance validation, reference test materials and reference materials of known surface chemistry as well as reference data are needed. In the following, different methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques are presented and discussed regarding method-inherent advantages and limitations. Special emphasis is dedicated to traceable quantitative nuclear magnetic resonance (qNMR), X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods. T2 - LNE Workshop CY - Paris, France DA - 04.11.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Automation KW - Potentiometry KW - Method KW - Validation KW - Optical assay KW - Fluram KW - Fluorescamine KW - qNMR KW - Comparison KW - ILC PY - 2025 AN - OPUS4-64726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - The emp project smurfnano – Standardizing the quantification of surface functionalities, ligands, and coatings on nanomaterials N2 - For industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage, meanwhile engineered nanoparticles (NPs) with various chemical compositions and surface functionalities are routinely fabricated. NP function, interaction with biological species, and environmental fate are largely determined by surface functionalities. Reliable, reproducible, and standardized surface characterization methods are therefore vital for quality control of NPs, and mandatory to meet increasing concerns regarding their safety. Also, industry, international standardization organizations, regulatory agencies, and policymakers need validated and standardized measurement methods and reference materials. These needs are addressed by the recently started European metrology project SMURFnano involving 12 partners from different National Metrology Institutes, designated institutes, and research institutes, two university groups as well as one large company and one SME producing NPs. This project as well as first results derived from the development of test and reference materials with a well characterized surface chemistry and ongoing interlaboratory comparisons will be presented. T2 - LNE Workshop CY - Paris, France DA - 04.11.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Automation KW - Potentiometry KW - Method KW - Validation KW - Optical assay KW - Fluram KW - qNMR KW - Comparison KW - ILC PY - 2025 AN - OPUS4-64725 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Reliable measurements of the photoluminescence quantum yield of transparent and scattering luminophores N2 - Optical measurements of transparent solutions of organic dyes and semiconductor quantum dots and scattering materials such as luminescent nanocomposites and microparticles and phosphors dispersed in liquid and solid matrices play an important role in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. A key performance parameter is the photoluminescence quantum yield QY, i.e., the number of emitted per number of absorbed photons. QY of transparent luminophore solutions can be obtained relative to a fluorescence QY standard of known QY.[1] Meanwhile, a first set of certified fluorescence QY standards is available.[2] Such relative QY measurements require a calibrated spectrofluorometer.[1,3] For determining QY of scattering liquid and solid samples, absolute measurements of QY with a calibrated integrating sphere setup are mandatory.[1,4,5] However, scattering QY standards are not available and uncertainties of such measurements have not yet been assessed in interlaboratory comparisons (ILCs). To determine typical sources of uncertainty of absolute QY measurements, we assessed the influence of the measurement geometry and the optical properties of the blank for determining the number of incident photons absorbed by the sample in an ILC using commercial integrating sphere setups and a custom-designed integrating sphere setup. Samples examined included transparent and scattering dye solutions, solid phosphors such as YAG:Ce optoceramics used as LED converter material, and polymer films stained with different amounts of phosphor microparticles. Matching QY values could be obtained for transparent dye solutions and scattering dispersions with a blank with scattering properties closely matching those of the sample, while QY measurements of optoceramic samples with different blanks revealed substantial differences of more than 20 %. Based on our data, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder as blanks. T2 - eMRS 2025 Fall Meeting CY - Warsaw, Poland DA - 15.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Advanced material KW - Synthesis KW - Characterization KW - Fluorescence quantum yield KW - Phosphor KW - Absolute KW - Integrating sphere spectroscopy KW - Dye KW - Standardization KW - Reference material KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64184 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantifying functional groups and coatings on nanoobjects N2 - Engineered nanomaterials (NM) of different size, shape, chemical composition, and surface chemistry are increasingly used for many key technologies of the 21st century and consumer products. This includes polymer and silica or silica-coated nanoparticles (NP) with covalently bound surface groups, semiconductor quantum dots (QD), metal and metal oxide NP, and lanthanide NP with coordinatively or electrostatically bound ligands, as well as surface-coated nanostructures like micellar encapsulated NP. Decisive for most applications of NMs are their specific surface properties, which are largely determined by the chemical nature and amounts of ligands and functional groups (FGs) on the NM surface. The surface chemistry can strongly affect the physicochemical properties of NM, their charge, hydrophilicity/hydrophobicity, reactivity, function, stability, and processability and thereby their impact on human health and environment. Knowledge of NM surface chemistry plays an important role for NM functionality and performance in (bio)applications and the fate, exposure, dissolution, transformation, and accumulation of NM, and thus, the potential risks for human health and the environment. This highlights the importance of reliable, validated, and eventually standardized analytical methods for analyzing and quantifying NM surface chemistry for process and quality control of NM production, safe use of NMs, design of novel NM, and sustainable concepts for NM fabrication.[1-3] In this context, interlaboratory comparisons (ILCs) are needed to assess method reliability and reference materials with known surface chemistries for establishing surface analytical methods and their performance validation.[2,4] Also, to respond to the increasing number of samples to be analyzed, cost-efficient automation concepts for surface analysis are needed that can be realized with affordable and preferably commercial instrumentation.[5] Here, we provide an overview of analytical methods for FG analysis and quantification used by us for quantifying broadly utilized FGs and ligands on different types of NMs with electrochemical titration methods, optical assays, nuclear magnetic resonance (NMR) and vibrational (IR) spectroscopy, and X-ray based and thermal analysis methods.[1,2] Thereby, method- and material-related challenges are addressed, and the importance of multi-method characterization approaches easing method validation by method cross-validation. Special emphasis is dedicated to simple, versatile, and cost-efficient methods such as optical assays and electrochemical titration methods. T2 - eMRS Fall Meeting 2025 CY - Warsaw, Poland DA - 15.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64183 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantifying the total and accessible amount of surface functionalities and ligands on nanomaterials N2 - Engineered nanomaterials (NMs) of various chemical composition and surface functionalization are routinely fabricated for industrial applications such as medical diagnostics, drug delivery, sensing, catalysis, energy conversion and storage, opto-electronics, and information storage. NM dispersibility, stability, processability, and function as well as the interaction with biological species and environmental fate are largely determined by NM surface functionalities, i.e., functional groups (FGs) and ligands. Therefore, reliable, reproducible, and eventually standardized surface characterization methods are vital for quality control of NMs, and mandatory to meet increasing concerns regarding their safety. Suitable methods for determining surface functionalities on ligand-stabilized core and core/shell NPs include advanced techniques such as traceable quantitative nuclear magnetic resonance (qNMR) as well as X-ray electron spectroscopy (XPS) and time of flight secondary ion mass spectrometry (ToF-SIMS), and simpler optical and electrochemical methods.[1] The latter less costly and fast methods, which can be automated, are often used by NM producers for process and quality control.[1,2] To validate methods, establish measurement uncertain-ties, test reference materials, and produce reference data, multi-method characterization studies are needed.[3,4] as well as interlaboratory comparisons (ILC) on determining NM surface chemistry and well characterized test and reference NMs providing benchmark values.[5,6] Here, we present examples for quantifying common surface FGs such as amino and carboxyl groups on functional NMs of different chemical composition such as silica, polymer, iron oxide, and lanthanide-based upconversion nanoparticles with optical assays, electrochemical titration methods, qNMR, and chromatographic separation techniques. In addition, ongoing interlaboratory comparisons will be presented. T2 - Yucomat 2025 CY - Herec Novi, Montenegro DA - 01.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Characterization KW - Advanced material KW - Surface KW - Standardization KW - Reference material KW - Functional group KW - Quantification KW - Coating KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64182 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - From molecular and nanoscale chromophores with UV/VIS/NIR/SWIR luminescence to multi method characterization of surface coatings N2 - An overview of the research activities of division Biophotonics is presented covering examples for photophysical studies of different types of molecular and nanocrystalline luminophores, luminescent particles, and sensor systems in solution, in dispersion, and in the solid state and multi-method charactreization workflow for the characterization of surface-functionalized engineered nanomaterials. In addition, the importance of reliable optical measurements, particularly standardized workflows for the determination of the key performance parameter luminescence quantum yield of transparent and scattering luminescent samples with fluorescence and integrating sphere spectroscopy, and validated methods for quantifying surface functional groups and ligands on nanomaterials is highlighted. Thereby, also ongoing standardization activities are presented as well as certified reference materials and reference materials from division Biophotonics. T2 - Chinese-German Chemical Association - Annual Meeting CY - Berlin, Germany DA - 22.08.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Quantum yield KW - Characterization KW - Advanced material KW - Surface KW - Lifetime KW - Sensor KW - Oxygen KW - Ph KW - Standardization KW - Fluorescent probe KW - Reference material PY - 2025 AN - OPUS4-64181 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Assessing different types of silica networks for the complete protection of nir luminescent molecular rubies from oxygen quenching in air N2 - The application of emerging luminophores such as near-infrared (NIR) emissive earth-abundant chromium(III) (CrIII) complexes and triplet-triplet annihilation upconversion (TTA-UC) systems in air as optical reporters for bioimaging or photonic materials for energy conversion requires simple and efficient strategies for their complete protection from luminescence quenching by oxygen. Therefore, we explored the influence of sol-gel synthesis routes on the oxygen protection efficiency of the resulting core and core/shell silica nanoparticles (SiO2 NPs), utilizing the molecular ruby-type luminophores CrPF6 ([Cr(ddpd)2](PF6)3; ddpd = N,N’-dimethyl- N,N’-dipyridin-2-ylpyridin-2,6-diamine) and CrBF4 ([Cr(ddpd)2](BF4)3) with their oxygen-dependent, but polarity-, proticity-, viscosity-, and concentration-independent luminescence as optical probes for oxygen permeability. The sol-gel chemistry routes we assessed include the classical Stöber method and the underexplored larginine approach, which relies on the controlled hydrolysis of tetraethoxysilane (TEOS) in a biphasic cyclohexane/water system with the catalyst l-arginine. As demonstrated by luminescence measurements of air- and argon-saturated dispersions of CrPF6- and CrBF4-stained SiO2 NPs of different size and particle architecture, utilizing the luminescence decay kinetics of argon-saturated solutions of CrPF6 and CrBF4 in acetonitrile (ACN) as benchmarks, only SiO2 NPs or shells synthesized by the l-arginine approach provided complete oxygen protection of the CrIII complexes under ambient conditions. We ascribe the different oxygen shielding efficiencies of the silica networks explored to differences in density and surface chemistry of the resulting nanomaterials and coatings, leading to different oxygen permeabilities. Our l-arginine based silica encapsulation strategy can open the door for the efficient usage of oxygen-sensitive luminophores and TTA-UC systems as optical reporters and spectral shifters in air in the future. T2 - eMRS Strasbourg CY - Strasbourg, France DA - 26.05.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Synthesis KW - Quantum yield KW - NIR KW - Mechanism KW - Characterization KW - Electron microscopy KW - Silica KW - Oxygen sensing KW - Surface KW - Doping KW - Lifetime KW - Cr(III) complex PY - 2025 AN - OPUS4-63300 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -