TY - CONF A1 - Malow, Marcus A1 - Wehrstedt, Klaus-Dieter A1 - Michael-Schulz, Heike T1 - Problems encountered comparing UN-Test H.2 und UN-Test H.4 results T2 - IGUS Energetic and Oxidising Substances (EOS) Working Group Meeting CY - Tokyo, Japan DA - 2010-05-26 PY - 2010 AN - OPUS4-21361 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Wehrstedt, Klaus-Dieter T1 - DSC: Thermal stability of dilauroylperoxide T2 - IGUS Energetic and Oxidising Substances (EOS) Working Group Meeting CY - Tokyo, Japan DA - 2010-05-26 PY - 2010 AN - OPUS4-21362 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Wehrstedt, Klaus-Dieter A1 - Michael-Schulz, Heike T1 - Modified Setup of 20-L-Sphere of Determination of Safety Characteristics of Nano Powders T2 - 17th CY - Tokyo, Japan DA - 2010-05-26 PY - 2010 AN - OPUS4-21364 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Lüth, Peter A1 - Brandes, E. A1 - Frost, K. A1 - Kurth, Lutz A1 - Schmidt, Martin A1 - Michael-Schulz, Heike A1 - Uhlig, S. T1 - CEQAT-DGHS Interlaboratory test programme for chemical safety - status and activities N2 - Safety experts, carriers or traders must be able to rely on the validity of the method and on correct results of safety tests and assessments in the laboratory. Bundesanstalt für Materialforschung und –prüfung (BAM), Berlin and Physikalisch-Technischen Bundesanstalt (PTB), Braunschweig have extensive experience in the field of testing and assessment of physical hazards of chemicals. Interlaboratory tests on different test methods have been performed by BAM and PTB during the last 10 years. Significant differences between the results of the participating laboratories were observed in all interlaboratory test. The deviations of the test results were not caused only by laboratory faults but also by deficiencies of the test method; i.e. many of the method descriptions are too ambiguous and allow divergences for interpretation. Therefore, it is necessary to know exactly how good the method is that is used to classify dangerous goods or hazardous substances or to determine safety-relevant parameters. A key criterion is the measurement uncertainty. One can choose simple methods with large error limits, but the measurement uncer-tainties should be known and always communicated together with the test results. This would allow safety specialists to be able to assess test results correctly and make well-founded decisions, e.g. for adequate protective measures. Interlaboratory tests play a decisive role in assessing the reliability of test results. Participation in interlaboratory tests is not only a crucial element of the quality as-surance of laboratories; as such it is explicitly recommended in DIN EN ISO/IEC 17025. In addition, interlaboratory tests are also used to develop and validate test methods and can be used for the determination of the measurement uncertainty. Therefore, the BAM and PTB continue to support the further development of the interlaboratory test programme of CEQAT-DGHS (Centre for quality assurance for testing of dangerous goods and hazardous substances, www.ceqat-dghs.bam.de), established in 2007. This programme is run by BAM in collaboration with the PTB and the QuoData Gesellschaft für Qualitätsmanagement und Statistik mbH, Dresden. A new interlaboratory test for methods validation on the test method UN Test N.5 "Test method for substances which in contact with water emit flammable gases” is currently being prepared and will be carried out in 2018. Laboratories that specialise in this test are invited to participate in the interlaboratory test. Interested laboratories can check the details and register to participate in the interlaboratory test at the CEQAT-DGHS website. T2 - MEETINGS OF IGUS EOS GROUP CY - Shanghai, P.R. China DA - 09.04.2018 KW - Interlaboratory test KW - Dangereous goods KW - Hazardous substances KW - Test method KW - Validation PY - 2018 AN - OPUS4-44825 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Salg, Steffen A1 - Michael-Schulz, Heike T1 - A new apparatus for the investigaton of deflagrations T2 - IGUS EOS meeting CY - Ottawa, Canada DA - 2015-05-06 PY - 2015 AN - OPUS4-33378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Erdt, René A1 - Michael-Schulz, Heike A1 - Rudolph, Michael T1 - UN Test N.5 - new test results T2 - IGUS EOS meeting CY - Ottawa, Canada DA - 2015-05-06 PY - 2015 AN - OPUS4-33379 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Salg, Steffen A1 - Michael-Schulz, Heike T1 - Use of four-liter-autoclave for conducting deflagration tests T2 - New Trends in Reseach of Energetic Materials CY - Pardubice, the Czech Republic DA - 2015-04-15 PY - 2015 AN - OPUS4-33382 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Lüth, Peter T1 - CEQAT-DGHS Development of procedures for the verification of test apparatuses (Example UN Test N.5) N2 - This presentation focuses on General aspects of development of verification methods. The development of verification methods is demonstrated using the test method UN Test N.5 as an example. T2 - EOS IGUS Meeting CY - Brussels, Belgium DA - 21.05.2019 KW - Dangerous Goods KW - UN-Test N.5 KW - Verification method KW - Measurement uncertainty PY - 2019 AN - OPUS4-49003 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus A1 - Knorr, Annett A1 - Jungnickel, Ralf T1 - Different methods for the determination of calcium peroxide N2 - The CaO2 Content ist analyzed using different titration methods. The results and the methods are compared. CaO2 is a reference material in the UN Test method O.3. T2 - EOS IGUS Meeting CY - Brussels, Belgium DA - 21.05.2019 KW - Dangerous Goods KW - UN-Test O.3 KW - Calcium peroxid KW - Content of calcium peroxide PY - 2019 AN - OPUS4-49001 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Malow, Marcus T1 - Notwendigkeiten und Möglichkeiten zur Verifizierung von Prüfapparaturen zur Bestimmung sicherheitstechnischer Kennzahlen N2 - Prüfapparaturen zur Bestimmung sicherheitstechnischer Kennzahlen müssen präzise messen, um verlässliche Ergebnisse zu produzieren. Oftmals gibt es in der Methodenbeschreibung allerdings keine Informationen zu Messunsicherheiten o.ä.. In dem Vortrag werden Ringversuchsprogramme das CEQAT-DGHS beschrieben und aktuelle Arbeiten zu Verifizierungsverfahren von Messmethoden beschrieben. T2 - 14. Fachtagung Anlagen-, Arbeits- und Umweltsicherheit CY - Köthen, Germany DA - 07.11.2019 KW - Gefahrgut KW - UN-Test N.5 KW - Verifizierung von Prüfapparaturen KW - Messunsicherheit PY - 2019 AN - OPUS4-50233 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -