TY - CONF A1 - Linck, Lena A1 - Resch-Genger, Ute T1 - Optimized Fluorescence Detection for RCA-Assays on Microarrays T2 - Kolloquium CY - Potsdam, Germany DA - 2010-08-25 PY - 2010 AN - OPUS4-22081 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pauli, Jutta A1 - Würth, Christian A1 - Güttler, Arne A1 - Resch-Genger, Ute T1 - Reliable Determination of the Signal-Relevant Spectroscopic Key Characteristics of Luminescent Reporters and Optical Probes for Imaging in the vis/NIR/SWIR N2 - Introduction. Comparing different emitter classes and rationally designing the next generation of molecular and nanoscale probes for bioimaging applications require accurate and quantitative methods for the measurement of the key parameter photoluminescence quantum yield f.1 f equals the number of emitted per number of absorbed photons. This is particularly relevant for increasingly used fluorescence imaging in the short wave-infrared region (SWIR) ≥ 900 nm providing deeper penetration depths, a better image resolution, and an improved signal-to-noise or tumor-to-background ratio.2, 3 However, spectroscopic measurements in the SWIR are more challenging and require specific calibrations and standards. T2 - EMIM 2021 CY - Göttingen, Germany DA - 24.08.2021 KW - Fluorescence KW - Optical probe KW - Dye KW - Photophysics KW - Quantum yield KW - Mechanism KW - NIR KW - SWIR KW - Imaging KW - Reference material KW - Reliability KW - Nano KW - Particle KW - Method KW - Quality assurance PY - 2021 AN - OPUS4-53233 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Petrov, Eugene A1 - Würth, Christian A1 - Richter, Maria A1 - Resch-Genger, Ute T1 - Fluorescence Standards from BAM - Dye Solutions and Polymer systems N2 - For fluorescence microscopy, there is an increasing need for suitable calibration tools and reference materials for microscope calibration, the determination of performance parameters, and the regular control and validation of instrument performance. This is addressed in the BmWk-financed project FluMikal (WIPANO program) by two research groups from academia and two companies, that is coordinated by BAM. Here we present different approaches to liquid and solid fluorescence standards for the determination of the wavelength-dependent spectral sensitivity of fluorescence microscopes and ideas concerning the choice of suitable fluorescence lifetime standard for increasingly utilized fluorescence lifetime imaging (FLIM). T2 - FluMiKal Projectmeeting CY - Munich, Germany DA - 27.11.2023 KW - Reference material KW - Reference product KW - Fluorescence microscopy KW - Quality assurance KW - Instrument performance validation KW - Lifetime standard PY - 2023 AN - OPUS4-59120 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Quantitation of luminescent properties of Yb and Ho co-doped NaYF4 colloidal nanoparticles - novel active-core-active-shell materials and novel characterization methods N2 - At the core of luminescence color and lifetime tuning of rare earth doped upconverting nanoparticles (UCNPs) is the understanding of the impact of the particle architecture for commonly used sensitizer (S) and activator (A) ions. In this respect, we present here a series of core@shell NaYF4 UCNPs doped with Yb3+ and Ho3+ ions, where the same dopant concentrations were distributed in different particle architectures following the scheme: YbHo core and YbHo@..., …@YbHo, Yb@Ho, Ho@Yb, YbHo@Yb, and Yb@YbHo core-shell NPs. As revealed by quantitative steady state and time-resolved luminescence studies, the relative spatial distribution of the A and S ions in the UCNPs and their protection from surface quenching has critical impact on their luminescent characteristics. Interestingly, although the increased amount of Yb3+ ions boosts UCNP performance by increasing the absorption, the Yb3+ ions can also dissipate the energy stored in the material through energy migration to surface, thereby reducing the overall energy transfer efficiency to the activator ions. T2 - COST Workshop CY - Aveiro, Portugal DA - 30.06.2017 KW - Upconversion KW - Nanoparticle KW - Flourescence KW - Core-shell architecture KW - NIR KW - Absolute flourometry KW - Integrating sphere spectroscopy KW - Ho(III) KW - Yb(III) PY - 2017 AN - OPUS4-41161 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Design, characterization, and application of fluorescent sensor particles N2 - pH and oxygen are amongst the most important and frequently measured analytes in the life and material sciences, indicating, e.g., diseases and corrosion processes. This includes the optical monitoring of pH in living cells for studying cellular internalization pathways, such as phagocytosis, endocytosis, and receptor ligand internalization with the aid of molecular and nanoscale fluorescent sensors. Nanoparticle (NP)-based sensors, that are labeled or stained with a multitude of sensor dyes, have several advantages as compare to conventional molecular probes like enhanced brightness, i.e., amplified signals, ease of designing ratiometric systems by combining analyte sensitive and inert reference dyes, and increased photostability. Moreover, this can enable the use of hydrophobic dyes in aqueous environments. Versatile templates and carriers for the fabrication of nanosensors by the staining and/or labelling with different fluorophores and sensor molecules or surface functionalized NP like silica (SiO2-NP) and polystyrene (PS-NP) particles provide. Here we present the design of a versatile platform of color emissive nanosensors and stimuli-responsive microparticles for the measurement of pH, oxygen, and other targets utilizing both types of matrices and sets of spectrally distinguishable sensor and reference dyes and their characterization and demonstrate the applicability of representative sensor particle for cellular studies. T2 - Vortrag bei dem Projekttreffen MicraGen CY - Copenhagen, Denmark DA - 18.08.2022 KW - Dye KW - Luminescence KW - Quantitative spectroscopy KW - Photophysics KW - Quality assurance KW - Nano KW - Particle KW - Quantum yield KW - Lifetime KW - Standard KW - Integrating sphere spectroscopy KW - Sensor KW - pH KW - Oxygen KW - Microfluidics KW - Cancer KW - Cell KW - Life sciences PY - 2022 AN - OPUS4-57049 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Research and development in material and life sciences and quality assurance at BAM N2 - Research and development activities at BAM are presented with Special Focus on bioanalysis and biophotonics. This includes Topics from the Focus Areas Material, Environment, and Analytical Sciences. Also, Job opportunities at BAM are emphasized. T2 - MPI CY - Göttingen, Germany DA - 26.10.2017 KW - Analytics KW - Materials KW - Fluorometry KW - Sensors KW - Biophotonics KW - Microbiology KW - Reference material KW - Standard KW - Calibration KW - Nanoparticle PY - 2017 AN - OPUS4-43132 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Methods for the Determination of the Optical Properties and the Surface Chemistry of Fluorescent Particles T2 - SPIE BIOS 20123 - Part of Photonics West CY - San Francisco, CA, USA DA - 2013-02-02 PY - 2013 AN - OPUS4-29229 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Reliable measurements of the photoluminescence quantum yield of transparent and scattering luminophores N2 - Optical measurements of transparent solutions of organic dyes and semiconductor quantum dots and scattering materials such as luminescent nanocomposites and microparticles and phosphors dispersed in liquid and solid matrices play an important role in energy conversion, solid-state lighting, medical diagnostics, and security barcoding. A key performance parameter is the photoluminescence quantum yield QY, i.e., the number of emitted per number of absorbed photons. QY of transparent luminophore solutions can be obtained relative to a fluorescence QY standard of known QY.[1] Meanwhile, a first set of certified fluorescence QY standards is available.[2] Such relative QY measurements require a calibrated spectrofluorometer.[1,3] For determining QY of scattering liquid and solid samples, absolute measurements of QY with a calibrated integrating sphere setup are mandatory.[1,4,5] However, scattering QY standards are not available and uncertainties of such measurements have not yet been assessed in interlaboratory comparisons (ILCs). To determine typical sources of uncertainty of absolute QY measurements, we assessed the influence of the measurement geometry and the optical properties of the blank for determining the number of incident photons absorbed by the sample in an ILC using commercial integrating sphere setups and a custom-designed integrating sphere setup. Samples examined included transparent and scattering dye solutions, solid phosphors such as YAG:Ce optoceramics used as LED converter material, and polymer films stained with different amounts of phosphor microparticles. Matching QY values could be obtained for transparent dye solutions and scattering dispersions with a blank with scattering properties closely matching those of the sample, while QY measurements of optoceramic samples with different blanks revealed substantial differences of more than 20 %. Based on our data, we recommend non-absorbing blank materials with a high reflectivity (>95 %) such as a 2 mm-thick PTFE target placed on the sample holder as blanks. T2 - eMRS 2025 Fall Meeting CY - Warsaw, Poland DA - 15.09.2025 KW - Quality assurance KW - Fluorescence KW - Nano KW - Particle KW - Advanced material KW - Synthesis KW - Characterization KW - Fluorescence quantum yield KW - Phosphor KW - Absolute KW - Integrating sphere spectroscopy KW - Dye KW - Standardization KW - Reference material KW - Interlaboratory comparison KW - Uncertainty PY - 2025 AN - OPUS4-64184 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Needs and Tools Standardization of Fluorescence N2 - Photoluminescence techniques are amongst the most widely used tools in the life sciences, with new and exciting applications in medical diagnostics and molecular imaging continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. General drawbacks are, however, signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are also time-dependent due to aging of instrument-components, and difficulties to measure absolute fluorescence intensities. Moreover, scattering samples require special measurement geometries and emerging optical Reporters with emission > 1000 nm strategies for reliable measurements in the second diagnostic window or short wavelength infrared (SWIR) for the comparison of material performance and the rational design of new fluorophores with improved properties. Here, we provide a brief overview over different types of fluorescence standards for instrument calibration and performance control. Also, strategies to versatile method-adaptable liquid and solid fluorescence standards for different fluorescence parameters and applications are presented. This includes spectral emission standards for the traceable determination of the wavelengthdependent spectral responsivity (emission correction curve) of fluorescence measuring devices in the UV/vis/NIR, solid multi-emitter systems for daily instrument performance control, and new standards for the relative determination of the fluorescence quantum yield, the key performance parameter of all emitters. The latter standards enable also performance Control of increasingly used integrating sphere setups. T2 - 15th International Symposium on Biological and Environmental Reference Materials CY - Berlin, Germany DA - 23.09.2018 KW - Fluorescence KW - Reference material KW - Quality assurance KW - Standardization KW - Quantum yield KW - Emission standard KW - Dye KW - Glass KW - Calibration slide KW - Instrument performance validation PY - 2018 AN - OPUS4-46390 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute T1 - Introduction to Fluorescence Spectroscopy N2 - A brief introduction to fluorescence spectroscopy will be provided, ranging from typically measured fluorescence quantities over instrument-specific contributions to measured fluorescence signals to selected applications. In this context, an overview of the photoluminescence properties of molecular and nanoscale luminescence reporters will be given including a brief insight into their photophysics and fluorescence standards designed by division Biophotonics for the calibration and instrument performance validation of fluorescence measuring devices will be presented. T2 - Analytical Academy CY - Berlin, Germany DA - 13.01.2020 KW - Linearity KW - Fluorescence KW - Dye KW - Quality assurance KW - Nnano particle KW - Method KW - Measurement uncertainty KW - Quantification PY - 2020 AN - OPUS4-51618 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -