TY - JOUR A1 - Camplese, D. A1 - Chianese, C. A1 - Scarponi, G. A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, V. T1 - Analysis of high temperature degradation of multi-layer insulation (MLI) systems for liquid hydrogen storage tanks N2 - The interest in hydrogen-based green energy is increasing worldwide, and the same is true for hydrogen-powered vehicles. Among the possible solutions to store hydrogen in such vehicles, cryogenic tanks equipped with multi-layer insulation (MLI) are the most promising to increase the amount of energy stored per unit volume. However, MLI is affected by severe deterioration when exposed to an external source of heat such as a fire following a car accident, leaving the tank unprotected and leading to failure in a relatively short time. In this work, a one-dimensional model to evaluate MLI thermal degradation when a liquid hydrogen tank is exposed to fire is presented. The relevance of taking MLI degradation into account when simulating the pressure increase due to external fire exposure is here demonstrated through the analysis of several case studies. The results show that MLI systems performance depletes within a few minutes of exposure to hydrocarbon poolfire. T2 - ICheaP 16 CY - Naples, Italy DA - 21.05.2023 KW - LH2 KW - MLI KW - Tiefkalt KW - Fire KW - Tank PY - 2023 SN - 2283-9216 VL - 2023 SP - 1 EP - 6 PB - AIDIC Servizi S.r.l. AN - OPUS4-57584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Camplese, Davide A1 - Cozzolino, Chiara A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Otremba, Frank A1 - Cozzani, Valerio T1 - Safety Assessment of MLI Super-Insulation Systems for Cryogenic Liquid-Hydrogen Tanks in Fire Scenarios N2 - In the context of green energy transition, cryogenic tanks insulated by MLI and vacuum are emerging as a leading solution to store hydrogen in heavy-duty vehicles. However, the integrity of such tanks can be jeopardized by fire. In such a scenario, MLI materials degradation can occur, leaving the tank unprotected from the fire heat flux, with consequent rapid pressurization and a high risk of failure. This study presents a safety assessment of non-combustible MLI under fire exposure based on the estimation of the time to mechanical failure of the equipment. This is calculated through an innovative model that simulates the thermomechanical response of the tank, including the MLI thermal degradation and the pressure-relief valve (PRV) operation. The application to several case studies that consider a typical LH2 tank featuring a wide range of MLI configurations demonstrated the likelihood of failure in case of exposure to a hydrocarbon pool fire, providing also comprehensive insights into the impact of the insulation characteristics and operating conditions on the time to failure. T2 - Loss Prevention 2025 CY - Bologna, Italien DA - 09.06.2025 KW - LH2 KW - LNG KW - Fire KW - Insulation KW - Safety KW - Tank PY - 2025 DO - https://doi.org/10.3303/CET25116036 SN - 2283-9216 IS - 116 SP - 211 EP - 216 PB - AIDIC AN - OPUS4-63739 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Eberwein, Robert A1 - Heßmann, Jennifer A1 - Werner, Jan A1 - Scarponi, Giordano Emrys A1 - Cozzani, Valerio A1 - Otremba, Frank T1 - Investigation of Realistic Fire Scenarios Involving Cryogenic Storage Tanks N2 - The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences. T2 - Loss Prevention 2025 CY - Bologna, Italien DA - 09.06.2025 KW - LH2 KW - LNG KW - Fire KW - Tank KW - Safety PY - 2025 DO - https://doi.org/10.3303/CET25116031 SN - 2283-9216 IS - 116 SP - 181 EP - 186 PB - AIDIC AN - OPUS4-63738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schiaroli, Alice A1 - Camplese, Davide A1 - Scarponi, Giordano Emrys A1 - Eberwein, Robert A1 - Ustolin, Federico A1 - Cozzani, Valerio T1 - Modelling the behaviour of cryogenic liquid hydrogen tanks engulfed in fire N2 - The safe use of liquid hydrogen as a clean fuel requires a deep understanding of its behaviour in accident scenarios. Among other scenarios, the possible involvement of cryogenic liquid hydrogen tanks in engulfing fires is of particular concern, due to the potentially severe consequences. This study proposes a computational fluid dynamic model suitable to simulate the behaviour of liquid hydrogen tanks equipped with multi-layer insulation (MLI) engulfed in fire. An original approach has been developed to assess the progressive degradation of the performance of the thermal insulation, that is crucial in determining the tank pressurization and failure. The model is validated against full-scale experimental fire tests. The outcomes of the model reproduce the progressive pressurization and the opening time of the pressure relief valve within 2 % error. The results demonstrate the importance of accounting for the dynamic evolution of the progressive degradation of the insulation when evaluating tank pressurization, and they highlight the limitations of empirical, simplified state-of-the-art approaches. Furthermore, the analysis evidences the key role of the fire temperature in governing tank response, stressing the need for proper fire characterization to support reliable modelling of fire scenarios and the development of emergency planning and mitigation strategies ensuring the structural integrity of liquid hydrogen tanks during fire attacks. KW - LH2 KW - LNG KW - Fire KW - Tank PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-652920 DO - https://doi.org/10.1016/j.psep.2025.108319 SN - 0957-5820 VL - 206 SP - 1 EP - 14 PB - Elsevier Ltd. AN - OPUS4-65292 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sickfeld, Jürgen A1 - Schulze, Rolf-Dieter A1 - Raabe, Hans-Joachim T1 - Messung von Spannungen in Tankinnenbeschichtungen - Quellverhalten mit organischen Medien KW - Beschichtung, organisch KW - Tank KW - Spannung KW - Epocidharz KW - Quellverhalten PY - 1996 SN - 0014-7699 VL - 102 IS - 2 SP - 49 EP - 55 PB - Vincentz CY - Hannover AN - OPUS4-661 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wilrich, Cordula A1 - Wilrich, Thomas T1 - Explosion bei Tankinstandhaltung N2 - Bei Instandhaltungsarbeiten an einem Tank kam es – ohne Personenschaden – zu einer Explosion. Da als Ursache nur solche aus dem Obhuts- und Gefahrenbereich des mit der Instandhaltung beauftragten Dienstleisters und seines Subunternehmers in Frage kamen, mussten diese sich im Zuge einer Beweislastumkehr entlasten, d.h. sie mussten aufzeigen, dass sie nicht pflichtwidrig gehandelt haben. Das gelang ihnen nicht und das Gericht ging zur Begründung auch detailliert auf Technische Regeln zur Betriebssicherheit ein (was in Urteilsbegründungen eher selten vorkommt). Die Gefährdungsbeurteilung spielte dahingegen in der Urteilsbegründung keine Rolle. Dies zeigt wie unterschiedlich Juristen und Arbeitsschützer denken: Zur Klärung einer möglichen Haftung sind die Pflichtverletzung und der Kausalzusammenhang relevant, während für den Arbeitsschutz die Prävention im Vordergrund steht – vor allem die Gefährdungsbeurteilung und die daraus abgeleiteten Schutzmaßnahmen. KW - Arbeitsschutz KW - Technische Regeln für Betriebssicherheit KW - TRBS KW - Instandhaltung KW - Explosion KW - Tank PY - 2025 DO - https://doi.org/10.37307/j.2199-7349.2025.01.09 IS - 1 SP - 32 EP - 37 PB - Erich Schmidt Verlag (ESV) CY - Berlin AN - OPUS4-62380 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -