TY - JOUR A1 - Wu, Dejian A1 - Schmidt, Martin A1 - Krietsch, Arne A1 - Krause, U. T1 - Effect of oxygen concentration, inert gas and CH4/H2 addition on the minimum ignition energy of coal dusts JF - Journal of Loss Prevention in the Process Industries 77 (2022) 104772 N2 - MIKE III apparatus tests were conducted to investigate the minimum ignition energy (MIE) of coal dusts in air and O2/CO2 atmospheres with and without small amount of CH4/H2. The O2 mole fraction (XO2) in the gas mixtures varied from 21% to 50% with the CH4/H2 mole fraction from 0 to 2%. Experimental result showed that MIE of coal dusts significantly decreases even by three orders of magnitude in mJ with increasing XO2 and the addition of CH4/H2. Compared with CH4, H2 had a relatively strong promotion effect on the spark ignition of coal dusts. The inhibiting effect of CO2 was found to be much stronger than N2, but this inhibiting effect of CO2 could be eliminated by 9% increment of XO2. The effect on MIE of coal dusts thus followed by the order: 9% increment of XO2 > CO2 replacing N2 > 2% CH4 or H2 addition. Moreover, two empirical models were used to estimate the MIE of hybrid dust-gas mixture (HMIE), and the results showed that calculated data can well reflect the promoting effect of elevated XO2 and flammable gas addition, and the inhibiting effect of inert gas KW - Ignition energy KW - Hybrid mixture KW - Oxygen rich KW - Inerting effect KW - Empirical model PY - 2022 DO - https://doi.org/10.1016/j.jlp.2022.104772 SN - 0950-4230 VL - 77 SP - 1 EP - 10 PB - Elsevier Ltd. AN - OPUS4-55888 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhao, P. A1 - Schmidt, Martin A1 - Krause, U. A1 - Duan, Q. A1 - Krietsch, Arne A1 - Wu, Dejian T1 - Experimental study on the minimum explosion concentration of anthracite dust: The roles of O2 mole fraction, inert gas and CH4 addition JF - Jounal of Loss Prevention in the Process Industries N2 - The explosion characteristics of anthracite coal dust with/without small amount of CH4 (1.14 vol %) were investigated by using a 20 L spherical explosion apparatus with an emphasis on the roles of oxygen mole fraction and inert gas. Two methods based on overpressure and combustion duration time were used to determine the minimum explosion concentration (MEC) or the lower explosion limit (LEL) of the pure anthracite coal dust and the hybrid coal-methane mixtures, respectively. The experiment results showed that increasing oxygen mole fraction increases the explosion risk of coal dust: with increasing oxygen mole fraction, the explosion pressure (Pex) and the rate of explosion pressure rise ((dp/dt)ex)) increase, while MEC decreases. The explosion risk of anthracite dust was found to be lower after replacing N2 with CO2, suggesting that CO2 has a better inhibition effect on explosion mainly due to its higher specific heat. However, the addition of 1.14% CH4 moderates the inhibition effect of CO2 and the promotion effect of O2 on anthracite dust explosion for some extent, increasing explosion severity and reducing the MEC of anthracite dust. For hybrid anthracite/CH4 mixture explosions, Barknecht’s curve was found to be more accurate and conservative than Chatelier’s line, but neither are sufficient from the safety considerations. The experimental results provide a certain help for the explosion prevention and suppression in carbonaceous dust industries. KW - Lower explosion limit KW - Minimun explosion concentration KW - Explosion charasteristics KW - Hybrid mixture KW - Explosion regimes PY - 2021 DO - https://doi.org/10.1016/j.jlp.2021.104490 VL - 2021 SP - 1 EP - 10 PB - Elsevier Ltd. ET - 71 AN - OPUS4-54074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -