<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>63485</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Versatility of nitrogen microwave-induced plasma mass spectrometry in elemental and isotopic analysis</title>
    <abstract language="eng">The introduction of Nitrogen-based Microwave Inductively Coupled Atmospheric-Pressure Plasma Mass Spectrometry (MICAP-MS) addresses the necessity for a plasma source that matches the capabilities of traditional argon-based Inductively Coupled Plasma Mass Spectrometry (ICP-MS) while exploiting the availability and cost-effectiveness of nitrogen gas. MICAP-MS uses nitrogen plasma, offering significant advantages such as reduced operational costs and eliminating specific isobaric interferences common in argon plasma systems [1]. This presentation explores the principles of MICAP-MS, highlighting its similarities to conventional ICP-MS in terms of analytical performance while emphasizing unique benefits like eliminating interferences from argon-based polyatomic species. MICAP-MS exhibits robust performance using nitrogen gas of varying purities—including ultra-high purity and industrial-grade nitrogen—without compromising analytical results [2].&#13;
&#13;
We have applied MICAP-MS for multielement analysis in soil samples, serving as a proof of concept for environmental monitoring applications. The technique achieved figures of merit comparable to traditional ICP-MS, even when analyzing real-world samples with complex matrices [2]. MICAP-MS demonstrated high tolerance to high-concentration matrices, maintaining accuracy and precision without extensive sample preparation or matrix separation [3]. In clinical diagnostics, MICAP-MS was employed for the precise and traceable quantification of calcium, iron, and selenium in human serum using isotope dilution analysis [4]. These elements often face interferences in argon-based ICP-MS due to argon-associated isobaric interferences (40Ca+, 56Fe+, and 80Se+); however, MICAP-MS effectively overcomes these challenges, providing traceable and accurate determinations.&#13;
&#13;
The stability of the microwave plasma in MICAP-MS facilitates precise isotopic analysis. This capability investigated age-induced lithium isotope fractionation in lithium-ion batteries, offering critical insights into battery aging mechanisms and performance degradation [5]. MICAP-MS is a versatile analytical tool that combines the operational benefits of nitrogen plasma with the strengths of traditional ICP-MS. Its ability to handle complex matrices, reduce interferences, and perform precise elemental and isotopic analyses across various applications makes it a valuable instrument.</abstract>
    <enrichment key="eventName">European Winter Conference on Plasma Spectrochemistry</enrichment>
    <enrichment key="eventPlace">Berlin, Germany</enrichment>
    <enrichment key="eventStart">02.03.2025</enrichment>
    <enrichment key="eventEnd">07.03.2025</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>MICAP-MS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Nitrogen plasma</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope dilution analysis</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Matrix tolerance</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Argon interference elimination</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Trace analysis</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.6 Anorganische Referenzmaterialien und Gasanalytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
</export-example>
