    <title language="eng">On-line monitoring of polyhydroxyalkanoate extraction by low-field nuclear magnetic resonance spectroscopy</title>
    <abstract language="eng">The use of low-field nuclear magnetic resonance (NMR) spectroscopy enables real-time reaction monitoring in contrast to time-consuming gas chromatography or off-line high-field NMR measurements. In this study, NMR spectroscopy is demonstrated as a novel process analytical technology (PAT) tool in the downstream processing of polyhydroxyalkanoate (PHA) biopolymers. On-line NMR spectroscopy measurements were performed using a Spinsolve 43 Carbon Ultra instrument in a fully automated mode with a flow-assembly based on PTFE tubing. Single-scan NMR spectra were acquired for real-time monitoring of the extraction process of the PHA copolymer poly(hydroxybutyrate-co-hydroxyhexanoate) with 13.5 mol.% hydroxyhexanoate [P(HB-co-13.5 mol.%HHx)] from Ralstonia eutropha biomass using chloroform or acetone as PHA solvents at lyophilized cell loadings of 20–120 g L􀀀 1. The reproducibility and reliability of low-field NMR spectroscopy was comparable to high-field NMR spectroscopy, with superior performance in terms of time. The correlation between the results of on-line monitoring using low-field NMR spectroscopy and off-line analysis using gas chromatography (GC) showed a correlation coefficient of &gt;94 %. The versatility of low-field NMR spectroscopy for elucidating reaction kinetics, facilitating endpoint determination and accelerating extraction processes by maximizing solubility is highlighted as plateau values were reached within 6–10 min for chloroform and acetone, respectively. This novel low-field NMR spectroscopy application promotes a new monitoring approach for downstream PHA processing and supports process development and optimization.</abstract>
    <parentTitle language="eng">Polymer Degradation and Stability</parentTitle>
    <identifier type="doi">10.1016/j.polymdegradstab.2025.111188</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-624215</identifier>
    <identifier type="issn">1873-2321</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">25.08.2025</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Isabel Thiele</author>
    <author>Björn Weiske</author>
    <author>Sebastian L. Riedel</author>
    <author>Klas Meyer</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Polyhydroxyalkanoate</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Extraction</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>NMR</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ralstonia eutropha</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Downstream processing</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="660">Chemische Verfahrenstechnik</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.4 Non-Target-Analytik</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="themenfelder" number="">Anlagensicherheit und Prozesssimulation</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/62421/1-s2.0-S0141813024009917-main.pdf</file>
  </doc>
</export-example>