<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>43538</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">New approaches in isotope analysis - molecular absorption spectrometry</title>
    <abstract language="eng">Variations in the isotope amount composition of some elements like lithium, boron, magnesium, calcium and copper have been used as proof of provenance of a sample and to describe geological processes. Routinely, isotope compositions are determinate by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time consuming and they require a high qualified analysist.&#13;
 &#13;
Here an alternative faster and low cost optical method for isotope ratio determination is proposed: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X= Li, B, Mg, Ca, Cu and Sr have been determined by monitoring the absorption spectrum of their monohydride (XH) in graphite furnace HR-CS-MAS.</abstract>
    <enrichment key="eventName">Seminar at Princeton University</enrichment>
    <enrichment key="eventPlace">Princeton, NJ, USA</enrichment>
    <enrichment key="eventStart">16.10.2017</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <author>Carlos Enrique Abad Andrade</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>High-Resolution Continuum Source Molecular Absorption Spectrometry</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>HR-CS-MAS</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotopic shift</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Graphite furnace</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Isotope ratio</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
</export-example>
