<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>42982</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Trace element analysis of airborne particulate matter with TXRF and SR-TXRF-XANES</title>
    <abstract language="eng">Airborne particulate matter is a topic of growing  interest.  Particles with aerodynamic diameters less than 10 μm (PM 10) and especially the fine fraction below 2.5 μm (PM2.5) are of particular  importance, as they  can enter the human respiratory system and cause  acute  and  &#13;
chronic respiratory or cardiovascular diseases. The mass distribution of airborne particles in dependence of their  diameters is well-known, but also the abundance and temporal variation of trace elements in air (mass  concentrations down to the pg/m³ range) are crucial.  &#13;
&#13;
These elements originate from various natural (abrasion, erosion) and anthropogenic sources (combustion,  road  traffic),  which  complicate  the  discrimination  between  harmless  and  toxic  emissions.  Some  new  methods  of  investigation  are  therefore  needed  and  X-ray  fluorescence  spectroscopy  has  ascertained  ist  huge  potential  in  this  matter,  thanks  to  the  possibility  to  determine  simultaneously,  in  a  time-resolved  manner,  the  mass  concentrations  of critical  elements which can be considered as markers of a potential toxic source. A  method  for  the  quantitative Analysis  of  airborne  particles  directly  collected  on  sample substrates (30 mm  quartz  reflectors  and  1"  Si  wafers suited  for  total-reflection  X-ray fluorescence analysis  (TXRF)  will  be  presented.&#13;
&#13;
Samplings  were  performed  using  a  three- stage  Dekati™  PM10  impactor  (&gt;10 μm,  2.5  to  10 μm  and  1  to  2.5 μm)  and  a four-stage Sioutas Personal Cascade Impactor (&gt;2.5 μm, 1 to 2.5 μm,0.5 to   1 μm and 0.25 to 0.5 μm) at indoor  and  outdoor  sites  at the Atominstitut (Vienna,  Austria).  Quantitative  results  of  two   outdoor  test  sampling  campaigns  (July  2016  and  January  2017) will  be  presented  and   discussed. Low detection limits were assessed via TXRF and range from several 10 to several 100 pg/m³ depending on the element and particle size fraction.</abstract>
    <enrichment key="eventName">Denver X-ray Conference</enrichment>
    <enrichment key="eventPlace">Big Sky, Montana, USA</enrichment>
    <enrichment key="eventStart">31.07.2017</enrichment>
    <enrichment key="eventEnd">04.08.2017</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <author>J. Prost</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>XANES</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Synchrotron</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>TXRF</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>BAMline</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
  </doc>
</export-example>
