<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>42257</id>
    <completedYear/>
    <publishedYear>2017</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>8437</pageFirst>
    <pageLast>8444</pageLast>
    <pageNumber/>
    <edition/>
    <issue>16</issue>
    <volume>89</volume>
    <type>article</type>
    <publisherName>American Chemical Society</publisherName>
    <publisherPlace>Washington, D.C., USA</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Optical pH Sensor Covering the Range from pH 0−14 Compatible with Mobile-Device Readout and Based on a Set of Rationally Designed Indicator Dyes</title>
    <abstract language="eng">In this work, a family of pH-responsive fluorescent probes has been designed in a rational manner with the aid of quantum chemistry tools, covering the entire pH range from 0−14. Relying on the boron−dipyrromethene (BODIPY) core, all the probes as well as selected reference dyes display very similar spectroscopic properties with ON−OFF fluorescence switching responses, facilitating optical readout in simple devices used for detection and analysis. Embedding of the probes and reference dyes into hydrogel spots on a plastic strip yielded a test strip that reversibly indicates pH with a considerably small uncertainty of ~0.1 pH units. These strips are not only reusable but, combined with a 3D-printed case that can be attached to a smartphone, the USB port of which drives the integrated LED used for excitation, allows for autonomous operation in on-site or in-the-field applications; the developed Android application software (“app”) further simplifies operation for unskilled users.</abstract>
    <parentTitle language="eng">Analytical Chemistry</parentTitle>
    <identifier type="doi">10.1021/acs.analchem.7b01903</identifier>
    <identifier type="issn">0003-2700</identifier>
    <identifier type="issn">1520-6882</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-422571</identifier>
    <enrichment key="date_peer_review">04.10.2017</enrichment>
    <licence>Creative Commons - Namensnennung - Nicht kommerziell - Keine Bearbeitung 3.0</licence>
    <author>Raul Gotor</author>
    <author>Pichandi Ashokkumar</author>
    <author>Mandy Hecht</author>
    <author>Karin Keil</author>
    <author>Knut Rurack</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>pH measurement</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>BODIPY</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Smartphone</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Test strip</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <file>https://opus4.kobv.de/opus4-bam/files/42257/AnalChem_2017_89_8437-8444.pdf</file>
  </doc>
</export-example>
