<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>18674</id>
    <completedYear/>
    <publishedYear>2009</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>84</pageFirst>
    <pageLast>88</pageLast>
    <pageNumber/>
    <edition/>
    <issue>1</issue>
    <volume>28</volume>
    <type>article</type>
    <publisherName>Elsevier Science</publisherName>
    <publisherPlace>Amsterdam [u.a.]</publisherPlace>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Monitoring the vulcanization of elastomers: Comparison of curemeter and ultrasonic online control</title>
    <abstract language="eng">The vulcanization of elastomeric materials has a high impact on the properties of the final product. Therefore, it is important to monitor and control this crosslinking process. A common technique to attain the necessary curing time is the use of a curemeter in accordance with ISO 6502 in order to determine the time for full cure of a sample with a standardized geometry. Based on this result and a lot of practical experience, the required curing time for a given product geometry is estimated. Within the scope of this work, a new analysis technique will be compared with the standard procedure. The ultrasonic online control employs ultrasound waves to measure the changes in material properties caused by vulcanization. For this study, a natural rubber compound with a conventional curing system was investigated by both techniques. It was found that the results of the ultrasonic technique show good agreement with the results of the curemeter.</abstract>
    <parentTitle language="eng">Polymer testing</parentTitle>
    <identifier type="old">20835</identifier>
    <identifier type="doi">10.1016/j.polymertesting.2008.11.005</identifier>
    <identifier type="issn">0142-9418</identifier>
    <enrichment key="bibliotheksstandort">Sonderstandort: Publica-Schrank</enrichment>
    <enrichment key="date_peer_review">15.01.2009</enrichment>
    <enrichment key="CrossDepartmentPublication">0</enrichment>
    <author>Matthias Jaunich</author>
    <author>Wolfgang Stark</author>
    <author>B. Hoster</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cure process</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Ultrasound</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Curemeter</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Elastomer</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Vulcanization</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Online control</value>
    </subject>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")</collection>
  </doc>