<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>55803</id>
    <completedYear/>
    <publishedYear>2022</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>3</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>article</type>
    <publisherName>Royal Society of Chemistry</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Importance of physical units in the Boltzmann plot method</title>
    <abstract language="eng">The Boltzmann plot is one of the most widely used methods for determining the temperature in different types of laboratory plasmas. It operates on the logarithm as a function of the dimensional argument, which assumes that the correct physical units are used. In many works using the Boltzmann method, there is no analysis of the dimension of this argument, which may be the cause of a potential error. This technical note offers a brief description of the method and shows how to correctly use physical units when using transcendental functions like the logarithm.</abstract>
    <parentTitle language="eng">Journal of Analytical Atomic Spectrometry</parentTitle>
    <identifier type="doi">10.1039/d2ja00241h</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-558039</identifier>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">05.10.2022</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Tobias Völker</author>
    <author>Igor B. Gornushkin</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Boltzmann plot</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Laser induced plasma</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.3 Instrumentelle Analytik</collection>
    <collection role="institutes" number="">8 Zerstörungsfreie Prüfung</collection>
    <collection role="institutes" number="">8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/55803/Units JAAS 2022.pdf</file>
  </doc>
</export-example>
