<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>62712</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Using Dual Fluorescent Molecularly Imprinted Particles Coupled with a Miniaturized Opto-Microfluidic Platform for On-Site Detection of Perfluoroalkyl Carboxylic Acids</title>
    <abstract language="eng">Per- and polyfluoroalkyl substances (PFAS) are a group of synthetic organofluorine chemicals widely used in the production of various materials, including firefighting foams, adhesives, and coatings that resist stains and oil. In recent years, PFAS have gained attention as emerging environmental contaminants, with particular emphasis on perfluoroalkyl carboxylic acids (PFCAs), the most common type of PFAS. PFCAs are defined by a fully fluorinated carbon chain and a charged carboxylic acid group. They have been classified as Substances of Very High Concern and included in the REACH Candidate List due to their persistence, resistance to biodegradation, and toxicological impacts.&#13;
Traditional methods for analyzing PFCAs, like GC-MS, HRMS, and HPLC-based techniques, are time-consuming, non-portable, expensive, and require specialized expertise. On the other hand, fluorescence assays offer a user-friendly, portable, and cost-effective alternative with high sensitivity and quick results, particularly when the binding of the analyte causes a specific increase in the probe’s fluorescence. Combining these probes with a carrier platform and a miniaturized optofluidic device presents a promising approach for PFCA monitoring.&#13;
In this study, a new guanidine BODIPY fluorescent indicator monomer was synthesized, characterized, and incorporated into a molecularly imprinted polymer (MIP) designed for the specific detection of perfluorooctanoic acid (PFOA). The MIP layer was formed on silica core nanoparticles doped with tris(bipyridine)ruthenium(II) chloride, serving as an optical internal reference for calibration-free assays. In combination with an extraction step prior to sample analysis, this system enables selective and reliable detection of PFCAs in surface water samples, minimizing interference from competing substances, matrix effects, and other factors. When integrated into an opto-microfluidic setup, the assay provided a compact, user-friendly detection system capable of detecting micromolar levels of PFOA in under 15 minutes from surface water samples.</abstract>
    <enrichment key="eventName">ANAKON2025</enrichment>
    <enrichment key="eventPlace">Leipzig, Germany</enrichment>
    <enrichment key="eventStart">10.03.2025</enrichment>
    <enrichment key="eventEnd">13.03.2025</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Kornelia Gawlitza</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Perfluorooctanoic Acid (PFOA)</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>On-site detection</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fluorescence</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Microfluidics</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Molecularly Imprinted Polymers</value>
    </subject>
    <collection role="ddc" number="543">Analytische Chemie</collection>
    <collection role="ddc" number="620">Ingenieurwissenschaften und zugeordnete Tätigkeiten</collection>
    <collection role="institutes" number="">1 Analytische Chemie; Referenzmaterialien</collection>
    <collection role="institutes" number="">1.9 Chemische und optische Sensorik</collection>
    <collection role="themenfelder" number="">Umwelt</collection>
    <collection role="themenfelder" number="">Material</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="themenfelder" number="">Chemische Charakterisierung und Spurenanalytik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="themenfelder" number="">Advanced Materials</collection>
    <collection role="themenfelder" number="">Sensorik</collection>
  </doc>
</export-example>
