<?xml version="1.0" encoding="utf-8"?>
<export-example>
  <doc>
    <id>63739</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>211</pageFirst>
    <pageLast>216</pageLast>
    <pageNumber/>
    <edition/>
    <issue>116</issue>
    <volume/>
    <type>article</type>
    <publisherName>AIDIC</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Safety Assessment of MLI Super-Insulation Systems for Cryogenic Liquid-Hydrogen Tanks in Fire Scenarios</title>
    <abstract language="eng">In the context of green energy transition, cryogenic tanks insulated by MLI and vacuum are emerging as a leading solution to store hydrogen in heavy-duty vehicles. However, the integrity of such tanks can be jeopardized by fire. In such a scenario, MLI materials degradation can occur, leaving the tank unprotected from the fire heat flux, with consequent rapid pressurization and a high risk of failure. This study presents a safety assessment of non-combustible MLI under fire exposure based on the estimation of the time to mechanical failure of the equipment. This is calculated through an innovative model that simulates the thermomechanical response of the tank, including the MLI thermal degradation and the pressure-relief valve (PRV) operation. The application to several case studies that consider a typical LH2 tank featuring a wide range of MLI configurations demonstrated the likelihood of failure in case of exposure to a hydrocarbon pool fire, providing also comprehensive insights into the impact of the insulation characteristics and operating conditions on the time to&#13;
failure.</abstract>
    <parentTitle language="eng">Chemical Engineering Transactions</parentTitle>
    <identifier type="issn">2283-9216</identifier>
    <identifier type="doi">10.3303/CET25116036</identifier>
    <enrichment key="eventName">Loss Prevention 2025</enrichment>
    <enrichment key="eventPlace">Bologna, Italien</enrichment>
    <enrichment key="eventStart">09.06.2025</enrichment>
    <enrichment key="eventEnd">11.06.2025</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Davide Camplese</author>
    <author>Chiara Cozzolino</author>
    <author>Giordano Emrys Scarponi</author>
    <author>Robert Eberwein</author>
    <author>Frank Otremba</author>
    <author>Valerio Cozzani</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Safety</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tank</value>
    </subject>
    <collection role="ddc" number="604">Spezielle Themen</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
  </doc>
  <doc>
    <id>63425</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Investigation of realistic fire scenarios involving cryogenic storage tanks</title>
    <abstract language="eng">The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences.</abstract>
    <enrichment key="eventName">18th EFCE International Symposium on Loss Prevention and Safety Promotion in the Process Industries</enrichment>
    <enrichment key="eventPlace">Bologna, Italy</enrichment>
    <enrichment key="eventStart">08.06.2025</enrichment>
    <enrichment key="eventEnd">11.06.2025</enrichment>
    <enrichment key="InvitedTalks">1</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Robert Eberwein</author>
    <author>Jennifer Heßmann</author>
    <author>Jan Werner</author>
    <author>Giordano Emrys Scarponi</author>
    <author>Valerio Cozzani</author>
    <author>Frank Otremba</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Liquefied Natural Gas</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Safety</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
  </doc>
  <doc>
    <id>63686</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>deu</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="deu">Forschung zum Thema Feuer an der BAM</title>
    <abstract language="deu">Feuer und deren Auswirkung stellen ein Querschnittsthema über die Aktivitätsfelder der BAM dar. Schwerpunkte stellen dabei Brände in Gebäuden, Industrieanlagen und Lagerräumen, der Vegetation, an Fahrzeugen und Tanks sowie Brände im Zusammenhang mit neuen Energieträgern dar. Im Vortrag werden die einzelnen Themen und exemplarische für deren Erforschung nutzbare Infrastruktur vorgestellt.</abstract>
    <enrichment key="eventName">Transfer on Fire 2</enrichment>
    <enrichment key="eventPlace">Luckenwalde, Germany</enrichment>
    <enrichment key="eventStart">10.07.2025</enrichment>
    <enrichment key="eventEnd">10.07.2025</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Robert Eberwein</author>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Feuer</value>
    </subject>
    <subject>
      <language>deu</language>
      <type>uncontrolled</type>
      <value>Brandlasten</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Verkehrsinfrastrukturen</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
  </doc>
  <doc>
    <id>65292</id>
    <completedYear/>
    <publishedYear>2026</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>1</pageFirst>
    <pageLast>14</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>206</volume>
    <type>article</type>
    <publisherName>Elsevier Ltd.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Modelling the behaviour of cryogenic liquid hydrogen tanks engulfed in fire</title>
    <abstract language="eng">The safe use of liquid hydrogen as a clean fuel requires a deep understanding of its behaviour in accident scenarios. Among other scenarios, the possible involvement of cryogenic liquid hydrogen tanks in engulfing fires is of particular concern, due to the potentially severe consequences. This study proposes a computational fluid dynamic model suitable to simulate the behaviour of liquid hydrogen tanks equipped with multi-layer insulation (MLI) engulfed in fire. An original approach has been developed to assess the progressive degradation of the performance of the thermal insulation, that is crucial in determining the tank pressurization and failure. The model is validated against full-scale experimental fire tests. The outcomes of the model reproduce the progressive pressurization and the opening time of the pressure relief valve within 2 % error. The results demonstrate the importance of accounting for the dynamic evolution of the progressive degradation of the insulation when evaluating tank pressurization, and they highlight the limitations of empirical, simplified state-of-the-art approaches. Furthermore, the analysis evidences the key role of the fire temperature in governing tank response, stressing the need for proper fire characterization to support reliable modelling of fire scenarios and the development of emergency planning and mitigation strategies ensuring the structural integrity of liquid hydrogen tanks during fire attacks.</abstract>
    <parentTitle language="eng">Process Safety and Environmental Protection</parentTitle>
    <identifier type="issn">0957-5820</identifier>
    <identifier type="doi">10.1016/j.psep.2025.108319</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-652920</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="local_crossrefLicence">https://www.elsevier.com/tdm/userlicense/1.0/</enrichment>
    <enrichment key="local_import_origin">crossref</enrichment>
    <enrichment key="local_doiImportPopulated">PersonAuthorFirstName_1,PersonAuthorLastName_1,PersonAuthorIdentifierOrcid_1,PersonAuthorFirstName_2,PersonAuthorLastName_2,PersonAuthorIdentifierOrcid_2,PersonAuthorFirstName_3,PersonAuthorLastName_3,PersonAuthorIdentifierOrcid_3,PersonAuthorFirstName_4,PersonAuthorLastName_4,PersonAuthorIdentifierOrcid_4,PersonAuthorFirstName_5,PersonAuthorLastName_5,PersonAuthorFirstName_6,PersonAuthorLastName_6,PersonAuthorIdentifierOrcid_6,PublisherName,TitleMain_1,Language,TitleParent_1,ArticleNumber,Volume,PublishedYear,IdentifierIssn,Enrichmentlocal_crossrefLicence</enrichment>
    <enrichment key="opus.source">doi-import</enrichment>
    <enrichment key="date_peer_review">12.01.2026</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Alice Schiaroli</author>
    <author>Davide Camplese</author>
    <author>Giordano Emrys Scarponi</author>
    <author>Robert Eberwein</author>
    <author>Federico Ustolin</author>
    <author>Valerio Cozzani</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tank</value>
    </subject>
    <collection role="ddc" number="604">Spezielle Themen</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Verkehrsinfrastrukturen</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/65292/Schiaroli_2026_Modelling_LH2_Tanks_engulfed_in_fire.pdf</file>
  </doc>
  <doc>
    <id>63427</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Safety assessment of MLI super-insulation systems for cryogenic liquid-hydrogen tanks in fire scenarios</title>
    <abstract language="eng">In the context of green energy transition, cryogenic tanks featuring MLI systems are emerging as a leading solution to store hydrogen in heavy-duty vehicles. However, the integrity of such tanks can be jeopardized by fire. In such a scenario, MLI materials degradation can occur, leaving the tank unprotected from the fire heat flux, with consequent rapid pressurization and a high risk of failure. This study presents an assessment of aluminum-based MLI for liquid hydrogen cryogenic tanks under fire exposure based on the estimation of the time to mechanical failure of the equipment. This is calculated through an innovative model that simulates the thermomechanical response of the tank, including the MLI thermal degradation and the pressure-relief valve (PRV) operation. The application to several case studies that consider a typical LH2 tank featuring a wide range of MLI configurations demonstrated the likelihood of failure in case of exposure to a hydrocarbon pool fire, providing also comprehensive insights into the impact of the insulation characteristics and operating conditions on the time to failure.</abstract>
    <enrichment key="eventName">18th EFCE International Symposium on Loss Prevention and Safety Promotion in the Process Industries</enrichment>
    <enrichment key="eventPlace">Bologna, Italy</enrichment>
    <enrichment key="eventStart">08.06.2025</enrichment>
    <enrichment key="eventEnd">11.06.2025</enrichment>
    <enrichment key="InvitedTalks">1</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Davide Camplese</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tanks</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
  </doc>
  <doc>
    <id>63084</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>537</pageFirst>
    <pageLast>552</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume>135</volume>
    <type>article</type>
    <publisherName>Elsevier Ltd.</publisherName>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>1</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Comparative performance assessment of multilayer insulation (MLI) systems for liquid hydrogen vessels in fire scenarios</title>
    <abstract language="eng">Multilayer Insulation (MLI) systems are a mature technology for cryogenic liquid hydrogen (LH2) tank thermal insulation. Recent tests evidenced that MLI materials may be damaged when exposed to fire, resulting in critical safety issues in the case of accidents. Thus, an innovative approach to the performance assessment of aluminum and polyester-based MLIs for LH2 tanks in fire scenarios was developed. A specific model integrating the  hightemperature degradation of MLIs and the thermodynamic modeling of the tank lading was coupled to specific key performance indicators. Results of the analysis applied to a vehicle-scale tank equipped with 80 MLI layers indicate that MLI degradation and consequent tank failure may occur in less than 20 min for external shell temperatures above 1160 K in the presence of full engulfment, regardless of insulation used. Conversely, degradation does not occur earlier than 3600s below 603 and 928 K for polyester and aluminum-based MLI, respectively.</abstract>
    <parentTitle language="eng">International Journal of Hydrogen Energy</parentTitle>
    <identifier type="doi">10.1016/j.ijhydene.2025.04.534</identifier>
    <identifier type="issn">0360-3199</identifier>
    <identifier type="urn">urn:nbn:de:kobv:b43-630841</identifier>
    <enrichment key="opus_doi_flag">true</enrichment>
    <enrichment key="opus_import_data">{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,11]],"date-time":"2025-05-11T03:40:05Z","timestamp":1746934805122,"version":"3.40.5"},"reference-count":77,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T00:00:00Z","timestamp":1748736000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T00:00:00Z","timestamp":1746144000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100021856","name":"Ministero dell&amp;apos;Universit\u00e0 e della Ricerca","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100021856","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003407","name":"Ministero dell\u2019Istruzione, dell\u2019Universit\u00e0 e della Ricerca","doi-asserted-by":"publisher","award":["PE00000021","CUPJ33C22002890007"],"id":[{"id":"10.13039\/501100003407","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["International Journal of Hydrogen Energy"],"published-print":{"date-parts":[[2025,6]]},"DOI":"10.1016\/j.ijhydene.2025.04.534","type":"journal-article","created":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T11:27:33Z","timestamp":1746790053000},"page":"537-552","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Comparative performance assessment of multilayer insulation (MLI) systems for liquid hydrogen vessels in fire scenarios"],"prefix":"10.1016","volume":"135","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-4957-2039","authenticated-orcid":false,"given":"Davide","family":"Camplese","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5187-597X","authenticated-orcid":false,"given":"Giordano Emrys","family":"Scarponi","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3134-7456","authenticated-orcid":false,"given":"Robert","family":"Eberwein","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0009-0003-7800-4407","authenticated-orcid":false,"given":"Aliasghar","family":"Hajhariri","sequence":"additional","affiliation":[]},{"given":"Frank","family":"Otremba","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4680-535X","authenticated-orcid":false,"given":"Valerio","family":"Cozzani","sequence":"additional","affiliation":[]}],"member":"78","reference":[{"key":"10.1016\/j.ijhydene.2025.04.534_bib1","doi-asserted-by":"crossref","first-page":"8482","DOI":"10.1016\/j.ijhydene.2014.03.174","article-title":"Perspective on hydrogen energy carrier and its automotive applications","volume":"39","author":"Cipriani","year":"2014","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib2","doi-asserted-by":"crossref","first-page":"10016","DOI":"10.1016\/j.ijhydene.2020.11.256","article-title":"Hydrogen in energy transition: a review","volume":"46","author":"Kova\u010d","year":"2021","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib3","first-page":"2012","article-title":"Cryo-compressed hydrogen storage cryogenic cluster day","volume":"28","author":"Kunze","year":"2012","journal-title":"Sept"},{"year":"2012","series-title":"Liquid hydrogen: fuel of the future","author":"Peschka","key":"10.1016\/j.ijhydene.2025.04.534_bib4"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib5","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.1016\/j.ijhydene.2024.01.093","article-title":"Review on the key technologies and future development of insulation structure for liquid hydrogen storage tanks","volume":"57","author":"Yin","year":"2024","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib6","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1051\/matecconf\/201824001019","article-title":"Influence of vacuum level on insulation thermal performance for LNG cryogenic road tankers","volume":"240","author":"Edward","year":"2018","journal-title":"MATEC Web Conf."},{"key":"10.1016\/j.ijhydene.2025.04.534_bib7","doi-asserted-by":"crossref","first-page":"13308","DOI":"10.1016\/j.ijhydene.2022.12.152","article-title":"Liquid hydrogen storage system for heavy duty trucks: configuration, performance, cost, and safety","volume":"48","author":"Ahluwalia","year":"2023","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib8","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1016\/j.ijhydene.2023.11.104","article-title":"Hazard footprint of alternative fuel storage concepts for hydrogen-powered urban buses","volume":"50","author":"Schiaroli","year":"2024","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pecs.2013.10.002","article-title":"Recent advances in understanding of flammability characteristics of hydrogen","volume":"41","author":"S\u00e1nchez","year":"2014","journal-title":"Prog Energy Combust Sci"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib10","doi-asserted-by":"crossref","first-page":"17624","DOI":"10.1016\/j.ijhydene.2012.05.141","article-title":"Study on the harm effects of releases from liquid hydrogen tank by consequence modeling","volume":"37","author":"Li","year":"2012","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib11","doi-asserted-by":"crossref","first-page":"13705","DOI":"10.1016\/j.ijhydene.2022.11.302","article-title":"A review of hydrogen-air cloud explosions: the fundamentals, overpressure prediction methods, and influencing factors","volume":"48","author":"Hu","year":"2023","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib12","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/j.ijhydene.2024.07.077","article-title":"Investigation on the morphology and temperature distribution of hydrogen jet flames impinging on barrier walls","volume":"79","author":"Zhang","year":"2024","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib13","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.ijhydene.2024.07.053","article-title":"Experimental investigation on the development characteristics of high-pressure hydrogen jet flame under different ignition conditions","volume":"79","author":"Wu","year":"2024","journal-title":"Int J Hydrogen Energy"},{"year":"2013","series-title":"Domino effects in the process industries: modelling, prevention and managing","author":"Reniers","key":"10.1016\/j.ijhydene.2025.04.534_bib14"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib15","first-page":"2169","article-title":"Experimental examinations on the worst case behavior of LH2\/LNG tanks for passenger cars","author":"Pehr","year":"1996","journal-title":"Proc. 11th World Hydrog. Energy Conf. Stuttgart, Ger."},{"key":"10.1016\/j.ijhydene.2025.04.534_bib16","first-page":"547","article-title":"Medium-scale tests to investigate the possibility and effects of BLEVEs of storage vessels containing liquified hydrogen","volume":"90","author":"van Wingerden","year":"2022","journal-title":"Chem Eng Trans"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib17","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1016\/j.jhazmat.2006.09.056","article-title":"The boiling liquid expanding vapour explosion (BLEVE): mechanism, consequence assessment, management","volume":"141","author":"Abbasi","year":"2007","journal-title":"J Hazard Mater"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib18","first-page":"2338","article-title":"Hydrogen fuel tank fire exposure burst test","author":"Zalosh","year":"2005","journal-title":"SAE Trans"},{"year":"2023","series-title":"Insulation materials used in tanks for the storage of cryogenic fluids in fire scenarios","author":"Eberwein","key":"10.1016\/j.ijhydene.2025.04.534_bib19"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib20","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.psep.2024.04.131","article-title":"Experimental investigation on the behavior of thermal super insulation materials for cryogenic storage tanks in fire incidents","volume":"187","author":"Eberwein","year":"2024","journal-title":"Process Saf Environ Prot"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib21","article-title":"Experimental research of A tank for A cryogenic fluid with A wall rupture in A fire scenario","author":"Eberwein","year":"2024","journal-title":"15th ISHPMIE, Naples"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib22","first-page":"307","article-title":"Lumped model for the assessment of the thermal and mechanical response of LNG tanks exposed to fire","volume":"53","author":"Scarponi","year":"2016","journal-title":"Chem Eng Trans"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib23","first-page":"535","article-title":"Cryogenic hydrogen storage tanks exposed to fires: a CFD study","volume":"90","author":"Ustolin","year":"2022","journal-title":"Chem Eng Trans"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib24","doi-asserted-by":"crossref","first-page":"1169","DOI":"10.1016\/j.psep.2024.04.061","article-title":"Modeling the performance of multilayer insulation in cryogenic tanks undergoing external fire scenarios","volume":"186","author":"Camplese","year":"2024","journal-title":"Process Saf Environ Prot"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib25","article-title":"Non-combustible MLI based insulation behavior under fire condition - experimental and numerical investigation","author":"Hajhariri","year":"2024","journal-title":"Process Saf Environ Prot"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib26","first-page":"415","article-title":"Analysis of high temperature degradation of multi-layer insulation (MLI) systems for liquid hydrogen storage tanks","volume":"99","author":"Camplese","year":"2023","journal-title":"Chem Eng Trans"},{"year":"2019","series-title":"Standard guide for evacuated reflective insulation in cryogenic service","key":"10.1016\/j.ijhydene.2025.04.534_bib27"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib28","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.cryogenics.2017.11.004","article-title":"Cylindrical cryogenic calorimeter testing of six types of multilayer insulation systems","volume":"89","author":"Fesmire","year":"2018","journal-title":"Cryogenics"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib29","doi-asserted-by":"crossref","first-page":"9267","DOI":"10.3390\/en15249267","article-title":"Study on the performance of variable density multilayer insulation in liquid hydrogen temperature region","volume":"15","author":"Li","year":"2022","journal-title":"Energies"},{"year":"2001","series-title":"Large-scale liquid hydrogen testing of variable density multilayer insulation with a foam substrate","author":"Martin","key":"10.1016\/j.ijhydene.2025.04.534_bib30"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib31","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.phpro.2015.06.205","article-title":"Standardization in cryogenic insulation systems testing and performance data","volume":"67","author":"Fesmire","year":"2015","journal-title":"Phys Procedia"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib32","doi-asserted-by":"crossref","first-page":"7088","DOI":"10.1016\/j.ijhydene.2019.12.110","article-title":"Modeling and optimization of composite thermal insulation system with HGMs and VDMLI for liquid hydrogen on orbit storage","volume":"45","author":"Wang","year":"2020","journal-title":"Int J Hydrogen Energy"},{"year":"2003","series-title":"Spray bar zero-gravity vent system for on-orbit liquid hydrogen storage","author":"Hastings","key":"10.1016\/j.ijhydene.2025.04.534_bib33"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib34","unstructured":"International Organization for Standardization (ISO). ISO 13985:2006 \u2013 Liquid hydrogen \u2014 Land vehicle fuel tanks. Geneva, Switzerland: ISO; 2006."},{"volume":"II","article-title":"Agreement concerning the international carriage of dangerous goods by road (ADR)","year":"2020","key":"10.1016\/j.ijhydene.2025.04.534_bib35"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib36","first-page":"1","article-title":"Standard guide for thermal performance testing of cryogenic insulation systems","volume":"13","year":"2013","journal-title":"ASTM Int"},{"year":"2013","series-title":"GTR 13 Global technical regulation on hydrogen and fuel cell vehicles","key":"10.1016\/j.ijhydene.2025.04.534_bib37"},{"year":"2019","series-title":"NIST chemistry WebBook 69","key":"10.1016\/j.ijhydene.2025.04.534_bib38"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib39","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/0304-3894(90)85066-C","article-title":"Pressure and temperature response of liquefied gases in containers and pressure vessels which are subjected to accidental heat input","volume":"25","author":"Dancer","year":"1990","journal-title":"J Hazard Mater"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib40","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1016\/j.jlp.2018.09.015","article-title":"LPG vessels exposed to fire: scale effects on pressure build-up","volume":"56","author":"Scarponi","year":"2018","journal-title":"J Loss Prev Process Ind"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib41","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/0304-3894(95)00157-3","article-title":"Liquid temperature stratification and its effect on BLEVEs and their hazards","volume":"48","author":"Birk","year":"1996","journal-title":"J Hazard Mater"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib42","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/0304-3894(88)87015-8","article-title":"Thermal response analysis of LPG tanks exposed to fire","volume":"20","author":"Aydemir","year":"1988","journal-title":"J Hazard Mater"},{"year":"2005","series-title":"TNO Yellow Book, Methods for the calculation of physical effects","author":"Van Den Bosh","key":"10.1016\/j.ijhydene.2025.04.534_bib43"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib44","doi-asserted-by":"crossref","first-page":"17118","DOI":"10.1016\/j.ijhydene.2016.06.254","article-title":"Correlations for calculating heat transfer of hydrogen pool boiling","volume":"41","author":"Wang","year":"2016","journal-title":"Int J Hydrogen Energy"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib45","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1002\/aic.690180606","article-title":"A general expression for the correlation of rates of transfer and other phenomena","volume":"18","author":"Churchill","year":"1972","journal-title":"AIChE J"},{"year":"2016","series-title":"Cryogenic vessels \u2014 pressure- relief accessories for cryogenic service Part 3 : sizing and capacity determination (ISO 21013-3:2016","key":"10.1016\/j.ijhydene.2025.04.534_bib53"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib46","doi-asserted-by":"crossref","first-page":"2498","DOI":"10.1021\/ie4033999","article-title":"Pure and Pseudo-pure fluid thermophysical property evaluation and the open-source thermophysical property library CoolProp","volume":"53","author":"Bell","year":"2014","journal-title":"Ind \\&amp; Eng Chem Res"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib47","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1063\/1.3160306","article-title":"Fundamental equations of state for parahydrogen, normal hydrogen, and orthohydrogen","volume":"38","author":"Leachman","year":"2009","journal-title":"J Phys Chem Ref Data"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib48","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/0304-3894(90)85067-D","article-title":"A study of the effect of the tank diameter on the thermal stratification in LPG tanks subjected to fire engulfment","volume":"25","author":"Hadjisophocleous","year":"1990","journal-title":"J Hazard Mater"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib49","first-page":"121","article-title":"Boiling liquid expanding vapour explosions (BLEVE); possible failure mechanisms and their consequences","volume":"147","author":"Venart","year":"2000","journal-title":"Inst Chem Eng Symp Ser"},{"year":"2019","series-title":"Cryogenic vessels \u2014 cryogenic insulation performance","key":"10.1016\/j.ijhydene.2025.04.534_bib50"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib51","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.3390\/en15031149","article-title":"Modelling of liquid hydrogen boil-off","volume":"15","author":"Al Ghafri","year":"2022","journal-title":"Energies"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib52","doi-asserted-by":"crossref","DOI":"10.1016\/j.oceaneng.2024.117173","article-title":"Experimental and numerical investigation of the influences of sloshing motion on the change in boil-off gas\/boil-off rate in a cryogenic liquid tank","volume":"298","author":"Jeon","year":"2024","journal-title":"Ocean Eng"},{"year":"2014","series-title":"Circular cylinders and pressure vessels stress analysis and design","author":"Vullo","key":"10.1016\/j.ijhydene.2025.04.534_bib54"},{"year":"2024","series-title":"Eurocode 3 - design of steel structures. Part 1-2: structural fire design","key":"10.1016\/j.ijhydene.2025.04.534_bib55"},{"year":"2023","series-title":"Determination of the resistance to hydrocarbon pool fires of fire protection materials and systems for pressure vessels (ISO Standard No. 21843:2023)","key":"10.1016\/j.ijhydene.2025.04.534_bib56"},{"year":"1980","series-title":"Numerical heat transfer and fluid flow\/Suhas V. Patankar","author":"Patankar","key":"10.1016\/j.ijhydene.2025.04.534_bib57"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib63","unstructured":"European Committee for Standardization (CEN). EN 1993-1-4:2006 \u2013 Eurocode 3: Design of steel structures \u2013 Part 1-4: General rules \u2013 Supplementary rules for stainless steels. Brussels, Belgium: CEN; 2006."},{"year":"2022","series-title":"Cryogenic vessels \u2014 static vacuum insulated vessels","key":"10.1016\/j.ijhydene.2025.04.534_bib60"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib58","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.oceaneng.2019.05.028","article-title":"Inherent safety assessment of alternative technologies for LNG ships bunkering","volume":"185","author":"Iannaccone","year":"2019","journal-title":"Ocean Eng"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib59","first-page":"1","article-title":"Standard practice for evacuated reflective insulation in cryogenic service 1","volume":"82","year":"2015","journal-title":"Astm"},{"year":"2015","series-title":"Designation systems for steels Part 2 : Numerical system (en 10027-2:2015)","key":"10.1016\/j.ijhydene.2025.04.534_bib61"},{"year":"1994","series-title":"ASM specialty handbook: stainless steels","key":"10.1016\/j.ijhydene.2025.04.534_bib62"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib66","first-page":"31","article-title":"Emissivity of aluminium and its importance for radiometric measurement","volume":"4","author":"Bartl","year":"2004","journal-title":"Meas Sci Rev"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib65","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/0011-2275(92)90373-I","article-title":"Design characteristics and performance of a liquid hydrogen tank system for motor cars","volume":"32","author":"R\u00fcdiger","year":"1992","journal-title":"Cryogenics (Guildf)"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib67","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.psep.2021.04.026","article-title":"Three dimensional CFD simulation of LPG tanks exposed to partially engulfing pool fires","volume":"150","author":"Scarponi","year":"2021","journal-title":"Process Saf Environ Prot"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib68","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.psep.2020.07.047","article-title":"An overview of test standards and regulations relevant to the fire testing of pressure vessels","volume":"145","author":"Bradley","year":"2021","journal-title":"Process Saf Environ Prot"},{"year":"1999","series-title":"Engineering structures in connection with roads - inspection and test (DIN 1076:1999-11)","key":"10.1016\/j.ijhydene.2025.04.534_bib69"},{"year":"1999","series-title":"Fire resistance tests\u2014Part 2: alternative and additional procedures","key":"10.1016\/j.ijhydene.2025.04.534_bib70"},{"year":"2015","series-title":"Zus\u00e4tzliche Technische Vertragsbedingungen und Richtlinien f\u00fcr Ingenieurbauten (ZTV-ING) Teil 5 \u201cTunnelbau\u201d und Teil 3 \u201cMassivbau\u201d","key":"10.1016\/j.ijhydene.2025.04.534_bib71"},{"year":"1999","series-title":"Fire resistance tests (ISO Standard N. 834)","key":"10.1016\/j.ijhydene.2025.04.534_bib72"},{"year":"2016","series-title":"Heat load resistance of cryogenic storage tanks\u2013Results of LNG Safety Program","author":"Kamperveen","key":"10.1016\/j.ijhydene.2025.04.534_bib73"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib74","first-page":"207","article-title":"UN regulation No. 110 Rev.6","year":"2022","journal-title":"Off J Eur Union"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib75","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1007\/s00231-011-0928-z","article-title":"Experimental study on the storage performance of high-vacuum-multilayer- insulation tank after sudden, catastrophic loss of insulating vacuum","volume":"48","author":"Xie","year":"2012","journal-title":"Heat Mass Transf Und Stoffuebertragung"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib76","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.cryogenics.2010.06.020","article-title":"Study on the heat transfer of high-vacuum-multilayer-insulation tank after sudden, catastrophic loss of insulating vacuum","volume":"50","author":"Xie","year":"2010","journal-title":"Cryogenics (Guildf)"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib77","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.cryogenics.2016.10.006","article-title":"Optimization of variable density multilayer insulation for cryogenic application and experimental validation","volume":"80","author":"Wang","year":"2016","journal-title":"Cryogenics (Guildf)"},{"key":"10.1016\/j.ijhydene.2025.04.534_bib78","doi-asserted-by":"crossref","first-page":"8000","DOI":"10.1016\/j.ijhydene.2021.12.103","article-title":"Thermal analysis of coupled vapor-cooling-shield insulation for liquid hydrogen-oxygen pair storage","volume":"47","author":"Jiang","year":"2022","journal-title":"Int J Hydrogen Energy"}],"container-title":["International Journal of Hydrogen Energy"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360319925022487?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0360319925022487?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,5,11]],"date-time":"2025-05-11T03:06:51Z","timestamp":1746932811000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0360319925022487"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":77,"alternative-id":["S0360319925022487"],"URL":"https:\/\/doi.org\/10.1016\/j.ijhydene.2025.04.534","relation":{},"ISSN":["0360-3199"],"issn-type":[{"type":"print","value":"0360-3199"}],"subject":[],"published":{"date-parts":[[2025,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative performance assessment of multilayer insulation (MLI) systems for liquid hydrogen vessels in fire scenarios","name":"articletitle","label":"Article Title"},{"value":"International Journal of Hydrogen Energy","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.ijhydene.2025.04.534","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Ltd on behalf of Hydrogen Energy Publications LLC.","name":"copyright","label":"Copyright"}]}}</enrichment>
    <enrichment key="local_crossrefDocumentType">journal-article</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="date_peer_review">02.06.2025</enrichment>
    <licence>Creative Commons - CC BY - Namensnennung 4.0 International</licence>
    <author>Davide Camplese</author>
    <author>Giordano Emrys Scarponi</author>
    <author>Robert Eberwein</author>
    <author>Aliasghar Hajhariri</author>
    <author>Frank Otremba</author>
    <author>Valerio Cozzani</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Cryogenic storage tank</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <collection role="ddc" number="604">Spezielle Themen</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei für die Öffentlichkeit verfügbar ("Open Access")</collection>
    <collection role="unnumberedseries" number="">Wissenschaftliche Artikel der BAM</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
    <thesisPublisher>Bundesanstalt für Materialforschung und -prüfung (BAM)</thesisPublisher>
    <file>https://opus4.kobv.de/opus4-bam/files/63084/Camplese_2025_performance_assessment_MLI_in_fire.pdf</file>
  </doc>
  <doc>
    <id>63740</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>205</pageFirst>
    <pageLast>210</pageLast>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>conferenceobject</type>
    <publisherName/>
    <publisherPlace>Prag</publisherPlace>
    <creatingCorporation>International Institute of Refrigeration (IIR)</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Repeatable testing of a cryogenic storage tank with variable insulation material in fire like conditions</title>
    <abstract language="eng">For decarbonizing the energy industry and transport, cryogenic energy carriers have great potential. The storage takes place in tanks with thermal super-insulations, which are in application for decades, but there is only limited knowledge about its behaviour in a fire scenario. This represents a major incident that may generate extraordinary loads on the tank and its insulation system, and that eventually lead to a sudden tank failure. This paper presents a test rig called the Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC), which can be used to test typical thermal superinsulation’s under cryogenic and fire-like conditions in parallel. The test method makes it possible to measure the heat flow through the thermal superinsulation over time and to investigate the degradation behaviour of the insulation within a test. In the paper results from the first tests are presented.</abstract>
    <parentTitle language="eng">Proceedings 18th Cryogenics</parentTitle>
    <identifier type="doi">10.18462/iir.cryo.2025.0007</identifier>
    <enrichment key="eventName">18th Cryogenics 2025, IIR Conference</enrichment>
    <enrichment key="eventPlace">Prague, Czech Republic</enrichment>
    <enrichment key="eventStart">07.04.2025</enrichment>
    <enrichment key="eventEnd">11.04.2025</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Robert Eberwein</author>
    <author>Aliasghar Hajhariri</author>
    <author>Frank Otremba</author>
    <author>Davide Camplese</author>
    <author>Giordano E. Scarponi</author>
    <author>Valerio Cozzani</author>
    <author>Holger Seidlitz</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Safety</value>
    </subject>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Graue Literatur</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
  </doc>
  <doc>
    <id>62979</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Repeatable Testing of a Cryogenic Storage Tank with Variable Insulation Material in Fire Like Conditions</title>
    <abstract language="eng">For decarbonizing the energy industry and transport, cryogenic energy carriers have great potential. The storage takes place in tanks with thermal super-insulations, which are in application for decades, but there is only limited knowledge about its behaviour in a fire scenario. This represents a major incident that may generate extraordinary loads on the tank and its insulation system, and that eventually lead to a sudden tank failure. This paper presents a test rig called the Cryogenic High Temperature Thermal Vacuum Chamber (CHTTVC), which can be used to test typical thermal superinsulation’s under cryogenic and fire-like conditions in parallel. The test method makes it possible to measure the heat flow through the thermal superinsulation over time and to investigate the degradation behaviour of the insulation within a test. In the paper results from the first tests are presented.</abstract>
    <enrichment key="eventName">18th Cryogenics 2025, IIR Conference</enrichment>
    <enrichment key="eventPlace">Prague, Czech Republic</enrichment>
    <enrichment key="eventStart">07.04.2025</enrichment>
    <enrichment key="eventEnd">11.04.2025</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Robert Eberwein</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
  </doc>
  <doc>
    <id>63628</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst/>
    <pageLast/>
    <pageNumber/>
    <edition/>
    <issue/>
    <volume/>
    <type>lecture</type>
    <publisherName/>
    <publisherPlace/>
    <creatingCorporation/>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">New concepts in liquid hydrogen storage</title>
    <abstract language="eng">On the way to the energy transition, cryogenic fluids such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) are very important. They enable the large-scale economic transport and storage of energy as well as they represent alternative fuels for energy-intensive mobile applications such as aircrafts, ships and HGVs. For the last one, the number of vehicles and fuel stations has increased rapidly in the last 10 years all over Europe. Does this also entail new risks, for instance from a BLEVE in case of fires? To answer this question, BAM has conducted several research projects over the last decades and intensified the research recently with several experimental, numerical, and empirical outcomes on how a tank with insulation behaves in a fire. The presentation shows an overview of this research. The findings are relevant for global standardization procedures and to improve the overall safety in chemistry and technics.</abstract>
    <enrichment key="eventName">Hydrogen Refueling Station Opening</enrichment>
    <enrichment key="eventPlace">Baruth/Mark, Germany</enrichment>
    <enrichment key="eventStart">03.07.2025</enrichment>
    <enrichment key="eventEnd">03.07.2025</enrichment>
    <enrichment key="InvitedTalks">0</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Robert Eberwein</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Insulation</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Safety</value>
    </subject>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="literaturgattung" number="">Präsentation</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
  </doc>
  <doc>
    <id>63738</id>
    <completedYear/>
    <publishedYear>2025</publishedYear>
    <thesisYearAccepted/>
    <language>eng</language>
    <pageFirst>181</pageFirst>
    <pageLast>186</pageLast>
    <pageNumber/>
    <edition/>
    <issue>116</issue>
    <volume/>
    <type>article</type>
    <publisherName>AIDIC</publisherName>
    <publisherPlace/>
    <creatingCorporation>AIDIC</creatingCorporation>
    <contributingCorporation/>
    <belongsToBibliography>0</belongsToBibliography>
    <completedDate>--</completedDate>
    <publishedDate>--</publishedDate>
    <thesisDateAccepted>--</thesisDateAccepted>
    <title language="eng">Investigation of Realistic Fire Scenarios Involving Cryogenic Storage Tanks</title>
    <abstract language="eng">The number of vehicles using or transporting cryogenic fuels such as Liquefied Hydrogen (LH2) or Liquefied Natural Gas (LNG) increases fast in the land transportation sector. Does this also entail new risks for instance from a BLEVE? A key to answer this question is to research representative fires by its characterization and its effect on the insulation. At BAM’s technical test side in Germany, a test series was started to answer this question among others. This paper presents results on a pool fire under a colorimeter, that simulates a tank. The investigation points out, that the full fire characterization approach allows to represent the fire. The findings are relevant for the investigation of a representative design fire that is applicable for the approval and improvement of tanks as well as to research accident scenarios and their consequences.</abstract>
    <parentTitle language="eng">Chemical Engineering Transactions</parentTitle>
    <identifier type="issn">2283-9216</identifier>
    <identifier type="doi">10.3303/CET25116031</identifier>
    <enrichment key="eventName">Loss Prevention 2025</enrichment>
    <enrichment key="eventPlace">Bologna, Italien</enrichment>
    <enrichment key="eventStart">09.06.2025</enrichment>
    <enrichment key="eventEnd">11.06.2025</enrichment>
    <enrichment key="opus.source">publish</enrichment>
    <enrichment key="opus.doi.autoCreate">false</enrichment>
    <enrichment key="opus.urn.autoCreate">true</enrichment>
    <author>Robert Eberwein</author>
    <author>Jennifer Heßmann</author>
    <author>Jan Werner</author>
    <author>Giordano Emrys Scarponi</author>
    <author>Valerio Cozzani</author>
    <author>Frank Otremba</author>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LH2</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>LNG</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Fire</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Tank</value>
    </subject>
    <subject>
      <language>eng</language>
      <type>uncontrolled</type>
      <value>Safety</value>
    </subject>
    <collection role="ddc" number="604">Spezielle Themen</collection>
    <collection role="ddc" number="621">Angewandte Physik</collection>
    <collection role="ddc" number="624">Ingenieurbau</collection>
    <collection role="institutes" number="">3 Gefahrgutumschließungen; Energiespeicher</collection>
    <collection role="themenfelder" number="">Energie</collection>
    <collection role="themenfelder" number="">Elektrische Energiespeicher und -umwandlung</collection>
    <collection role="themenfelder" number="">Infrastruktur</collection>
    <collection role="themenfelder" number="">Fire Science</collection>
    <collection role="themenfelder" number="">Security</collection>
    <collection role="themenfelder" number="">Chemie und Prozesstechnik</collection>
    <collection role="literaturgattung" number="">Verlagsliteratur</collection>
    <collection role="fulltextaccess" number="">Datei im Netzwerk der BAM verfügbar ("Closed Access")</collection>
    <collection role="institutes" number="">3.5 Sicherheit von Gasspeichern und Gefahrguttanks</collection>
    <collection role="themenfelder" number="">Wasserstoff</collection>
    <collection role="themenfelder" number="">Gefährliche Stoffe</collection>
  </doc>
</export-example>